• Title/Summary/Keyword: 증기 주입량

Search Result 24, Processing Time 0.026 seconds

Effect of the Steam Flow Rate on Syngas Productivity in IGCC Gasifier for a Power Generation (IGCC 발전용 가스화기에서 증기 주입량이 합성가스 생산량에 미치는 영향)

  • Keum, Kyung-Nam;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.15 no.3
    • /
    • pp.29-34
    • /
    • 2019
  • In the study, the effect of steam injection on syngas productivity was investigated under the constant operating conditions of gasifier oxygen load while the coal feed was fixed and the steam injection flow rate is changed in Taean IGCC plant. The maximum syngas average productivity was found to be at 80 % and 90 % of gasifier oxygen loads with the steam injection flow rate of 0.14 kg/s and 0.15 kg/s per coal burner. Through this study, the syngas productivity was changed by adjusting the steam injection amount and as the steam injection flow rate increased, the syngas productivity increased and then decreased again. The syngas productivity can be increased only by steam injection without supplying additional coal and it is considered that the syngas productivity has different characteristics depending on coal type. Thus it is recommended to operate the gasifier using Carbo-One coal with the steam injection flow rate of about 0.14 kg/s per coal burner when the gasifier oxygen load is 80 % ~ 90 %.

토양의 특성에 따른 토양증기추출법 (Soil Vapor Extraction)의 Trichloroethylene (TCE)과 Toluene 정화 효율 실험

  • 강현민;이민희;정상용
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.191-194
    • /
    • 2002
  • 토양증기추출(Soil Vapor Extraction)법을 이용하여 대표적 휘발성 NAPL (Non-aqueous phase liquid)인 TCE (trichloroethylene)와 toluene을 토양으로부터 제거하는 칼럼 실험을 실시하였다. 토양특성 및 증기추출 조건들이 정화효율에 미치는 영향을 규명하는데, 균질한 Ottawa sand와 실제 오염지역의 토양들을 직경 2.5cm, 길이 30cm인 유리 칼럼이 충진시켰으며, 빨갛게 염색된 TCE 또는 toluene 4 g이 주입되었다 공기 유량계를 설치하여 0.03L/min의 일정한 속도로 공기가 주입되도록 하고, 퍼지장치를 설치하여 주입 공기의 습윤도를 99% 이상으로 유지하였다. 가스크로마토그래피로 유출 가스 농도를 분석하였다. Ottawa sand로 충진된 칼럼실험에서는 매질의 입자크기, 함수율, 토양 내 오염물 체류시간 등을 변화시켜 실험을 반복하였다. TCE로 오염된 세립질 Ottawa sand 칼럼실험에서 유출 공기의 최대 농도는 조립질 Ottawa sand 칼럼의 유출 농도보다 약 20% 정도 감소하였고, 오염지역의 실제토양 칼럼실험에서는 최대유출농도가 조립질 Ottawa sand 칼럼의 농도보다 약 50% 감소하였으나, 20 liter공기 주입 후부터는 모두 비슷한 농도감소 현상을 나타내었으며, 초기 주입량의 90 % 이상이 제거되었다. 함수율증가에 따른 유출공기의 농도 감소는 거의 나타나지 않았으며, TCE 주입 후 7일 동안 방치하였다가 SVE를 실시한 칼럼 실험에서도 잔류하는 TCE의 양이 약간 증가하였지만 20 liter 공기 추출 후에는 초기 주입량의 90% 가, 40 liter공기 추출 후에는 98% 이상이 제거되었다. Toluene으로 오염된 칼럼 실험에서도 TCE와 비슷한 제거 경향을 나타냈으며 200 liter 공기 추출 후에는 오염물 초기 주입량의 98% 이상이 제거되었다. 본 실험 결과로부터 증기추출법을 이용한 TCE, toluene 정화 효율성이 규명되었으며, 휘발성 NAPL로 오염된 실제 토양을 복원하기 위한 SVE법의 적용가능성을 확인할 수 있었다.

  • PDF

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

증기주입기 해석을 위한 이상 유동 코드 개발

  • 이승진;이은철;이경진
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.573-578
    • /
    • 1997
  • 기존 냉각수 주입 계통의 안전성 및 신뢰도를 높이려는 노력에서 미국, 일본, 이태리 등 여러 나라에서는 증기 주입기에 대한 분석 기법 개발과 실험을 통한 연구가 활발하게 진행되고 있다. 이들이 이상 유동 현상이 일어나는 혼합 노즐을 해석하기 위해 사용한 방법은 제어체적 분석기법으로, 이 분석 방법에서는 응축 메커니즘을 고려할 수 없다. 본 연구에서는 이러한 사항을 개선하기 위해 혼합 노즐 해석시 one dimensional two fluid model을 적용하여 상간의 운동량 및 에너지 전달을 고려함으로써 비교적 정확하게 해석 모델 및 코드를 개발하였고, 출력 변수인 방출 압력과 방출 온도를 계산하였으며, 개발한 해석 코드를 검증 및 분석을 하기 위해 ANL 실험자료를 근거로 하였다. 개발한 코드에 의해 계산된 방출 압력은 ALN 실험치에 비해 높은 경향을 보여 주었지만 ANL에서 제어 체적 분석 기법을 적용하여 이론식으로 계산한 값보다는 비교적 정확한 경향을 보여 주었다.

