• 제목/요약/키워드: 주모형

검색결과 50건 처리시간 0.024초

자유항주모형시험과 회귀분석을 통한 선체 동역학 모델의 개발 (Development of Ship Dynamics Model by Free-Running Model Tests and Regression)

  • 김기원;김호용;최성은;나기인;이혁;서정화
    • 대한조선학회논문집
    • /
    • 제59권3호
    • /
    • pp.173-182
    • /
    • 2022
  • The present study suggests a procedure of establishing a ship dynamics modeling by regression of free-running model test results. The hydrodynamic force and moment of the whole model ship is derived from the low-pass filtered acceleration in the turning circle and zigzag maneuver tests. Force and moment of the propeller and rudder are separated from that of the whole ship to acquire the hull force and moment terms, based on the principles of the component model. The low-pass filter frequency is verified in prior to dynamics modeling, to find the threshold frequency of 2.5 Hz. The dynamics modeling of the hull is compared with the component modeling by captive model tests. Because of strong correlation between sway velocity, yaw angular velocity, and heel angle, each maneuvering coefficient is not able to be validated, but the whole modeling shows good agreement with the captive model tests.

인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성 (Accuracy of the healing abutment and impression coping combined system on implant impression)

  • 전경배;이두형;김정한;황준호;박현위;이규복
    • 대한치과보철학회지
    • /
    • 제53권2호
    • /
    • pp.105-110
    • /
    • 2015
  • 목적: 새롭게 개발된 인상채득이 가능한 치유지대주를 이용한 인상채득과 기존의 임프레션 코핑을 이용한 인상채득을 3차원적으로 비교함으로써 개발된 시스템의 정확성을 평가하였다. 재료 및 방법: 10명의 환자에서 구치부에 임플란트(SuperLine; Dentium, Seoul, Korea)를 식립 후 치유지대주(MyHealing; Raphabio Co., Seoul, Korea)를 연결하였다. 식립 3개월 후 보철물 제작을 위한 인상채득시 인상채득이 가능한 치유지대주를 이용한 transfer 방식과 기존의 인상용 코핑을 이용한 pick-up 방식으로 두 번 인상채득 후 각각 주모형을 제작하였다. 맞춤형 보철 지대주(Myplant; Raphabio Co., Seoul, Korea)를 제작하고 각각의 주모형에 체결 후 치과용 스캐너(Scanner S600; Zirkonzahn, South Tyrol, Italy)로 가상의 모형을 형성하였다. 3차원 분석 프로그램(Geomagic Qualify 12; Geomagic, Morrisville, NC, USA)을 이용하여 두 개의 가상의 모형을 중첩하여 지대주의 위치와 기울기의 차이를 분석하였다. 측정값은 Kruskal Wallis과 Mann-Whitney U test 방법을 통해 분석하였고, 유의수준은 0.05 로 설정하였다. 결과: 두 가지 인상법에 따른 지대주의 위치는 근원심 방향에서 0.032 mm, 협설측 방향에서 0.029 mm, 상하 방향에서 0.023 mm의 차이를 보였다. 기울기는 근원심 방향에서 $0.755^{\circ}$, 협설측 방향에서 $1.275^{\circ}$, 상하 방향에서 $0.420^{\circ}$의 차이를 보였다. 결론: 인상채득이 가능한 치유지대주를 이용한 인상채득 방식은 기존의 전통적인 인상용 코핑을 이용한 방식과 비교 시 0.032 mm 이내의 차이를 보였고 기존 논문과의 비교 시 유사한 수치이다.

경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구 (Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model)

