• Title/Summary/Keyword: 주입부위

Search Result 229, Processing Time 0.049 seconds

A Study on the Flexural Fatigue Behavior of R/C Beams Repaired with Concrete-Polymer Composites (유기 및 유기재료로 보수된 R/C 보의 휨 피로거동에 관한 연구)

  • 심종성;황의승;배인환;이은호
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.233-241
    • /
    • 1995
  • In this thesis, the fatigue tests were performed on a series of R /C beams repaired with co& crete-lmlyrner composites to investigate the fatigue bahavior. The three point loading system is used in the fatigue tests. In these tests, relations between the repeated loading cycles and mid-span deflections, number of repeated loading cycles when repaired beams were fractured, the bonding performance of repair materials were observed. On this basis, the mid-span deflections, the crack growth and failure mode of repaired R /C beams were studied. A S-N curve was drawn to present the fatigue strength of repaired beams. From the test results, it was shown that behavior of R /C beams repaired with polymer-cement series were very sirnillar to control beam about bonding performance, mid-span deflections and fatigue strength according to S-N curve drawn by the regression anlysis on the fatigue test results.

The Effects of Poloxamer/Sodium Alginate Mixture Barriers on Prevention of Post-Operative Peritoneal Adhesion in Dogs (개에서 Poloxamer / Sodium Alginate 혼합물의 복강 유착 방지 효과)

  • Kim, Ji-Hun;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.324-330
    • /
    • 2009
  • This study was performed to determine the effectiveness of poloxamer/sodium alginate mixture(PX/SA) barriers on prevention of post-operative peritoneal adhesion in dogs. Fifteen mongrel dogs were divided into three experimental groups: non-treated group, 2% Sodium Carboxymethylcellulose (SCMC) treated group and PX/SA treated group. In order to induce adhesions, the anti-mesenteric serosa of the ileum was exteriorized and then abraded in a standard manner by scraping with a scalpel blade to create homogeneous petechial hemorrhagic surface over a 1 ${\times}$ 1 cm area. Solution of SCMC was allowed to spread across the intraperitoneal organs through a catheter using a syringe. PX/SA was simply coated over the abraded tissues. On day before and day 1, 4, 7, and 14 after operation, venous blood specimens were collected for measurement of RBC, total WBC and fibrinogen. The adhesions were blindly assessed 3 weeks later by using a computerized tensiometer. The RBC, total WBC and fibrinogen values of three groups showed no statistical significances. The mean tensile strength(gram force, gf) of formed adhesions on day 21 after surgery was 173.05${\pm}$113.48 in the non-treated group, 111.42 ${\pm}$ 38.25 in the SCMC group, and 69.00 ${\pm}$ 45.07 in the PX/SA group. The tensile strength values for adhesion seperation in PX/SA group was lower than those in SCMC group(p < 0.05) and significantly lower than those in the non-treated group(p < 0.05). Our data suggested that PX/SA should be effective on reducing peritoneal adhesion formation in dogs compared with SCMC. PX/SA may be applicable to preventing post-operative intraperitoneal adhesion in dogs.

The Clinical Experience of The Descending Thoracic and Thoracoabdominal Aortic Surgery (하행대동맥 및 흉복부 대동맥 수술의 임상적 경험)

