Browse > Article
http://dx.doi.org/10.15207/JKCS.2019.10.7.101

A Fusion Study on the Selection of Cyberknife Technique according to the Location of the Pulmonary Tumors  

Kim, Gab-Jung (Division of Radiology, Songho University)
Kim, Jeong-Ho (Department of Radiation Oncology, Konyang University Hospital)
Bae, Seok-Hwan (Division of Radiological science, Konyang University)
Kim, Nak-Sang (Division of Radiology, Songho University)
Seo, Sun-Yeol (Department of Radiology, Daejeon Eulji Medical Center)
Publication Information
Journal of the Korea Convergence Society / v.10, no.7, 2019 , pp. 101-108 More about this Journal
Abstract
Depending on the location of the lung tumor, the choice of treatment technique should be considered when treating the Cyberknife. The 4DCT images of 18 lung cancer patients were analyzed, and location error values were extracted through application program. The evaluation result was lower than the average position error only in the upper and the inner. These results suggest that the Vertebral tracking technique is effective when it is close to the pulmonary attachment or near the vertebral body, and the Synchrony technique is effective at other positions. In the future, we would like to study cyber knife treatment technique according to the position of the tumor as well as the volume of the lung and the respiratory cycle.
Keywords
Cyberknife; Synchrony; Vertebral tracking; Pulmonary tumor; Position Delta Value;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Y. B. Kim & C. O. Suh. (2008). Evolution of Radiotherapy: High-precision Radiotherapy, Journal of the Korean Medical Association, 51(7), 604-611. DOI : 10.5124/jkma.2008.51.7.604   DOI
2 P. Giraud et al. (2011). Centers, Respiratory gating techniques for optimization of lung cancer radiotherapy, Journal of thoracic oncology, 6(12), 2058-2068. DOI : 10.1097/JTO.0b013e3182307ec2   DOI
3 T. Biswas et al. (2012). SU‐E‐T‐422: Lung SBRT Using Cyberknife: Technique and Treatment Outcome, Medical physics, 39(6Part16), 3801-3802. DOI : 10.1118/1.4735511   DOI
4 P. C. Gerszten et al. (2004). CyberKnife frameless stereotactic radiosurgery for spinal lesions: clinical experience in 125 cases, Neurosurgery, 55(1), 89-99. DOI : 10.1227/01.neu.0000440704.61013.34
5 S. Y. Seo, M. S. Han, C. G. Kim, M. C. Jeon, Y, K, Kim & G. J. Kim. (2017). A study on the usefulness of a fusion model designed cloak shield to reduce the radiation exposure of the assistant during CT of severely injured patient. Journal of the Korea Convergence Society, 8(9) 211-216. DOI : 10.15207/JKCS.2017.8.9.211   DOI
6 Y. J. Jeong & S. H. Kim. (2015). Useful evaluation of 3D target location correction by using Xsight spine tracking system in CyberKnife. Journal of Digital Convergence, 13(1), 331-339. DOI : 10.14400/JDC.2015.13.1.331   DOI
7 B. H. Han et al. (2014). Evaluation of the Reproducibility of Radiation Output from Diagnostic X-ray Equipment(Standards Based on IEC 60601-2-54). Journal of Digital Convergence, 12(2), 555-561. DOI : 10.14400/JDC.2014.12.2.555   DOI
8 K. Y. Lee, B. G. Jung, J. W. Kim, J. S. Park & B. H. Jeong, (2018). Simulation of the High Frequency Hyperthermia for Tumor Treatment. Journal of the Korea Convergence Society, 9(3), 257-263. DOI : 10.15207/JKCS.2018.9.3.257   DOI
