• Title/Summary/Keyword: 중성자 조사량

Search Result 56, Processing Time 0.022 seconds

A Study on Barkhausen Noise of Reactor Pressure Vessel Materials Irradiated by Neutrons (중성자에 조사된 원자로 압력용기 재료의 Barkhausen 노이즈에 관한 연구)

  • Ok, Chi-Il;Kim, Jang-Whan;Park, Duck-Gun;Hong, Jun-Hwa;Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.6
    • /
    • pp.477-483
    • /
    • 1998
  • Hysteresis loop, Barkhausen noise(BN), and hardness were measured in the neutron irradiated RPV steel for various fluence, irradiated dose up to $10^{18}n/cm^2$. The coercivity, remanence and maximum induction of neutron irradiated samples did not change significantly, but the BNA and BNE were decreased as the neutron irradiation increased. The changes of BNE and BNA were characterized by three stages with respect to neutron dose. The BNA and BNE were decreased with an increase of neutron dose to $10^{12}n/cm^2$, and remained nearly constant up to $10^{16}n/cm^2$, then were decreased rapidly with an increase of the neutron dose above $10^{16}n/cm^2$. On the other hand, the hardness was observed revesely with the change of BNA and BNE.

  • PDF

EFFECT OF NEUTRON AND GAMMA IRRADIATION ON THE GERMINATION OF DIPLOID AND TETRAPLOID RYE SEEDS (중성자 및 감마선의 조사가 이배체 및 사배체 호맥의 종자의 발아 및 성장에 미치는 영향)

  • YIM, Kyong Bin
    • Journal of Plant Biology
    • /
    • v.6 no.3
    • /
    • pp.6-14
    • /
    • 1963
  • YIM, Kyong Bin (Coll. of Agriulture, Seoul National University) Effect of neutron and gamma irradiation on the germination of diploid and tetraploid rye seeds. Kor. Jour. Bot. VI(3):6-14, 1964. Tetraploid rye, Secale cereale 4x, was more tolerant to fast nuetron than diploid rye. Root growth was more suppressed than was seedling height in both diploid and tetraploid rye. A stimmulative effect on the dry weight of the shoot could be observed at very low doses of irradiation. It was the fact that the lower the moisture content of the seeds, the higher the radiosensitivity. Concerning seedling height growth, the effectiveness ratio of N/X equalled about 20.0 in diploid rye and about 18.2 in tettraploid rye, when the 50% dose ratios is used for this quotient calculaiton.

  • PDF

애폭시수지계 중성자 차폐제의 차폐능에 관한 연구

  • 조수행;최병일;신형준;노성기;박현수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.571-576
    • /
    • 1998
  • 방사성물질의 수송용기 등에 사용되는 에폭시수지계 중성자 차폐재를 제조하였다 기본물질은 재질(KNS-102) 및 수소 첨가된 비스페놀 A힘(KNS-106) 그리고 패놀-노블락형 에폭시수지 (KNS-611)이며, 첨가제로는 수산화알루미늄 및 탄화붕소이다. 이들 중성자 차폐재들은 유동성이 좋아 수송용기와 같은 복잡한 구조에 사용할 수 있다. 제조된 중성자 차폐재들을 방사선 조사선 량에 대한 영향과 가압경수로 사용후핵연료_ 28다발을 수송할 수 있는 수송용기에 적용하여 차폐능 평가를 수행하였다 0.7 MGy 까지 중성자 차폐재들은 방사선 조사선량의 증가에 따라 중성자 차폐재의 거시적 제거 단면적($\Sigma$$_{R}$)은 약간 증가하는 경향을 나타내었으며, 수송용기에 적용하여 ANISN 전산코드로 차폐능 평가를 수행한 결과 정상수송시 중성자 차폐재의 두께가 12 cm 이상일 때 수송용기 반경방향표면에서 최대 방사선량율은 168 ~ 214 $\mu$Sv/h로 나타났으며, 수송용기 표면에서 100 cm 지점에서의 최대 방사선량율은 74 ~ 93 $\mu$Sv/h로 나타났다. 이들은 모두 관련된 법규들에서 규정된 최대 허용방사선량율을 만족하는 것으로 나타났다.

