Recently, floor impact sound has become a serious social problem in Korea. There is an increasing need to improve floor impact sound performance using floor covering installed on the floor of apartment houses. KS F ISO 717-2 and KS F 2863 require measurement under conditions in which the resilient material is not installed. But most apartment houses in Korea install resilient materials to reduce floor imapct sound. The performance evaluation method of floor covering should provide reduced performance for use by residents of apartment houses with resilient materials. Therefore, this paper proposes a reduction performance evaluation under the conditions in which a resilient material is installed to verify the performance of floor covering.
As greater numbers of fill dams and reservoirs become old, the risks of damage or embankment collapse increases. However, few studies have considered the deterioration and hazard classification of the internal core layers of fill dams. This study reports the results of geotechnical investigations of 13 earth-cored fill dams in Korea, based on no-water borehole drilling, Standard Penetration Test, and 2D and 3D electrical resistivity surveys along with in situ and laboratory testing. High-capacity no-water boring minimized core layer disturbance while providing continuous core sample recovery. The results allow the classification of potential hazards related to the existing core layers based on both visual inspection of the recovered samples and the results of engineering surveys and tests. Four types of potential hazard are classified: locally fluidized core with a high water content, rapid water inflow to a borehole, cores with granular materials, and relatively low stiffness of core. Among these, the locally fluidized core is the most critical hazard that requires remedial action because it is related to the potential internal flow path and internal erosion. The other three hazard types are of medium importance and require careful monitoring and regular inspection. Of note, there was no correlation between age and core deterioration. The results are expected to aid the safe management and potential upgrading of aging cored fill dams.
Proceedings of the Korea Water Resources Association Conference
/
2023.05a
/
pp.6-6
/
2023
국토교통부는 R&D 사업인 '분산공유형 건설연구인프라구축사업(2004년~2009년, 6종)'과 '국토교통기술실험인프라 2단계 구축사업(2013년~2019년, 6종)'을 통해 첨단 연구시설·장비를 전국에 분산 구축하여 실험시설이 부족한 중소기업·대학 등이 공동활용할 수 있도록 총 12종의 건설분야 대형실험시설을 구축하였다. 국토교통 R&D 성과(기술·제품)의 품질 및 신뢰성 확보를 통해 개발기술의 상용화 촉진을 위해서는 이러한 국토교통 대형실험시설·장비를 활용한 표준화된 성능평가 시험기반(표준실험절차, 단체표준 등)을 구축하여 연구인프라의 공동활용을 촉진하고 기술개발 성공률 제고와 함께 건설분야 시험인증 산업을 육성할 필요가 있다. 국토교통 대형실험시설을 활용하여 건설분야 기술·제품에 대한 성능평가 기반의 실험절차를 표준화함으로써 성능평가 결과의 신뢰성 확보 및 기술시험서비스 역량 제고를 위한 '건설분야 기술·제품의 검증을 위한 성능기반 표준실험절차 개발(연구기간: '17.06~'22.06, 연구비: 총99억원, 주관기관: 국토교통연구인프라운영원)' 과제가 성공적으로 수행 완료되었다. 이 과제를 통해 총 53개의 표준실험절차서와 20개의 단체표준이 제정되었다. 이어서, 2단계 대형실험시설 준공완료에 따라 '건설분야 성능기반 표준시험절차 개발 사업(연구기간: '21.04~'25.12, 연구비: 총143.8억원)이 수행되고 있다. 현재, 국토교통연구인프라운영원은 이 사업 내 국제융합수리(주관기관: 한국농어촌공사 농어촌연구원), 극한성능(주관기관: 서울대학교) 및 기상환경재현(주관기관: 한국건설기술연구원) 표준실험절차 개발 과제에 공동기관으로 참여하여 단체표준 개발업무를 담당하고 있다. 본 논문에서는 단체표준 소개 및 현황에 대해 설명하고, 1단계 표준실험절차 개발과제를 통해 정립되었고 현재 2단계 표준실험절차 개발과제에도 적용되고 있는 시험관련 단체표준(안) 개발 프로세스에 대해 기술하고자 한다. 개발된 단체표준은 건설관련 실험·시험시설을 보유한 기관(대학, 공공기관, 산업체 연구소 등)의 성능검증 시험, 신기술 및 신제품 인증 표준절차에 활용가능하며, 시방서와 설계기준에 KS표준과 같이 시험 및 검사방법에 있어 참조표준으로도 활용 가능하다.