  • 이혁재;김창회;임영준;김명주
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.201-208
    • /
    • 2008
  • 연구목적: 시멘트 유지형 지대주를 인상용 코핑으로 이용하고 레진이나 금속 구조물에 접착하여 스플린팅하는 새로운 인상법을 시도하였다. 연구의 목적은 첫 번째, 3개의 임플랜트가 $15^{\circ}$ 경사지게 식립된 모형에서 closed tray 인상법과 레진 스플린팅한 open tray 인상법의 정확성을 비교하는 것이고 두 번째, 새로운 인상법의 정확성을 앞의 두 가지 인상법과 비교하는 것이다. 연구 재료 및 방법: 3개의 임플랜트 아날로그가 선상으로 배열되고 가운데 아날로그는 모형에 수직이고 양쪽 끝 아날로그는 이것에 앞뒤로 $15^{\circ}$ 경사지게 배열된 주모형과 주모형에 잘 적합되는 기준구조물을 제작하였다. closed tray 인상법, 레진 스플린팅한 open tray 인상법, 지대주-레진구조물 접착 인상법, 지대주-금속구조물 접착 인상법, 각 10개씩 40번의 인상을 채득하여 복제모형을 제작하였다. 이미지 처리할 수 있는 광학 현미경을 이용하여 기준구조물과 복제모형내의 아날로그와의 수직간격을 측정하여 인상의 정확성을 평가하였다. 통계처리는 one-way ANOVA와 사후 검정으로 Tukey test를 5% 유의수준으로 시행하였다. 결과: closed tray 인상법;74.3 (${\pm}33.4$)${\mu}m$의 간격은 레진 스플린팅한 open tray 인상법과 다른 두 가지 새로운 인상법보다 간격의 크기가 통계적 유의성 있게 컸다(P<.05). 지대주-금속구조물 접착 인상법;42.5 (${\pm}11.9$)${\mu}m$은 다른 인상법들 보다 간격의 크기가 통계적 유의성 있게 작았다(P<.05). 지대주-레진구조물 접착 인상법;51.0 (${\pm}14.1$)${\mu}m$은 레진 스플린팅한 open tray 인상법50.3 (${\pm}16.9$)${\mu}m$과 통계적 유의성 있는 차이를 보이지 않았다(P>.05). 결론: 이 연구의 한계 내에서, 레진 스플린팅한 open tray 인상법은 closed tray 인상법보다 우수한 정확성을 나타내었고, 지대주를 금속구조물에 접착하는 새로운 인상법의 정확성은 레진 스플린팅한 open tray 인상법보다 우수하였다.

Double Scanning에 의한 고성능 중합체를 이용한 임플란트 지지 고정성 보철물 수복 증례 (Implant supported prosthesis with high performance polymers using a double scanning method)

  • 강경환;박진홍;이정열;신상완
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.305-310
    • /
    • 2017
  • 최근, CAD/CAM 기술이 발전하면서 하이브리드 보철물의 제작에 이용되고 있다. Double scanning technique은 시적용 납의치와 주모형을 스캔 후 중첩하여, 가상 디자인의 현실화와 보철 기공 과정의 간소화를 이루었다. 본 증례에서는 금속 혹은 지르코니아 대신 고성능 중합체인 Polyetherketoneketone (Pekkton, Cendres+$M{\acute{e}}taux$, Biel, Switzerland)를 framework의 재료로 사용했으며, 콤포짓이나 세라믹 혹은 의치용 치아 대신 Polymethyl methacrylate (PMMA) 비니어링 치아(Visio-lign, Bredent, Senden, Germany)를 최종 보철물로 사용하였다. Pekkton과 Visio-lign을 사용한 본 증례에서 만족할만한 치료 결과와 환자의 만족을 얻었으며, 추후 주기적인 유지관리 및 평가가 필요할 것으로 사료된다.

인상채득방법이 임플란트 주모형의 정확성에 미치는 영향 (EFFECT OF IMPRESSION TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS)

  • 김영오;양홍서
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.238-247
    • /
    • 2004
  • Statement of problem: Major objective in making on implant-supported prosthesis is the production of superstructure that exhibits a passive fit when connected to multiple abutments. One requirement to ensure passive fit is to make an accurate impression. Purpose : The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on fxiture level (Group FIX-D), 2) indirect method on fixture level(Group FIX-I), 3) modified indirect method on fixture level(Group FIX-M), 4) direct method on abutment level(Group AB-D) and 5) indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^{(R)}$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results : The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2. In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error. Conclusion: An impression method have more effect on accuracy of master model than an impression level. A modified indirect method showed smallest vertical and horizontal error.

어린이에게 사용되는 가철식 교정장치용 clasp의 유지력비교 (RETENTIVE FORCES OF CLASPS OF REMOVABLE ORTHODONTIC APPLIANCES FOR CHILDREN)

  • 한정재;이광희;김대업
    • 대한소아치과학회지
    • /
    • 제26권2호
    • /
    • pp.207-217
    • /
    • 1999
  • 본 연구의 목적은 어린이에게 사용되고 있는 가철식 교정장치를 위한 clasp에 대하여 각 디자인간 유지력의 차이를 평가하고자 함이다. 상악 유견치와 제 1, 2유구치 및 제 1 대구치를 단일 치아모형과 두 개의 인접 치아 형태로 금속 주모형을 제작한 후 clasp를 종류에 따라 형성하여 각 모형에 대한 clasp의 유지력을 측정하였다. Clasp의 종류에 따른 유지력을 서로 비교하여 다음과 같은 결론을 얻었다. 1. 단일치아에서 유지력을 얻는 clasp중 Jackson clasp와 Adams clasp는 다른 clasp에 비하여 높은 유지력을 나타냈으며, C clasp는 가장 낮은 유지력을 나타냈다(p<0.05). 2. 두개 이상 치아의 치간부 undercut을 이용하는 clasp중 eyelet clasp가 가장 큰 유지력을 보여주었고 triangular clasp, ball clasp순으로 낮은 유지력을 보여주었다(p<0.05).

