• Title/Summary/Keyword: 좌측연결로

Search Result 66, Processing Time 0.027 seconds

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber

Stress distribution in bone surrounding maxillary molar implants under different crown-to-fixture ratio: A 3D FEM analysis (치관/고정체 비에 따른 상악 구치부 임플란트 주변골의 응력 분포에 대한 3차원 유한요소법적 분석)

  • Park, Jong-Chan;Shin, Sang-Wan;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.479-489
    • /
    • 2008
  • Statement of the problem: Under anatomical limitations on maxillary posterior region, a poor crown-to root ratio acting on dental implants can result in undesirable stress in surrounding bone, which in turn can cause bone defects and eventual failure of implants. Purpose: The purpose is to compare stress distribution due to different crown-root ratio and effect of splinting between natural teeth and implants in maxillary molar area under different loads. Material and methods: Analysis of stress arising supporting bone of the natural teeth and the implant was made with 3-dimensional finite element method. The model simulated naturel teeth was made with 2nd premolar and 1st molar in the maxillary molar region (Model T). The model simulated implants placed on same positions with two parallel implants of Straumann Dental Implant cemented abutment (Model I). Each model was designed in different crown-root ratio (0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it non-splinted or splinted. After that, 300 N force was loaded to each model in five ways (Load 1: middle of occlusal table, Load 2: middle of buccal cusp, Load 3: middle of lingual cusp, Load 4: horizontal load to buccal cusp of anterior abutment only, Load 5: horizontal load to middle of buccal cusp of each abutment), and stress distribution was analyzed. Results and conclusion: On all occasions, stress was concentrated at the cervical region of the implant. Under load 1, 2 and 3, stress was not increased even when crown-root ratio increases, but under load 4 and 5, when crown-root ratio increases, stress also increased. There was difference in stress values between natural teeth and implants when crown-root ratio gradually increases; In case of natural teeth, splinting decreased stress under vertical and horizontal loads. In case of implants, splinting decreased stress under vertical loads 1,2 and 3, but increased maximal stress under loads 2 and 3. Under horizontal loads, splinting decreased stress, however the effect of splinting decreased under load 5 than load 4. Furthermore, the stress was increased, when crown-root ratio is 1.25:1. Clinical implications: This limited finite element study suggests that the stress on supporting bone may be increased under non-axial loads and poor crown-root ratio. Under poor crown-root ratio, excessive stress was generated at the cervical region of the implant, and decreased splinting effect for stress distribution, which can be related to clinical failure.

Modified Blalock-Taussig Shunt in Neonates (신생아에서 변형 Blalock-Taussig 단락술)

  • 조광조;성시찬
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.378-382
    • /
    • 1997
  • To evaulate the effectiveness and risk factors for shunt failure of the Blalock-Taussig shunt in neonates, we analyzed the 21 neonates who were undergone Blalok-Taussig shunt operation at Dong-A University Hospital from December 1991 to Feburary 1996. We evaluated operative mortality, patency of the shunt. and distortion of pulmonary artery. We also determined the risk factors for the shunt failure. Age at operation was from 1 day to 30 days(mean 11.7 days). We ghts were 2.4 to 4.5kg(mean 3.1 kg). The underlying lesions included severe tetralogy of Fallot with pulmonary stenosls or atresia(N=11) and single ventricle varieties with. pulmonary stenosis or atresia(N=10). Prostaglandin El was given in 13 neonates prior to operation. The mean preoperative(prior to prostaglandin El therapy) and postoperative arterial oxygen tension were 30.1 mmHg and 46.3 mmHg respectively(P(0.01). The shunt was performed through a left thoracotomy in 11 patients and through a right thoracotomy In 10. A 5 mm graft was used in 15 patients and a 4 mm graft in 6 patients. The incidence of early shunt occlusion was 9.5%(2 patients). The hospital mortality was 9.5%(2 patients with early shunt occlusion). Univariate analysis revealed that body weight of 2.6 kg or less(p=0.021), pulmonary artery size of 3mm or less(p=0.008), and 4 mm graft (p=0.021) were risk factors predictive of early shunt failure. The patency rate of the shunt in hospital survivors was 100% at mean ollow-up of ll.3 months(There was not death or reoperation related to shunt failure). 10 patients were catheterized during postoperative follow-up. There was no significant distorsion of pulmonary artery. So we concluded that the modified Blalock-Taussig shunt in neonates was excellent in the hospital survivors.

  • PDF

Total Arterial Revascularization Using Y-composite Graft for Isolated Left Main Coronary Artery Disease (단독 좌주간 관동맥 협착병변에서 Y-도관을 이용한 완전 동맥도관 관상동맥우회로 조성술)

