• Title/Summary/Keyword: 중계 장치

Search Result 127, Processing Time 0.033 seconds

A Study of Automatic Fire Detection Installation based CAN Comunnication (CAN 통신기반 자동화재탐지설비에 관한 연구)

  • Kim, Young-Dong;Oh, Guem-Kon;Kang, Won-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.50-59
    • /
    • 2006
  • In this paper, We are going to propose the fire protection system using CAN(Controller Area Network). The larger, higher and deeper buildings an, the more dangerous people are when fire happens. We should be aware of the problems of prior fire protection system. Therefore, we construct the embedded system based on CAN communication that is capable of N to N communication, and build independent fire protection system. If the fire is occurred on the building, the problem is that how fast we can detect the fire and put it on by using available system, this is major factor that reduces damage of our wealth. Therefore in this studies, We would like to design more stable system than current system. This system is based on CAN communication which is available N to N communication constructs and designed to compensate for each fault, so that our aim is to reduce the wires of system, cost of installation and to suppose future type fire protection system.

A Study on Environment Management System in Tunnel using Wireless Sensor Networks (무선 센서 네트워크를 이용한 터널 내 환경 관리 시스템에 관한 연구)

  • Joo, Yang-Ick;Kim, Jae-Wan
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.10
    • /
    • pp.1196-1203
    • /
    • 2013
  • In general, the cost of transceiver for wireless network configuration is more expensive than that for wired network. However, in case of environmental management system in a tunnel, the cost can be minimized by adopting low rate tranceiver because the amount of the exchanged data for tunnel monitoring is very small. When the obtained data from sensor node is sent directly to the corresponding command node, there is no need to consider routing problem of the data transfer. However in this case, sensor nodes are required to be implemented with high power transmitter and experience high energy consumption. To tackle this problem, relay nodes can be used to transfer the data of tunnel monitoring, and suitable routing protocols for selecting optimum path are needed. Therefore, in this paper, we propose a routing algorithm and a self-configuration protocol for environment management system in tunnel.

The Design and Implementation of AMI System Using Binary CDMA (Binary CDMA 기반의 AMI 시스템 설계 및 구현)

  • Joe, In-Whee;Jeong, Jong-Yuel
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8C
    • /
    • pp.663-669
    • /
    • 2012
  • To solve the energy problem and finding new growth engines, interest for the smart grid is increasing and related technologies are making great efforts to secure in the world. AMI (Advanced Metering Infrastructure) Among them is the first to be constructed and getting attention as a key component of smart grid. A fusion of various technologies in technology development and demonstration is underway on Jeju Island Smart Grid Demonstration Complex in Korea, and focusing on broadband power line communication technology infrastructure is actively underway in Korea Electric Power Corporation. AMI system using power line communication technology without building a separate communication lines are available for power supply lines, but communication is impossible in occurs because admission to the power company or the ideal infrastructure for communication is not considered. In this paper, we analyze the requirements to build AMI system using Binary CDMA and powerline communications technology, and design the basic communication protocol based on Binary CDMA, implement network management and relay feature. By doing so, ways to apply Ad-hoc Binary CDMA indigenous technology to the AMI system were derived, and could build a system to make use of Wired (PLC) and wireless (Binary CDMA) simultaneously.

Display System Design for Signifying the Received Signals of the Mobile Phone (휴대폰 착신 알림을 위한 모바일 디스플레이 시스템 설계)

  • Park, Jong-An;Chun, Jong-Hun;Kang, Sung-Kwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.289-294
    • /
    • 2011
  • In this paper, we developed a phone call display system or "alimi" for displaying the received phone data at limited space that can not carry a mobile phone and and its validity was confirmed. It consists of a data communication application transmitting the phone data via bluetooth, a RF data repeater to extend the range of data communication, and a display system part for displaying the received phone data to the phone user. It has economy in terms of system installation because the implementation of the proposed system is simple and low cost installation is possible. As ordinary mobile phones users using the system can easily utilize it by downloading the application on the app. store, it has economy and convenience checking whether a call is received.

An artificial noise generation method for MODEM performance test in satellite communication system (위성통신 시스템에서 수신기 모뎀 성능을 시험하기 위한 인위 잡음 발생 방법)

  • Cho, Tae-Chong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.59-64
    • /
    • 2020
  • Occasionally, MODEM test in satellite communication systems are needed. But Rx terminals in satellite communications are designed to obtain high SNR generally, therefore artificial bad conditions and environments are demanded for the test. One of the typical method is satellite output power reduction. Using noise generator can be another method. However, these costs a lot of money, time, and procedures in reality. In order to overcome these problems, this paper proposes an artificial noise generation method for MODEM test in satellite communication systems. First of all, SNR of a general heterodyne Rx terminal is calculated. Based on the calculation, a new model which is including variable attenuator is proposed to increase noise level. Simulation results illustrate the variable attenuator can control SNR, and these show that MODEM test in satellite communication systems be possible.

Turbo-coded STC schemes for an integrated satellite-terrestrial system for cooperative diversity (협동 다이버시티 이득을 위한 위성-지상간 통합망에서의 터보 부호화된 시공간 부호)

  • Park, Un-Hee;Kim, Soo-Young;Kim, Hee-Wook;Ahn, Do-Seob
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1A
    • /
    • pp.62-70
    • /
    • 2010
  • In this paper, we evaluate the performance of various diversity techniques which can contribute to provide efficient multimedia broadcasting services via hybrid/integrated satellite and terrestrial network. Space-time coding (STC) can achieve the diversity gain in a multi-path environment without additional bandwidth requirement. Recent study results reported that satellite systems can achieve high diversity gains by appropriate utilization of STC and/or forward error correction schemes. Based on these previous study results, we present various cooperative diversity techniques by combining STC and rate compatible turbo codes in order to realize the transmit diversity for the mobile satellite system. The satellite and several terrestrial repeaters operate in unison to send the encoded signals, so that receiver may realize diversity gain. The results demonstrated in this paper can be utilized in future system implementation.

