• Title/Summary/Keyword: 증기공동

Search Result 27, Processing Time 0.023 seconds

Evaluation of Pressure History due to Steam Explosion (증기폭발에 의한 압력이력 평가)

  • Kim, Seung Hyun;Chang, Yoon-Suk;Song, Sungchu;Hwang, Taesuk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.4
    • /
    • pp.355-361
    • /
    • 2014
  • Steam explosions can be caused by fuel-coolant interactions resulting from failure of the external vessel cooling system in a new nuclear power plant. This can threaten the integrity of structures, including the nuclear reactor and the containment building. In the present study, an improved technique for analyzing the steam explosion phenomenon was proposed on the basis of previous research and was verified by simulations involving alumina experiments. Also, the improved analysis technique was applied to determine the pressure history of the reactor cavity in accordance with postulated failure locations. The results of the analysis revealed that the effects of vessel side failure are more serious than those of vessel bottom failure, with approximately 70% higher maximum pressure.

Numerical Study of Cavitating flow around Axysimmetric and 2D Body in Cryogenic Fluid (극저온 유체내에서 운행하는 물체 주위의 공동현상 해석에 관한 연구)

  • Lee, Se-Young;Yu, Jung-Min;Lee, Chang-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.309-312
    • /
    • 2007
  • The cryogenic fluid is the propellant for the liquid rocket engine. The design of space launcher vehicle is guided by minimum size and weight criteria, so the turbo pump solicits high impeller speed. Such high speed results in a zone of pressure drop below vapor pressure causing caivtation around inducer blades. The cryogenic fluid has different characters from isothermal fluid like water. The cryogenic fluid has very sensible thermodynamic properties and the phase change undergoes evaporative cooling. So, the developed code has to be modified cavitation modeling and it is added the energy equation for temperature sensitivity.

  • PDF

A Study on the TCE/PCE Removal Using Biofiltration and the Microbial Communities Variation Using DGGE Method (생물 여과를 이용한 TCE/PCE제거 및 DGGE법을 이용한 관련미생물 군집변화에 관한 연구)

  • Kim, Eung-In;Park, Ok-Hyun;Jung, In-Gyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1161-1169
    • /
    • 2008
  • The removals of TCE and PCE vapor with or without a supply of toluene as a primary substrate were compared in a biofiltration process, and the variations of microbial communities associated with the removal were also investigated. As a result of investigations on the removals of TCE/PCE in a biofilter B within which TCE/PCE-acclimated sludge was attached on the surface of media without a supply of primary substrate, and those in another biofilter A where toluene-acclimated sludge was attached with a supply of toluene as a primary substrate, followings were found: (i) parts of microbes responsible to the decomposition of toluene vapor participate in the removal of chlorinated VOCs such as TCE and PCE, and (ii) effective biological removals of TCE and PCE vapor do not necessarily need cometabolism. Sequencing of 16S rDNA obtained from the band profile of DGGE (Denaturating Gradient Gel Electrophoresis), it was confirmed that: (i) uncultured alpha proteobacterium, uncultured Desulfitobacterium, uncultured Rhodobacteraceae bacterium, Cupriavidus necator, and Pseudomonas putida were found to be toluene-decomposing microbes, (ii) alpha proteobacterium HTCC396 is a TCE-removing microbe, (iii) Desulfitobacterium sp. is a PCE-decomposing microbe, and (iv) particularly, uncultured Desulfitobacterium sp. is probably a microbe decomposable not only toluene but also various chlorinated VOC vapor including TCE and PCE.

A Safety Plan for the Pumping Station by Hydraulic Transient Analysis and Demonstration (과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안)

  • Ra, Beyong-pil;Kim, Jin-min;Lee, Dong-keun;Park, Jong-ho;Kim, Kyung-yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.5 s.32
    • /
    • pp.22-28
    • /
    • 2005
  • As the water supply facilities are recently getting larger, the domestic waterworks become multi-regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment plant and water supply/distribution facilities. Although the pumping stations and the pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. In this paper, the intake pumping station is guaranteed by both the computer simulation and the field test analysis. This study is contributed to the safe operation program for the pumping station in which results of the adjustment on the safety plan of the pumping station, the air valve and the valve closing time.

The Plan of Safety for Pump Station through Hydraulic Transient Analysis & Demonstration (과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안)

  • Ra, Beyong-pil;Kim, Jin-man;Park, Jong-ho;Kim, Kyung-yup
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.199-207
    • /
    • 2004
  • Water supply facilities are recently getting larger according as domestic waterworks become multi regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment station and water supply & distribution facilities. Although pumping stations and pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. As a result of this study, a pumping station is guaranteed by the computer simulation and field test analysis. Therefore these are contributed safety operation in pumping station through adjustment of the pumping station safety plan, air valve and valve closing time.

