• Title/Summary/Keyword: 종합법

Search Result 1,648, Processing Time 0.027 seconds

Hydraulic Characteristics of Busan Clay in the Floodplain of the Nakdong River Delta (낙동강 삼각주 범람원에서 부산점토의 수리학적 특성)

  • Chung, Seong-Gyo;Lee, Nam-Ki;Lee, Jeong-Man;Min, Se-Chan;Hong, Yang-Pyo
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.11
    • /
    • pp.47-61
    • /
    • 2010
  • To predict the settlement rate of a ground area that incorporates vertical drains, it is desirable to conduct various kinds of advanced field and laboratory tests for hydraulic properties. However, it is urgently needed to appropriately evaluate the hydraulic properties using the results of conventional soil tests which are extensively used for local practice. To achieve this purpose, a number of CPT dissipation test, laboratory permeability and consolidation tests were performed at five sites in the floodplain of the Nakdong River delta, and the test data were comprehensively analyzed. As a result, it is found that the coefficients of horizontal consolidation ($C_{h,NC}$) and permeability ($k_{h,OC}$) of the clay agreed well with those of the CPT-based methods proposed by Baligh and Levadoux (1986). The values of $C_{h,NC}$ and $k_{h,OC}$ were in the range of $0.4{\sim}3.0\;cm^2/sec$ and $0.40{\sim}2.50\;cm^2/sec$, each of which slightly increases or decreases with depth, respectively. It was also inferred that these trends seem to reflect the depositional environments of the clay.

Influence of Pile Driving-Induced Vibration on the Adjacent Slope (파일 항타진동이 인접 비탈면에 미치는 영향)

  • Kwak, Chang-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.5
    • /
    • pp.27-40
    • /
    • 2023
  • A pile is a structural element that is used to transfer external loads from superstructures and has been widely utilized in construction fields all over the world. The method of installing a pile into the ground should be selected based on geotechnical conditions, location, site status, environmental factors, and construction costs, among others. It can be divided into two types: direct hammering and preboring. The direct hammering method installs a pile into the bearing layer, such as rock, using a few types of hammer, generating a considerable amount of pile driving-induced vibration. The vibration from pile driving influences adjacent structures and the ground; therefore, quantitatively investigating the effects of vibration is inevitably required. In this study, two-dimensional dynamic numerical modeling and analysis are performed using the finite difference method to investigate the influence on the adjacent slope, including temporary supporting system. Time-dependent loading induced by pile driving is estimated and used in the numerical analysis. Consequently, large surface displacement is estimated due to surface waves and less wave deflection, and refraction at the surface. The total displacement decreases with the increase of the distance from the source. However, lateral displacement at the top of the slope shows a larger value than vertical displacement, and the overall displacement tends to be concentrated near the face of the slope.

A SVR Based-Pseudo Modified Einstein Procedure Incorporating H-ADCP Model for Real-Time Total Sediment Discharge Monitoring (실시간 총유사량 모니터링을 위한 H-ADCP 연계 수정 아인슈타인 방법의 의사 SVR 모형)

  • Noh, Hyoseob;Son, Geunsoo;Kim, Dongsu;Park, Yong Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.321-335
    • /
    • 2023
  • Monitoring sediment loads in natural rivers is the key process in river engineering, but it is costly and dangerous. In practice, suspended loads are directly measured, and total loads, which is a summation of suspended loads and bed loads, are estimated. This study proposes a real-time sediment discharge monitoring system using the horizontal acoustic Doppler current profiler (H-ADCP) and support vector regression (SVR). The proposed system is comprised of the SVR model for suspended sediment concentration (SVR-SSC) and for total loads (SVR-QTL), respectively. SVR-SSC estimates SSC and SVR-QTL mimics the modified Einstein procedure. The grid search with K-fold cross validation (Grid-CV) and the recursive feature elimination (RFE) were employed to determine SVR's hyperparameters and input variables. The two SVR models showed reasonable cross-validation scores (R2) with 0.885 (SVR-SSC) and 0.860 (SVR-QTL). During the time-series sediment load monitoring period, we successfully detected various sediment transport phenomena in natural streams, such as hysteresis loops and sensitive sediment fluctuations. The newly proposed sediment monitoring system depends only on the gauged features by H-ADCP without additional assumptions in hydraulic variables (e.g., friction slope and suspended sediment size distribution). This method can be applied to any ADCP-installed discharge monitoring station economically and is expected to enhance temporal resolution in sediment monitoring.

