• 제목/요약/키워드: 조합형 소음기

검색결과 9건 처리시간 0.031초

조합형 소음기를 이용한 박용 디젤 엔진 배기 소음 제어 (Exhaust Noise Control of Marine Diesel Engine Using Hybrid Silencer)

  • 이태경;주원호;배종국
    • 한국소음진동공학회논문집
    • /
    • 제19권7호
    • /
    • pp.679-684
    • /
    • 2009
  • Low frequency exhaust noise of marine diesel engine is one of the most important noise sources in vessels. However, conventional absorptive silencers are ineffective to control exhaust noise because of low absorption in the low frequency range. In the paper, exhaust noise control of marine diesel engine was studied by using the hybrid silencer, which was composed of virtually divided array of concentric hole-cavity resonators and conventional absorptive silencer. A series of tests including field tests were performed to investigate the acoustic performance of the hybrid silencer. Consequently, its high performance of 5${\sim}$10 dB noise reduction in the low frequency range was confirmed and it is expected to be very helpful in reducing the exhaust noise of marine diesel engine.

기하상사법을 이용한 대형 소음기의 성능평가에 관한 해석적 연구 (Analytical Study on Performance Evaluation of Large-Sized Silencer using Geometric Similarity Law)

  • 양준혁;이부윤;김원진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.275-281
    • /
    • 2010
  • 선박용 엔진 또는 플랜트 시스템에 사용되는 대형 소음기의 개발단계에서 비용절감 및 개발기간의 단축을 위하여 축소모형으로 대체 실험이 가능하도록 기하상사법을 제안하고자 한다. 대형 소음기를 구성하고 있는 공명형과 단순 확장관형 소음기의 원형과 축소 모형에 대한 이론식으로부터 기하상사 변수를 규명하였다. 그리고 음향해석을 통하여 조합형과 배플형의 축소 모형에 기하상사법을 적용하여 원형모형의 성능을 예측하고, 이를 원형모형의 실제 성능과 비교하는 방법으로 기하상사 변수를 검증하였다.

조합형 소음기를 이용한 육상발전용 디젤 엔진의 흡기 소음 제어 (Intake Noise Control of Diesel Power Plant using Combined Silencer)

  • 송근복;주원호;김동해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.861-866
    • /
    • 2012
  • Turbo-charger noise radiated from air intake part is one of the most important noise sources in diesel power plant. In this paper, intake noise control of the diesel power plant was studied using parallel baffle type silencer and concentric hole-cavity resonator simultaneously. Firstly, acoustical characteristics and attenuation performance for parallel baffle type silencer were investigated through theoretical approach and experimental method. Based on the results, optimal design of the parallel baffle silencer was suggested. Secondly, for reducing the low frequency noise contained in the intake noise, the concentric hole-type resonator was developed and the acoustic performance was verified from the test. By combining two types of silencers, it is expected that the overall insertion loss is about 50 dB. So, the combined silencer is very helpful in reducing the intake noise of diesel power plant.

  • PDF

디젤 엔진 발전기의 실외 소음원 규명 및 대책수립 사례 (Source Identification and Coutermeasure Application for Outdoor Noise of Diesel Engine Generator)

  • 김원진;전민규;김중기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.50-54
    • /
    • 1996
  • 최근들어 전력수요와 상시 전력공급이 요구되는 시설이 증가함에 따라 독립적으로 전력을 공급할 수 있는 상용 또는 비상용발전기가 많이 이용되고 있는 추세이다. 이러한 소형 발전시스템에는 디젤엔진이나 터빈 엔진에 발전기를 연결하여 전력을 공급하는 코젠 시스템(co-generation system)이 주로 이용된다[1]. 일반적으로 코젠시스템은 운전중에 매우 높은 수준의 소음이 발생되므로 건물 주변이나 사람의 왕래가 잦은 곳에 설치되는 경우에 필히 소음저감을 위한 대책이 필요하게 된다[2,3]. 본 사례는 대형놀이시설의 전력공급용으로 설치된 옥내(발전실내)의 상용/비상용 발전기(3600 KW 디젤엔진 2대)에서 발생한 상당량의 소음이 놀이시설주변까지 전달되어, 소음원 및 그 전달경로를 규명하고 대책을 수립한 내용이다. 놀이시설의 개장을 앞두고 소음문제가 발생되었기 때문에 신속하고 현실적인 해결책의 적용이 요구되었으므로 발전기 및 발전실 주변의 소음레벨 및 주파수특성의 분석을 통하여 주소음원을 규명하는 방법을 택했다. 분석결과로부터 주 소음원은 엔진 배기구에서 발생되는 저주파수 특성을 갖는 소음으로 규명되었고, 그 주파수특성에 적합한 흡음 및 반사특성을 동시에 갖는 조합형 2차 소음기를 추가로 설치하여 발전실 주변소음레벨을 크게 저감할 수 있었다.

