• Title/Summary/Keyword: 지진력 스펙트럼

Search Result 43, Processing Time 0.028 seconds

Maximum Control Force for Sliding Mode Controller with Saturation Problem (포화현상을 고려한 슬라이딩 모드제어기의 최대제어력 산정)

  • 이상현;민경원;김홍진;이영철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • Sliding mode control (SMC), which is one of active control algorithms showing remarkable control performance, requires the excessive control force for control of seismically excited civil structures. Therefore, controller saturation should be considered in design of SMC. In this study, a method for determining the maximum control force is developed in terms of the fraction of the lateral restoring force using a design response spectrum. Numerical analyses of MDOF structures with one or multiple control devices verify the effectiveness of the proposed method for the control of seismically excited civil structures with saturation problem.

Proposal and Evaluation of Ground Response Spectrum Estimation Algorithm based on Seismic Observation Data (지진 관측데이터 기반 지반응답스펙트럼 추정 알고리즘 제안 및 평가)

  • Ahn, Jin-Hee;Jeong, Jin-Woo;Hong, Yu-Chan;Park, Jae-Bong;Choi, Hyoung-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.13-22
    • /
    • 2019
  • In order to evaluate the earthquake damage level of small and medium - sized bridges without earthquake monitoring system, we proposed an algorithm for estimating the seismic force at the target bridge location using the ground acceleration data from the earthquake observatories near the structure. In general, response spectrum analysis, which is the most widely used dynamic analysis method to design and evaluate the structural system numerically is required a response spectrum to determine the dynamic loading. In this study, selection methods of the three closest observatories from the target structure and estimation method of ground response spectrum at arbitrary locations are developed. The proposed method can consider the distance and phase between the target bridge and the seismic station and from the relationship between the acceleration amplitudes and the location of the selected seismic station, the earthquake loading of the target bridge can be determined. The proposed algorithm is estimated to be more conservative than the response spectrum evaluated by actual earthquake data.

Scale-Up Factor for Seismic Analysis of Building Structure for Various Coordinate Systems (건축구조물의 지진해석에서 좌표축의 설정에 따른 보정계수 산정법)

  • Yu, Il-Hyang;Lee, Dong-Guen;Ko, Hyun;Kim, Tae-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.33-47
    • /
    • 2007
  • In a practical engineering, the equivalent static analysis (E.S.A) and the response spectrum analysis (R.S.A) are generally used for the seismic analysis. The base shears obtained from the E.S.A are invariable no matter how the principal axes of building structures are specified on an analysis program while those from the R.S.A are variable. Accordingly, the designed member size may be changed by how an engineer specify the principal axes of a structure when the R.S.A is used. Moreover, the base shears in the normal direction to the excitation axis are sometimes produced even when an engineer performs a response spectrum analysis in only one direction. This tendency makes the base shear, which is used to calculate the scale-up factor, relatively small. Therefore the scale-up factor becomes larger and it results in uneconomical member sizes. To overcome these disadvantages of the R.S.A, an alternative has been proposed in this study. Three types of example structures were adapted in this study, i.e. bi-direction symmetric structure, one-direction antisymmetric structure and bi-direction antisymmetric structure. The seismic analyses were performed by rotating the principal axes of the example structures with respect to the global coordinate system. The design member forces calculated with the scale-up factor used in the practice were compared with those obtained by using the scale-up factor proposed in this study. It can be seen from this study that the proposed method for the scale-up factor can provide reliable and economical results regardless of the orientation of the principal axes of the structures.