  • 조광조;우종수;성시찬;최필조
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.584-589
    • /
    • 2002
  • Background : The thoracic and thoracoabdominal aortic surgery is a complicated procedure that has various method of approach and protection. The authors have performed several methods to treat these diseases. Therefore, we attempt to analyze their results and risks. Material and Method: From June of 1992 to August of 2001, we performed 26 cases of thoracic aortic surgery and 10 cases of thoracoabdominal aortic surgery. There were 17 aortic dissections, 17 aortic aneurysms, one coarctation of aorta and one traumatic aortic aneurysm. The thoracic aortic replacement was performed under a femorofemoral bypass, an LA to femoral bypass, or a deep hypothermic circulatory arrest. The thoracoabdominal aortic replacement was performed under a femorofemoral bypass or a pump assisted rapid infusion. Result: There were 7 renal failures, 11 hepatopathies, 7 cerebral vascular accidents, 2 heart failures, 5 respiratory insufficiencies, and 2 sepsis in postoperative period. There were 9 hospital mortalities which were from 2 bleedings, 2 heart failures, 2 renal failures, a sepsis, a respiratory failure, and a cerebral infarction. There were 3 late deaths which were from ruptured distal anastomosis, cerebral infarction, and pneumonia. Conclusion: Deep hypothermic circulatory arrest was not good supportive methods for thoracic aortic replacement. Total thoracoabdominal aortic replacement was a high risk operation.

The Analgesic Effect and the Mechanism of Electroacupuncture on Thermal Hyperalgesia in the Rat Model of Collagenase-induced Arthritis: Mediation by Adrenergic Receptors (Collagenase-induced Arthritis Rat Model에서 Thermal Hyperalgesia에 대한 전침(電鍼)의 진통효과(鎭痛效果) 및 기전연구: Adrenergic Mechanism에 대(對)한 연구(硏究))

  • Seo, Byung-Kwan;Park, Dong-Suk;Baek, Yong-Hyeon
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.57-67
    • /
    • 2011
  • 목적 : Collagenase-induced osteoarthritis(OA) 동물 모델에서 전침의 adrenergic mechanism을 연구하고자 한다. 방법 : Collagenase-induced arthritis(CIA)를 유발하기 위하여 5주령의 male Sprague-Dawley rat의 뒷다리 좌측 무릎 관절에 0.05ml의 4mg/ml collagenase solution을 intra-articular 주입하고, 다시 4일 후에 같은 부위에 같은 농도의 collagenase solution을 intra-articular boosting injection 시행한 뒤, gross, histopathological features 및 biomarker activity 변화를 관찰하였다. 예비실험을 통하여 CIA rat model에서 진통효과를 발휘하는 것으로 확인한, 족삼리(足三里) ($ST_{36}$)에 대한 저빈도 train pulse EA stimulation (2Hz, 0.07 mA, 0.3ms)을 침치료 방법으로 적용하였다. 전침의 진통기전을 확인하기 위하여, ${\alpha}1$-adrenergic antagonist (prazosin, 1 mg/kg, i.p.), ${\alpha}2$-adrenergic receptor antagonist (yohimbine, 2mg/kg, i.p.), ${\alpha}1$-adrenergic receptor agonist(phenylephrine, 2mg/kg, i.p.), ${\alpha}2$-adrenergic receptor agonist(clonidine, $40{\mu}g$/kg, i.p.)을 전침시행 20분 전에 복강 내로 전처치하였다. Tail flick unit(Ugo Basile Model 7360)을 이용하여 열자극에 대한 통증역치를 측정하였다. 결과 : 퇴행성관절염 징후(gross, histopathological features)와 통증역치의 변화가 최대값을 나타내는 CIA 유발 4주차에 저빈도 전침자극(train pulse, 2Hz, 0.07mA, 0.3ms)을 족삼리($ST_{36}$)에 적용하였으며, 족삼리 전침의 진통효과는 ${\alpha}2$-adrenergic receptor antagonist(yohimbine, 2mg/kg, i.p.)전처치에 의해 억제되었으나, ${\alpha}1$-adrenergic antagonist(prazosin, 1 mg/kg, i.p.)전처치에는 억제되지 않았다. 또 ${\alpha}2$-adrenergic receptor agonist(clonidine, $40{\mu}g$/kg, i.p.)의 전처치를 통하여 유의한 synergistic analgesic effect가 관찰되었으나, ${\alpha}1$-adrenergic receptor agonist(phenylephrine, 2mg/kg, i.p.)의 전처치는 전침의 진통효과에 synergistic effect를 미치지 않는 것으로 나타났다. 결론 : 저빈도 족삼리 전침은 CIA로 유발된 염증성 통증에 대하여 진통효과를 발휘하며, 이는 ${\alpha}2$-adrenergic receptor에 의하여 매개되는 것으로 보이며 ${\alpha}1$-adrenergic receptor는 영향을 미치지 않는 것으로 사료된다.

