• Title/Summary/Keyword: 주택에너지

Search Result 597, Processing Time 0.025 seconds

Assessment of Carbon Emission for Quantification of Environmental Load on Structural Glued Laminated Timber in Korea (국산 구조용 집성재의 환경부하 정량화를 위한 온실가스 배출량 분석)

  • Chang, Yoon-Seong;Kim, Sejong;Son, Whi-Lim;Lee, Sang-Joon;Shim, Kug-Bo;Yeo, Hwanmyeong;Kim, Kwang-Mo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.449-456
    • /
    • 2016
  • This study was aimed to quantify the amount of carbon dioxide emissions and to suggest suitable plans which consider the carbon emission reduction in the manufacturing process of the domestic structural glued laminated timber. Field investigation on two glued laminated timber manufacturers was conducted to find out material flow input values such as raw materials, transportation, manufacturing process, and energy consumption during manufacturing process. Based on the collected data and the relevant literatures about life cycle inventory (LCI), the amount of carbon dioxide emission per unit volume was quantified. Results show that the carbon dioxide emissions for sawing, drying and laminating process are 31.0, 109.0, 94.2 kg $CO_2eq./m^3$, respectively. These results show 13% lesser amount of total carbon dioxide emissions compared with the imported glued laminated timber in Korea. Furthermore, it was decreased about 37% when the fossil fuel would be replaced with biomass fuel in drying process. Findings from this study is effectively used as the basic data on the life cycle assessment of wooden building.

The Method of Quantitative Analysis Based on Big Data Analysis for Explanatory Variables Containing Uncertainty of Energy Consumption in Residential Buildings - Focused on Apartment in Seoul Korea (주거용 건물의 에너지 실사용량의 불확실성을 내포한 설명변수 인자에 대한 빅데이터 분석 기반의 정량화 방법 - 서울지역의 공동주택을 중심으로)

  • Choi, Jun-Woo;Ahn, Seung-Ho;Park, Byung-Hee;Ko, Jung-Lim;Shin, Jee-Woong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: The energy consumption of apartment units is affected by the lifestyle of the residents rather than system technology. In this study the numerical analysis of assumed energy consumption correlation factors with arbitrary value due to uncertainty. It is intended to be used as a simulation correction value which can be utilized as a predicted value of actual energy usage. The correction value of the simulation is set in the developed form of the existing process that derives the actual usage amount. The simulation results used in the existing evaluation system are used to maintain the useful value as the current system evaluation scale and predict the actual capacity. Method: The method of the study is to statistically analyze the data frames of all complexes capable of collecting the annual energy usage and to reconstruct the population by adding the variables that are expected to be correlated. Repeat the data frame configuration with variables that are assumed to be highly correlated with energy use levels. Determine whether there is correlation or not. The intensity of the external characteristics of the building equipment related to the energy consumption is presented as the quantitative value. Result: The correlation between electricity consumption and trading price since 2010 is analyzed as (Correlation coefficient 0.82). These results are higher than (Correlation coefficient 0.79), which is the correlation between residential area and trading price. This paper signifies the starting point of the methodology that broadens the field of view of verification of simulation feasibility limited to the prediction technique focused on the simulation tool and the element technology scope.The diversified phenomenon reproduction method develops the existing energy simulation method.It can be completed with a simulation methodology that can infer actual energy consumption.

mSFP: Multicasting-based Inter-Domain Mobility Management Scheme in Sensor-based Fast Proxy Mobile IPv6 Networks (센서기반 FPMIPv6 네트워크에서 멀티캐스팅 기반의 도메인간 이동성관리 기법)

  • Jang, Hana;Jeong, Jongpil
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.1
    • /
    • pp.15-26
    • /
    • 2013
  • IP-based Wireless Sensor Networks (IP-WSNs) are gaining importance for their broad range of applications in health-care, home automation, environmental monitoring, industrial control, vehicle telematics and agricultural monitoring. In all these applications, mobility in the sensor network with special attention to energy efficiency is a major issue to be addressed. Because of the energy inefficiency of networks-based mobility management protocols can be supported in IP-WSN. In this paper we propose a network based mobility supported IP-WSN protocol called Multicasting-based inter-Domain Mobility Management Scheme in Sensor-based Fast Proxy Mobile IPv6 Networks (mSFP). Based on [8,20], We present its network architecture and evaluate its performance by considering the signaling and mobility cost. Our analysis shows that the proposed scheme reduces the signaling cost, total cost, and mobility cost. With respect to the number of IP-WSN nodes, the proposed scheme reduces the signaling cost by 7% and the total cost by 3%. With respect to the number of hops, the proposed scheme reduces the signaling cost by 6.9%, the total cost by 2.5%, and the mobility cost by 1.5%. With respect to the number of IP-WSN nodes, the proposed scheme reduces the mobility cost by 1.6%.