In order to evaluate the stability of the geo-structure of railway bridge, the response dominant frequency was analyzed based on a series of impact vibration load test results. The specifications of the experiment piers were obtained by referring to the completion design data, and when data was missing, a field study was conducted. The impact vibrations test according to the scouring progress was carried out at one pier scheduled to be abandoned, and it was confirmed that the response dominant frequency can be utilized as an evaluation index for scour. In addition, the response dominant frequency was measured through an impact load test at 46 piers in 5 bridges in operation, and the scour safety of the bridge was evaluated by comparing it with the japanese proposal formula.
Proceedings of the Korean Radioactive Waste Society Conference
/
2003.11a
/
pp.168-171
/
2003
The IMEF(Irradiated Materials Examination Facility), located in KAERI site, is a hot cell facility to test and evaluate the irradiation defects or embrittlement through post-irradiation examination(PIEs) of irradiated nuclear fuels and structural materials which are come from HANARO research reactor and commercial nuclear power plants. Therefore, to carry out its own function, the high level solid radioactive wastes, produced through PIEs, are periodically carried out and managed from hot cell to monolith. So far, approximately 30 drums which contains 50 liters are transported to monolith, and it is shown that the quantity is slowly increasing, In this paper, the procedures and work contents of the high level solid radwaste carrying out and management for IMEF are described in detail.
1995년 한국 최초로 VLBI관측이 이루어졌다. 일본 측의 26m 안테나(일본 국토연구원 소재)와 한국 측의 3.6m 안테나(국토지리정보원 소재)로 수행되었으며, 이 때 결정된 관측점의 좌표가 세계 공통으로 사용되는 "세계측지계(ITRF)"에 의거한 새로운 국가기준좌표계의 경위도 원점이다. 그 후 측지VLBI관측국의 설치를 위해, "측지VLBI구축 타당성조사 및 기본계획 수립을 위한 연구(2003년)"와 "측지VLBI구축 실시설계(2006년)"를 수행하였다. 그 결과 국가 차원에서 측지VLBI관측소(22m 안테나)를 건설하기 위해 2008년에 관측소 후보지를 세종시로 확정해서 공사에 들어갔다. 2012년에 준공되었으며, 명칭을 "우주측지관측센터"로 하였다. 그 후 1년 동안의 시험관측의 성공으로 아시아에서 3번째로 정식으로 IVS(International VLBI Service)에 가입하였다. 현재 독일, 일본, 미국 등의 측지VLBI관측국들과 정기적으로 관측을 수행하게 되었으며, 실적을 올리고 있다. IVS사업 뿐 만 아니라, 한국천문연구원의 KVN(천문 VLBI)연구팀과도 공동연구를 수행해서 우리나라의 천문 VLBI 및 측지VLBI관측사업의 활성화에 기여하고 있다. 장차 동남아 각국에 마이크로SAR위성의 관측데이터를 수신하기 위한 지상국(3m급 소형안테나)이 설치되면, 이를 활용해서 측지VLBI관측을 수행할 계획을 수립하고 있다. 이것은 위성용 수신기를 VLBI용 수신기로 교체하면 된다. 한국과 일본이 VLBI관측을 수행했던 것처럼 세종시에 설치된 우주측지관측소가 허브역할을 하면 된다. 즉 동남아 지역에 우주 VLBI관측망을 구축하게 된다.
Kim, Hwa-Jong;Kim, Hyun-Ju;Kim, Do-Young;Park, Jeong-Ki;Jo, Jang-An;Choi, Man-Ok
Proceedings of the KIEE Conference
/
2009.07a
/
pp.1393_1395
/
2009
지중송전라인에서 전압등급의 상승은 선로손실을 줄이면서 밀집된 전력수요에 대응하거나 특별히 고전압 수요를 맞추기 위한 것으로 이것은 XLPE Cable의 제조기술이 향상되면서 지속적으로 진행되어온 초고압송전계통의 일반적 추세이다. 이러한 경향으로 국내에서는 지중송전선로로서 최고전압인 345kV가 시공되어 운전중에 있으며 해외에서는 220kV~275kV급을 넘어서 400kV급 초고압케이블라인의 수요가 증가하고 있는데, 이러한 지중송전라인의 초고압화는 높은 신뢰성이 함께 요구되며 특히 접속재 분야에서 매우 높은 신뢰성이 요구된다. 당사는 UAE 400kV AL TAWEELAH Project에 400kV XLPE 1Cx630SQ 광복합 초고압송전라인을 준공하였는데 본고에서는 여기에 적용된 400kV XLPE 1Cx630SQ 광복합 케이블 부속재의 신뢰성을 높이기 위한 설계방법, 시험 및 시공에 대하여 요약하였다.