자성유체 윤활제의 개발 동향

  • 김영규;심우전;김청균
    • Tribology and Lubricants
    • /
    • v.12 no.1
    • /
    • pp.1-5
    • /
    • 1996
  • 자성유체는 자연에서 추출한 것이 아니라 자화성(Magnetizability)과 유도성(Flowability)을 동시에 갖도록 합성한 특수액체이다. 자성유체는 1960년대 중반에 미국의 NASA에서 처음 개발된 이후로 윤활, 밀봉, 감쇄, 의료 등의 분야에서 응용연구가 많이 진행되었기 때문에 고도의 정밀도를 요하는 항공, 우주산업, 컴퓨터와 반도체 분야 등에서 실용화가 크게 진전되고 있다. 특수물질일 자성유체는 전기적으로 도체인 10nm 정도의 미세한 자기입자(Magnetic particles)에 코팅을 한 후, 이것을 물, 탄화수소, 플루오르카본, 에스터 등의 매개유체(Carrier Fluids)에 혼합시켜서 콜로이드 상태로 사용하게 된다. 자성유체는 미세한 자기입자들이 매개유체내에서 서로 충돌하면서 반발력을 발생시켜서 상호간에 늘 콜로이드 상태를 유지하고 있으며, 이 특수유체가 자기장의 영향을 받게 되면 점도가 증가하면서 특이한 성질을 갖게 된다. 상대 접촉 운동면에 경계마찰이나 혼합마찰을 하게 되면 윤활상태는 비교적 나쁘다. 이러한 마찰지역에 콜로이드상의 자성유체 윤활제를 공급하면 기존의 윤활제에 비하여 대단히 효과적으로 윤활을 할 수 있게 된다. 그러나 자성유체 윤활제가 마찰부위에 원활하게 공급하기 위해서는 미끄럼 마찰부에서 자기장을 잘 형성시킬 수 있는 도체이어야 하기 때문에 특별한 윤활 시스템 설계가 제시되어야 한다. 자성유체 윤활제는 합성으로 제조된 특수물질로 여러가지 장점을 갖고는 있으나 기존 윤활유와의 적합성, 마찰열, 밀봉압력 등의 조건에서 제한적으로 사용될 수 밖에 없으므로 항공, 우주 산업이나 석유 화학분야와 같이 특수 환경에서만 사용되고, 또한 기존의 광유계 윤활제에 비하여 대단히 고가하는 문제점을 갖고 있다. 그러나 윤활 마찰면의 다양화와 가혹한 사용조건은 자성유체 윤활제의 연구개발 필요성을 크게 증대시키고 있다.xed Effects Model)을 결정하고, 각각에 해당하는 통계모형을 구축하였다. 이 결과 (1) 업종 및 기업규모별로 그룹간에 유의한 특성이 발견되었으며, (2) R&D 및 광고투자는 기업의 시장성과를 설명하는 중요한 변수이나, (3) R&D 투자의 경우는 광고에 비해 불확실성이 존재하는 것으로 나타났고, (4) 수리모형에서 도출된 한계원리가 통계모형에서도 유효한 것으로 드러났다.등을 토대로 한 10대 산업을 육성하기 위하여 과학기술부는 기술수요조사를 바탕으로 49개 주요기술을 도출하여, 과학기술 일류 국가 실현, 국민소득 2만불 달성이라는 국가적 슬로건을 내걸고 “차세대 성장동력” 창출을 위한 범정부차원의 기획과 연구비의 집중투자를 추진하고 있다.달성하기 위해서는 종합류류 전산망의 시급한 구축과 함께 화물차의 적재율을 높이고 공차율을 낮출 수 있는 운송체계의 수립이 필요한 것으로 판단된다. 그라나 이러한 화물전용차선의 효과는 단기적인 치유책일 수밖에 없기 때문에 물류유통 시설의 확충을 위한 사회간접자본의 구축을 서둘러 시행하여야 할 것이다.으로 처리한 Machine oil, Phenthoate EC 및 Trichlorfon WP는 비교적 약효가 낮았다.>$^{\circ}$E/$\leq$30$^{\circ}$NW 단열군이 연구지역 내에서 지하수 유동성이 가장 높은 단열군으로 추정된다. 이러한 사실은 3개 시추공을 대상으로 실시한 시추공 내 물리검층과 정압주입시험에서도 확인된다.. It was resulted from increase of weight of single cocoon. "Manta"2.5ppm produced 22.2kg of cocoon. It is equal to 9% increase in index, as compared to that of control. In case

