• Title/Summary/Keyword: 주택건축

Search Result 2,312, Processing Time 0.029 seconds

Study on the Performance of the Separate type Heat Pipe Using the Parallel Flow type Heat Exchanger (평행류형 열교환기를 이용한 분리형 히트파이프의 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5045-5050
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this study, we tested the parallel flow type heat exchanger used in a heat exchanger of an automotive air conditioner. And we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. The working fluid was R22, which was filled from 40 to 60 (%vol.) by 10(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

A Study on the Forecasting Model of the Required Cost for the Long-term Repair Plan in Apartment housings (공동주택의 장기수선계획 소요비용 예측모델 연구)

  • Lee, Kang-Hee;Yoo, Uoo-Sang;Chae, Chang-U
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.63-68
    • /
    • 2011
  • Building deterioration would be proceeded by various causes such as physical, social, economic degradation. The deterioration would be inevitably prevented or delayed to get the decent function and performance in various building part and components. The maintenance and management are continued to provide the decent living condition for the household. The maintenance means mainly a repair, including the on-time and longterm plan. The longterm repair would be conducted by the systemic preparation in management activity and a required cost. Therefore, the annual due for the longterm repair plan is important to prepare the repair cost in a required time. In this paper, it aimed at analyzing the longterm repair cost and modelling to forecast the required cost in total area, number of household and time elapse in apartment housing. The estimation model of a repair cost is used with a power function which has a good statistics. Results of this study are shown that the sample has a longterm repair due in a $2,032won/m^2{\cdot}yr$ averagely which is higher than $912won/m^2{\cdot}yr$ in domestic. Second, the longterm repair due is proportionally correlated with the time elapse in both a total area and the number of household. Third, the estimation model for the longterm repair amount is suitable for the power function which is most in any other estimation models. Fourth, the ration of the longterm plan repair due a year to the cumulated longterm amount is about 26%.

Estimating Method of Surface Roughness Using Geographic Information (지리정보를 이용한 지표면조도 산정 방법)

  • CHOI, Se-Hyu;SEO, Eun-Su
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.3
    • /
    • pp.1-10
    • /
    • 2015
  • Rapid urban expansion and densification of the various industrial facilities affect the changes of topography and building in urban areas. Even if buildings proceed with high rise, they get mixed with low-rise buildings such as houses and industrial parks that have existed in the area. This may confuse the designer in estimating a surface roughness, an important factor in calculating the design wind velocity of building. This study analyzed the surface roughness by using a geographic information. Referring to the criteria of each country's building code, this study proposed a method to distinguish the surface roughness depending on the height of the surrounding buildings where the design building is located and calculated the surface roughness using 1:5000 topographic map and GIS. It is expected to solve problems that an existing designer calculates the surface roughness in a subjective manner and to help to design more rational buildings resistant to wind.

An Experimental Study on Material Property of Parking Zone Flooring Occupancy Surface Finishing Used to Environment-friendly.High-liquidity Ceramic Resin Mortar (친환경.고유동 세라믹 수지 모르타르를 이용한 주차장 바닥용 표면 마감의 재료적 특성에 관한 실험적 연구)

  • Lee, Sun-Gyu;Moon, You-Seok;Lee, Hyung-Jun;Lee, Wan-Hwi;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.829-832
    • /
    • 2008
  • Since the early 1980s, the building is dramatically higher increases. Therefore, the shortage of parking spaces as a social problem has been pointed out. The parking lot utilization of underground space is increasing by like this problem solving countermeasure. However, Most of the organic material is used for construction in the parking lot on the floor. The existing parking zone flooring occupancy surface finishing is harmful gases and environmental hormones cause of the worker. The study on the safety of the worker consider using environment-friendly?high-liquidity ceramic resin mortar materials to evaluate the characteristics and physical properties.

  • PDF

Practitioners' Awareness of Planning Features for Environment-Friendly Apartment unit (공동주택 단위주거의 친환경 계획요소에 대한 전문가 의식조사)

  • Kwon, O-Jin;Lee, Yeun-Sook
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.11-18
    • /
    • 2003
  • The purpose of this study was to find out awareness of the environment-friendly planning elements for residential unit space among practitioners. The respondents in this questionnaire survey were 140 practitioners in architecture and interior design field. The major findings of this study were as follows; most of the respondents were aware of the impact of indoor built environment on residents' wellness. In addition, the survey respondents viewed that the factors for planning environment-friendly high-rise apartments were represented by gardening and energy-saving while their perception on the concept excluded comprehensive components affecting residents' life quality. Over 50% of respondents had an experience of applying environment-friendly planning elements in their works, and high frequency appeared on the general planning elements which had been applied special awareness as pro-environmental features. The respondents considered environment-friendly planning elements as important. Specially, space planning and system were considered more likely important in interior design field. In application of environment-friendly planning elements, cost, lack of consumers' awareness of and underdevelopment of environment-friendly materials were of concern. Therefore, the consumer's cognition needs to be improved for wide application about environment-friendly planning element, and then consumers are willing to pay additional construction cost of environment-friendly apartments. At the same time, the current practice that housing developers pass the additional cost on to residents needs to be changed. Then, the quality of life in high-rise residential settings can be improved. More importantly, the exchange and development of the reliable information on environment-friendly planning elements need to be made, and technical support and long-term policy for the development are required. This research showed current status of knowledge and practice in sustainable planning of unit apartment and proved basic information for future direction.

