• Title/Summary/Keyword: 중심 X선

Search Result 78, Processing Time 0.026 seconds

Grid Angle Optimization and Grid Artifact Reduction in Digital Radiography Images Based on the Modulation Model (디지털 방사선 영상에서 그리드 각도의 최적화와 변조 모델에 기초한 그리드 왜곡의 제거)

  • Kim, Dong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.30-41
    • /
    • 2011
  • In order to obtain more clear x-ray images, an antiscatter grid, which can absorb the scattered rays, is employed. In the high-resolution direct digital radiography, however, the artifacts due to the grid are visible. In this paper, within the methods of obtaining x-ray digital images by employing the rotated grids for the facility of grid artifact reduction, the previous work, where the frequencies of the artifact components on the boundary, is further analyzed and extended, and a min-max optimization for a given grid density is proposed. For practical grid densities, appropriate grid angles are provided and a grid artifact reduction algorithm is proposed for the appropriate grid angles. The proposed algorithm is tested for real x-ray digital images with a comparison, and can remove the grid artifacts while maintaining the resolution of the original image.

Evaluation of Geometric Correspondence of kV X-ray Images, Electric Portal Images and Digitally Reconstructed Radiographic Images (kV X선 영상, 전자조사문 영상, 디지털화재구성 영상 간 기하학적 일치성 평가)

  • Cheong, Kwang-Ho;Kim, Kyoung-Joo;Cho, Byung-Chul;Kang, Sei-Kwon;Juh, Ra-Hyeong;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.118-125
    • /
    • 2007
  • In this study we estimated a geometric correlation among digitally reconstructed radiographic image (DRRI), kV x-ray image (kVXI) from the On-Board Imager (OBI) and electric portal image (EPI). To verify geometric correspondence of DRRI, kVXI and EPI, specially designed phantom with indexed 6 ball bearings (BBs) were employed. After accurate setup of the phantom on a treatment couch using orthogonal EPIs, we acquired set of orthogonal kVXIs and EPIs then compared the absolute positions of the center of the BBs calculated at each phantom plane for kVXI and EPI respectively. We also checked matching result for obliquely incident beam (gantry angle of $315^{\circ}$) after 2D-2D matching provided by OBI application. A reference EPI obtained after initial setup of the phantom was compared with 10 series of EPIs acquired after each 2D-2D matching. Imaginary setup errors were generated from -5 mm to 5 mm at each couch motion direction. Calculated positions of all center positions of the BBs at three different images were agreed with the actual points within a millimeter and each other. Calculated center positions of the BBs from the reference and obtained EPIs after 2D-2D matching agreed within a millimeter. We could tentatively conclude that the OBI system was mechanically quite reliable for image guided radiation therapy (IGRT) purpose.

  • PDF

Sonoluminescence Phenomeana and Their Application (소노루미네센스 현상과 그 응용)

  • 곽호영
    • Journal of the KSME
    • /
    • v.35 no.8
    • /
    • pp.725-736
    • /
    • 1995
  • 소노루미네센스(SL)현상은 액체 내에서 초음파에 동기화되어 진동하는 미소기포$~10\mu\textrm{m}$)가 수축할 때 기포내부의 온도가 고온이 됨에 따라 기포중심으로부터 빛이 나오는 현상을 말한다. 단일기 포가 초음파에 가진 될 경우 그 스펙트럼이 X선에 가까운 것임이 밝혀질뿐더러 촉매물 질의 개발이나 활성화, 고분자 합성뿐만 아니라 용액 내에서의 불순물 제거 등에 대한 응용의 가능성이 속속 발견되자, 현재 과학계뿐만 아니라 일반 매스컴에서도 화제의 대상이 되고 있다. SL현상은 원자당 $10^{11}eV$ 에 해당되는 초음파 에너지의 파장이 0.19.mu. 이하인 X선, 즉 6eV 이상의 광자에너지로 증폭됨에 따라 기포수축시 기포내 가스의 온도가 수만 도에 이르는 것, 레이저에 상응하는 광펄스 폭(50 ps)과 초음파에 동기되어 현존하는 최상의 수정시계에 필적하는 SL펄스의 규칙성, 기포수축시의 $10^{10}W/m^{2}$에 해당되는 열의 방출과 10억분의 수 초 동안에 $10^{4}K$의 고온상태에서 200K 정도의 저온상태로 바뀜에 따른 급격한 냉각속도 등 으로 특징지어질 수 있다. 이 글에서는 현재 실험을 통하여 알려진 SL에 관한 현상의 특징과 응용에 대해 구체적으로 기술하였다.

  • PDF

용접잔류응력과 그 제어

  • 암전광정
    • Journal of Welding and Joining
    • /
    • v.3 no.2
    • /
    • pp.64-73
    • /
    • 1985
  • X선응력측정법은 결정의 각자간 거리를 표점으로 하는 각자변형도를 X선회절현상을 이용하여 직접규정하여 응력을 구하는 것이다. 따라서 비교재의 교정곡선으로 부터 간접적으로 응력을 측 정하는 자기법이나 초음파법 등의 비파괴측정법에 비하여 X 선응력측정법은 잔류응력과 같은 내부응력의 비파괴측정법에 알맞고 지금까지 많은 연구자에 의하여 용접부에 적용시키기 위한 시도가 행해졌었다. 앞서 말한 국제회의에서도 X선응력측정법을 취급한 논문이 6편이고 그 가운 데서 3편이 용접구조물 또는 이음부에 이 방법을 적용한 것이다. 그래서 본고에서는 먼저 용접 잔류응력의 발생기구와 계산법, 측정법에 대하여 기술하겠다. 똔 잔류응력이 용접이음부의 파괴 강도 및 용접균열에 미치는 영향, 용접잔류응력의 대책과 이용법에 대하여 일본에서의 연구를 중심으로 소개하겠다.

