• Title/Summary/Keyword: 중형 폐기물 소각로

Search Result 7, Processing Time 0.018 seconds

Optimal Operation of Medium Sized Incinerator to Minimize PCDD/Fs Emission (중형 소각로 다이옥신 배출 저감을 위한 최적 운전인자)

  • Yoo, Dong-Joon;Koo, Ja-Kong;Jeong, Seung-Ik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.4
    • /
    • pp.44-49
    • /
    • 2013
  • An establishment of dioxin-reduction operating skill for medium sized incineration facility is urgently needed in Korea with nearly 90% of medium sized incineration. Using lattice stoker incineration processing the capacity of 20 tons industrial general waste per day, similar properties of the household waste, dioxin-reduction is derived in optimum operating condition and parameters. As a result, CO haunting which is the minimization of frequency is found as the major parameter to minimize dioxin.

A Study on Characteristics of Incinerator for Medical Wastes (감염성 폐기물 처리용 소각로 특성에 대한 연구)

  • 채호준;조석연;박용한;장필수
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.471-472
    • /
    • 2003
  • 국민의 보건의식이 높아짐에 따라서, 병원에서 배출되는 감염성 폐기물의 안정적 처리에 대한 요구가 높아지고 있다. 감염성 폐기물 처리방법으로는 가압멸균과 산화소각 및 건류소각이 있는데, 본 연구 목적은 100%멸균이 보장되는 중형 산화소각을 설계하고 이의 운영특성을 파악하는데 있다. 감염성 폐기물은 일정규격의 상자에 담아서 배출되며, 저온에서 이송과 저장이 이루어지며, 소각로 투입시에도 상자를 파손하지 않고 투입되어야 하는 등의 엄격한 규정에 따라서 소각하여야 한다. 본 연구는 이러한 감염성 폐기물처리 법규 및 감염성 폐기물의 연소 특성을 파악하여 소각로 설계의 기본자료로 활용하였다. (중략)

  • PDF

Present conditions of air pollution emissions from incinerations (중ㆍ소형 소각시설에서의 대기오염물질 배출 현황)

  • 김창환;황의현;김신도
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.331-332
    • /
    • 2003
  • 과거 우리나라에서는 증가하는 폐기물 양을 처리하기 위하여 매립에서 소각으로 정책이 바뀌어 가면서 전국적으로 중ㆍ소형 폐기물 소각시설의 설치를 장려하여 그 결과 2001년 6월말에는 전국에서 운영중인 소각시설 8,173개 시설 중에서 중ㆍ소형 소각시설이 전체 소각시설의 98.6%를 차지하는 8,059개 시설로 증가하였다. 이 중 소형(0.2ton/hr 미만) 소각시설이 7,697개 시설로 94.2%, 중형(0.2ton/ hr∼2ton/hr) 소각시설은 362개 시설로 4.4%를 차지하고 있어 전국적으로 소형 소각시설이 산재해 있다는 것을 알 수 있다. (중략)

  • PDF

Development of Hybrid type Air Pollution Control System with Air Turbine & Bearing type Atomizer (무마찰 공기베어링을 이용한 고속회전 미세액적 분사장치를 갖는 하이브리드형 고효율 대기오염 방지시설 개발)

  • 김정원;위판석;김진용;정원문;박영옥;박상신
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.53-54
    • /
    • 2003
  • 현대 산업사회가 다양해짐에 따라 발생되는 생활폐기물의 형태도 다양화되었고 발생폐기물의 성상은 연소가 어려운 난분해성 폐기물로 발열량이 높아지고 있다. 이러한 폐기물의 처리를 위한 소각설비는 폐기물 처리형태에 따라 대형의 도시 쓰레기 소각장이나 지자체의 중형급 소각장, 발생원 단위의 소형 소각장으로 구분하여 처리하고있다. 기존 중ㆍ대형 소각로의 유해가스 처리시설은 일반적으로 냉각설비와 가스상 처리설비, 입자상 처리설비 등으로 구성되는데 반해, 소형 소각로는 싸이클론 방식만으로 구성되어 입자상 물질만을 처리하였으나, 최근에 들어서 관련법규가 개정되어 소형 소각로에서도 입자상 오염물질뿐만 아니라 HCl 및 SOx 등과 같은 산성가스류와 다이옥신 등의 배출농도를 규제함에 따라 가스상 오염물질도 처리하는 방안을 도입하고 있는 추세이다. (중략)

