Temperature Setpoint Algorithm for the Cooling System of a Tilting Train Main Transformer (틸팅열차 주변압기 냉각시스템의 온도설정알고리즘)

  • Han, Do-Young;Noh, Hee-Jeon;Won, Jae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.387-392
    • /
    • 2008
  • In order to improve the efficiency of the main transformer in a tilting train, the optimal operation of a cooling system is necessary. For the development of the optimal control algorithm of a cooling system, the mathematical model of a main transformer cooling system was developed. This includes the dynamic model of a main transformer, an oil pump, an oil cooler and a blower. The system algorithm of a cooling system, which consists of the temperature setpoint algorithm and the temperature control algorithm, was developed. Optimal oil temperatures of the inlet and the outlet of the main transformer were obtained by considering the total electric power consumption of the system. The oil inlet temperature was controlled by the blower and the oil outlet temperature was controlled by the oil pump. A simulation program was developed by using the mathematical model and the system algorithm. Simulation results showed that the system algorithm developed from this study may be effectively used to control the main transformer cooling system in a tilting train.

  • PDF

The Investigation for the Cases and Cause of the Failures of the EPDM Sealed SOVs Used in the High Temperature Circumference (고온주변에서 사용되는 에틸렌-프로필렌-디엔 합성고무 봉인물질을 가진 솔레노이드구동밸브의 작동실패 사례 및 원인 분석)

  • Lee J.;Seo J. K.;Park C. T.;Kim Y. I.;Yoon J.
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.82-85
    • /
    • 2004
  • EPDM 봉인물질을 가진 SOV의 작동실패 사례 및 원인을 분석해보면 많은 SOV 고장(SOV failures)은 결국 EPDM 봉인물질이 원인인 것으로 나타났다. SOV 고장은 SOV가 그것의 설계 범위를 초과하는 주위 온도(ambient temperature)에 노출되어 있었기 때문에 발생되었다. 그러한 SOV 고장은 증기누설, 주위 온도의 부정확한 평가 등의 원인에 의해 발생되었다. 또한 SOV 고장은 연속적인 coil의 여기시 발생하는 가열(heatup from energization)로 인해 수명이 단축되는 영향이 서비스 수명 기간에 적절하게 포함되지 않았기 때문에 발생되었다 많은 발전소 운용자는 이러한 사실을 알고 있지 못하였으며 결과적으로 서비스 수명 기간이 과도 예측되는 결과가 초래되었다 SOV의 또 다른 연성(Soft) 봉인물질로, 열저항 특성이 EPDM에 비해 약 $50^{\circ}C$ 정도 우수한 Viton 봉인물질에 대한 특성이 제시되었다. 더불어 현재 많은 국외 솔레노이드구동밸브 전문 생산업체들이 Viton 재료를 옵션으로 채택하고 있는 추세이다. 그러나 고온주변에서 지속적으로 노출되어 있는 환경에서 Viton이 EPDM의 문제점을 어느 정도 해결할 수 있는 지의 여부는 현재 결론 내리기 어려울 것으로 판단되며, 향후 이를 채택한 SOV의 운전경험을 계속 주시할 필요가 있을 것으로 판단된다.

  • PDF

Heat Gains and Occupant′s Thermal Comfort in Computer Room (컴퓨터실의 열취득과 재실자 온열 쾌적감 연구)

  • 김원태
    • Science of Emotion and Sensibility
    • /
    • v.3 no.2
    • /
    • pp.1-8
    • /
    • 2000
  • 본 연구에서는 기존의 공조방식 및 본 연구에 제안된 개별환경제어시스템(PEM)으로부터 재실자가 거주하여 사용하고 있는 컴퓨터룸(CR)에 대해 기하학적으로 3차원 시뮬레이션을 수행하여 CR의 열취득과 재실자 온열 쾌적감을 감성공학적 측면에서 분석하였다. 본 연구로부터 바닥으로부터 공기를 유입하여 천정으로 유출하는 바닥취출공조(TAM)방식이 실내 환경 개선에 유리하고 디퓨저만을 통하여 공기가 유입되어 천정과 바닥으로 공가가 유출되는 개별공조(PEM) 방식은 열적 냉각 성능은 좋으나 컴퓨터와 재실자 주변에 강력한 ㅐ순환 유동을 유인하여 실내 환경의 쾌적감 측면에서는 불리하다. 그러나 PEM과 TAM방식의 결합이 감성공학적 온열특성 분포로부터 CR의 재실자 주변온도 분포에 최적임을 알 수 있다.