  • PDF

Neutron fluence measurement at HANARO using fluence monitor method (Fluence Monitor를 이용한 HANARO 노심 내 중성자 플루언스 측정)

  • Lee, Seung-Kyu;Jo, Kwang-Ho;Choo, Kee-Nam;Park, Jin-Suk;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.200-208
    • /
    • 2011
  • The neutron fluence measurement and evaluation technology is very important for material irradiation test. The most essential technology in this study is the neutron irradiation evaluation method using a fluence monitor. The fluence monitors were fabricated with metal wires of the purity ${\geq}$ 99.9%, whose dimensions were 0.1mm diameter, about 3 mm length, and around 150-200 ${\mu}g$ mass range. Three wire samples (Fe, Ni, Ti) were prepared for one irradiation aluminum capsule. Five capsules were irradiated in the OR5 hole of the HANARO reactor at 30 MW power for about 25 days. After irradiation tests, radiation activities were measured with the high purity germanium (HPGe) detector. The reaction rates were calculated by using the measured radiation activity data, and then neutron fluence were obtained from the reaction rates and the weighted neutron cross section with calculated neutron spectrum at the fluence monitor position.

A Study on Embrittlement of Fast Neutron-irradiated Nuclear Reactor Pressure Vessel Steels at Room- and Liquid Nitrogen-temperature (상온 및 액체질소 온도에서 고속 중성자 조사된 원자로 압력 용기의 취화 현상에 관한 연구)

  • Kim, H.B.;Kim, H.S.;Kim, S.K.;Shin, D.H.;Yu, Y.B.;Ko, J.D.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.142-147
    • /
    • 2005
  • The embrittlement of fast neutron-irradiated reactor pressure vessel (RPV) steels was investigated by X-ray diffraction patterns at room temperature and $M\ddot{o}ssbauer$ spectroscopy at room- and liquid nitrogen-temperature. Neutron fluence on the samples were $10^{12},\;10^{13},\;10^{14},\;10^{15},\;10^{16},\;10^{17},\;10^{18}\;n/cm^2$. The X-ray diffraction patterns showed that the structure of the neutron unirradiated sample was bcc type, where as but the neutron irradiated samples with the fluence higher than $10^{17}\;n/{\cal}cm^2$ were so severely damaged, that bcc type structure disappeared. The $M\ddot{o}ssbauer$ spectra of all samples showed superposition of two or more sextets. In this paper all $M\ddot{o}ssbauer$ spectra were fitted by three set of sextet. The isomer shift and quadrupole splitting values were found around zero. At liquid nitrogen temperature, magnetic hyperfine field and absorption area increase rapidly S 1 sextet in the samples of $10^{17}\~10^{18}\;n/{\cal}cm^2$ neutron fluences. And at room temperature, magnetic hyperfine field and absorption increased rapidly at SI sextet in the samples of $10^{17}\~10^{18}\;n/{\cal}cm^2$ neutron fluences. This rapid increase of magnetic hyperfine field and absorption area were inferred to be caused by the change of $^{56}Fe,\;^{55}Mn$ into $^{57}Fe$ due to by neutron irradiation.

The Estimation of Neutron Fluence in Nuclear Reactor Vessel Materials by the Analysis of Ultrasonic Characteristics (초음파특성 분석에 의한 원자로 재료의 중성자 조사량 예측)

  • Lee, Sam-Lai;Chang, Kee-Ok;Kim, Byoung-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.3
    • /
    • pp.307-312
    • /
    • 2001
  • Ultrasonic signals from Charpy impact test specimen have been analyzed in order to evaluate the integrity of reactor pressure vessel. Base and weld metal that were extracted from reactor vessel doting plant outages according to the schedule of the surveillance test required by the related regulations have been used and the ultrasonic test parameters including velocity, attenuation, etc. showed a close correlations with the amount of neutron irradiation for base metal, relatively homogeneous materials. This result showed certain possibility where a nondestructive method could be used to predict the fluence of the Irradiation due to neutron in nuclear reactor vessel materials.

  • PDF

Neutron Fluence Evaluation for Reactor Pressure Vessel Using 3D Discrete Ordinates Transport Code RAPTOR-M3G (3차원 수송계산 코드(RAPTOR-M3G)를 이용한 원자로 압력용기 중성자 조사량 평가)

  • Maeng, Young Jae;Lim, Mi Joung;Kim, Byoung Chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.107-112
    • /
    • 2014
  • The Code of Federal Regulations, Title 10, Part 50, Appendix H requires surveillance program for reactor pressure vessel(RPV) that the peak neutron fluence at the end of the design life of the vessel will exceed $1.0E+17n/cm^2$ (E>1.0MeV). 2D/1D Synthesis method based on DORT 3.1 transport calculation code has been widely used to determine fast neutron(E>1.0MeV) fluence exposure to RPV in the beltline region. RAPTOR-M3G(RApid Parallel Transport Of Radiation-Multiple 3D Geometries) performing full 3D transport calculation was developed by Westinghouse and KRIST(Korea Reactor Integrity Surveillance Technology) and applied for the evaluations of In-Vessel and Ex-Vessel neutron dosimetry. The reaction rates from measurement and calculation were compared and the results show good agreements each other.

