• Title/Summary/Keyword: 종양 추적

Search Result 715, Processing Time 0.023 seconds

Granular Cell Tumor of the Axillary Accessory Breast: A Case Report (액와부 부유방에 발생한 과립 세포 종양: 증례 보고)

  • Youn Joo Jung;Kyung Jin Nam;Ki Seok Choo;Kyeyoung Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.275-279
    • /
    • 2023
  • Granular cell tumors (GCTs) are rare benign soft tissue tumors that can occur throughout the body, particularly the head and neck; only 5%-8% of GCTs occur in the breast. We report a case of a GCT of the axillary accessory breast, which is a rare location of this tumor. A 50-year-old woman had a 2-month history of a palpable mass in the left axilla. Physical examination, as well as mammographic and ultrasonographic findings suggested a breast malignancy. Histopathological examination showed a benign GCT, and wide local excision was performed. The patient has remained disease-free over 2 years postoperatively. Although most GCTs are benign, wide complete resection of the tumor and follow-up are required considering the possibility of recurrence. The radiologist should know the characteristics of GCTs as a differential diagnosis of breast and axillary lesions to prevent unnecessary treatment.

Analysis of Dose Distribution on Critical Organs for Radiosurgery with CyberKnife Real-Time Tumor Tracking System (사이버나이프 실시간 종양추적 시스템을 이용한 방사선수술 시 주요 장기의 선량분포 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Ji, Young-Hoon;Kim, Kum-Bae;Lee, Sang-Hoon;Choi, Jin-Ho;Lee, Re-Na;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • We measured the dose distribution for spinal cord and tumor using Gafchromic film, applying 3D and 4D-Treatment Planning for lung tumor within the phantom. A measured dose distribution was compared with a calculated dose distribution generated from 3D radiation treatment planning and 4D radiation treatment planning system. The agreement of the dose distribution in tumor for 3D and 4D treatment planning was 90.6%, 97.64% using gamma index computed for a distance to agreement of 1 mm and a dose difference of 3%. However, a gamma agreement index of 3% dose difference tolerence of and 2 mm distance to agreement, the accordance of the dose distribution around cord for 3D and 4D radiation treatment planning was 57.13%, 90.4%. There are significant differences between a calculated dose and a measured dose for 3D radiation treatment planning, no significant differences for 4D treatment planning. The results provide the effectiveness of the 4D treatment planning as compared to 3D. We suggest that the 4-dimensional treatment planning should be considered in the case where such equipments as Cyberknife with the real time tracking system are used to treat the tumors in the moving organ.

  • PDF

Extragonadal Intraabdominal Mixed Germ Cell Tumor with Liver Metastasis: Successful Treatment and Long-term Follow-up (간 전이를 동반한 복강 내 성선 외 혼합 생식세포종양: 성공적인 치료 및 장기간 추적관찰)

  • Park, Jinyoung
    • Advances in pediatric surgery
    • /
    • v.19 no.1
    • /
    • pp.25-31
    • /
    • 2013
  • 성선 외 생식세포종양은 비교적 드물어 모든 생식세포종양의 5% 미만을 차지한다. 주로 천미부생식세포종양이 골반부나 후복막으로 확장된 경우가 대부분이며, 후복막이나 복강 내에 발생하는 생식세포종양은 매우 드물다. 저자는 복부 종괴를 주소로 내원한 18개월 된 여아에서 간 전이를 동반한 복강 내 혼합 생식세포종양을 치료하였다. 복부 초음파 및 전산화 단층촬영에서 복부 좌상사분역에 석회화, 고형 및 지방 성분을 포함하고 있는 낭성 종괴와 간에 1cm 크기의 결절이 관찰되었다. 종괴는 개복 후 제거되었으며, 병리조직학적으로 대부분의 내배엽동 종양과 적은 성숙 기형종으로 구성된 혼합 생식세포종양으로 진단되었으며, 간의 전이병변도 동일하게 진단되었다. 수술 후 항암화학요법을 시행하였으며, 환자는 현재 수술 후 10년이 경과하였으나 재발의 소견은 없다.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Benign Schwannoma of the Esophagus (식도에 생긴 양성 신경초종)

  • 신종목;김주현;성숙환;김영태
    • Journal of Chest Surgery
    • /
    • v.33 no.11
    • /
    • pp.922-924
    • /
    • 2000
  • 양성 신경초종(benign schwannoma)이 식도를 포함한 위장관계에 발생하는 경우는 매우 드물다. 이러한 양성식도 신경초종은 확진을 위해 면역 조직 화학적 염색을 필요로 한다. 정기 신체 검진상 우연히 발견된 66세여자 환자의 식도 점막하 종양에 대해 우측 후측부 개흉을 통한 종양 적출을 시행하였으며, 술후 면역 조직 화학적 병리 검사를 통하여 식도의 양성 신경초종임을 확인하였고, 환자는 술후 1년째 재발없이 외래 추적 관찰을 받고 있다.

