• Title/Summary/Keyword: 준임계

Search Result 108, Processing Time 0.024 seconds

Analysis of Critical Time Headway and Capacity for Freeway Merging Area (고속도로 합류부 임계차두간격 및 용량 산정에 관한 연구)

  • 최재성;이승준
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.6
    • /
    • pp.195-205
    • /
    • 2001
  • The objective of the paper is to analyze the traffic characteristics for freeway merging area. Freeway merging area is different from basic section due to ramp vehicles. Therefore, to understand the traffic characteristics of (leeway merging area, this study focused on two factors including critical time headway required in merging maneuver and maximum possible merging volume. In this paper, new model that adopts critical time headway instead of critical time gap in calculating the maximum possible merging volume based on probability function was developed In previous studies, for calculating the maximum possible merging volume, it was considered that merging vehicles could merge freely if a given time gap was greater than the critical time gap. Also, the critical time gap was used as the same value in all traffic flow conditions. But, a time gap required in merging maneuver could be changed, even to the same driver, because difference of relative speed varies in different traffic flow conditions. So, in some cases, the critical time gap could be insufficient value in merging maneuver. Therefore, in this study. a calculating procedure for critical time headway in all traffic flow conditions was presented. Also, the maximum possible merging volume and capacity for freeway merging area were calculated by using the previously found critical time headway.

  • PDF

Papers : Drag Reduction of a Circular Cylinder with a Front Small Control Rod (논문 : 전방에 제어봉을 갖는 원주의 항력감소에 관한 연구)

  • Lee, Sang-Ik;Lee, Sang-Jun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.3
    • /
    • pp.87-95
    • /
    • 2002
  • 원주의 항력 감소와 원주 주위 유동의 제어에 대하여 실험적으로 연구하였다. 원주 주위 유동을 제어하기 위하여 작은 제어봉을 원주 전방에 설치하였다. 실험시 원주 직경(D=30mm)에 기초한 레이놀즈수는 $Re=2 {/times} 10^4$이었다. 제어봉의 직경(d)은 4mm, 5mm, 6mm, 7mm로 변화시켰으며, 원주와 제어봉 사이의 거리(L)를 조절하면서 원주의 표면압력분포와 후류속도를 측정하였다. 제어봉으로부터의 와 유출이 사라지는 임계거리 (critical distance) $ L_C$$ L_C$ /D=1.5+0.83d이었는데, $ L_C$를 전후로 유동특성과 항력값이 크게 바뀌었다. 특히 원주와 제어봉 사이의 거리가 임계거리보다 짧은 경우에는 항력이 감소하다가 $ L_C$보다 크게 되면 증가하는 경향을 보였다. 제어봉의 직경이 d/D=0.233인 경우, L/D=2.013의 조건에서 원주는 약 29%의 항력 감소를 보였고, 전체 항력은 L/D=1.833조건에서 약 25% 항력이 감소하였다.

Study on the Stability of Cantilevered Pipe Conveying Fluid Subjected to Distributed Follower Force (분포종동력을 받는 외팔 송수관의 안정성에 관한 연구)

  • Kong, Chang-Duk;Park, Yo-Chang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.27-34
    • /
    • 2005
  • The paper discussed on the stability of cantilevered pipe conveying fluid subjected to distributed follower force. Governing equations of motion are derived by extended Hamilton's principle, and the numerical scheme using finite element method is applied to obtain the discretized equations. The critical flow velocity as a function of the distributed follower force for the various mass ratio is determined. The flutter configurations of the pipes at the critical flow velocities are drawn graphically at every twelfth period to define the order of quasi-mode of flutter configuration The critical mass ratios, at which the transference of the eigenvalue branches related to flutter take place, are definitely determined. Also, the effect of damping on the stability of the system is considered.

Fast Detection of Abnormal Data in IIoT with Segmented Linear Regression (분할 선형 회귀 분선을 통한 IIoT의 빠른 비정상 데이터 탐지)

  • Lee, Tae-Ho;Kim, Min-Woo;Lee, Byung-Jun;Kim, Kyung-Tae;Youn, Hee-Yong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.101-102
    • /
    • 2019
  • 산업용 IoT (IIoT)는 최근들어 제조 시스템의 중요한 구성 요소로 간주된다. IIoT를 통해 시설에서 감지된 데이터를 수집하여 작동 조건을 적절하게 분석하고 처리한다. 여기서 비정상적인 데이터는 전체 시스템의 안전성 및 생산성을 위해 신속하게 탐지되어야한다. 기존 임계 값 기반 방법은 임계 값 미만의 유휴 오류 또는 비정상적인 동작을 감지 할 수 없으므로 IIoT에 적합하지 않다. 본 논문에서는 예측 구간과 우선 순위기반 스케줄링을 이용한 분할 선형 회귀 분석을 기반으로 비정상적인 데이터를 검출하는 새로운 방법을 제안한다. 시뮬레이션 결과 제안한 기법은 비정상적인 데이터 검출 속도에서 임계치, 일반 선형 회귀 또는 FCFS 정책을 사용하는 기존의 기법보다 우수함을 알 수 있었다.

