• Title/Summary/Keyword: 지중환경

Search Result 450, Processing Time 0.028 seconds

A Development of Automation System and a Way to use Solar Energy System Efficiently in Greenhouse(1) - Study on temperature variation of soil heating in greenhouse - (시설원예용 태양열 시스템의 효율적 이용과 자동화 장치개발(1) - 시설재배시 지중가온의 온도변화 연구 -)

  • 김진현;김철수;명병수;최중섭;구건효;김태욱
    • Journal of Bio-Environment Control
    • /
    • v.7 no.1
    • /
    • pp.15-24
    • /
    • 1998
  • The greenhouse temperature controls in general have been managed by the above-ground part environment, But the temperature of root zone was known very important factor for the 9rofth and the yield of vegetables in greenhouse. The purpose of this study is to develop a good method for cultivation using solar energy which can apply warming soil and to develop the greenhouse soil temperature automatic control system. Followings are summary of this study:1 When the greenhouse inner temperature changes were about 24$^{\circ}C$ during a day in October, the temperature of non-warmed soil was differenced 6$^{\circ}C$ in the depth 10cm and 3$^{\circ}C$ in the depth 20cm. 2. When water supply temperature was kept at 40, 50 and 6$0^{\circ}C$, the lowest soil temperature in the depth of 10cm is 2$0^{\circ}C$ and that of 20cm was 23$^{\circ}C$. and when the water supply temperature was over 4$0^{\circ}C$, the space heating temperature did not affect the temperature variation of soil. 3. In comparison with conditions of the warmed and non-warmed soil, when the water supply temperature is 28$^{\circ}C$, soil temperatures had the high temperature of 4$0^{\circ}C$~7$^{\circ}C$ in the depth of 10cm to 20 cm. 4. The line of boundary area was appeared in the depth of 15~20cm, 13~19cm and 12~17cm. when the water supply temperature was 4$0^{\circ}C$, 5$0^{\circ}C$ and 6$0^{\circ}C$. 5. When th inner greenhouse air temperature is maintained over 11$^{\circ}C$ and the water supply temperature is supported 28$^{\circ}C$, the lowest temperature is kept up over 2$0^{\circ}C$.

  • PDF

Pulling Force and Manure Spreading Characteristic of Tractor-drawn Animal Slurry Manure Sub-soil Injector (가축분뇨액비 지중살포기의 견인력 및 살포 특성)

  • Choe K. J;Lee S. H.;Ryu B. K.;Oh K. Y.;Park H. J.;Lee S. T.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.1
    • /
    • pp.25-34
    • /
    • 2005
  • The study aimed to develop a tractor drawn animal slurry manure sub-soil injector for arable land and thus, can reduce the waste management cost through effective treatment and utilization of animal slurry manure. The application of animal slurry manure to agricultural land will probably be one of the most effective ways to enrich the soil with vital nutrients. However, some existing slurry manure spenders are not suitable in the field because of their adverse effects to the environment. Based on this premise, a prototype was designed and assembled using 5 sub-soiling standards attached to the sin injector device. The traction force of the Prototype measured in the depth of 10 cm and 15 cm from the ground surface of a paddy field was 1,062 kgf and 1,214 kgf, respectively. A unique feature of the machine was that there was an equal volume of slurry manure flowing from each delivery pipe and regulated by a pressurized container that was likewise synchronized with the speed of the tractor The sub-soiling manure injection system can mitigate or reduce the harmful emission of obnoxious gases and malodor during the injection operation.

  • PDF

Application of HWAW Method to Detect Underground Anomaly in Shallow Depth (지표 근처 지중 이상체 파악을 위한 HWAW 기법의 적용)

  • Bang, Eun-Seok;Kim, Gyeong-Seob;Son, Jeong-Sul;Kim, Dong-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1C
    • /
    • pp.11-20
    • /
    • 2009
  • A new alternative method based on HWAW method to detect underground anomaly was introduced. The location of underground anomaly can be estimated by using 2-dimensional image of phase velocity image with position and wavelength based on distortion phenomena of surface wave due to underground anomaly. Overall procedure of proposed method such as field testing, signal processing and interpretation of the result was introduced. Numerical verification study was performed by using various ground models containing underground anomaly. According to the condition of anomaly, the propagation and reflection characteristics of surface wave were different and this could be more easily shown in the image of phase velocity. Some rules of distortion phenomena were found and these become clues for estimating underground anomaly in interpreting real field data. Field verification tests were performed with conventional geophysical methods such as DC resistivity method and GPR. Though field condition is not homogeneous like numerical models, similar distortion phenomena were found in the testing results and estimated location of underground anomaly was agreed well with the results of another geophysical methods.

Control of Root-Knot Nematode(Meloidogyne incognita Chitwood) by Root Zone Warming System (지중가온시설을 이용한 고구마뿌리흑선충 방제)

  • 신용습;연일권;최성국;최부술;이우승
    • Journal of Bio-Environment Control
    • /
    • v.7 no.2
    • /
    • pp.139-143
    • /
    • 1998
  • This experiment was conducted to investigate the effect of soil heating on control of root-knot nematode(Meloidogyne incognita Chitwood) by root zone warming system. Root zone was warmed by hot water flowing through pipe set at 35cm depth from the ridge The lowest soil temperatures at 20cm depth were set at 3$0^{\circ}C$, 4$0^{\circ}C$, $50^{\circ}C$ and non-warming. under soil submerging condition and non-submerging condition. Soil heating was done for 5 days(120 hours) from Aug. 1 to Aug. 5. The root-knot nematode juvenile densities of 4$0^{\circ}C$ under submerging condition. and $50^{\circ}C$ under non-submerging condition were 0 which was expected lower than the economic injury level. The contents of OM P$_2$ $O_{5}$, Ca Mg and EC in soil were decreased by root zone warming The EC was considerably lowered under submerging condition.