An identification of optimized energy usage factors and monitoring System development for safety identification for elderly living (독거노인 안전확인을 위한 최적 에너지원 규명 및 모니터링 시스템 구현)

  • Kim, Hosik;Cha, Youna;Chin, Sangyoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.4
    • /
    • pp.39-48
    • /
    • 2014
  • The speed of aging society is increasingly getting faster in Korea. Currently, there are over one million elderly living alone, which represents more than 19% of the total elderly in Korea. Although various policies and research have been implemented for caring the elderly living alone, there have been obvious limitations in realization of the caring system due to inconvenience, privacy violation, difficult operation and maintenance. Therefore, the objective of this study is to develop a method and a prototype system to monitor safety of elderly living alone by using energy usage information of automatic meter reading device. The proposed system is expected to improve or resolve the existing limitations and to provide 24 hour monitoring and early detection of death for the elderly living alone without adding staffs for operation and maintenance in a more effective and economic way.

An Experimental Study to Establish a System for Vertifying the Insulation Performance of Buildings (건축물의 단열성능 검증 시스템 구축을 위한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.203-211
    • /
    • 2021
  • Recently, the insulaton design standards for reducing the energy use of buildings have been strengthened. Althoug insulation work is the most cost-effective method for reducing the primary energy consumption per unit area of a building, there are no evaluation criteria for insulation performance at the time of construction and completion inspection. The purpose of this study is to provide objective data by establishing a standard for an analysis method and a method for easily experimenting with the exterior wall thermal transmittance of an apartment house using a thermal transmittance measuring device(TESTO 435). For the exterior wall of the test subject, the specific heat per unit area exceeded 20kJ/(m2·K), and the data at the end point suitable for ISO 9869-1 were analyzed by the average method. The measured values of the thermal transmittance for 3 consecutive days converged within +5% of the desing value, and the standard deviation of the thermal transmittance by day decreased in the order of 1-Day > 3-Day > 2-Day. The standard deviation of the thermal transmittance by time period decreased in the order of 00:00~24:00 < 19:00~07:00 < 00:00~07:00. The measured value of the thermal transmittance for the time perion of 00:00 to 07:00 per day almost coincided with an error of -3% to + 2% compare to the desing value.

Analysis of the 2nd Pilot Test of Time of Use (TOU) Pricing for Korean Households (주택용 계시별 요금제 2차 실증사업의 효과 분석)

  • Kim, Jihyo;Lee, Soomin;Jang, Heesun
    • Environmental and Resource Economics Review
    • /
    • v.31 no.2
    • /
    • pp.205-232
    • /
    • 2022
  • This study analyzes the effect of the 2nd pilot test of Tiime of Use (TOU) pricing for Korean households using a two-level electricity demand model. The test, implemented from May to September 2021, was conducted to compare the effects of two TOU pricing rates and the standard rates for households living in apartment and detached house in 7 provinces of Korea. Based on the data on electricity consumption during the test period and during the same period last year of the 1,292 participants and their socio-economic characteristics, this study analyzes (1) whether the relative demand across periods has changed in response to hourly price changes and (2) whether the price responsiveness of daily consumption has changed after the introduction of TOU pricing. The results show that both types of TOU pricing affect neither the relative demand across periods nor the price responsiveness of daily consumption. The reason behind the results could be related to the level of TOU pricing rates and the periodical classification, which were not sufficient to induce changes in the participants' electricity demand patterns.

Calculation of the Theoretical Total Amount Ratio of Di(2-ethyl-hexyl) Phthalate in Indoor Air and Floor Dust in a Test House (모의 실험주택 모니터링 결과를 활용한 실내공기 및 바닥먼지 중 Di(2-ethyl-hexyl) phthalate (DEHP)의 이론적 총량 비율 산출)

  • SaHo Chun;Khawon Lee;SeungJung Kim;SeungPyo Jung;DaYoung Kang;Ki-Tae Kim
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.6
    • /
    • pp.324-333
    • /
    • 2023
  • Background: Human exposure to phthalates in indoor environments occurs via dermal absorption, oral ingestion of indoor dust, and inhalation of indoor air. However, systematic studies to investigate the exposure rate to phthalates among the three exposure routes in indoor environments are currently limited. Objectives: A theoretical exposure ratio between inhalation and oral exposure was calculated based on the total amount of di(2-ethyl-hexyl) phthalate (DEHP) emitted into indoor air and deposited into floor dust in a test house. Methods: Flooring and wallpaper containing DEHP were installed in a test house and the concentration of DEHP in both indoor air and floor dust were monitored for five months. Based on the measured DEHP concentrations, the theoretical total amount ratio of DEHP that could be exposed through inhalation and oral ingestion was calculated. Results: Considering the period of operation in the test house, the theoretical total amount of DEHP through inhalation and oral ingestion exposures in the entire test house space was calculated to be 0.014 mg and 5.5 mg, respectively. The exposure ratio of the two routes between inhalation and oral exposure corresponding to the total DEHP amount in flooring and wallpaper was 6.0×10-7% and 2.3×10-4%, indicating that theoretical oral exposure to DEHP is approximately 380 times higher than inhalation. Conclusions: Monitoring results from a test house has shown that oral exposure is the main exposure route for DEHP in indoor environments. The experimental design employed in this study and theoretical exposure ratio obtained can be applied to investigate actual exposure to DEHP and to determine the exposure characteristics of various types of semi-volatile organic compounds.