  • PDF

흡음재가 조합된 헬름홀츠 공명기의 흡음성능 (Sound Absorption Performance of a Helmholtz Resonator combined with Porous Materials)

  • 이영철;이선기;송화영;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.280-285
    • /
    • 2008
  • The helmholtz resonator with the perforated neck has demerits that the absorption performance is not so outstanding in an anti-resonance frequency and high frequency bandwidth. In order to overcome these problems, in the paper, a resonator combined with porous material is proposed. The absorption performances of resonators are measured by two-microphone method and estimated by transfer matrix method. The experimentally measured values of normal absorption coefficients agree well with the corresponding values from the transfer matrix method. Because of the porous material, it is shown that the absorption performance have been significantly improved in the anti-resonance frequency and high frequency bandwidth.

  • PDF

선형모델을 이용한 수동변속기의 동적 특성 연구 (Study on the Dynamic Characteristics of a Manual Transmission Using Linear Models)

  • 윤종윤;이일재
    • 한국소음진동공학회논문집
    • /
    • 제23권3호
    • /
    • pp.240-248
    • /
    • 2013
  • 자동차 수동변속기 내 래틀과 같은 회전체 진동은 엔진 연소폭발 주기와 연동하여 발생한다. 이러한 충격형 진동 특성은 선형 시간 불변 분석법을 적용하여 살펴볼 수 있다. 기어의 동적 특성을 이해하기 위해, 특정 형태의 앞 바퀴 굴림 방식 수동 변속기에 대한 연구를 수행하였다. 첫째, 동특성 고유값과 주파수 응답함수를 기반으로 자유도를 줄이는 방법을 제시하였는데, 이는 행렬의 크기를 줄이는 효과적인 역할을 한다. 둘째, 단일 질량 플라이휠과 이중 질량 플라이휠의 동적 특성을 비교하였다. 모빌리티 분석을 기반으로 한 이중 질량 플라이휠의 효과를 검토하였는데, 이로부터 진동에 의해 가진되는 충격을 회피하기 위한 기본 개념을 이해 할 수 있다. 마지막으로, 두 단계 클러치 댐퍼로부터 유효 강성 값을 도출하여 선형 불변형 시스템 모델을 연구하였다. 두 단계의 서로 다른 클러치 강성조합을 이용하여 클러치 댐퍼의 동적특성에 대한 관계를 예측할 수 있다.

개량분기기 인근의 소음진동 시뮬레이션 (Simulation of Noise and Vibration around the Improved Turnout System)

  • 엄기영;엄주환;이진형
    • 한국시뮬레이션학회논문지
    • /
    • 제15권4호
    • /
    • pp.119-128
    • /
    • 2006
  • 철도운행에 있어 분기기는 열차를 주행선로에서 이웃한 선로로 이동시키는 매우 중요한 역할을 수행하는 장치로써 포인트부, 리드부 그리고 크로싱부로 이루어져 있다. 그러나 분기기는 레일 주변설비 중 유일한 가동부로 구조도 복잡하고 천이과정 중 차륜, 레일간의 급격한 운동변화가 필연적으로 발생되어 안전성 문제가 항상 거론되고 있다. 실제로, 국내외에서 차량의 탈선사고가 빈번히 발생되는 취약부위이기도 하다. 또한 차량, 궤도, 통신 그리고 전기 분야 등 분기기는 각각 다른 기능을 수행하는 매우 복잡한 장치들의 조합 시스템이므로 각각의 단위 개체들의 최적화만으로는 분기기의 전반적 성능을 향상시키기는 힘들며 이들에 대한 통합 기술의 확보가 필수적이다. 우리나라 철도는 기존선의 최고운행속도를 200km/h까지 향상 시키는 장기계획을 수립하고, 곡선부가 많은 우리나라 지형에 적합한 최고운행속도 180km/h의 틸팅열차를 개발 중이다. 그러나, 기존선로에 틸팅열차를 적용하기 위해서는 속고의 저감없이 틸팅열차를 통과시킬 수 있는 안정적인 분기기시스템의 확립이 선행되어야 한다. 본 연구에서는 틸팅열차 통과 시 기존선 속도향상을 위해 개발된 개량분기기 주변의 소음진동 정도를 예측하기 위해 시뮬레이션을 실시하였다.

