• Title/Summary/Keyword: 증강계수

Search Result 42, Processing Time 0.02 seconds

Correlation of the Speed of Enhancement of Hepatic Hemangiomas with Intravoxel Incoherent Motion MR Imaging (간혈관종의 조영증강속도와 복셀내비결집운동 MR영상과의 상관관계)

  • Yang, Dal Mo;Jahng, Geon-Ho;Kim, Hyun Cheol;Kim, Sang Won;Kim, Hyug-Gi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.208-218
    • /
    • 2014
  • Purpose : To evaluate the relationship between the speed of enhancement of hepatic hemangiomas on gadolinium-enhanced MRI and ADC values by using various parameters, including the D, f, $D^*$ and $ADC_{fit}$ on intravoxel incoherent motion (IVIM) MR Imaging. Materials and Methods: The institutional review board approved this retrospective study. A total of 47 hepatic hemangiomas from 39 patients were included (20 men and 19 women). The hemangiomas were classified into three types according to the enhancement speed of the hepatic hemangiomas on gadolinium-enhanced dynamic T1-weighted images: rapid (Type A), intermediate (Type B), and slow (Type C) enhancement. The D, f, $D^*$ and $ADC_{fit}$ values were calculated using IVIM MR imaging. The diffusion/perfusion parameters and ADC values were compared among the three types of hemangiomas. Results: Both the $ADC_{fit}$ and D values of type C were significantly lower than those of type A (P = 0.0022, P = 0.0085). However, for the f and $D^*$, there were no significant differences among the three types. On DWI with all b values (50, 200, 500 and $800sec/mm^2$), the ADC values of type C were significantly lower than those of the type A (P < 0.012). For b values with $800sec/mm^2$, the $ADC_{800}$ values of the type C hemangiomas were significantly lower than those of type B (P = 0.0021). We found a negative correlation between hepatic hemangioma enhancement type and $ADC_{50}$ (${\rho}=-0.357$, P = 0.014), $ADC_{200}$ (${\rho}=-0.537$, P = 0.0001), $ADC_{500}$ (${\rho}=-0.614$, P = 0.0001), and $ADC_{800}$ (${\rho}=-0.607$, P = 0.0001). Therefore, four ADC values of $ADC_{50}$, $ADC_{200}$, $ADC_{500}$, and $ADC_{800}$ were decreased with decreasing enhancement speed. Conclusion: Hepatic hemangiomas had variable ADCs according to the type of enhancement, and the reduced ADCs in slowly enhancing hemangiomas may be related to the reduced pure molecular diffusion (D).

Serviceability Verification Based on Tension Stiffening Effect in Structural Concrete Members (인장증강효과에 기반한 콘크리트 구조 부재의 사용성능 검증)

  • Lee, Gi-Yeol;Kim, Min-Joong;Kim, Woo;Lee, Hwa-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2012
  • This paper is about proposal of a calculation method and development of an analytical program for predicting crack width and deflection in structural concrete members. The proposed method numerically calculate stresses in steel rebar using a parabola-rectangle stress-strain curve and a modified tension stiffening factor considering the effect of the cover thickness. Based on the study results, a calculation method to predict crack width and deflection in reinforced concrete flexural members is proposed utilizing effective tension area and idealized tension chord as well as effective moment-curvature relationship considering tension stiffening effect. The calculation method was applied to the test specimens available in literatures. The study results showed that the crack width and deflections predicted by the proposed method were closed to the experimentally measured data compared the current design code provisions.

Tension Stiffening Effect Considering Cover Thickness in Reinforced Concrete Tension Members (피복두께를 고려한 철근콘크리트 인장부재의 인장증강효과)

  • Lee, Gi-Yeol;Kim, Min-Joong;Kim, Woo;Lee, Hwa-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.791-797
    • /
    • 2011
  • This paper presents the test results of 12 direct tensile specimens to investigate the effect of cover thickness on the tension stiffening behavior in axially loaded reinforced concrete tensile members. Six concrete cover thickness ratios are selected as a main experimental parameter. The results showed that, as cover thickness became thinner, more extensive split cracking along the reinforcement occurred and transverse crack spacing became smaller, making the effective tensile stiffness of thin specimens at the stabilized cracking stage to be much smaller than that of thick specimens. This observation is not implemented in the current design provisions, in which the significant reduction of tension stiffening effect can be achieved by applying thinner cover thickness. Based on the present results, a modified tension stiffening factor is proposed to account for the effect of the cover thickness.