  • PDF

유류 오염토양 복원을 위한 물리적 기술의 현장적용에 관한 기초연구

  • 강희만;이주광;이용은;고석오
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.160-163
    • /
    • 2001
  • 유류 오염 토양에 pilot scale 규모의 토앙세척법(soil flushing)과 토양증기추출법(SVE)을 설치하여 운전하였다. 토양세척법의 경우 용매인 알콜류를 주입하고 2일 이후부터 계면활성 재인 Tween 80 용액을 주입 한 후 하부에서 추출된 유출수내의 오염물질의 농도를 측정한 결과 BTEX, Diesel 및 n-Alkane의 농도는 계면활성제 수입 전파 후의 비율이 최대 각각 15배 7.8배 및 47배의 농도 증가를 보였으며 TPH 농도의 증가는 약 10배에 이르는 것으로 조사되었다. 또한 토양증기추출법의 경우 가스 추출로 제거된 가스성분의 누적량을 보면 약 19일의 운전기간동안 BTEX와 TPH 총량 기준으로 약 30 kg 및 708 kg이 제거되었으며 BTEX와 TPH에 대한 최대 제거효율은 각각 4 kg/day 및 90 kg/day 였다.

  • PDF

pH Control of Feed Water for HRSG with Additional Injection of NH3 (암모니아 추가 주입에 의한 배열회수보일러 급수의 수소이온농도 조절)

  • Mok, Yong-kang;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.11 no.2
    • /
    • pp.32-38
    • /
    • 2015
  • This study was conducted on combined cycle power plant consisting of HRSG with integral deaerator type to avoid tube failures of low pressure evaporator tubes. Based on the observation of pH variation at the discharge of boiler feed water pump by continuous pH measurement for a period of time, it was identified that pH of feed water is getting reduced as ammonia is distributed into vapor and liquid depending on the distribution ratio of ammonia in the LP drum after the deaerator. To solve this problem, the counterplan was prepared by reexamination of ammonia injection point and quantity. In conclusion, it was accomplished that 9.2~9.6 is the optimized pH range for boiler feed water by arranging additional piping for ammonia to inject directly to LP drum.

  • PDF

Remediation for Gasoline Contaminated Soils with SVE (soil vapor extraction) Including a Post-treatment System of Extraction Gases (배출가스의 후처리 공정을 포함한 토양증기추출법을 이용한 가솔린 오염 토양 복원)

  • 이민희;강현민;이병헌;빈정인
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.2
    • /
    • pp.28-40
    • /
    • 2004
  • Box experiments were performed to evaluate the removal efficiency of SVE (soil vapor extraction) for gasoline in soil. An activated carbon sorption tower and a biofilter were operated as post-treatment processes to remove VOCs extracted from extraction wells of SVE. An acrylic resin box (65 cm${\times}$20 cm${\times}$30 cm) was used to make artificial soil layers and two injection wells and one extraction well were built for SVE process in the box. Gases from extraction wells flew into the activated carbon sorption tower or the biofilter. Gasoline concentrations of VOCs emitted from the extraction well were compared with those after post treatments. More than 92% of initial gasoline mass in soil were removed by SVE within few days, suggesting that SVE is very available to remove VOCs from contaminated soils. To treat VOCs from extraction wells of SVE, an activated carbon sorption tower and a biofilter were attached to SVE process and their gasoline removal efficiencies were measured. These post treatment systems lowered gasoline concentrations to below 1.0 ppm within few days. Average remediation efficiency was 98% of gasoline for the activated carbon sorption tower and 84.1% for the biofilter. The maximum removal capacity of a biofilter was 10.7 g/L/hr, which was ten times higher than general biofilter removal capacity. Results from the study suggest that the activated carbon sorption tower and the biofilter would be available for the post treatment process to remove VOCs generated from SVE process.