Development of Vending Machine for Electricity Based on Z-Wave Mesh Network (Z-Wave 메쉬 네트워크 기반의 전기 자판기 개발)

  • Kang, Ki-beom;Ahn, Hyun-kwon;Kim, Han-soo;Lee, Seung-hyun;Jwa, Jeong-woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.10
    • /
    • pp.1256-1262
    • /
    • 2016
  • As the population of camping is increased in campsites and auto camp sites, the electrical equipment can safely supply electricity to users in a variety of electricity bill policy is required in the campsite. In this paper, we develop the vending machine for electricity that can control the outdoor electrical outlet from the management server using the Z-Wave WPAN and android mobile application. The developed vending machine for electricity consists of the management server, the controller, the outdoor outlet box, and the mobile application. The management server provides reservation and electricity bill payment to users. The management server controls the electrical outlet box through the controller to safely supply electricity to users. The controller that is a relay device between the management server and the switch controls switches based on Z-Wave mesh network. Outdoor electrical outlet box has 2 meter switches. We receive the relevant authorization to provide commercial electricity services using the outdoor electrical outlet box in the campsite.

A Study on the Wireless Communication Method for Emergency Broadcasting System in Metro Environments (도시철도용 비상방송시스템을 위한 무선통신방식 연구)

  • Jang, Soo-Hyun;Shin, Dae-Kyo;Yoon, Sang-Hun;Jung, Han-Gyun;Jin, Seong-Keun;Lim, Ki-Taeg
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.6
    • /
    • pp.202-210
    • /
    • 2018
  • Recently, the subway running in metro environments has a problem in securing the safety of passengers due to the failure of announcement in emergency situations such as breakdown, train accidents and power outage in the underground tunnels. Thus, there is a need to develop an emergency broadcasting system that can provide the announcement to all passenger cars in any emergency situations on the railway route. In this paper, the applicability of various wireless communication technologies for the emergency broadcasting system through the measurement campaign was examined in Seoul metropolitan subway. A WAVE(Wireless Access in Vehicular Environments) is communication technology that can use 5.9GHz dedicated frequency band without charge and it is possible to directly communicate between terminals over 200m without the help of additional relay. Especially, it confirms robust communication performance in the various metro environments, and therefore, it is considered to be suitable as a communication method of a radio-connected emergency broadcasting system for urban subway.

Characteristics on the Vertical Load Capacity Degradation for Impact driven Open-ended Piles During Simulated Earthquake /sinusoidal Shaking, (타격관입 개단말뚝의 동적진동에 의한 압축지지력 저감특성)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.51-64
    • /
    • 1996
  • After the model open-ended pile attached with strain gages was driven into a pressure chamber, in which the saturated microfine sand was contained, the static compression loading test was performed for that pile. Based on the test results, ultimate pile capacity was determined. Then, either simulated earthquake shaking or sinusoidal shaking was applied to the pile with the sustained certain level OP ultimate pile load. Then, pile capacity degradations characteristics during shaking were studied. Pile capacity degradation during two different shakings were greatly different. During the simulated earthquake shaking, capacity degradation depended upon the magnitude of applied load. When the load applied to the pile top was less than 70% of ultimate pile capacidy, pile capacity degradation rate was less than 8%, and pile with the sustained ultimate pile load had the degradation rate of 90%. Also, most of pile capacity degradation was reduced in outer skin friction and degradation rate was about 80% of ultimate pile capacity reduction. During sinusoidal shaking, pile capacity degradation did not depend on the magnitude of applied load. It depended on the amplitude and the frequency , the larger the amplitude and the fewer the frequency was, the higher the degradation rate was. Reduction pattern of unit soil plugging (once depended on the mode of shaking. Unit soil plugging force by the simulated earthquake shaking was reduced in the bottom 3.0 D, of the toe irrespective of the applied load, while reduction of unit soil plugging force by sinusoidal shaking was occurred in the bottom 1.0-3.0D, of the toe. Also, the soil plugging force was reduced more than that during simulated earthquake shaking and degradation rate of the pile capacity depended on the magnitude of the applied load.

  • PDF

Heat Exchange Element Made of Plastic for Cooling of Telecommunication Cabinet (통신 함체 냉각용 플라스틱 재질의 열교환 소자)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.702-708
    • /
    • 2017
  • The heat generation rate in a telecommunications cabinet keeps increasing due to the increased usage of mobile devices. Insufficient removal of the heat increases the cabinet temperature, which results in the malfunction of the electronic devices. In this study, tests were conducted on aluminum and plastic heat exchangers for cooling a telecommunications cabinet, and the results were compared with theoretical predictions. The aluminum heat exchanger comprised counter flow parallel channels with 4.5-mm pitch, and the plastic heat exchangers comprised cross or cross-counter flow triangular channels with 2.0-mm pitch. The volume of the cross flow heat exchanger was the same as that of the aluminum heat exchanger, and the volume of the cross-counter heat exchanger was 33% larger than that of the aluminum heat exchanger. The results show that the heat transfer rate is the highest for the cross-counter heat exchanger and lowest for the aluminum one. The temperature efficiency of the cross-counter heat exchanger was 56% higher than that of the aluminum one and 20% higher than that of the cross flow heat exchanger. The pressure drop of the cross-counter heat exchanger was approximately the same as that of the aluminum one. The heat exchange efficiency was the highest for the cross-counter heat exchanger and lowest for the cross flow heat exchanger. The theoretical analysis somewhat overestimated or underestimated the data.