  • PDF

치과 임플랜트 인상채득 방법에 따른 주모형의 정확성에 대한 비교 연구 (A COMPARATIVE STUDY ON THE ACCURACY OF MASTER CASTS BY IMPLANT IMPRESSION TECHNIQUES)

  • 류석민;조인호;임헌송;임주환
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.18-29
    • /
    • 2002
  • As the inaccuracy which was made in implant impression prevented passive fit, it needed to solder the sectioned framework at several locations to correct the inaccuracy. Many clinicians have suggested impression techniques which could make passive fit between implant and superstructure. The purpose of this research was to measure and compare the accuracy of three methods of taking impression with the strain amplifier. The experimental groups were classified as follows : Group I : splinted the two parts with $Futar^{(R)}D$ Occlusion. Group II : splinted the two parts with $DuraLay^{(R)}$. Group III ; didn't splint the two parts. The results were as follows ; 1. The values of strain in the vertical and horizontal surfaces were increased in the order of group I, group II and group III. 2. Group 1 showed higher accuracy of the duplicated casts in the vortical and horizontal sur faces than group II and group III (p<0.05). 3. There were no significant differences in the accuracy of the duplicated casts between group II and group III. From the above results, it is considered that the splinting method of impression copings could make an influence on the accuracy of the master casts. To improve the accuracy of the master casts, splinting the squared impression copings with the additional silicone occlusion materials is recommendable.

비심미적인 상악 전치부 치아 비율을 가지는 환자에서 치은 절제술을 동반한 전치부 심미수복 증례 (Anterior esthetic restoration accompanied by gingivectomy of patient with unesthetic tooth proportion of maxillary anterior teeth: a case report)

  • 한상연;이종혁;최석연
    • 구강회복응용과학지
    • /
    • 제34권3호
    • /
    • pp.208-217
    • /
    • 2018
  • 상악 전치부는 심미적으로 민감한 부위이며, 치아 외형과 치은의 조화도 치료의 성공과 밀접한 관련이 있다. 이를 위해서는 정확한 진단과 치료계획이 필수적이며, 필요 시 치아 주위 연조직에 대한 처치 등이 동반될 수 있다. 연조직 처치로서 외과적 치관연장술 중 하나인 치은절제술을 고려할 수 있으며 이를 통해 심미적인 보철 수복을 할 수 있다. 상악 전치부는 심미뿐 아니라 기능 또한 고려하여야 한다. 지대치 주모형과 순측만을 수정한 진단 납형 모형을 스캔 및 중첩하여 디자인 및 가공하면, 최소한의 교합조정을 통해 기존의 편안했던 교합을 재현해 줄 수 있다. 본 증례에서는 치은절제술 및 모형 중첩을 통해 심미 수복을 진행하였고, 그 결과 심미와 기능모두에서 환자의 만족도를 높였기에 이를 보고하는 바이다.

심한 골 흡수와 2급 악간관계를 보이는 완전 무치악 환자의 Piezography를 이용한 총의치 수복 (Complete denture rehabilitation of fully edentulous patient with severe bone resorption and class II jaw relation using piezography)

  • 권우일;송영균;이준석
    • 대한치과보철학회지
    • /
    • 제54권4호
    • /
    • pp.445-450
    • /
    • 2016
  • Piezography는 발음을 이용하여 채득된 보철 공간을 의미하며, 의치의 인공치와 연마면의 위치를 결정하는 참고점으로 사용하게 된다. 본 증례 대상은 67세 여성환자로, 새 의치 제작을 주소로 내원하였다. 기존 의치에서 2급 악간관계와 불량한 유지력을 확인할 수 있었으며, 안정적인 의치를 위해 piezography와 설측교합을 이용하기로 하였다. 통상적인 방법으로 인상 채득 후 주모형 상에서 상하악 기초상과 왁스 교합제를 제작하였고, 별도로 piezography를 위하여 하악에 추가적인 기초상을 하나 더 제작하였다. 이 추가 기초상에 실리콘 인상재를 적용 한 뒤 '시', '소', '메', '테', '데', '무' 여섯개의 발음으로 piezography를 채득하였다. 하악 인공치를 이 보철공간에 맞추어 배열한 뒤, 형태를 수정하여 설측 교합을 부여하였다. 그 결과, 환자는 새로운 의치에 기능적, 심미적으로 만족하였다.

인상채득법이 임플랜트 주모형의 정확성에 미치는 영향 (EFFECT OF IMPRESS10N TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS)

  • 김영오;양홍서;방몽숙;박상원;박하옥;이재봉
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.63-72
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and Method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on future level (Group FIX-D), 2) Indirect method on fixture level(Group FIX-I), 3) Modified indirect method on fixture level(Group FD(-M), 4) Direct method on abutment level(Group AB-D) and 5) Indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^(R)$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results: The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2 In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error.