The Journal of Korea Institute of Information, Electronics, and Communication Technology
/
v.11
no.2
/
pp.129-136
/
2018
The IEC 61850 communication standard is used worldwide, and within the country the new substation is built as a digital substation based on IEC 61850 from 2013, after field tests and R&D from 2007. Research on the development of digital substation operating system has been conducted mainly in large domestic companies, so the IED power application equipment for LCP are developed. However, there is still a lack of research in the field of systems that can accommodate all the field devices used for legacy substation and new digital substation. In this paper, we developed the 48VDC input modules and the 125VDC output modules which can construct proposed field information processing modules to IEC 61850 based type, and verified the field applicability from the state monitoring and control operation tests by using IEC 61850 client authentication program and Wireshark.
We carried out this study to provide basic data necessary to establish a management plan for concrete erosion control dams in the future by analyzing results of detailed inspections of aged dams conducted in accordance with 「Guidelines for the Maintenance of the Erosion Control Facility」. We analyzed the results of a detailed inspection of 54 concrete erosion control dams which had been built over 20 years previously, located in private forests of Gyeongsangbuk-do using statistical methods. Having conducted exterior defect investigations, we found 18 dams (33.4%) in need of repair or follow-up measures and 15 dams in which the overall grade was changed due to investigator's corrections; we therefore considered that standardization of related standards and indicators would be necessary. After conducting concrete compression strength tests, we found 19 dams (35.2%) to be below the standard value of 21 MPa, and in particular, we included, in grade A, eight dams which we judged to be in good condition as a result of the exterior defect inspection. There was little clear correlation between the total score and the compressive strength of concrete, but there was a statistically significant difference in the compressive strength by overall grade. After analyzing the changes in the characteristics of the erosion control dams according to the elapsed years after construction, we detected no particular trend in the changes of total score and compressive strength over time. However, the cumulative ratio of the dams that required repair and follow-up measures and the dams below the compression strength standard had a strong positive linear relationship over time, suggesting that it would be possible to identify the aging characteristics of concrete erosion control dams.
The Journal of the Convergence on Culture Technology
/
v.5
no.3
/
pp.43-54
/
2019
In this study, results of completion inspection are investigated according to the performance of the firefighting construction supervision personnel and according to the necessity of clean air supply in a performance test of the firefighting construction supervision personnel. The results of the completion inspection are measured and the causes of defects in the fire protection facilities after issuance of a completion inspection certificate are analyzed. The findings of this investigation can be used to minimize the risk of apartment fires and improve the performance of firefighting construction supervision personnel. The results of this study are summarized as follows. First, the results of the completion inspection conducted by the firefighting construction supervision personnel varies according to particular occupation. The performance of fire facility supervisors from design companies and fire construction companies were significantly higher than the fire officers. Therefore, it is necessary to employ supervisors who have experience in supervising the construction of apartments, in order to improve the performance of fire construction supervision officers. Second, the analysis of the completion inspection results according to the necessity of a clean air supply for performance tests of firefighting construction supervision personnel showed that the necessity of a clean air supply was significantly higher for fire facility supervisors from design companies and fire construction companies than for the fire officers. In order to improve, the completion inspection should be carried out up until the completion date of the building. In addition, a system needs to be established to ensure that clients are not able to demand that a completion inspection certificate be issued on the construction completion date. Finally, it is found that defects of completion inspection after issuance of a completion inspection certificate affects the result of the completion inspection. The results of the completion inspections conducted by the fire facility supervisors from design companies and fire construction companies were affected significantly less by defects than that of the general contractors. Research shows that faults have occured in firefighting facilities after the issuance of a completion inspection certificate due to the client and the construction company demanding the issuance of the completion inspection certificate.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.