  • PDF

A Characteristics of Hg, Pb, As and Se Emitted from Small and Medium Size Waste Incinerator Stacks (중.소형 폐기물 소각시설에서 배출되는 수은, 납, 비소, 셀렌 배출특성)

  • Lee, Han-Kook;Moon, Bu-Shik;Lee, Dong-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1205-1214
    • /
    • 2005
  • This study was carried out to investigate the emission characteristics of volatile metals(Hg, As, Se) and semi volatile metals such as Pb from small and medium size municipal solid waste incinerators(MSWIs). The concentrations of Hg, Pb, As and Se in emission gas from small size waste incinerators were higher than those of medium size waste incinerators. This is probably due to less air pollutant control devices and high emission gas temperature of the small size waste incinerators relative to the medium size waste incinerators. Emission gas temperature from small and medium size waste incinerators were divided into 2 groups. The first group was about $100^{\circ}C$ and the second roup in the range of $400{\sim}700^{\circ}C$. The concentrations of emission gas at the second group were Hg $70.43\;{\mu}g/Sm^3$, Pb $0.94\;{\mu}g/Sm^3$, As $9.83\;{\mu}g/Sm^3$ and Se $5.05\;{\mu}g/Sm^3$. The concentrations of Hg, Pb, As and Se at the first group were lower than those found at the second group. Besides, the removal efficiencies of Hg in medium size waste incinerators were $55.2{\sim}95.9%$. Emission gas temperature reduction from waste heat boiler(WHB) contribute to control of Hg. Based on above results, we postulate that the temperature of flue gas should play a very important role in volatile metal control in small and medium size MSWIs. In order to improve the volatile metals removal efficiency, the temperature of cooling system must be controlled and the air pollution control device should be operated properly.

Characteristics of Hg, Pb, As, Se Emitted from Medium Size Waste Incinerators (중형폐기물 소각시설의 수은, 납, 비소, 셀렌 배출특성)

  • Lee Han-Kook
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.8-18
    • /
    • 2006
  • The aim of this study is to evaluate the emission characteristics of mercury, lead, arsenic, and selenium from medium size municipal solid waste incinerators(MSWIs) in Korea. The concentrations of mercury, lead, arsenic, and selenium emitted from medium size MSWI stack were $2.67\;{\mu}g/Sm^3,\;0.38\;mg/Sm^3,\;1.33\;{\mu}g/Sm^3,\;0.28\;{\mu}g/Sm^3$, respectively. The concentration levels of mercury, lead, arsenic in flue gas from medium size MSW incinerator stacks selected were nearly detected under the Korea criteria level. Removal efficiencies of mercury, lead, arsenic, and selenium in waste heat boiler(WHE) and cooling tower(CT) were $90.36\%,\;69.76\%,\;43.04\%,\;40.64\%$, respectively. In general, the removal efficiencies of mercury and lead in WHE were higher than those of arsenic and selenium in WHE. Emission gas temperature reduction from waste heat boiler(WHB) and cooling tower(CT) can control mercury and lead of medium size MSWIs. To evaluate the relationship between mercury, lead, arsenic, selenium of fly ash and those of flue gas, it was carried out to correlation analysis of each metal concentration in the fly ash and in the flue gas from medium size MSWIs. From the correlation analysis, the coefficients of mercury, lead, arsenic, and selenium were 0.61, -0.38, 0.87, 0.28, respectively. The results of correlation analysis revealed that it should be highly positive to the correlation coefficients of mercury and arsenic in the fly ash and those of the flue gas emitted from medium size MSWIs. As it were, the concentrations of mercury and arsenic of flue gas from medium size MSWIs are high unless mercury and arsenic in fly ash are properly controlled in dust collection step in medium size MSWIs. It was also concluded that mercury, lead, arsenic, and selenium from MSWIs stacks could be controlled by waste heat boiler(WHE) and dust collecting step in medium size MSWIs.