Development of Effective Screening Method for Efficacy Test of Trunk Injection Agents Against Pine Wood Nematode, Bersaphelenchus xylophilus in Japanese Black Pine, Pinus thunbergii (곰솔(Pinus thunbergii)에서 소나무재선충(Bersaphelenchus xylophilus) 나무주사 약제의 효율적인 평가법 개발)

  • Shin, Won Sik;Jung, Young Hack;Lee, Sang Myeong;Lee, Chae Min;Lee, Chang Joon;Kim, Dong Soo;Mun, Il Sung;Lee, Dong Woon
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.4
    • /
    • pp.440-449
    • /
    • 2015
  • Pine wood nematode (PWN), Bursaphelenchus xylophilus is one of the most serious pests of pine tree. Trunk injection of some nematicides in tree is well known as an effective control method. However there are some limitating factors which hindering the efficacy of trunk injection in field or potted tree. In this study we suggested easy and useful alternative screening methods of nematicides against PWN. Reproduction of PWN was influenced by tree twig moisture (high reproduction in high moisture trig) and paraffin coating was 78.6% reduced moisture loss in tested twig. There were no reproduction different in up and down site from infection site of twig at 1 month after inoculation of PWN and also distance (5 and 10 cm) from inoculation site of PWN did not influence the reproduction of PWN. Numbers of reproduced PWN were higher with decreasing diameter of twig. Numbers of reproduced PWN were similar to P. thunbergii and P. densiflora. However reproduction was increased depending on high inoculation density and longer propagation period. When inoculation of PWN on cut twig injected with emamectin benzoate 2.15% EC and morantel tartrate 8% SL in trunk of Pinus thunbergii in the field, PWN number were significantly reduced than untreated control. We suggest this screening method for PWN control agents.

Radiographic Evaluation of Small Intestinal Diameter in Small Breed Dogs (소형견에서 소장 직경의 방사선학적 평가)

  • Choi, Ho-Jung;Kim, Soo-Chan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.301-305
    • /
    • 2012
  • The purpose of the present study was to prove our empirical tendency of relatively high small intestinal diameter (SI) to fifth lumbar vertebral height (L5) ratio, which has been used in dogs. In this study, the ratio of SI/L5 was determined in small breed dogs weighing less than 5 kg. In addition, the effect of large volume of contrast media on the intestinal dilation was determined by performing upper gastrointestinal contrast study. Abdominal radiography and upper gastrointestinal series were performed in twelve healthy dogs weighing less than 5 kg. Small intestinal diameter (SI), fifth lumbar vertebral height (L5), and twelfth rib diameter were measured on abdominal radiographs. The range of values of SI/L5 is from 1.03 to 2.26 in plain radiography, and from 1.55 to 2.5 in contrast studies. Contrast agent significantly increased small intestinal diameter, and could be considered as mildly dilated intestinal model. Therefore, a value of 2.1 for SI/L5 is recommended as the upper limit of the normal range suggesting nonobstructive intestinal dilation.