Effect of Neutron irradiation in $Fe_{81}B_{13.5}_Si{3.5}C_2$Amorphous Ribbon (비정질 $Fe_{81}B_{13.5}_Si{3.5}C_2$ 리본의 중성자 조사에 따른 자기적 특성변화)

  • 김효철;홍권표;김철기;유성초
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.2
    • /
    • pp.49-52
    • /
    • 2000
  • The changes of magnetic properties in neutron irradiated F $e_{81}$ $B_{13.5}$S $i_{3.5}$ $C_2$ amorphous ribbon were studied by X-ray diffraction, hysteresis loop, temperature dependence of magnetization and complex permeability. The fluences of thermal ( $n_{th}$) and fast ( $n_{f}$) neutron were 6.95$\times$10$^{18}$ $n_{th}$ c $m^{-2}$ and 4.56$\times$10$^{16}$ $n_{f}$c $m^{-2}$ , respectively. The changes of XRD Profiles were not observable at the neutron irradiated sample. The complex permeability spectra showed that the permeability from domain wall motion decreased due to the increase of pinning force against domain motion by the neutron irradiation, and the relaxation frequency of rotational magnetization moved to higher frequency region. The measurement of hysteresis loop showed the increase of magnetic softness, related to rotational magnetization, but saturation magnetization was decreased in neutron irradiation sample. The Curie temperature was decreased in the neutron irradiated sample.e.e.e.

  • PDF

A Study on Point Defect Induced with Neutron Irradiation (중성자 조사에 의해 생성된 점결함 연구)

  • 김진현;이운섭;류근걸;김봉구;이병철;박상준
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.3
    • /
    • pp.165-169
    • /
    • 2002
  • Silicon wafer is very important accuracy make use semiconductor device substrate. In this research, for the uniformity dopant density distribution obtained to Neutron Transmutation Doping on make use Si in P Doping study work. In this research. we irradiated neutron on FZ silicon wafers which had high resistivity (1000~2000 ${\Omega}$cm), HANARO reactor was utilized resistivity changes due to observed, the generation of neutron irradiation on point defect analyzed, point defect on resistivity changes inquire into the effect. Before neutron irradiation theoretical due to calculated 5 ${\Omega}$-cm, 20.1 ${\Omega}$-cm for HTS hole and 5 ${\Omega}$-cm, 26.5 ${\Omega}$-cm, 32.5 ${\Omega}$-cm for IP3 hole. After neutron irradiation through SRP measurement the designed resistivities were approached, which were 2.1 H-cm for HTS-1, 7.21 ${\Omega}$-cm for HTS-2, 1.79 ${\Omega}$-cm for IP-1, 6.83 ${\Omega}$-cm for IP-2, 9.23 ${\Omega}$-cm for IP-3, respectively. Also after neutron irradiation resistivity changes due to thermal neutron dependent irradiation hole types free.

  • PDF

Study of the Nondestructive Test Method for the Embrittlement Evaluation of Nuclear Reactor Vessel Material by $M{\ddot{o}}ssbauer$ Spectroscopy ($M{\ddot{o}}ssbauer$ 분광법에 의한 원자로 용기재료의 비파괴적 중성자 조사평가에 대한 연구)

  • Jung, M.M.;Jang, K.S.;Yoo, K.B.;Kim, G.M.;Yoon, I.S;Hong, C.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.3
    • /
    • pp.183-190
    • /
    • 2000
  • The purpose of this study is to evaluate the magnetic property change of the nuclear reactor vessel steel irradiated by fast neutrons using $M{\ddot{o}}ssbauer$ spectroscopy, and the effects of the defects produced by neutron irradiation on the changes using X-ray diffraction. The specimens, fabricated with the dimension of $23mm{\times}18mm{\times}70{\mu}m$, were irradiated by neutron fluence from $10^{12}n/cm^2\;to\;10^{18}n/cm^2$ at 343K. Throughout the experiments, it is understood that (1) the X-ray diffraction measurement shows that the change of crystal nature is started at the irradiation of $10^{16}n/cm^2$ and a crystal structure has been severely damaged at the irradiation over $10^{17}n/cm^2$, (2) the analysis of the $M{\ddot{o}}ssbauer$ spectra has shown that magnetic transition phenomena occur at the irradiation over $10^{17}n/cm^2$ and (3) both methods can be utilized as nondestructive test methods for the embrittlement evaluation of materials irradiated by fast neutrons.

  • PDF