  • PDF

Numerical simulation of urban cooling effect by thermal environment of Lake area (호수주변지역의 열환경 변화에 따른 도시 냉각효과 수치모의)

  • 이화운;오은주;김민선
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.159-160
    • /
    • 2002
  • 도시가 개발됨에 따라 녹지 등의 자연지면이 포장지면으로 바뀌고, 대량의 열과 오염물질이 대기중으로 배출되고 있다. 그 결과 도시는 주변지역보다 온도가 높은 고온화 현상, 풍속의 감소와 함께 운량, 안개일수, 강수량의 변화, 지표면의 증발량 감소에 의한 상대습도의 저하 등의 도시의 고유한 기후특성을 가진다. 이러한 도시의 기후특성 중 가장 뚜렷한 특징은 기온의 고온화현상이다. (중략)

  • PDF

Thermodynamic Energy Balance Analysis of Underground Lined Rock Caverns (LRC) for Compressed Air Energy Storage (CAES) (복공식 지하 압축공기에너지 저장공동의 열역학적 에너지수지 분석)

  • Kim, Hyung-Mok;Park, Do-Hyun;Ryu, Dong-Woo;Choi, Byung-Hee;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.21 no.4
    • /
    • pp.297-306
    • /
    • 2011
  • In this paper, we performed thermodynamic energy balance analysis of the underground lined rock cavern for compressed air energy storage (CAES) using the results of multi-phase heat flow analysis to simulate complex groundwater-compressed air flow around the cavern as well as heat transfer to concrete linings and surrounding rock mass. Our energy balance analysis demonstrated that the energy loss for a daily compression and decompression cycle predominantly depends on the energy loss by heat conduction to the concrete linings and surrounding rock mass for a sufficiently air-tight system with low permeability of the concrete linings. Overall energy efficiency of the underground lined rock caverns for CAES was sensitive to air injection temperature, and the energy loss by heat conduction can be minimized by keeping the air injection temperature closer to the ambient temperature of the surroundings. In such a case, almost all the heat loss during compression phase was gained back in a subsequent decompression phase. Meanwhile, the influence of heat conductivity of the concrete linings to energy efficiency was negligible.

음성통신을 위한 잡음처리 기술

  • Sin, Jong-Won;Jang, Jun-Hyeok;Kim, Nam-Su
    • Information and Communications Magazine
    • /
    • v.24 no.4
    • /
    • pp.27-35
    • /
    • 2007
  • 음성 통신을 할 때 배경 잡음이 존재하게 되면 일반적으로 음질이 저하된다. 이것은 잡음 자체가 듣기 싫다거나 음성을 더 작게 들리게 만들기 때문이기도 하고 음성 코덱이 잡음이 섞이지 않은 깨끗한 음성에 최적화되어 있어서 잡음이 섞인 음성에 대한 코딩 효율이 떨어지기 때문이기도 하다. 이 논문에서는 잡음에 의한 음성 통신의 품질 저하를 막기 위한 방법으로서 음성 향상(speech enhancement) 기술과 음성 강화(speech reinforcement) 기술에 대해 소개한다. 음성 향상 기술이란 전송부의 마이크에서 녹음된 잡음과 음성이 섞인 입력 음성으로부터 깨끗한 음성을 추정하는 기술을 말한다. 음성 향상 기술은 상당히 오랜 기간 동안 연구되어 온 기술이며, 최근에는 각 파라미터의 분포에 의존하는 방법보다 확률 모델에 기반한 방법이 각광을 받고 있으며 인간의 청각 특성을 고려한 음성 향상 방법도 제안되고 있다. 음성 강화 기술이란 수신단에서 주변 잡음에 따라 전송되어 온 음성을 주파수별로 증폭하여 더 잘 들리도록 만드는 기술이다. 음성 향상이 내 주위의 잡음이 상대방에게 들리는 음성에 미치는 영향 혹은 상대방 주변의 잡음이 나에게 들리는 소리에 미치는 영향을 줄여주는 기술이라면 음성 강화는 내 주위의 잡음이 나에게 들리는 음성에 미치는 영향을 상쇄해 주는 기술이다. 이 경우 주변 잡음은 어떤 전자 시스템도 거치지 않고 귀로 직접 들어오기 때문에 잡음 자체를 줄여 주는 것은 힘들고 전송되어 온 음성을 적절히 증폭 혹은 변형함으로써 귀에 들리는 음질 또는 명료성을 개선하게 된다. 이 논문에서는 통계 모델을 기반으로 한 음성 향상 기법과 인간의 청각 특성을 고려한 음성 향상 기법, 그리고 음성 강화 기법에 대해 설명한다.을 시도한 결과 안정적이고 반복 가능한 급성 심부전 모델을 얻을 수 있었다. bench scale실험결과와 같이 AOC는 배수관망에서의 박테리아 증식과 크게 상관관계를 갖고 있는 것으로 밝혀졌다.)', 'have a headache (2.10±0.79)', 'poor memory (2.09±0.83)', 'no appetite (1.99±0.85)', As for the correlation between iron parameter and clinical symptoms related to anemia, the hematocrit rate was negatively correlated with 'get a cold easily', 'pale face', 'feeling blue', 'difficult digestion' (p<0.05). The level of iron was negatively correlated with 'tired out easily', 'get a cold easily' (p<0.05) and TS (%) were negatively correlated with 'tired out easily (p<0.05)', 'get a cold easily (p<0.01). Our study resulted that the prevalence of a iron deficiency of a middle school girl is very high, therefore the guidelines for iron supplementation and nutritional education to improve their iron status should be provided.한 질소제거를 N-balance로부터