Experiments on Avoiding and Deodorizing and Antibacterial of Haemaphysalis longicornis (Ixodoidea: Ixodidae) of Complex Extracts Including Water-Soluble Phytoncide (수용성 피톤치드(water-soluble phytoncide)를 포함한 복합추출물의 작은소피참진드기(Haemaphysalis longicorins) 기피와 탈취 및 항균 실험)

  • Seul Gi Kwon;Hyo Jung Jung;Jun Young Jung; and Jae Hwa Lee
    • Korean journal of applied entomology
    • /
    • v.62 no.2
    • /
    • pp.95-102
    • /
    • 2023
  • The number of households with pets has increased in recent years. Consequently, interest in mites and their odors has increased. In this study, we investigated whether pyrethrum extract and water-soluble phytoncides are effective tick repellents, deodorizing agents, and antibacterial agents. In the tick-climbing test, the pyrethrum extract (23.33 points) and water-soluble phytoncide (22.00 points) showed a high repelling effect. To confirm the tick avoidance effect of the composite extract, a tick climbing test was conducted with a pest control extract, a composite extract (referred to as a sample) containing a water-soluble phytoncide, and a third-party product (control). The sample showed a high avoidance effect (13.00 points and Control 26.67 points. An indoor repellent efficacy test for ticks confirmed that the sample showed an excellent tick-repellent effect (88%) compared to the control (12%). As a result of a deodorization test, ammonia was shown to have a deodorizing effect of 98.3% and trimethylamine of 99.5%, whereas, in the antibacterial test, the E. coli, Staphylococcus aureus, and pneumonia groups showed an antibacterial effect of 99.9%. Combining the results of this study, it is judged that the complex extract including the above material has high utility value as a material that is effective in mite repellents, deodorization, and antibacterial activity.

Study on Wearable Health Care Devices Function Using Quantified Self - Focusing on Cardio-cerebrovascular Disease - (수치화 된 자아를 활용한 헬스케어 웨어러블 디바이스 기능 분석 - 심뇌혈관 질환 중심으로 -)

  • Lee, Ye Rim;Jung, Jung Ho
    • Design Convergence Study
    • /
    • v.16 no.5
    • /
    • pp.1-20
    • /
    • 2017
  • Cardio-cerebrovascular disease is one of the chronic diseases that often attack people in Korea, and in fact, it ranks second in terms of death rate. This disease can be prevented by improving lifestyle, usual health care is important. But, in Korea most of the prevention or management programs adopt passive methods like using guide books or giving lectures, so it is not very effective in preventing the disease. Presently, the smart health care market is being developed in Korea and overseas. As an example, quantified self is being spread through wearable devices which are intended to measure each individual's health conditions and quantify body data into numbers for bettering habits. Accordingly, this author will explore and discuss wearable health care devices so as to prevent and manage cardio-cerebrovascular disease in a more active way. First, this study has classified wearable health care devices presently commercialized or related with cardio-cerebrovascular disease into wrist, clothes, or attaching types by the way of their attachment and analyzed them. After that, summing that up, this author performed cross-tabulations with other ways of preventing cardio-cerebrovascular disease. This will contribute to improving one's health care behavior about disease more actively and also work as an active interdisciplinary mechanism in research dealing with how to prevent disease afterwards.