  • PDF

Spatial Dose Distribution for Diagnostic X-ray Examination within X-ray Room using the MCNPX Program (MCNPX 프로그램을 통한 일반 X선 검사 시 검사실 내 공간선량분포)

  • Lee, Dong-yeon;Lee, Jin-soo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.298-306
    • /
    • 2015
  • This study is the material of the additional filter(Cu, Ni, CaWO4, Gd+Ba) being used when the diagnosis X-ray was varied to evaluate the spatial dose distribution accordingly. And it suggest to find a suitable material. Experiments using MCNPX program based on the Monte Carlo simulation method was carried out by selecting the chest and abdomen taken. As a result, each material per dose, the average scatter dose is approximately 62%, 100 cm radius of the point of the simulated body surface exposure dose and 50 cm radius centered on the point average about 47%. It is determined that an Al material is currently available in accordance with the result to be replaced by Cu, Ni material is sufficient. With just the thickness due to the difference in the atomic number and density adjusted to be about one-tenth of the Al it will be suitable.

자기 공명 영상술의 원리와 최근 연구 현황

  • 조장희;김영근
    • 전기의세계
    • /
    • v.38 no.8
    • /
    • pp.19-25
    • /
    • 1989
  • 현재 전세계적으로 퍼져있는 NMR-CT 시스템의 수를 살펴보면 약 370여기가 설치.운영되고 있으며 앞으로 계속 늘어날 전망이다. 국내에서는 1988 한국과학기술원과 금성통신에 의해 자체 개발된 2.0 Tesla 강자장 시스템이 최초로 서울대학병원에 설치 가동된 이래 여러병원에서 시스템들이 설치중에 있다. 첨단의로 진단장치로서의 핵자기 공명 영상법은 그 영상을 통하여 기존의 진단 장치보다 우월함을 증명하고 있으며 초음파 검사나 동위원소 검사 및 X선 전산화 단층 촬영술들을 장점을 두루 지니면서 그 영상법의 다양성 때문에 앞으로의 연구 및 발전에 대한 전망은 아주 밝다고 할 수 있다. 따라서 앞으로의 종합 영상 의료 진단 장치는 이 NMR-CT가 중심이 되어 발전할 것이라고 단언해도 무리한 생각은 아닐 것이다.

  • PDF

The development of digital camera for the medical DF instrument (의료용 DF 장비의 디지털 카메라 개발)

  • 김용민;이성운;구기현;김진용;김승식;문지영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.76-77
    • /
    • 2003
  • Digital Radiograpy & Fluoroscopy(DRF 또는 DR 또는 DF)는 cone beam을 이용하여 인체를 투과한 X선을 영상증배관(Image Intensifying Tube: IIT)을 통하여 가시광선으로 변환시킨 후 영상을 카메라로 보내고, 이곳에서 발생한 영상정보를 디지털로 처리하여 모니터를 통해 눈에 보이는 영상으로 만드는 방법으로 IIT에 기초한 디지털 방사선 촬영술이라고도 한다. DF 방법은 즉시 영상 표시와 진단이 가능하기 때문에 즉시성이 요구되는 심장이나 두복부 등의 순환기 분야에서 DSA(Digital Subtraction Angiography) 장비로 이용되고 있고, 순환기뿐만 아니라 위를 중심으로 한 소화관(식도, 위, 소장, 대장, 직장)의 분야에서 적용 가능하다. (중략)

  • PDF

Entrance Surface Dose according to Dose Calculation : Head and Wrist (피폭선량 산출을 통한 피부입사선량 계산: 머리 및 손목을 중심으로)

  • Sung, Ho-Jin;Han, Jae-Bok;Song, Jong-Nam;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.305-312
    • /
    • 2016
  • This study were compared with the direct measurement and indirect dose methods through various dose calculation in head and wrist. And, the modified equation was proposed considering equipment type, setting conditions, tube voltage, inherent filter, added filter and its accompanied back scatter factor. As a result, it decreased the error of the direct measurement than the existing dose calculation. Accordingly, diagnostic radiography patient dose comparison would become easier and radiogrphic exposure control and evaluation will become more efficient. The study findings are expected to be useful in patients' effective dose rate evaluation and dose reduction.

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography (방사선 미세컴퓨터단층촬영을 이용한 네 종류 file systems의 중심유지능에 관한 비교)

  • Ko, Hye-Suk;You, Heyon-Mee;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to compare the centering abilities of four root canal instrument systems and the amounts of dentin removed after root canal shaping using them. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}$ curvature were scanned using X-ray micro-computed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n = 10 per group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with Profile (Group 2), ProTaper (Group 3) or K3 system (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Scanned images were processed to reconstruct three-dimensional images using three-dimensional image software and the changes of total canal volume were measured. Pre-and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were com pared. For each level, centering ratio were calculated using Adobe Photoshop 6.0 and image software program. ProTaper and K3 systems have a tendency to remove more dentin than the other file systems. In all groups, the lowest value of centering ratio at 3 mm level was observed. And except at 3 mm level, ProTaper system made canals less centered than the other systems (p < 0.05).