Generation of Resonant Laser for Mg Atomic Beam Cooling by Laser Diode (Laser Diode에 의한 Mg 원자 선속의 냉각용 Laser 발생)

  • 김필수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.50-55
    • /
    • 1991
  • Mg 원자선속의 냉각에 쓰일 diode laser의 특성과 이용가능성을 연구하였다. Mg 원자의 3P2-3D3 천이의 공명선 383.8nm를 얻기 위하여 Mitsubishi사의 ML형 laser diode를 택하여 주입전류와 온도를 변화시키고, 회절격자를 써서 767.6nm의 laser 광을 얻은 후 LiIO3 결정에 의해 383.8nm인 제2조화파를 생성하였다. Ring cavity 내에서 기본파가 공명할 때 증강계수는 15이었다.

  • PDF

Performance Change in Medical X-ray Image Intensifier Tube Depending on Terms of Use (사용년한에 따른 의료용 X선 영상증강장치의 성능변화)

  • Kim, Min-Jung;Ahn, Sung-Min;Cho, Young-Kwon;Choi, Jung-Hyun;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.7
    • /
    • pp.253-258
    • /
    • 2010
  • The image intensifier tube that is clinically used gets changed depending on its terms of use. As the brightness gets deteriorated and the performance gets decrease, the X-ray output needs to be increased to maintain the identical diagnosis outcome. As a consequence, the patients are exposed to the increased radiation. Since not many accurate studies have been made, this study measured the conversion factor and resolution depending on the use of the devices that were currently used in Korea. When comparison was made with a device with less than 1 year-use, the conversion factor of a device with 6 year-use got decreased up to 25% while its resolution was reduced from 3.4 lp/mm to 2.5 lp/mm. Such outcome highlights the necessary measures to be supplemented as the increased terms of use implied also the increased radiation exposure among the patients as well as difficulty to conduct an accurate exam.

A Method to Quantify Breast MRI for Predicting Tumor Invasion in Patients with Preoperative Biopsy- Proven Ductal Carcinoma in Situ (DCIS) (유방 자기공명영상법을 이용한 수술 전 관상피내암으로 진단된 환자의 침윤성 유방암을 예측하는 정량적 분석법)

  • Ko, Myung-Su;Kim, Sung Hun;Kang, Bong Joo;Choi, Byung Gil;Song, Byung Joo;Cha, Eun Suk;Kiraly, Atilla Peter;Kim, In Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.73-82
    • /
    • 2013
  • Purpose : To determine the quantitative parameters of breast MRI that predict tumor invasion in biopsy-proven DCIS. Materials and Methods: From January 2009 to March 2010, 42 MRI examinations of 41 patients with biopsy-proven DCIS were included. The quantitative parameters, which include the initial percentage enhancement ($E_1$), peak percentage enhancement ($E_{peak}$), time to peak enhancement (TTP), signal enhancement ratio (SER), arterial enhancement fraction (AEF), apparent diffusion coefficient (ADC) value, long diameter and the volume of the lesion, were calculated as parameters that might predict invasion. Univariate and multivariate analyses were used to identify the parameters associated with invasion. Results: Out of 42 lesions, 23 lesions were confirmed to be invasive ductal carcinoma (IDC) and 19 lesions were confirmed to be pure DCIS. Tumor size (p = 0.003; $6.5{\pm}3.2$ cm vs. $3.6{\pm}2.6$ cm, respectively) and SER (p = 0.036; $1.1{\pm}0.3$ vs. $0.9{\pm}0.3$, respectively) showed statistically significant high in IDC. In contrast, E1, Epeak, TTP, ADC, AEF and volume of the lesion were not statistically significant. Tumor size and SER had statistically significant associations with invasion, with an odds ratio of 1.04 and 22.93, respectively. Conclusion: Of quantitative parameters analyzed, SER and the long diameter of the lesion could be specific parameter for predicting invasion in the biopsy-proven DCIS.