Equivalent Linear System Considering Earthquake Characteristics of MR damper installed in a SDOF (지진하중 특성을 고려한 단자유도 구조물에 설치된 MR감쇠장치의 등가선형시스템)

  • Moon, Byoung-Wooke-Ri;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.774-777
    • /
    • 2010
  • 본 논문에서는 MR 감쇠기의 비선형 특성을 등가의 선형감쇠로 치환하기 위한 방법으로 Newmark와 Hall이 제안한 감쇠계수를 이용하였다. 응답스펙트럼의 감쇠율을 나타내는 감쇠기계수는 구조물의 최대변위를 이용하여 등가감쇠비를 추출할 수 있다는 장점을 가지고 있다. 하지만 이러한 응답스펙트럼은 구조물에 작용하는 지진하중의 특성에 따라 경향이 달라진다. 본 논문에서는 기존의 등가감쇠비 산정식을 수정하여 제안하고, 지진하중 특성에 따른 등가감쇠비의 변화를 살펴보았다. MR 감쇠기의 등가감쇠비는 가진하중과 최대마찰력의 비율에 따라 결정되며, 장주기 구조물의 경우 등가감쇠비가 감소한다. MR 감쇠기의 점성은 마찰감쇠와의 상호작용에 의해 단순한 산술합 이상의 감쇠비 증가 효과를 가진다.

  • PDF

A Study on the Dynamic Lateral Displacements of Caisson Quay Walls in Moderate Earthquake Regions (중진지역에서 케이슨 안벽의 동적수평변위 특성에 관한 연구)

  • Park, Keun-Bo;Sim, Jae-Uk;Cha, Seung-Hun;Kim, Soo-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.8
    • /
    • pp.137-148
    • /
    • 2008
  • In this study, 28 earthquake records with magnitudes from 5.3 to 7.9 are selected for dynamic analysis in order to assess applicability of the earthquakes for domestic seismic design. The assessment is performed using the seismic spectrum analysis of energy and acceleration. Based on results of the analysis, four acceleration time histories, which satisfy the Korean design standard response spectrum, are proposed. From the dynamic analysis using earthquake magnitudes from 6.4 to 7.9, it is found that horizontal displacements corresponding to earthquake magnitudes greater than 7 are two times larger than those with magnitude 6.5. Therefore, it can be stated that use of strong earthquakes, such as Miyagiken-ken-oki earthquake (Ofunato, $M_{JMA}=7.4$) and Tokachi-oki earthquake (Hachinohe, $M_{JMA}=7.9$), for the seismic design in Korea is not applicable, and may prove to be excessively conservative due to overestimated seismic force. From the dynamic analyses using the proposed acceleration time histories, effects of caisson quay wall dimension and the subsoil condition are investigated as well. The simplified design charts to evaluate horizontal displacements of caisson quay wall are also proposed based on earthquake magnitude 6.5 that is appropriate in Korea.

지진의 성질과 내진설계

  • 홍갑표
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.6-10
    • /
    • 1995
  • 본 글에서는 지진의 기본적인 성질, 지진파의 특성, 스펙트럼 및 내진설게시 고려되어아 할 사향에 대하여 알아보았다. 점점 고층화되어가는 건축구조물에 대한 내진설계의 필요성이 더욱 커지고 있는 때에, 발생한 일본 고베 지진의 피해는 국내 의 건축구조 학자와 저눈가에 큰 영향을 주었을 것으로 생각된다. 예를 들어, 콘크 리트 건물의 설계시 기둥의 대근(hoop)의 중요성이 드러났으며, 질량이 무거운 건물 이 관성력을 더 많이 받게 되어 큰 피해가 발생한 것을 알 수 있었다. 구조물의 재료 적인 성질의 변화와 구조시스템의 변화를 이용한 내진설계에 대한 연구가 더욱 활발 히 진행될 것으로 생각되며, 또한 지진에 따른 건물의 진동을 조절하기 위한 진동 제어분야도 더 많은 연구가 필요하다고 생각된다.