  • PDF

The Method of Certificating Waterproof Effect for Consecutive Column-Wall Mass in Underground (주열식 지중연속벽체의 차수효과 확인 방안)

  • Koh, Yong-IL
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.9
    • /
    • pp.5-9
    • /
    • 2017
  • On the flow of groundwater, the effect of consecutive column-wall in underground as a hydraulic barrier could be identified by conventional geotechnical methods ((1)visualiy identification of wall mass after underground excavating, (2)uniaxial compressive strength test for core of wall mass in underground, (3)in-situ permeability test in the hole after coring wall mass). However, for the cut off the leakage or infiltration of very high concentrated leachate from the waste landfill or the contaminated groundwater, the waterproof effect of consecutive column-wall in underground should be verified more objectively, by in-situ measuring of pH, temperature and salinity. and by evaluating of their consistency and similarity throughout analyzing the characteristics of basic components and their profiles through the series of chemical experiments. Furthermore, its waterproof effect could be verified additionally throughout deciding the similarity more simply by comparing the general distribution patterns including the difference of high and low peaks from the chromatograms using GC-MS for surrounding groundwater.

Study on the discharge of soil particles and ground collapse through cracks in underground structures (지중구조물 균열을 통한 토립자 유출 및 지반함몰 특성 연구)

  • Kim, Ho-Jong;Kim, Kang-Hyun;Shin, Jong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.699-715
    • /
    • 2019
  • Recently, in urban areas, cavities and ground collapse adjacent to underground structures are frequently reported. Several studies on the cavity generation by structure cracks have been made, however they are focused on the cause of cracks and settlement of the ground. In this paper, soil particle and groundwater discharge through pipe cracks and cavity generation mechanism are investigated. The theoretical analysis of the groundwater, which is the main factor of the drainage of the soil particles, and the particle transport mechanism and flow characteristics were investigated. An experimental model test was carried out to identify the mechanism of cavity generation by underground buried pipe cracks. The soil particle weight of discharge through the cracks, and the movement characteristics of the particles were analyzed using PIV. In this study, it is clearly identified that soil particle movements, cavity generation and ground collapse that occur in the ground are basically caused by the movement of groundwater.

Numerical Stability Evaluation of Underground Semi-Spherical Cavity (반구형 지중공동의 수치해석적 안정성 평가)

  • Lee, Taegeon;Ryu, Dong-Woo;Youn, Heejung
    • Tunnel and Underground Space
    • /
    • v.32 no.1
    • /
    • pp.20-29
    • /
    • 2022
  • The existence of underground cavity should be considered in the assessment of georisk such as ground subsidence. Even if the shear strength of the ground around the cavity is known, it is difficult to accurately analyze the safety around the cavity due to the uncertainties related to geometric conditions such as the cavity size. In this paper, stability chart representing dimensionless stability constants was proposed based on the ground strength and geometric conditions. Numerical analysis had been carried out accounting for the stability constants such as the ground strength, the adhesion and friction angles, and the size and depth of the underground cavity. The proposed charts can help estimating the stability of ground with underground circular cavity.

Increase of CO2 Injection Ratio Using Surfactants Based on the Micromodel Experiment (마이크로모델 실험 기반 계면활성제를 활용한 이산화탄소 주입효율 향상)

  • Seokgu, Gang;Jongwon, Jung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.12
    • /
    • pp.55-61
    • /
    • 2022
  • Carbon dioxide is one of the greenhouse gases in the atmosphere and much research is underperforming in reducing carbon dioxide. Geological carbon dioxide storage is considered the primary technique for global warming prevention. So, technic development for storing carbon dioxide is required. Using surfactant is considered an effective material for geological carbon dioxide storage. However, research on using surfactants for carbon dioxide sequestration is not enough. In this study, a 2D micromodel experiment depends on the surfactant type (sodium dodecyl sulfate and sodium dodecylbenzene sulfonate), concentration and carbon dioxide injection rate. As result, geological carbon dioxide sequestration efficiency is increased according to surfactant concentration and carbon dioxide injection rate increase. However, efficiency no more increases after critical concentration and rate.

Characteristic of Injection According to CO2 Phases Using Surfactants (계면활성제를 활용한 이산화탄소 상태에 따른 주입특성 평가)

  • Seokgu Gang;Jongwon Jung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.6
    • /
    • pp.5-11
    • /
    • 2023
  • The engineering industry heavily relies on fossil fuels such as coal and petroleum to generate energy through combustion. However, this process emits carbon dioxide into the atmosphere, leading to global warming. To mitigate this issue, researchers have explored various methods to reduce carbon dioxide emissions, one of which is carbon dioxide underground storage technology. This innovative technology involves capturing carbon dioxide from industrial plants and injecting it into the saturated ground layer beneath the earth's surface, storing it securely underground. Despite its potential benefits, carbon dioxide underground storage efficiency needs improvement to optimize storage in a limited space. To address this challenge, our research team has focused on improving storage efficiency by utilizing surfactants. Furthermore, we evaluated how different carbon dioxide states, including gaseous, liquid, and supercritical, impact storage efficiency based on their respective pressures and temperatures within the underground reservoir. Our findings indicate that using surfactants and optimizing the injection rate can effectively enhance storage efficiency across all carbon dioxide states. This research will pave the way for more efficient carbon dioxide underground storage, contributing to mitigating the environmental impact of fossil fuels on the planet.