An Experimental Study for the Prevention of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit (가토 정맥에서 CT 조영제의 혈관외유출 예방을 위한 EDA 시스템의 실험적 연구)

  • Kweon, Dae-Cheol;Jeong, Seok-Hee;Yang, Sung-Hwan;Cho, Mun-Son;Jang, Keun-Jo;Kim, Sun-Geun;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.238-245
    • /
    • 2006
  • To assess the ability of an extravasation defection accessory (EDA) to detect the clinically important extravascular Injection of iodinated contrast material that was delivered with an automated mechanical power injector. The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The EDA system was composed of a strain gage, an amplifier and a computer-based system. In the rabbit experimental cases, there were seven true-positive cases (range of the extravasation volumes: $14{\sim}23 ml$). The algorithm results showed seven true-positive cases (range of the extravasation volumes: $7{\sim}16ml$), nineteen true-negative cases, two false-positive cases and no false-negative cases. The EDA system had a sensitivity of 100% and a specificity of 90% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

  • PDF

Contrast Enhanced Cerebral MR Venography: Comparison between Arterial and Venous Triggering Methods (조영 증강 자기공명정맥 촬영술에서의 동맥과 정맥 triggering 방법의 비교)

  • Jang, Min-Ji;Choi, Hyun-Seok;Jung, So-Lyung;Ahn, Kook-Jin;Kim, Bum-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.152-158
    • /
    • 2012
  • Purpose : To compare the arterial and venous detection sites of triggering methods in contrast-enhanced-MR-venography (CE-MRV) for the evaluation of intracranial venous system. Materials and Methods: 41 healthy patients underwent CE-MRV with autotriggering at either the cavernous segment of internal carotid artery with an inserted time-delay of 6 seconds (n = 20) or the superior sagittal sinus without any timedelay (n = 21). 0.1 mmol/kg gadolinium-based contrast material ($Magnevist^{(R)}$, Schering, Germany) was intravenously injected by hand injection. A sagittal fast-spoiled-gradient-echo-sequence ranging from one ear to the other was performed (TR/TE5.2/1.5, Matrix $310{\times}310$, 124 sections in the 15-cm-thick volume). 17 predefined venous structures were evaluated on all venograms by two neuroradiologists and defined as completely visible, partially visible, or none visible. Results: The rate of completely visible structures were 272 out of 323 (84%) in the arterial triggering CE-MRV and 310 out of 340 (91%) in the venous triggering CE-MRV. The venous triggering CE-MRV demonstrated an overall superior visualization of the cerebral veins than the arterial triggering CE-MRV (Fisher exact test, p < 0.006). Conclusion: CE-MRV using venous autotriggering method provides higher-quality images of the intracranial venous structures compared to that of arterial.

Development of Novel Assistive Device for Improving Usability of BVM (인공호흡기 사용성 향상을 위한 새로운 보조기구 개발)

  • Jeon, Gang-Hyun;Park, Yong-Jai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.420-426
    • /
    • 2020
  • In this study, an assistive device for BVM (Bag Valve Mask) was developed. When emergencies occur, rescuers must perform artificial respiration within four minutes utilizing suitable BVM. If not, the patient can suffer serious damage within their brain and body systems. The rescuer must execute artificial respiration until the patient arrives at the hospital. In the process of artificial respiration, the rescuer can feel fatigued in their forearm muscles, particularly those who may have smaller hands or weaker muscle strength. Many products have been developed to solve these problems, but these products are difficult to market and commercialize because of their volume, size, and difficulty of use. In this paper, the BVM assistive device that has been previously manufactured was improved, and an attempt was made to devise a new method that reduces the burden on the user. The BVM assistive device can be divided into three-parts: a head part for compressing the air bag, which can control the amount of air; the body part for coupling with BVM; and finally, the handle that can rotate for better use on various postures of patients. Throughout the experiment, the assistive device could inject an equal amount of air into the patients. As a result, the rescuer could feel less fatigue and inject a suitable amount of air to emergency patients during artificial respiration.