• 제목/요약/키워드: 증기압축 냉동사이클

검색결과 21건 처리시간 0.031초

전동 스크롤압축기의 운전rpm에 따른 냉동사이클의 성능에 대한 실험적 연구 (Experimental Study on the Performance of Refrigeration Cycle for various RPM of Inverter Scroll Compressor)

  • 이규선;이근안;이형욱;이영선;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.42-48
    • /
    • 2014
  • An experimental study was performed estimating COP(Coefficient of Performance) of air-conditioning cycle with inverter scroll compressor. All experiments were done for various compressor speeds from 1000~4000 rpm and used the inverter controller called CANDy to change the compressor rpm. The air-conditioning cycle components in the apparatus were used as same with components of YF hybrid car. To estimate the COP, this study measured the temperature and pressure at inlets and outlets of compressor, condenser, and evaporator. And also measured the compressor input power using Powermeter. Through the experiments, the maximum error to estimate COP was shown about ${\pm}6.09%$ at 3500rpm. This study revealed that the condenser temperature and pressure were increased and the evaporator temperature and pressure were decreased with the increased compressor speed. And also, the COP was decreased with increased compressor speed. Those results can be used the basic and fundamental data to design the air-conditioning cycle with inverter scroll compressor.

비단열 모세관 접합방법이 증기압축식 냉동사이클 성능에 미치는 영향 해석 (Analysis of Vapor Compression Refrigeration Cycle Performance Depending on Different Joining Method of Non-adiabatic Capillary Tube)

  • 이대용;박상구;김현정;정지환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권8호
    • /
    • pp.1144-1151
    • /
    • 2009
  • 냉동기는 비단열모세관을 채택하여 사용함으로써 사이클의 효율을 향상시킬 수 있다. 비단열모세관은 모세관과 흡입관을 접합함으로써 둘 사이에 열전달이 일어날 수 있도록 한 장치로서 SLHX 라고 부른다. 두 관을 접합하는 방법은 다양하며 이는 사이클의 성능에 영향을 미칠 수 있다. 본 연구에서는 가장 널리 사용되는 두 가지 접합방법이 냉동사이클에 미치는 영향을 해석하였다. 실험결과 용접형 SLHX의 열저항이 테이프형 SLHX의 열저항 보다 크게 작은 것으로 나타났다. 이를 이용한 사이클해석 결과 용접형 SLHX는 COP 와 냉동능력을 5.09%와 14.77% 향상시키고 테이프형 SLHX는 각각 5.05%와 14.75% 향상시켜 둘 사이의 차이는 매우 작은 것으로 나타났다.

공진특성을 고려한 냉동/공조용 횡자속 선형압축기의 설계 (The Design of a Linear Compressor Based on the Resonance Characteristics for the Air Conditioner)

  • 홍용주;박성제;김효봉
    • 연구논문집
    • /
    • 통권34호
    • /
    • pp.39-46
    • /
    • 2004
  • The compressors in the air conditioner have the role of the pressurization and circulation of the refrigerant. The hermetic reciprocating compressors driven by rotary motor have been used for the air conditioner. The linear compressor has very simple structure and enhancement in the efficiency in comparison to that of conventional reciprocating compressor. The linear compressors are widely used for the small cryogenic refrigerator (below 1 kW), such as the Stirling refrigerator and pulse tube refrigerator. In the cryogenic application, the pressure ratio of the linear compressor is below 1.5, but the linear compressor for the air conditioner should overcome the high pressure ratio and the large pressure difference between the each sides of the piston. The resonance characteristics of the linear compressor has the significant impacts on the power consumption. To minimize the power consumption, the linear compressor should be operated at the resonance point. In the resonance characteristics, the role of the mechanical and gas spring should be considered. In present study, the cycle of the analysis of the vapor compression refrigeration cycle with the different refrigerants (R134a, R4l0a, R600a) and the designs of the linear compressor are performed. The effects of the stiffness of the mechanical spring on the electromagnetic forces would be discussed. Finally, the results show the design specification of the linear compressor for the air conditioner.