  • PDF

노스리지 지진하의 강 뼈대 구조물에 대한 사례 연구

  • 김기동
    • Computational Structural Engineering
    • /
    • v.11 no.1
    • /
    • pp.46-57
    • /
    • 1998
  • 노스리지 지진하의 모멘트 저항 강 뼈대 구조물에 대한 사례연구결과를 요약하면 다음과 같다. 1) 탄성과 비탄성 동적해석 방법의 신뢰도가 구조물의 동적거동의 모형화에 크게 영향을 받는다는 것을 알 수 있었고 구조물의 동적거동의 모형화를 위한 보다 개선된 지침과 기준의 필요성이 부각되었다. 2) 비탄성 횡방향 정적해석은 6층높이의 건물까지는 비탄성동적해석과 유사한 결과를 보였으나 10층 이상의 건물에서는 고차 모드 효과를 고려하지 못하여 상당히 상이한 결과를 나타냈다. 3) 응답스펙트럼 해석은 노스리지 지진하에서 탄성 시간이력 해석에 비하여 100%까지 상이한 결과를 보였다. 특정지진에 대한 구조물거동의 상세조사시 응답 스펙트럼 해석 대신 시간이력해석을 수행하는 것이 바람직하다. 4) 탄성 부재력의 저항능력 비와 소성 회전각 등의 거동지수 등은 현존하는 건물의 연결부 손상을 검사하기 위한 지침을 마련하는데 도움을 줄 수 있지만 특정 연결부를 검사에서 배제시키는 유일한 근거로 사용되어서는 안될 것으로 판단된다.

  • PDF

Scaling Method of Earthquake Records for the Seismic Analysis of Tall Buildings (초고층 구조물의 지진해석을 위한 지진기록의 조정방법)

  • Kim, Tae-Ho;Park, Ji-Hyeong;Kim, Ook-Jong;Lee, Do-Bum;Ko, Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.5
    • /
    • pp.11-21
    • /
    • 2008
  • In recent years, time history analysis has been the method generally used for the seismic analysis of tall buildings with damping devices. When T is the natural period of the first vibration mode of the structure, the sum of the spectral acceleration of the earthquake ground motion is usually adjusted to that of the design response spectrum in the period ranging from 0.2T to 1.5T to meet the requirements of design code. However, when the ground motion is scaled according to the design code, the differences in the responses obtained by response spectrum analysis (RSA) and time history analysis (THA) of the structures increase as the natural period of the structure becomes longer. When time history analysis is performed by using ground accelerations that are scaled according to the design code, base shear is similar to that obtained from RSA, but other responses, such as displacements, drifts and member forces, are underestimated compared to RSA. If these results are adjusted by multiplying with the scale-up factor, the scaled responses become much smaller. Therefore, a scaling method of ground motions corresponding with the design code is proposed in this study, as a way of assisting structural engineers in generating artificial ground motions.

Generation of Artificial Time History Covering Design Response Spectrum by Two Modification Functions (이중 수정함수 적용을 통한 설계응답스펙트럼 포괄 인공지진파의 생성)

  • Park, Gun;Hong, Ki Nam;Han, Sang Hoon;Kim, Jae Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The domestic and foreign seismic design codes have specified that time history covers design response spectrum when the response spectrum, which calculated from the time history, is smaller than the design response spectrum at five points or less. In order to verify the design codes, time history analysis for a pier was performed by using five artificial time histories conforming design code with various characteristics and its member forces were evaluated according to them. It was confirmed from analysis results that, regardless of the conformity to design code requirement, seismic design using the artificial time histories could not guarantee earthquake resistant design if the response spectrum from them is lower than design response spectrum at the similar period to the natural frequency of structure. Thus, the time history generating method to make its acceleration response spectrum to be greater than design response spectrum at all period was proposed by two modification function in this study. It was also verified whether time histories from the proposed method satisfy the seismic design codes or not.

High Frequency Approximation for Earthquake-Induced Hydrodynamic Loads in Rigid Stroage Tank (고주파수 근사해를 적용한 유체저장탱크에 작용하는 지진하중 산정)

  • 류정선;양우식
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • The present paper describes an approximation for estimation of earthquake-induced hydrodynamic loads in rigid storage tank which accelerated in horizontal direction. The storage tank is vertically cylindrical, and the sectional shape may be circular, rectangular or irregular. The solution for harmonic excitation is studied based on velocity potential theory, and then the time domain solution for earthquake is obtained by using design response spectrum. As a result, earthquake load is influenced primarily by the inertia force of high frequency effective mass of the storage tank, responding to the characteristics of design response spectrum, tank sectional shape, and the ratio of tank base length to depth. Earthquake-induced hydrodynamic loads in rigid storage tank can be effectively obtained by using the high frequency approximation method in case of quite large, or small ratio of the tank base length to water depth.

  • PDF