  • PDF

타원 1-타원형 인벌루트-타원 2 로브 형상의 제로터 최적 설계 (Optimal Design of Gerotor with Combined Lobe Profiles (Ellipse 1-Elliptical Involute-Ellipse 2))

  • 곽효서;이승환;김철
    • 대한기계학회논문집A
    • /
    • 제39권12호
    • /
    • pp.1237-1244
    • /
    • 2015
  • 제로터(Gerotor) 오일펌프는 구조가 간단하고 1 회전당 토출량이 많기 때문에 소형화에 유리하며, 자동차의 엔진 윤활유 공급원 및 자동 변속기의 유압원으로 널리 사용되고 있다. 최근 자동차 산업에서는 연비향상 및 소음저감이 가장 중요한 문제로 대두되는데, 내접형 기어펌프 측면에서는 제로터의 치형설계 및 포트형상 설계를 통하여 이를 대처하고 있다. 이에 본 논문에서는 유량맥동이 매우 작은 값을 가지도록 조합된(타원 1-타원형 인벌루트-타원 2) 외부로브 형상에 대하여 치형의 기구학적 조건을 만족하는 식을 유도하여 내부로브 형상을 창출하였으며, 이에 대한 첨점 및 루프가 발생하지 않는 설계인자 범위를 결정하였다. 또한 설계인자의 변화가 치형의 형상 및 성능인자(유량, 유량맥동)에 미치는 영향을 파악하여 최적의 치형을 구하고자 하였다.

진화론적 알고리즘을 이용한 코깅토크가 적은 풍력발전기의 설계 (Design of a wind turbine generator with low cogging torque by using evolution strategy)

  • 박주경;차귀수;이희준;김용섭
    • 한국산학기술학회논문지
    • /
    • 제17권11호
    • /
    • pp.755-760
    • /
    • 2016
  • 근래에는 신재생에너지를 이용한 독립적인 발전기의 수요가 증가하고 있는 추세이며 그 중에서 소형 풍력발전기의 개발 또한 활발하게 이루어지고 있다. 이러한 소형 풍력발전기는 목적에 따라 단순화 및 소형화가 가능하도록 영구자석이 주로 쓰인다. 하지만 영구자석 동기기는 구조적인 원인으로 인하여 코깅토크를 수반하고 이는 소음과 진동의 원인이 된다. 코깅토크는 영구자석이나 코어의 형상에 의해 변하며 적절한 설계기법으로 코깅토크를 저감시킬 수 있다. 본 논문에서는 영구자석의 형상변화를 통해 소형 풍력발전기에 많이 사용되는 표면부착형 영구자석 동기전동기의 코깅토크를 저감시키는 설계기법을 제시하였다. 코깅토크를 줄일 수 있는 영구자석의 형상을 구하는 데에는 확률론적 최적화기법의 일종인 진화론적 최적화기법을 사용했다. 최적화 기법을 적용할 때에 설계변수로는 영구자석의 폭을 조절하는 각도와, 영구자석의 외경을 조절하는 반지름을 설정하였다. 제시된 설계기법을 사용해서 극/슬롯의 조합이 8극/18슬롯이고 출력이 300W급인 풍력발전기를 설계하고 코깅토크와 출력전압 등의 특성을 계산했다. 계산결과에 의하면 초기모델에 비해 최적화모델에서 코깅토크와 토크리플 모두가 감소해서, 본 연구에서 제시한 설계기법이 코깅토크를 줄이는 데에 효과가 있음을 확인하였다.