Two-Stage Contrastive Learning for Representation Learning of Korean Review Opinion (두 단계 대조 학습 기반 한국어 리뷰 의견 표현벡터 학습)

  • Jisu Seo;Seung-Hoon Na
    • Annual Conference on Human and Language Technology
    • /
    • 2022.10a
    • /
    • pp.262-267
    • /
    • 2022
  • 이커머스 리뷰와 같은 특정 도메인의 경우, 텍스트 표현벡터 학습을 위한 양질의 오픈 학습 데이터를 구하기 어렵다. 또한 사람이 수동으로 검수하며 학습데이터를 만드는 경우, 많은 시간과 비용을 소모하게 된다. 따라서 본 논문에서는 수동으로 검수된 데이터없이 양질의 텍스트 표현벡터를 만들 수 있도록 두 단계의 대조 학습 시스템을 제안한다. 이 두 단계 대조 학습 시스템은 레이블링 된 학습데이터가 필요하지 않은 자기지도 학습 단계와 리뷰의 특성을 고려한 자동 레이블링 기반의 지도 학습 단계로 구성된다. 또한 노이즈에 강한 오류함수와 한국어에 유효한 데이터 증강 기법을 적용한다. 그 결과 스피어먼 상관 계수 기반의 성능 평가를 통해, 베이스 모델과 비교하여 성능을 14.03 향상하였다.

  • PDF

Analysis of mediating effects of presence, emotional attachment, and focus of attention for augmented reality immersion - In the case of augmented reality game Pokémon Go users (증강현실 몰입에 대한 현존감 및 정서적 애착과 주의집중의 매개효과 연구 - 증강현실 게임 포켓몬 고 이용자를 사례로)

  • Han, Yoon Jung
    • Journal of the HCI Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.27-35
    • /
    • 2017
  • This study aims to investigate the influence of engagement of augmented reality game on immersion. The relationship between engagement and flow was examined through the mediating effects of emotional attachment and focus of attention on presence and the mediating effects of presence on flow. In order to verify the research hypothesis, online questionnaire was conducted with the consent of $Pok\acute{e}mon$ Go game user group. The questionnaire items were translated from the Augmented Reality Immersion Questionnaire. A total of 200 questionnaires were collected and used for analysis. Using the SPSS 23.0 program and the Mplus 7.0 program, the reliability of the scale was confirmed through the Cronbach's coefficient and the causal relationship and the mediating effects were verified by path analysis. As a result, there was no direct causal relationship between engagement and flow. However, causal relationship was evident when emotional attachment and focus of attention were mediated in the process of engagement in augmented reality game. In conclusion, systematic explanations of participant's emotional attachment and attentional state as a main factor in the process of participating in the augmented reality game involvement, reveal the elements to be noticed by the augmented reality game.

Modeling of Tension Stiffening Effect Based on Nonlinear Bond Characteristics in Structural Concrete Members (비선형 부착 특성에 기반한 철근콘크리트 부재의 인장증강효과 모델)

  • Lee, Gi-Yeol;Ha, Tae-Gwan;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.745-754
    • /
    • 2007
  • This paper presents a unified modeling technique for tension stiffening effect in structural concrete members. The model is mathematically derived from the bond stress-slip relationships which account for splitting crack. The relationships in CEB-FIP Model Code 1990 and Eurocode 2 are employed together with the assumptions of a linear slip distribution along the interface and the uniform condition of concrete tensile contribution for the mid section of cracked member at the stabilized cracking stage. With these assumptions, a model of tension stiffening effect is proposed by accounting for the force equilibrium and strain compatibility condition associated to the steel strain and concrete contribution by bond stress. The model is applied to the test results available in literatures, and the predicted values are shown to be in good agreement with the experimentally measured behavior.

Correlation between Reverse Redistribution and Subendocardial Myocardial Infarction Observed in Myocardial Contrast Echocardiography (역재분포 소견과 심근조영 심초음파에서 보인 심내막하경색과의 관계)

  • Kim, Sung-Eun;Choe, Won-Sick;Kwan, Jun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.228-233
    • /
    • 2000
  • Purpose: The aim of this study is to better understand the pattern and nature of reverse redistribution (RR) in myocardial perfusion imaging. Materials and Methods: In consecutive 20 acute myocardial infarction (MI) patients, frequency of RR was correlated with that of subendocardial MI that was detected by myocardial contrast echocardiography (MCE). RR was judged to be present when there was more than one grade of worsening in perfusion at 24 hr delayed images compared with the initial rest images. MCE evaluated the significant lack of opacification in the subendocardial myocardium relative to the subepicardial myocardium to suggest the subendocardial MI. Kendall's nonparametric correlation coefficiency was calculated. Results: Concordant cases were 15 of 20 (75%) and correlation was statistically significant (p=0.0285). Conclusion: Our results suggested that RR was correlated with MCE-detected nontransmural MI.

  • PDF