  • PDF

A Study on the Laminar Flow Field and Heat Transfer Coefficient Distribution for Supercritical Water in a Tube (초임계상태의 물에 대한 관 내 층류유동장 및 열전달계수 분포특성에 관한 연구)

  • 이상호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.768-778
    • /
    • 2003
  • Numerical analysis has been carried out to investigate laminar convective heat transfer in a tube for supercritical water near the thermodynamic critical point. Fluid flow and heat transfer are strongly coupled due to large variations of thermodynamic and transport properties such as density, specific heat, viscosity, and thermal conductivity near the critical point. Heat transfer characteristics in the developing region of the tube show transition behavior between liquid-like and gas-like phases with a peak in heat transfer coefficient distribution near the pseudocritical point. The peak of the heat transfer coefficient depends on pressure and wall heat flux rather than inlet temperature and Reynolds number, Results of the modeling provide convective heat transfer characteristics including velocity vectors, temperature, and the properties as well as the heat transfer coefficient. The effect of proximity to the critical point is considered and a heat transfer correlation is suggested for the peak of Nusselt number in the tube.

A Study on the Transient Convective Heat Transfer for Supercritical Water in a Vertical Tube (수직관 내 초임계상태 물의 천이상태 대류열전달현상에 관한 연구)

  • Lee Sang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1095-1105
    • /
    • 2005
  • Numerical analysis has been carried out to investigate transient turbulent convective heat transfer in a vertical tube for supercritical water near the thermodynamic critical point. Heat transfer and fluid flow in the tube we strongly coupled due to the large variations of thermodynamic and transport properties such as density, specific heat, and turbulent viscosity. As pressure in the tube approaches to the critical pressure, the properties variation with time becomes larger. Heat transfer coefficient rapidly decreases along the tube near the pseudocritical temperature at the tube wall for $P_R<1.2$. Stanton number variation with time is largely reduced in the region of gas-like phase in comparison with Nusselt number. Turbulent viscosity ratio close to the wall increases near the pseudocritical temperature and it gradually decreases with time.

An analysis of the Reacture Inutuation of falling type Impact Test for toughened Rigid Plastics (인성의 강소성 플라스틱 재료에 대한 낙하충격 시험의 파괴개시에 관한 연구)

  • 김진우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.4
    • /
    • pp.385-393
    • /
    • 1984
  • 본 연구에서는 다트식 낙하충격 시험에 있어서 인성의 강소성 플라스틱 재료 의 준정적 선형의 점탄성 모델이 구성되어 해석되었다. 완화계수함수, E(t)=E$_{f}$ +(E$_{o}$ -E$_{f}$ )e$^{-t/tR}$ 형태의 점탄성 재료의 수정된 Maxwell요소모델을 근거 로 충격속도, 파괴에너지, 임계응력등의 중요변수들의 상대적 종속성이 근사계산으로 평가되었다.

An Equation of State to Meet the Boundary Conditions between Critical Point and Inversion Points (임계온도와 반전점들 사이의 경계조건에서 구한 기체의 상태방정식)

  • Seung-Hee Kim;Wonsoo Kim;Tong-Seek Chair
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.487-492
    • /
    • 1991
  • $[P+a(b/v)^n]$ = RT / (V - b) Above equation of state had been derived from Roulette theory. Three parameters-a, b, n are estimated from the critical point and the inversion temperature. When it is applied to 52 materials and to the regions of high density such as dense gas and supercritical gas, the results are good.

  • PDF

Dual Mode Packet Transmission Scheme using a Dynamic Switching Threshold in the IMT-2000 (IMT-2000에서 동적 스위칭 임계점을 이용하는 이중 모드 패킷 전송방식)

  • 김장욱;반태원;오창헌;조성준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.907-915
    • /
    • 2003
  • A very efficient packet transmission scheme is needed in the radio environment where radio resource is insufficient as compared with the environment of the wired communication. In general, dual mode packet transmission scheme is used broadly. Packets are transmitted through the dedicated or common chamois according to a switching criterion. The general criteria are the length and generation frequency of packet, that is, large and frequent packets are transmitted using a dedicated channel and small and infrequent packets are transmitted using a common channel. The performance of dual mode packet transmission scheme is closely related to the switching criteria. However, it is very difficult to find the optimal switching point because that is not fixed but variable according to the environment such as traffic load, length of generated packets, and the number of channels. In this paper, a new scheme for the dual mode packet transmission scheme using a dynamic switching threshold is proposed where the switching threshold is not fixed but variable according to the network environment. The performance of the proposed method is analyzed using a simulation. From the simulation results, it is shown that the performance of the proposed scheme is not very influenced by the network environment unlike the conventional dual mode packet transmission scheme.