• Title/Summary/Keyword: 주상변압기

Search Result 99, Processing Time 0.049 seconds

A Study on the Development of Low-loss Type Hybrid Insulation Pole Transformers and (저손실형 복합절연 주상변압기 개발 및 단락특성에 관한 연구)

  • Min, Yun-Hong;You, Ho-Keun;Bae, Sun-Ki;Kim, Ho-Chul;Lee, Yun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.607-612
    • /
    • 2002
  • This paper presents the first domestic model product of hybrid Insulation low-loss type pole transformer, with increased overload ability, increased life, reduced loss, focusing improved short-circuit characteristics. The capacity of this transformer is 100 KVZ, rates first voltage 13200 V and secondary voltage 230/115 type. The volume of model transformer that was produced in high temperature using hybrid insulation can be reduced to 10-20% in comparison with that of present transformer with the same capacity. In this paper, we did short-circuit test and tested general characteristics of model transformer. In addition, we suggested design application new concept and methods thorough this experiment.

  • PDF

The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer (주상용 몰드 변압기의 온도분포 해석과 온도상승 시험)

  • Cho, Han-Goo;Kim, Seok-Sou;Lee, Un-Yong;Lee, Jong-Doug
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.245-247
    • /
    • 2001
  • In this paper, the temperature distribution and thermal stress analysis of 50kVA pole mold transformer for power distribution are investigated by FEM program. The temperature rise test of designed mold transformer is carried out and test result is analyzed compare to simulation data.

  • PDF

The temperature distribution and thermal stress analysis of method transformer for power distribution system (배전용 주상 몰드변압기의 온도분포 및 열응력 해석)

  • Lee, U.Y.;Cho, H.G.;Kim, S.S.;Park, Y.D.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1900-1902
    • /
    • 2000
  • In this paper, the temperature distribution and thermal stress analysis of mold transformer for power distribution system is investigated by FEM. Filler type epoxy is applied for good cooling effect in mold transformer.

  • PDF

A Study of the Development of the Temporary Transformer System for the Replacement of Bum-out Pole Transformer (소손 주상변압기 교체를 위한 임시송전시스템 개발에 관한 연구)

  • Lee, Jung-Kyun;Yun, Young-Mo;Jeun, Si-Sik;Lee, Jae-Heon;Jeong, Dong-Ju;Park, Yong-Beom;Kim, Jeom-Sik;Jo, Seong-Mun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.43-46
    • /
    • 2009
  • This paper describes a development of the temporary transformer system and method. The failure causes are genrally divided into problems in manufacturing, mounting and operating. To replace the bum-out pole transformers developed various facilities, power cable clamp, the control panel of self-sensing device and voltage connection box etc. That is more effective to establish the emergency transmission systems for the non interruption replacement of distribution transformers.

  • PDF

Life Loss of Pole Mounted Transformers by Thermal Aging (열 열화에 의한 주상변압기의 수명 손실)

  • Joung, Jong-Man;Lee, Byeong-Seong;Song, Il-Kewon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.209-213
    • /
    • 2005
  • To enhance the reliability of distribution transformers in service and to reduce the cost of maintaining and replaceing these, the condition and life of those insulating system should be evaluated accurately and the time to replace should be determined economically. Since the transformer failures related to insulation failure indicates that the primary cause is normally mechanical failure of integrity due to loss of mechanical strength as a result of degradation, the tensile strength characteristics of paper during ageing under accelerated conditions in insulating oil and research trends for assessing the life of insulating paper were investigated.

  • PDF

The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers (가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가)

  • 이병성;송일근;이재봉;한상옥
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

Failure Cause Analysis of Pole Transformers (주상변압기 고장원인분석)

  • Jung, Jong-Wook;Lee, Byung-Sung;Lee, Jae-Bong;Joun, Jae-Keun;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.503-507
    • /
    • 2002
  • This paper describes the symptoms with the failure causes of pole transformers analyzed at KEPCO branch offices' request in 2001, and ultimately aims for devising proper countermeasures against the failures. The failure causes are generally divided into problems in manufacturing, mounting and operating. The pole transformers encounter the failure with unique mechanisms. To verify the mechanisms to failures and help devise proper countermeasures, a flowchart is proposed based on the authors' experience and foreign case studies. The failure causes of pole transformers can be analyzed more exactly by using the flowchart.

  • PDF

Analysis of Performance Test of Low-Loss Pole Transformers for distribution Line (저손실형 일단접지 주상변압기의 성능평가 분석)

  • Park, Y.C.;Kim, K.U.;Heo, J.C.;Hwang, B.K.;Roh, H.N.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1811-1813
    • /
    • 2001
  • In order to obtain the useful data for quality control of the pole transformer and supply the stable electric power in distribution line, The evaluation of performance for low-loss pole transformer had been performed for new products and ones under operation for several years in distribution line. As the results, we found that the rate of fail were very high in gaskette, short-circuit strength and temperature-rise test, especially 48 percent in gaskette test.

  • PDF

A study for the overload and fault protective device of pole transformers (주상변압기 과부하 및 고장보호장치 개발에 관한연구)

  • Choi, Bong-Il;Lim, Chang-Ho;Kim, Chang-Kyung;Kim, Young-Rae;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.67-69
    • /
    • 1992
  • This paper presents the new protective device which is developed specifically for use in oil filled distribution transformers. This device is mounted Inside of the transformer and connected between the secondary winding and the secondary bushings. It provides both fault and overload protection to the transformer, and visual warning of the existence of uneconomical loading conditions. It Is available in thermal/magnetic operating device depending upon fault duty required.

  • PDF

A Study on Suggestion of Insulating Oil Ageing Degree in Pole-Transformer by Absorbance (흡광도법에 의한 주상변압기 절연유의 열화판정기준 설정에 관한 연구)

  • Lee, Dong-Zoon;Jung, Jong-Uk;Kim, Kyung-Hwa;Kwak, Hee-Ro;Yun, Yong-Ja
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1851-1853
    • /
    • 1996
  • In this paper the criteria for insulating oil condition of pole transformer were suggested by applying the UV-Visible spectrophotometric method. Ageing of insulating oil caused the change in absorbances of oil os well os the deterioration of electrical properties of oil. By comparing the electrical properties such as $tan{\delta}$ and breakdown voltage with the UV-Visible absorbances of oil, criteria for absorbance values determining oil condition were established. This UV-Visible spectrophotometric method might be applied in ageing analysis of oil and be expected to replace the current method.

  • PDF