Effect of DVI Nozzle Location on the Thermal Mixing in the RVDC (DVI 노즐 위치가 원자로 하향유로내의 냉각수 열적혼합에 미치는 영향 분석)

  • Kang Hyung Seok;Cho Bong Hyun;Kim Hwan Yeol;Yoon Juhyeon;Bae Yoon Yeong
    • Journal of computational fluids engineering
    • /
    • v.3 no.1
    • /
    • pp.89-99
    • /
    • 1998
  • 한국형 차세대원자로에서는 비상노심 안전주입수가 저온관을 통하지 않고 원자로용기에 직접 주입된다. 원자로용기의 가압열충격과 열수력적 관점에서 최적의 노즐위치를 결정하기 위해서 전산유체역학을 활용하였다. 상용 전산유체코드인 CFX를 이용하여 원자로 하향유로를 모사하는 해석대상 격자를 다중불록으로 형성한 다음 유동장을 비압축성 Navier-Stokes 운동량 방정식, 에너지 방정식과 표준 k-ε 난류모형 등으로 모형화하여 3차원 비정상상태 계산을 수행하였다. CFX에서는 경계 밀착좌표계, 비엇물림격자와 SIMPLE 알고리즘을 사용한다. 본 연구결과 원자로용기의 가압열충격 관점에서 가장 보수적인 사고인 증기관 파단사고시에도 열적혼합이 잘 일어나 가압열충격이 발생할 가능성이 없는 것으로 판단되며 안전주입수 노즐이 저온관 바로 위에 위치할 때 원자로 하향유로 내의 온도 분포가 가장 균일하여 열적 혼합 관점에서는 최적의 위치로 판단된다.

  • PDF

Improvement of Boiler Performance on 550 MW Coal Fired Thermal Power Plant via Baffle Plates (다공판 연소가스 유량제어를 통한 석탄화력발전소 보일러 성능 개선)

  • Kim, Chi Ho;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.17 no.1
    • /
    • pp.38-49
    • /
    • 2021
  • In order to increase power plant efficiency, the steam temperature was increased to 610 ℃ which deteriorates the durability of the boiler tube and as the use of low-calorie coal increases the post combustion and delayed combustion phenomenon, the overheating of the final reheater and the tube rupture are becoming frequent. In order to prevent overheating of the final reheater, desuperheater water injection was increased, leading to a decrease in boiler efficiency. In this study install a baffle plate at the back of some overheated tube groups, thereby reduce the temperature of the tube by reducing the amount of combustion gas, and the reduced combustion gas moves to an adjacent place to increase the temperature of other tubes. As a result of the study, the temperature deviation between tubes decreased 1.5. And the heat-reducing injection amount was reduced to 6,929 kg/h and the maximum tube temperature was reduced to 623.4℃ which is 6.6℃ more below than the control standard of 630℃.

Gasification Performance in the Dry-Feeding Gasifier with Variation of Feed Ingredients and Main Operational Problems (건식 가스화기 시료의 선정인자 및 변화에 따른 가스화 특성과 주요 운전상 문제점)

  • 윤용승;정석우;김원배
    • Journal of Energy Engineering
    • /
    • v.10 no.2
    • /
    • pp.90-104
    • /
    • 2001
  • 일일 최대 석탄처리 용략이 3톤인 건식 석탄가스화기를 사용하여 가스화에 미치는 주요 변수들중 산화제내 산소농도와 증기 주입량을 변경시켜 가스화성능을 조사하였고, IGCC용 대성석탄을 선정하는 입장에서의 주요 인자 및 고온고압 조건에서의 가스화기 운전상 특성과 문제점을 파악하여 운전상 문제에 대한 대책을 제시하였다. 사용한 석탄은 유연탄인 중국 대동탄과 아영청탄인 미국 알라스카의 유시벨리탄에었는데, 두 탄중 모두 건식 가스화기의 운전상에는 문제가 없었다. 가스화를 위한 산소의 농도는 90%까지 그리고 석탄시료 무게 대비 증가량 10∼12%까지는 가스화의 온도 유지와 가스조성 측면에서 무리 없이 적용할 수 있다고 판단되었다. 이들 가스화 시험을 통하여 생성된 슬랙은 가스화기 슬랙탭의 조업 온도와 대상석탄 회재의 용융특성에 따라 침상 또는 알갱이 형태로 배출되었으며, 슬랙으로부터 중금속 성분이 유출되는지를 분석해 본 결과 침출수에 의한 2차 오염은 없는 것으로 확인하였다. IGCC용 석탄을 선정하는 석탄특성에서는 미분탄의 수분함량, 회재함량, 회재용융온도, 발열량 측면에서 검토하였는데, 건식가스화기의 경우 미분탄의 표면수분의 제거가 중요하고 회재의 함량과 회재의 용융온도를 같이 고려하여 적정한 시료 석탄이 선정되어야 한다는 결론을 얻었다. 가스화기 운전측면에서는 여러 기계적인 문제점들이 발견되었는데 시료공급노즐의 막힘문제, 역화문제, 고온가스 누출문제, 추운 겨울 운전시 오링(O-ring)문제 등에 대한 논의와 대책을 제시하였다.

  • PDF