Importance of objectives of Housing unit in Home Economics by three systems of action of Home Economics teachers in middle school (중학교 가정과 교사가 인식하는 주생활 영역의 세 행동체계별 목표 중요도)

  • Lee Hee-Joon;Cho Jae-Soon
    • Journal of Korean Home Economics Education Association
    • /
    • v.17 no.4 s.38
    • /
    • pp.117-131
    • /
    • 2005
  • The purpose of this research was to develop objectives of Housing contents in Technology$\cdot$Home Economics by three systems of action and to find out the importance of the objectives of the teachers have taught the class. The 303 teachers from 183 middle schools replied the mail questionnaire during September, 2003. The data were analyzed by SPSS/win. The 21 objectives for each system of action were developed based on the textbooks, teachers guides, and other related references. The importance of the objectives related to communicative system of action was the highest, respectively followed by the ones related to technical and emancipatory systems of action. Indoor Environment & Equipment was more likely to be important than Maintenance & Repairs as the objectives related to communicative system of action, while Usage of Living Space was less likely to be important than the other two sub-units. The importance of the objectives was somewhat differed by the general characteristics of the teachers. The older are the more important the objectives related to technical system of action. Female, Home Economics teachers, who learned philosophy of Home Economics were more likely to think than others objectives related to communicative and emancipatory systems of action to be important. This research showed the teachers' perspectives of the objectives of Housing contents were not the same among respondents and generally supported the previous results from other contents of Home Economics.

  • PDF

An analyses of the noise reduction effect of vegetation noise barrier using scaled model experiments (모형실험을 통한 식생형 방음벽의 소음저감 효과 분석)

  • Haan, Chan-Hoon;Hong, Seong-Shin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.223-233
    • /
    • 2016
  • Design of a vegetation type sound barrier was presented as a noise barrier on the boundary of neighborhood facilities including schools, and apartments. The suggested noise barrier is made of unit blocks that are to be formed by stacking over the wall structure containing the plant and soils in the blocks. The advantage of the vegetation noise barrier is to acquire not only sound absorptive effects of plants and soils, but also sound diffusive effect caused by the irregular surface of the barrier which could eventually mitigate the noise. First, the optimum size of the units to obtain the highest noise reduction was investigated using 1/10 scaled model experiment, and sound attenuation experiments were carried out using a 1/2 mock-up model which is 2 m high and 5 m long. Total 1,137 unit blocks were made of synthetic woods with the size of $10{\times}10{\times}9cm$. These unit blocks were installed on the both side of the 1/2 mock-up steel framed noise barrier. As a result, it was revealed that the block typed vegetation noise barrier has 7 dB higher insertion loss in comparison with the general plane noise barrier. Also, it was found that the appropriate size of unit blocks is $20{\times}20cm$ which has large effect of sound insertion loss.

A System Simulation Model of Proton Exchange Membrane Fuel Cell for Residential Power Generation for Thermal Management Study (가정용 연료전지 시스템의 열관리 해석을 위한 시스템 운전 모델 개발)

  • Yu, Sang-Seok;Lee, Young-Duk;Ahn, Kook-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.19-26
    • /
    • 2010
  • A PEMFC(proton exchange membrane fuel cell) is a good candidate for residential power generation to be coped with the shortage of fossil fuel and green house gas emission. The attractive benefit of the PEMFC is to produce electric power as well as hot water for home usage. The thermal management of PEMFC for RPG is to utilize the heat of PEMFC so that the PEMFC can be operated at its optimal efficiency. In this study, thermal management system of PEMFC stack is modeled to understand the dynamic response during load change. The thermal management system of PEMFC for RPGFC is composed of two cooling circuits, one for controling the fuel cell temperature and the other for heating up the water for home usage. The different operating strategy is applied for each cooling circuit considering the duty of those two circuits. Even though the capacity of PEMFC system (1kW) is enough to supply hot domestic water for residence, heat-up of reservior takes some hours. Therefore, in this study, time schedule of the simulation reflects the heat-up process. Dynamic responses and operating strategies of the PEMFC system are investigated during load changes.