  • Ahn, Byong-Hee;Yu, Ung;Chun, Joon-Kyung;Ryu, Sang-Wan;Choi, Yong-Sun;Kim, Byong-Pyo;Hong, Sung-Bum;Bum, Min-Sun;Na, Kook-Ju;Jung, Myung-Ho;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.35-42
    • /
    • 2004
  • Background: For the treatment of isolated left main coronary artery disease, twelve arterial revascularizations with Y-composite grafts using left internal thoracic artery and radial artery or right gastroepiploic artery were peformed. This study was performed to investigate whether V-composite graft can satisfy the blood flow required to make myocardium act properly or not. Borderline stenotic lesions on the left main coronary artery, which are very prone to remodel the bypassed vessels due to competitive flows, were also considered. Material and Method: Among 247 patients who underwent coronary artery bypass grafting from March 2000 to April 2003, 12 patients (4.7%) who had received total arterial revascularizations for the isolated left main coronary artery disease were studied retrospectively. Result: left anterior descending arteries were bypassed with left internal thoracic artery by off-pump technique in all patients, however, 2 cases of left obtuse marginal branches were bypassed under on-pump beating heart. Except for one patient, who did not have an obtuse marginal branch more than 1 mm in diameter, 11 patients had gone through complete arterial revascularizations by use of the Y shape arterial graft. Among five patients who had less than 75% stenosis, one patient showed string sign on left internal thoracic artery grafted to left anterior descending artery. However, two grafts to obtuse marginal blanches were completely obstructed and one showed slender sign. There were no graft-dominant flow in patients with stenotic lesion less than 75%. On the contrary to the result of patients with stenotic lesions less than 75%, all the patients with stenotic lesions more than 90% showed graft-dominant blood flow. Conclusion: In conclusion, it is assumed that, when stenotic lesions are over 90%, coronary artery bypass grafting with an Y shape arterial graft could possibly give enough help to the obstructed coronary arteries in blood supplying to myocardium, which needs massive quantity of blood to act well. However, when patients have borderline stenoses, through scrupulous examinations, more prudent and flexible decisions are required in choosing the treatment methods, such as, direct anastomosis of vein or artery to aorta, or adding supplementary treatment methods like percutaneous coronary intervention, rather than choosing a fixed treatment methods.

Aortopulmonary Window (대동맥폐동맥창)

  • Kim Dong-Jin;Min Sun-Kyung;Kim Woong-Han;Lee Jeong-Sang;Kim Yong-Jin;Lee Jeong-Ryul
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.275-280
    • /
    • 2006
  • Background: Aortopulmonary window (APW) is a very rare congenital heart anomaly, often associated with other cardiac anomalies. It causes a significant systemic to pulmonary artery shunt, which requires early surgical correction. Accurate diagnosis and surgical correction will bring good outcomes. The purpose of this study was to describe our 20-year experience of aortopulmonary window. Material and Method: Between March 1985 and January 2005, 16 patients with APW underwent surgical repair. Mean age at operation was $157.8{\pm}245.3$ ($15.0{\sim}994.0$) days and mean weight was $4.8{\pm}2.5$ ($1.7{\sim}10.7$) kg. Patent ductus arteriosus (8), atrial septal defect (7), interruptedaortic arch (5), ventricular septal defect (4), patent foramen ovate (3), tricuspid valve regurgitation (3), mitral valve regurgitation (2), aortic valve regurgitation (1), coarctation of aorta (1), left superior vena cavae (1), and dextrocardia (1) were associated. Repair methods included 1) division of the APW with primary closure or patch closure of aorta and pulmonary artery primary closure or patch closure (11) and 2) intra-arterial patch closure (3). 3) Division of the window and descending aorta to APW anastomosis (2) in the patients with interrupted aortic arch or coarctation. Result: There was one death. The patient had 2.5 cm long severe tracheal stenosis from carina with tracheal bronchus supplying right upper lobe. The patient died at 5th post operative day due to massive tracheal bleeding. Patients with complex aortopulmonary window had longer intensive care unit and hospital stay and showed more morbidities and higher reoperation rates. 5 patients had reoperations due to left pulmonary artery stenosis (4), right pulmonary artery stenosis (2), and main pulmonary artery stenosis (1). The mean follow-up period was $6.8{\pm}5.6$ (57.0 days$\sim$16.7 years)years and all patients belonged to NYHA class 1. Conclusion: With early and prompt correction of APW, excellent surgical outcome can be expected. However, optimal surgical method needs to be established to decrease the rate of stenosis of pulmonary arteries.

Mitral Valve Repair for Mitral Regurgitation in Pediatric Patients (승모판폐쇄부전증를 가진 소아 환자에서 승모판성형술의 임상적 고찰)

  • Sim, Hyung-Tae;Yun, Tae-Jin;Park, Jeong-Jun;Jung, Sung-Ho;Uhm, Ju-Yeon;Jhang, Won-Kyoung;Kim, Young-Hwue;Ko, Jae-Kon;Park, In-Sook;Seo, Dong-Man
    • Journal of Chest Surgery
    • /
    • v.40 no.8
    • /
    • pp.536-545
    • /
    • 2007
  • Background: Compared to adult patients, mitral regurgitation in pediatric patients is uncommon and it shows a wide spectrum of morphologic abnormalities. We retrospectively evaluated the midterm results of mitral valve repair in pediatric patients. Material and Method: Between December 1993 and August 2006, mitral valve repair was performed in 35 patients who were aged less than 18 years, The mean age was $5.3{\pm}5.3$ years and the mean body weight was $20,0{\pm}16.3\;kg$. 18 patients had associated cardiac anomalies. The most common pathologic finding was leaflet prolapse (n=17). The most common method of repair was the double orifice technique (n=15). Result: There was no early mortality. Eight patients underwent reoperation (24.2%), and five of them required mitral valve replacement. Among the four ring annuloplasty cases, two have developed mitral stenosis. Four out of the 14 double orifice cases required reoperation. One case of early mortality and one case of late mortality occurred in the reoperation cases. The 5-year survival rate and the freedom from reoperation rate were $93.3{\pm}4.6%$ and $76.1{\pm}8.2%$, respectively. The 5-year freedom from mitral valve replacement rate was $83.6{\pm}6.7%$. There was no significant risk factor for reoperation. Conclusion: The midterm results of mitral valve repair are very acceptable in pediatric patients compared to the adult cases, although the reoperation rate is slightly higher.