  • PDF

R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(2) - 최대 성능계수에 관한 예측과 비교 - (Development of cascade refrigeration system using R744 and R404A - Prediction and comparison on maximum COP(Coefficient of Performance) -)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.189-195
    • /
    • 2011
  • 본 논문은 R744-R404A용 캐스케이드 냉동시스템의 기초 설계자료를 제공하기 위해서 COP 예측 상관식을 제안하고 그 결과를 타 상관식과 비교하였다. 작동변수로는 R404A용 고온사이클과 R744용 저온사이클의 과냉각도와 과열도, 압축기효율, 응축과 증발온도이다. 이에 대한 주요결과를 요약하면 다음과 같다. 다중회귀 분석을 통해 R744-R404A용 캐스케이드 냉동시스템의 성능 예측식을 제안하였고, 그 결과를 타 연구자들의 상관식과 비교하였다. 그 결과 본 연구에서 제안한 성능 예측식은 타 연구자들의 상관식과 일치하지 않았다. 따라서 향후 R744-R404A용 캐스케이드 냉동시스템에 대한 추가 실험 데이터와 본 연구에서 제안한 COP 예측 상관식을 비교하여 그 신뢰성을 확보할 필요가 있다.

吸氣冷却-蒸氣噴射 가스터빈 사이클에 관한 열역학적 연구 (A Thermodynamic Study on Suction Cooling-Steam Injected Gas Turbine Cycle)

  • 박종구;양옥룡
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.77-86
    • /
    • 1992
  • 본 연구에서는 사이클은 터빈 출구로 부터 배출되는 폐열을 최대한 회수하여 얻은 증기를 연소기내에 분사시킴으로써 부가적인 압축기 및 비출력의 상향을 기할수 있다.아울러 폐열이용 암모니아 흡수기 냉동기를 구동하여 압축기 입구 온도를 낮 춤에 의해 열효율 및 비출력의 증대는 물론 대기온도 변화에 따른 기관 성능의 변동을 감소시킬 수 있다.

이산화탄소 액화를 위한 증기 재압축 냉동 공정과 액체질소 냉열을 이용한 냉동 공정의 비교 연구 (Comparative Study on the Refrigeration Processes between Refrigeration Using Vapor Recompression and Refrigeration Using LN2 Cold Heat for the Carbon Dioxide Liquefaction)

  • 노상균
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.549-554
    • /
    • 2023
  • In this paper, three kinds of studies have been completed to obtain highly purified carbon dioxide having more than 7N purity as an electronic grade quality. PRO/II with PROVISION release January 2023 from AVEVA company was used, and Peng-Robinson equation of the state model with Twu's alpha function was selected for the modeling of the cryogenic distillation process. When using LN2 cold heat, we can obtain highest recovery of carbon dioxide as a bottom product for a cryogenic distillation column.

듀얼 냉동사이클을 이용하는 특수목적 자동차용 에어컨 시스템의 냉방성능에 관한 연구 (Investigation on the Performance of Special Purpose Automotive Air-Conditioning System Using Dual Refrigeration Cycle)

  • 서재형;방유마;이무연
    • 대한기계학회논문집B
    • /
    • 제40권4호
    • /
    • pp.213-220
    • /
    • 2016
  • 본 연구의 목적은 열대 지방에서 사용되는 특수목적 자동차용 에어컨 시스템의 냉방성능 특성을 고찰하는 것이다. 이를 위하여 R-134a를 사용하는 듀얼 냉동사이클을 구성하였고 냉매량 및 실내온도를 변화시켜가면서 냉방성능을 비교하였다. 외기온도 $40.0^{\circ}C$에서 듀얼 냉동사이클의 실내 냉각속도 및 압축비(토출압력) 등을 고려하여 최적 냉매량을 1.5kg으로 선정하였다. 실내온도가 증가할수록 냉방부하가 증가하여 $25.0^{\circ}C$에서 $32.5^{\circ}C$로 실내온도를 높일 경우 $15.0^{\circ}C$에 도달하는데 걸리는 시간은 86.5% 증가하였고, $32.5^{\circ}C$에서 $40.0^{\circ}C$로 증가할 경우 38.1% 증가하였다. 또한, 실내온도가 $25.0^{\circ}C$에서 $40.0^{\circ}C$로 증가할수록 냉방용량은 19.1 kW에서 20.5 kW로 7.3% 증가했으나 냉방성능(COP)는 4.67에서 5.1로 7.0%감소하였다.