The Effective for Non-Point pollution Reduction Facility installation project (비점오염저감시설 설치사업의 효과 평가)

  • Choe, Hye-Seon;Geronimo, Franz Kevin;Jeon, Min-Su;Reyes, Nash Jett;Kim, Lee-Hyeong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.206-206
    • /
    • 2020
  • 토지이용의 고도화에 따라 비점오염원 부하는 증가하는 추세이며 기후변화에 따른 강우강도 증가 등으로 지표면에 축적된 고농도의 비점오염물질이 하천으로 유출, 수질오염을 가중시키고 있어 비점오염원 관리가 필요하다. 환경부에서 효율적인 비점오염원 관리를 위하여 2004년부터 현재까지 3단계에 걸쳐 비점오염원 관리 종합대책을 수행하고 있으며, 2008년부터 비점국고보조사업을 추진하여 비점오염저감시설 설치를 통한 수질개선 및 수생태계 건강성 확보에 기여하고자 하였다. 이에 본 연구는 비점국고보고사업을 통해 구축된 비점오염저감시설을 대상으로 시설 설치 및 운영 현황과 강우시 비점오염저감 효과 분석을 통한 시설의 평가를 수행하고자 한다. 연구대상시설은 시범시설 및 국고보조시설 총 70개소로 2005~2017년에 준공되었으며, 2016년부터 현재까지 총 4년동안 진행된 모니터링을 바탕으로 연구를 수행하였다. 시설의 용량은 34~97,000㎥의 범위로 SA/CA 1.2~6.6%의 범위이다. 강우시 모니터링은 선행무강우일수 3일이상을 고려하여 수행하였으며 도시지역의 경우 5mm 이상, 농촌지역 10mm 이상시 모니터링을 진행하였다. 시설의 유입과 유출부에서 수질 및 유량 모니터링을 진행하였으며, 수질오염공정시험법에 준하여 BOD, COD, SS, T-N 및 T-P 항목에 대해 분석을 수행하였다. 모니터링 결과, 국내 비점오염저감시설의 평균 부하량은 SS 250.4 kg/day, BOD 89.2 kg/day, COD 136.2 kg/day, TN 51.4 kg/day, TP 7.1 kg/day 로 분석되었으며, 유출부 의 경우 SS 83.8 kg/day, BOD 37.2 kg/day, COD 51.0 kg/day, TN 15.4 kg/day, TP 2.0 kg/day로 나타났다. 또한, 은 오염물질 유입 및 유출 부하량의 상관관계 분석결과 SS, BOD, COD의 유입 및 유출 부하량의 상관성은 높게 나타났으며 특히 유기물질(BOD, COD)의 상관성은 0.8이상으로 분석되었다(p<0.005). 이는 비점오염저감시설에 적용된 식생, 미생물, 여재 등을 통하여 물리학적 및 생태학적 처리를 통해 저감되기 때문으로 판단된다. 하지만, TN은 인위적 요인과 자연적 요인이 복합적으로 작용으로 배출 특성으로 상관성은 매우 낮은 것으로 분석되었다.

  • PDF

Study on the Applicability of CPT Based Soil Classification Chart (콘관입시험결과를 이용한 흙분류차트의 적용성에 관한 연구)

  • Kim, Chan-Hong;Im, Jong-Chul;Kim, Young-Sang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5C
    • /
    • pp.293-301
    • /
    • 2008
  • Soil profiling is one of the most important work among geotehnical engineering practice. Generally, soil profile is estimated from the observation of soil samples during subsurface exploration but such estimation also includes some experiencing aspects such as flushed water from the borehole, slime colour, boring speed and so on. In addition, since the capacity of hydraulic drill rig is significantly increased, thin layers might be easily missed. So, continuous soil profile is almost impossible over all depth to be bored from conventional subsurface exploration. While CPT or CPTu can serve continuous soil profile information over all depth generally in 5cm interval. Many charts or methods for soil profile from CPT result have been proposed during last several decades over the world. However they have not been verified in local ground condition in Korea. In this research, CPT results and soil classification results based on USCS were compiled from 17 sites over the Korea. Soil classification results by using 7 CPT soil classification charts were compared with those of USCS for the compiled database. Most proper CPT soil classification chart for Korean soil characteristics was evaluated and effective parameters for the soil classification from CPT were discussed. Finally interrelationship between CPT soil classification chart and USCS soil classification was evaluated.