  • PDF

Clinical Significance of Tumor Markers in Gastric Cancer Patients after Curative Resection (근치적 절제술을 시행한 위암 환자에서 종양 표지자의 임상적 의미)

  • Kim, Sa-Young;Ha, Tae-Kyung;Kwon, Sung-Joon
    • Journal of Gastric Cancer
    • /
    • v.9 no.3
    • /
    • pp.136-142
    • /
    • 2009
  • Purpose: This clinical study was conducted to evaluate the predictive value of tumor markers for recurrence and the clinical significance of false positive findings after curative gastrectomy in patients with gastric cancer. Materials and Methods: Two hundred ninety patients with gastric cancer who underwent gastrectomy with curative intent were evaluated retrospectively. We analyzed the correlations between changes in tumor markers (CEA, CA 19-9, AFP, and CA-125) and clinicopathologic data, and basis for changes in tumor markers without recurrence during the follow-up period. Results: The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of tumor markers for recurrence were 75.0%, 64.6%, 23.1%, 94.8%, and 65.9% respectively. Among 36 patients with recurrences, 10 patients (27.8%) had elevated tumor markers prior to positive findings on imaging studies, while 13 patients (36.1%) had concomitant elevation in tumor markers. At least 1 of the 4 tumor markers increased in 90 of 290 patients during the follow-up period; however, there was no evidence of tumor recurrence. Twenty patients had persistently elevated tumor markers, while the tumor marker levels in 70 patients returned to normal level within $9.08\pm7.2$ months. The patients with pulmonary disease, hepatobiliary disease, diabetes, hypertension, or herbal medication users had elevated tumor markers more frequently than patients without disease (P<0.001). Conclusion: Although detecting recurrence of gastric cancer with tumor markers may be useful, false positive findings of tumor markers are common, so surgeons should consider other chronic benign diseases and medical conditions when tumor markers increase without evidence of recurrence.

  • PDF

Comparison of Three- and Four-dimensional Robotic Radiotherapy Treatment Plans for Lung Cancers (폐암환자의 종양추적 정위방사선치료를 위한 삼차원 및 사차원 방사선치료계획의 비교)

  • Chai, Gyu-Young;Lim, Young-Kyung;Kang, Ki-Mun;Jeong, Bae-Gwon;Ha, In-Bong;Park, Kyung-Bum;Jung, Jin-Myung;Kim, Dong-Wook
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.238-248
    • /
    • 2010
  • Purpose: To compare the dose distributions between three-dimensional (3D) and four-dimensional (4D) radiation treatment plans calculated by Ray-tracing or the Monte Carlo algorithm, and to highlight the difference of dose calculation between two algorithms for lung heterogeneity correction in lung cancers. Materials and Methods: Prospectively gated 4D CTs in seven patients were obtained with a Brilliance CT64-Channel scanner along with a respiratory bellows gating device. After 4D treatment planning with the Ray Tracing algorithm in Multiplan 3.5.1, a CyberKnife stereotactic radiotherapy planning system, 3D Ray Tracing, 3D and 4D Monte Carlo dose calculations were performed under the same beam conditions (same number, directions, monitor units of beams). The 3D plan was performed in a primary CT image setting corresponding to middle phase expiration (50%). Relative dose coverage, D95 of gross tumor volume and planning target volume, maximum doses of tumor, and the spinal cord were compared for each plan, taking into consideration the tumor location. Results: According to the Monte Carlo calculations, mean tumor volume coverage of the 4D plans was 4.4% higher than the 3D plans when tumors were located in the lower lobes of the lung, but were 4.6% lower when tumors were located in the upper lobes of the lung. Similarly, the D95 of 4D plans was 4.8% higher than 3D plans when tumors were located in the lower lobes of lung, but was 1.7% lower when tumors were located in the upper lobes of lung. This tendency was also observed at the maximum dose of the spinal cord. Lastly, a 30% reduction in the PTV volume coverage was observed for the Monte Carlo calculation compared with the Ray-tracing calculation. Conclusion: 3D and 4D robotic radiotherapy treatment plans for lung cancers were compared according to a dosimetric viewpoint for a tumor and the spinal cord. The difference of tumor dose distributions between 3D and 4D treatment plans was only significant when large tumor movement and deformation was suspected. Therefore, 4D treatment planning is only necessary for large tumor motion and deformation. However, a Monte Carlo calculation is always necessary, independent of tumor motion in the lung.

A Fusion Study on the Selection of Cyberknife Technique according to the Location of the Pulmonary Tumors (폐종양의 위치에 따른 사이버나이프 기법의 선택에 관한 융합적 연구)

  • Kim, Gab-Jung;Kim, Jeong-Ho;Bae, Seok-Hwan;Kim, Nak-Sang;Seo, Sun-Yeol
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.7
    • /
    • pp.101-108
    • /
    • 2019
  • Depending on the location of the lung tumor, the choice of treatment technique should be considered when treating the Cyberknife. The 4DCT images of 18 lung cancer patients were analyzed, and location error values were extracted through application program. The evaluation result was lower than the average position error only in the upper and the inner. These results suggest that the Vertebral tracking technique is effective when it is close to the pulmonary attachment or near the vertebral body, and the Synchrony technique is effective at other positions. In the future, we would like to study cyber knife treatment technique according to the position of the tumor as well as the volume of the lung and the respiratory cycle.