Effects of Freezing a Backfill Material under Undrained Condition on a Buried Pipe (포화 사질토 뒷채움재의 비배수 동결에 의한 매설 강관의 거동 - 실대형 모형실험 연구 -)

  • Kang, Jae-Mo;Lee, Jang-Guen;Kim, Hak-Seung;Lee, Sang-Yoon;Ryu, Byung-Hyun;Cho, Nam-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.8
    • /
    • pp.39-47
    • /
    • 2014
  • Frost heaving and thawing settlement cause unexpected stress around buried pipelines, which results in deformation and permanent demage. A large scale laboratory test has been performed to observe deformation, stress, and temperature of a buried pipe during atmospheric temperature changes. From the experimental results, the stress concentrated around the buried pipe is inevitable and deformation is caused by the frost heaving. Even though backfill materials are sandy soils which are normally assumed to be non frost susceptible, it is revealed that frost demage can happen due to drainage condition, the level of ground water table, and water content.

Experimental Relationship between Electrical Impedance of a Steel Wire and Applied Stress, Temperature, and Excited Frequency (강선의 전기적 임피던스와 응력, 온도 및 주파수 사이의 실험적 관계)

  • Nguyen, Duy-Hung;Kim, Byeong Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.183-189
    • /
    • 2020
  • This paper presents an experimental investigation regarding the sensitivity of electrical impedance of a steel wire to tensile stress, ambient temperature and induced frequency. For various stress levels and temperatures, the electrical impedance of a steel wire has been measured on a self-sensing system. The three experimental cases are carried out at various temperature conditions, stress levels and applied frequencies. If the temperature increases and stress level decreases at a given frequency, the electrical impedance on the steel wire increases. The results show that the correlation between electrical impedance and temperature is a linear relationship at all stress levels. It is noted that the sensitivity of impedance to temperature is much higher than the stress.

Thermo-hydraulic Numerical Analysis for the Leakage of Buried District Heating Pipe (열수송관의 누수에 대한 열-수리적 수치해석)

  • Shin, Hosung;Hong, Seung-Seo
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.3
    • /
    • pp.17-26
    • /
    • 2022
  • Domestic district heating system needs safety management guidelines using the change of surface temperature to detect damages to buried heat pipes. This paper performed numerical analyses on the temperature change of ground surface due to the burial and leakage of heat pipes. Temperature difference between the ground surface above the buried heat pipes and the surrounding surface rises to a crescendo between 3 am and 8 am. It is more significant in winter rather than in summer. Low groundwater level magnifies the temperature increase of the ground surface by the heat pipe, which is smaller in the asphalt pavement than in the bare soil. Without leakage of the buried heat pipe, the temperature increment on the ground surface by the heat pipe is within 3.0℃ in the bare soil and 3.5℃ in the asphalt pavement. Leakage of the supply heat pipe in the bare soil increases the temperature on the ground surface gradually in the summer but rapidly in the winter. Asphalt pavement shows a lower increment and increasing rate of the temperature on the ground surface due to pipe leakage than bare soil surface. And leakage on both sides of the supply pipe takes 1-2 days for the temperature difference from the surrounding soil surface to reach 10℃.

The Estimation of Marine Environmental Capacity for the Reception of Cooling Water from HTPP in Southern Waters of Cheju Island using a 3-D Hydrodynamic Model (화순화력발전소 주변해역의 온배수 환경용량 산정)

  • Kim Gwang-Su;Choi Young-Chan;Lee Moon-Jin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.3-12
    • /
    • 2000
  • The field surveys and the measurements of seawater temperatures were conducted every month from 1997 to 1999, and the distributions of seawater temperature were simulated and reproduced by a three dimensional hydrodynamic numerical model over the southern waters of Cheju island. In order to estimate the marine environmental capacity for the reception of the heat loads of cooling water discharged from Hwasoon Thermal Power Plant(HTPP) in the study area, the simulations for predicting the situation of unfavorable environment in which marine organisms might not be satisfied with change in seawater temperature were peformed using a three dimensional hydrodynamic numerical model by controlling quantitatively the heat loads of cooling water from HTPP Currently, HTPP discharges cooling water of 35.9℃ into the sea as much as 112,800m³/day in summer. As the results of simulations, the more the heat loads from the power plant increase, the more increase the seawater temperatures around the water areas adjacent to the power plant. In case the heat loads of cooling water from HTPP become about 5 times as high as the present loads, seawater temperatures at near-shore waters adjacent to HTPP appear to be increased to the extent of 0.5℃ above the existing seawater temperature in summer. The marine environmental capacity for the reception of thermal discharge from HTPP is estimated to be about 530×10/sup 6/kcal/day which is equivalent to the increase of a factor of 2 in the temperature of cooling water without any change in the discharge rate of cooling water or which is equivalent to the increase of a factor of 4.6 in the discharge rate of cooling water without any change in the temperature of cooling water. Comparing the case of the increase in the discharge rate of cooling water with the case of the increase in the temperature of cooling water on the basis of the same heat loads of 530×10/sup 6/kal/day, the former case is expected to increase seawater temperature a little higher and to extend the area affected by heat loads a little broader.

  • PDF