  • PDF

Spectroscopic studies of the high-pressure di-atomic sulfur vapor excited in an optical cavity by microwave discharges (마이크로파 방전에 의한 광학적 공동 안에서 고압 2-원자 황 증71의 분광학적 특성 연구)

  • 김진중;고정태;원동호;홍성호;김정원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.114-115
    • /
    • 2002
  • 마이크로파 방전에 의한 고압 2-원자 황증기 (high-pressure di-atomic sulfur vapor)는 고효율(high luminous efficacy) 및 고연색성 (high color rendering index)의 백색 광원 (source of white light)으로 높이 평가되고 있다 [1]. 소위 무전극 황전등 (elec출odeless sulfur lamp, ESL)으로 알려진 이 발광원은 최고 효율이 173 lm/w 까지 시연되어 알려진 모든 인조 광원 중에서 가장 높은 효율을 보인 혁신적인 광원이다 [2]. (중략)

  • PDF

A Study on the Application of Heat Pump System for Heat Recovery in Dyeing Wastewater (염색폐수 열회수를 위한 열펌프시스템 적용 연구)

  • 장기창;박성룡;이영수;이상남;라호상;박준택
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.57-67
    • /
    • 2002
  • 염색산업은 공정특성상 다량의 증기와 고온수가 필요한 에너지 다소비 산업으로 원가절감에 의한 경쟁력 향상을 위해서는 에너지사용량 절감을 위한 노력이 절실히 요구되는 산업이다. 염색가공공정은 정련, 감량 등 처리공정을 통해 조업, 생산하고 있는데, 이 공정과정에서 다량의 폐수가 발생되고 있으며, 배출된 폐수는 각 공장의 저류조에 집수 되어 공동폐수처리장으로 방류된다.(중략)

  • PDF

Design of Multistage Orifices for PIC System in Nuclear Reactor (원자로 압력 및 체적제어계통의 다단 오리피스 설계)

  • Shin, J.C.
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.17-21
    • /
    • 2015
  • Restriction orifices in the feed and bleed circuit of nuclear power plant are designed using computer program capable of handling multiple hole cascade orifice assembly. Single hole stages of orifice assembly are alternated with multihole stages where necessary. The distance between stages is such that it allows full pressure recovery. The minimum static pressure is higher than vapor pressure at the operating temperature so that cavitation does not occur. Piping sizes are reviewed and increased if necessary to improve rigidity.

Study of the geometry of the flow path of a Pressure Reducing Valve to Suppress the Cavitations (캐비테이션 억제를 위한 감압밸브의 유로 형상에 관한 연구)

  • Park, Woo-Cheul;Kim, Il-Gyum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 2015
  • This study examined the relationship between the shape of the inside of the PRV and the cavitation of the water supply system of an apartment house. In this paper, nine types of PRV with different gaps and shapes were analyzed numerically using a 3D model embedded in the commercial code, ANSYS-CFX. The lowest pressure and the maximum velocity occurred at the narrow gap, which is located at the between the stem and the disk. When the gap size was increased, the vapor volume fraction was always greater than 0, but the vapor volume fraction of the type of expansion pipe approached 0. These results indicate that the cavitation of PRV can be reduced by a shape change to the type of expansion pipe.

부분충수 운전중 잔열제거계통 기능상실사고에 대한 CATHARE2 코드의 민감도 분석

  • 정영종;김원석;장원표
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.48-54
    • /
    • 1996
  • 가압경수로의 부분충수 운전중 RHR 계통의 기능상실시 사고완화를 위해 가압기 manway와 증기 발생기 출구공동 manway를 동시에 개방한 경우에 대한 실험결과를 CATHAHR2 코드를 이용하여 해석하였다. 해석을 통해 이 경우에 발생하는 물리적 현상을 이해하고 이와 같은 과도기에 대해 코드 예측능력을 평가하므로 써, 실제 원전에서 사고시 적절한 사고대응 방안을 강구하는데 참고가 될 수 있도록 해석적 근거를 제시하고자 한다. 연구결과 CATHARE2 코드는 실험을 통해 관측된 주요 물리적 현상들을 타당하게 예측하였으나, 가압기와 밀림관의 DP를 과대 예측하여 원자로 상부공동의 최대압력을 실험보다 약 7kPa 높게 예측하였다. 노심 노출시간도 노심에서 기포율 분포를 비현실적으로 예측하여 실험보다 약 500초 지연되었다. 실험과 코드의 모의결과를 통하여 노심 노출은 중력주입에 의한 냉각수 보충만으로 충분히 회복될 수 있음을 확인하였다. CATHARE2 코드는 비록 상세한 현상들에 대해 다소 불확실성을 내포하였으나, 전반적인 거동분석에는 타당한 것으로 판단된다. CATHARE 코드는 노심에서 계면 마찰력을 줄임으로써 노심의 차압을 개선할 수 있었고, guide 튜브의 위치를 고온관 중심선과 일치시켜 guide 튜브내 액체의 hold-up 기간을 개선할 수 있었으며, 가압기의 계면 마찰력을 증가시켜서 밀림관에서 "plug and clearing" 현상을 모의할 수 있었다.모의할 수 있었다.

  • PDF