Apportionment of Liquidated Damages and Compensation for Delay Damages in Domestic Construction Project : Analysis and Improvement (국내 현행 공기지연 책임에 따른 지체상금 및 손실보상의 문제점 및 개선방안)

  • Kim, Kyong Ju;Kim, Kyoungmin;Kim, Jong Inn;Wei, Ameng;Kim, Eu Wang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.1
    • /
    • pp.12-20
    • /
    • 2023
  • To calculate the amount of owner-caused and contractor-caused delays based on a simplified delay analysis, which has been customarily used in Korea, has a limitation in reflecting the impact of the concurrent delay and the acceleration work. It also resulted in the apportionment of liquidated damages by applying the ratio of the number of delays between the owner and the contractor. This study analyzes that the conventional method does not meet the international standards. In order to improve the problem of construction delay analysis and the apportionment of liquidated damages based on it, owner delays, contractor delays, concurrent delays, and the impact of acceleration should be analyzed together. This study suggests that in the apportionment of liquidated damages, the extension of time should be extended by the sum of concurrent delays and the owner-caused delays, and liquidated damages should be imposed on delays incurred after the extension of time. It can be seen that it conforms to the international standards. The results of this study are expected to contribute to improving the problems of delay analysis and liquidated damages calculation, which have been conventionally accepted.

Ultraviolet Lamp Replacement Period and Hygiene Management Plan of Ultraviolet Sterilizer (자외선 살균고의 자외선 램프 교체 주기와 위생관리 방안)

  • Young-Ju Lee;Ju-Hyun Lee;Eun-Sol Go;Jung-Beom Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.1
    • /
    • pp.26-30
    • /
    • 2023
  • In this study, we analyzed the microbial contamination level of ultraviolet sterilizer (UVS) chambers and suggested plans to improve hygiene management. In this study, UVS chambers targeted 98 UVS in some childcare centers in Jeollanam-do, Korea. Total aerobic bacteria and coliform bacteria were tested according to the Korean Food Code. Of the 98 UVS chambers, total aerobic bacteria were detected in 67 (68.4%) and coliform bacteria in 5 (5.1%). Six kinds of food-poisoning bacteria, including Salmonella spp., were not detected, but Bacillus cereus was detected in 1 (2.8%) out of 98 UVS chambers. According to the UV lamp replacement period, the detection rate of total aerobic bacteria was 3 (50%) out of 6 UVS within 3 months, 3 (60%) out of 5 UVS in 3 to 6 months, and 61 (70.1%) out of 87 UVS over 6 months. The detection rate of coliform bacteria according to the UV lamp replacement period was not detected within 6 months, however, they were detected in 5 (5.7%) out of 87 chambers after more than 6 months. The level of microbial contamination in the UVS chambers was higher as the lamp replacement period was longer. Considering these results, it was determined that the UVS chambers should be kept dry and clean, and the UV lamp should be replaced periodically. In addition, it is necessary to provide the staff catering for childcare centers with continuous education regarding the cleaning of UVS chambers and the replacement of UV lamps.

Evaluation of the Nonlinearity Parameter in Unbound Material for Asphalt Concrete Pavement using Field-NDT Equipment (현장 도로평가장비를 이용한 입상재료층의 비선형 재료상수 추정에 관한 연구)

  • Seo, Joo Won;Choi, Jun Seong;Kim, Soo Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2D
    • /
    • pp.227-234
    • /
    • 2008
  • This study examines which models are more suitable for representing mechanical property of unbound materials to analyze behavior of asphalt pavement structure. Results from FWD (Falling Weight Deflectometer) test were used to apply to nonlinear elastic model. The new method which can deduct material constants of nonlinear elastic model is suggested from FWD test data rather than laboratory resilient modulus ($M_R$) test. It is confirmed that the material constants are within the common range in subbase. Test output from FWD and MDD (Multi-Depth Deflectometer) was used to verify reliability of the model. From the results of verification, this study shows that a non-linear elastic model agrees to MDD test data more than a linear elastic model does.