핫가스 바이패스 밸브를 이용한 R744용 초임계 냉동사이클의 부하제어에 대한 성능 분석 (Performance analysis for load control of R744(carbon dioxide) transcritical refrigeration system using hot gas by-pass valve)

  • 노건상;손창효
    • 한국산학기술학회논문지
    • /
    • 제10권9호
    • /
    • pp.2189-2194
    • /
    • 2009
  • 부분 부하운전시 냉동공조장치의 능력을 조절하기 위해서 핫가스 바이패스 기술을 적용한다. 이 개념은 압축기에서 나온 고온의 냉매증기를 증발기 입구측으로 보내는 것이다. 본 논문에서 질량과 에너지 보존법칙을 근거로 CO2에 대한 핫가스 바이패스 개념을 적용하여 분석한다. 본 논문에서 고려된 운전 변수는 냉동장치의 압축효율, 과열도, 가스냉각기 냉매 출구온도, 증발온도 등이다. 주요결과를 요약하면 다음과 같다. 과열도, 가스냉각기 출구온도, 증발온도는 냉동장치의 COP와 냉동능력에 영향을 미치는 것을 알 수 있다. 따라서 이러한 결과의 면밀한 분석을 통해 R744용 냉동장치를 설계할 필요가 있다.

CO2 수송선 저장탱크의 BOG 측정 실험 및 회수에 관한 연구 (A Study on the Experimental Measurements and Its Recovery for the Rate of Boil-Off Gas from the Storage Tank of the CO2 Transport Ship)

  • 박진우;김동선;고민수;조정호
    • 청정기술
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2014
  • 화석연료로부터 에너지를 얻을 때, 연소반응에 의해 이산화탄소가 생성되어 진다. 이렇게 이산화탄소의 배출이 늘어나게 되면 지구온난화 문제가 더욱 심각해지게 된다. 따라서 이를 방지하기 위한 이산화탄소 포집 및 저장기술(carbon capture and storage, CCS) 개발이 요구되고 있다. 하지만 액화 이산화탄소를 수송 시 여러 문제로 인해 지속적으로 BOG (boil-off gas)가 발생하게 된다. 본 연구에서는 $40m^3$저장 탱크 2대에 액화 이산화탄소를 주입하여 압력변화 및 외부열과 선적, 하역 시 발생하는 BOG의 양과 조성을 30일 간 측정하였다. 측정한 결과 16,040 kg의 BOG가 발생하였으며, 조성은 $CO_2$ 99.95%, $N_2$ 0.05%인 것을 알 수 있었다. 또한 상용성 모사기인 PRO/II with PROVISION 9.2를 이용하여 발생한 BOG를 증기 재압축 냉동사이클을 통해 재액화 하는 전산모사를 수행하였다. 그 결과 냉동사이클의 총 순환유량은 42.07 kg/h, 응축기 설비의 소모량은 48.85 kg/h가 나오는 것을 알 수 있었다.

$CO_2$용 2단압축 1단팽창 냉동 사이클의 성능 분석 (Performance Analysis of a Carbon Dioxide(R744) Two-Stage Compression and One-Stage Expansion Refrigeration Cycle)

  • 노건상;손창효
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.70-75
    • /
    • 2009
  • In this paper, cycle performance analysis of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature in the carbon dioxide two-stage refrigeration cycle. The main results were summarized as follows : The cooling capacity of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, compressor efficiency and gas cooling pressure, but decreases with the increasing mass flowrate ratio and evaporating temperature. The compression work of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, outlet temperature of gas cooler, gas cooling pressure and evaporating temperature, but decreases with the increasing compressor efficiency and mass flowrate ratio. The COP of two-stage compression and one-stage expansion refrigeration system increases with the increasing compressor efficiency, but decreases with the increasing superheating degree, gas cooling pressure, mass flowrate ratio and evaporating temperature. Therefore, superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system have an effect on the cooling capacity, compressor work and COP of this system.

  • PDF