The Field Measurement of Airtightness in the Apartment Buildings (신축공동주택의 기밀성능 실측에 관한 연구)

  • Park, Won seok;Yoon, Jae Ock
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.43-50
    • /
    • 2003
  • Nowdays the apartment is a main type of modernized residential buildings. According to the improvement of construction techniques and functions of windows and doors, recent apartments are enhanced air tightness of windows, doors and building envelopes. As Infiltration is decreased and natural ventilation is reduced, energy could be saved in winter. However, indoor air quality is bad. The air Infiltration of a building could be enlarged by physical actions, such as building designs, constructions and reduction of air tightness which is caused by aging. This research analyzes and measures with KNS-4000P (Sapporo air tightness measurement) the air tightness of the high rise apartments which is recently constructed and not occupied yet. With depressurization method, the KNS-4000 installed on the window and the indoor air-leakage was measured. At that time, Air come out from the edge of the windows and doors because of the pressure differences between indoor and outdoor. We measure the amount of the air as effective air leakage areas. This method of depressurization takes less time to measure than other methods and is less affected from other conditions. We measured infiltration of total 56 household, 29 households S apartment (total floor area : $64.42m^2$) in Balan and 29 households D apartment(total floor area : $78.21m^2$) in Chonan. As a result of the field measurements at October 2003, normalized leakage area of D apartment in Cheonan was $2.05cm^2/m^2{\sim}3.49cm^2/m^2$ (average: $2.77cm^2/m^2$) and normalized leakage area of S apartment in Balan is $1.23cm^2/m^2{\sim}1.68cm^2/m^2$ (average: $1.5cm^2/m^2$).

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Characteristics of Air Flow in the Vestibule with Multiple Fire Doors in an Apartment Building (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 공동주택 부속실내에 다수 출입문의 존재시 기류특성)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.30-36
    • /
    • 2014
  • The pressurized smoke control system in the vestibule is important for fire safety in buildings because it is concerned with egress time of people and the safety of fire fighters. The vestibule pressurization system can prevent smoke from entering the vestibule using differential pressure when fire doors are closed and using the egress velocity when fire doors are open. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule in order to assure the uniform air egress velocity through a fire door when it is open. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where multiple doors are installed and it was found that the reverse flow occurs when the damper position in vestibule is not appropriate.

Building construction process improvement using prefabricated materia (공업화자재의 활용을 통한 공정합리화)

  • Yoon You-Sang;Lee Hyung-Soo;Suh Sang-Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.1 s.13
    • /
    • pp.90-96
    • /
    • 2003
  • The purpose of this study is to present an improvement building construction process by using prefabricated materials. The current slab form work has waste factor by unnecessary process and not complete integration with the finishing process. Therefore the study used value stream analysis methodology for effective improvement of slab form work process. The main contents of the study are as follows; 1) Non-value adding activities were found at existing slab form work process by current state mapping(CSM) 2) Future state mapping(FSM) suggest process Integration to slab form work. 3) Slab form work is analyzed reduction time-cost by prefabricated material. The study recommends that, as a future research, development of tool and technique for the non-value adding activities are eliminated in building construction and application of prefabricated material should be increased.

Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations (오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획)

  • Kim, Jiyoeng;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

A Study of Rating Method Comparison for Heavy-weight Floor Impact Sound based on the Field Test Data in Apartment Houses (공동주택 중량바닥충격음 현장측정을 통한 차단성능 평가방법의 비교검토 연구)

  • Shin, Hoon;Back, Geon Jong;Kook, Chan;Song, Min Jeon;Kim, Sun Woo
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.187-194
    • /
    • 2010
  • Heavy-weight floor impact sound insulation performance criteria have been effective in Korea since the regulation which enforces the standard thickness of slabs in domestic apartment houses should be constructed by 180mm or 210mm was adopted. But every slab does not satisfy this criteria. So, review on existing floor impact sound insulation performance is needed to propose some basic materials for the revision of rating method. To achieve this goal, 63 field test data were checked and analyzed. The results of this study are as follows ; 1) The 210mm thickness slab has the characteristics of deeper level decrease above 120Hz frequency band than that of 180mm thickness slab's. 2) 27.5% of 180mm thickness slabs were satisfied the floor impact sound insulation performance criteria, whereas 65% of 210mm slabs do. 3) Among the main contribution frequency bands for the determination of single rating index, 63Hz was shown as the most contributive band in 210mm slabs. 4) In comparison of single rating index between bang machine test and ball test. there is a big difference between the two and this phenomenon is frequent in 210mm slab results. 5) Rating Methods for the analysis of cross-correlation between the amount of rating, the usefulness of the arithmetic mean could be secured.