9 T. R. Mackie et al. (2003). Image guidance for precise conformal radiotherapy, International Journal of Radiation Oncology* Biology* Physics, 56(1), 89-105. DOI : 10.1016/S0360-3016(03)00090-7   DOI
10 S. Webb. (1991). Optimization by simulated annealing of three-dimensional conformal treatment planning for radiation fields defined by a multileaf collimator, Physics in medicine and biology, 36(9), 1201. DOI : 10.1088/0031-9155/36/9/004   DOI
11 L. Leksell. (1983). Stereotactic radiosurgery, Journal of Neurology, Neurosurgery & Psychiatry, 46(9), 797-803. DOI : 10.1136/jnnp.46.9.797   DOI
12 J. Kim, M. Han, S. Yoo, K. Kim & J. H. Cho. (2015). Improvement of Beam-Quality Evaluation Method for Medical Linear Accelerator Using Magnetic Field, Journal of Magnetics, 20(2), 120-128. DOI : 10.4283/JMAG.2015.20.2.120   DOI
13 T. S. Suh & I. H. Kim. (2008). Physical and Biological Background of Radiosurgery, Journal of the Korean Medical Association, 51(1), 16-26. DOI : 10.5124/jkma.2008.51.1.16   DOI
14 K. H. Wong, S. Dieterich J. Tang & K. Cleary. (2007). Quantitative measurement of CyberKnife robotic arm steering, Technology in cancer research & treatment, 6(6), 589-594. DOI : 10.1177/153303460700600601   DOI
15 M. Sarfaraz. (2007). CyberKnife${(R)}$ robotic arm stereotactic radiosurgery, Journal of the American College of Radiology, 4(8), 563-565. DOI : 10.1016/j.jacr.2007.05.003   DOI
16 Y. S. Kim. (2008). Cyberknife Robotic Radiosurgery System for Cancer Treatment, Journal of the Korean Medical Association, 51(7), 630-637. DOI : 10.5124/jkma.2008.51.7.630   DOI
17 A. Schweikard, G. Glosser, M. Boddulur, M. J. Murphy & J. R. Adler. (2000). Robotic motion compensation for respiratory movement during radiosurgery, Computer Aided Surgery, 5(4), 263-277. DOI : 10.3109/10929080009148894   DOI
18 K. Kitamura et al. (2002). Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions, International Journal of Radiation Oncology* Biology* Physics, 53(5), 1117-1123. DOI : 10.1016/S0360-3016(02)02882-1   DOI
19 M. Hoogeman, J. B. Prevost, J. Nuyttens, J. Poll, P. Levendag & B. Heijmen. (2009). Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files, International Journal of Radiation Oncology* Biology* Physics, 74(1), 297-303. DOI : 10.1016/j.ijrobp.2008.12.041   DOI
20 W. Kilby, J. R. Dooley, G. Kuduvalli, S. Sayeh & C. R. Maurer Jr. (2010). The CyberKnife(R) robotic radiosurgery system in 2010, Technology in cancer research & treatment, 9(5), 433-452. DOI : 10.1177/153303461000900502   DOI
21 C. Ozhasoglu et al. (2008). Synchrony-cyberknife respiratory compensation technology, Medical Dosimetry, 33(2), 117-123. DOI : 10.1016/j.meddos.2008.02.004   DOI
22 R. Shirazi, P. M. Goldfarb, D. B. Fuller & H. Sanati. (2011). CyberKnife stereotactic body radiation therapy for palliation and local control in patients with advanced pancreatic cancer: A retrospective review, Journal of Clinical Oncology, 29(15_suppl), e14506-e14506. DOI : 10.1200/jco.2011.29.15_suppl.e14506   DOI
23 A. Schweikard, H. Shiomi & J. Adler. (2004). Respiration tracking in radiosurgery, Medical physics, 31(10), 2738-2741. DOI : 10.1118/1.1774132   DOI
24 J. M. Kuhnigk et al. (2005). New tools for computer assistance in thoracic CT. Part 1. Functional analysis of lungs, lung lobes, and bronchopulmonary segments, Radiographics, 25(2), 525-536. DOI : 10.1148/rg.252045070   DOI