• Title/Summary/Keyword: 조직도플러

Search Result 18, Processing Time 0.018 seconds

Evaluation of Left Ventricular Tei Index in the Normal Dogs and Dogs with Mitral Valve Degenerative Disease (정상 및 퇴행성이첨판 질환이 있는 개에서 조직도플러를 통한 좌심실 Tei index의 평가)

  • Lee, In;Lee, Jung-Woo;Choi, Soo-Young;Han, Woo-Sok;Lee, Ki-Ja;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.2
    • /
    • pp.162-167
    • /
    • 2015
  • Tei-index has been reported as one of reliable echocardiographic factors for evaluating cardiac function in human and small animals. In this study, Tei-index were measured and evaluated with other echocardiographic parameters in normal thirteen beagle dogs and thirty-one dogs with mitral valve degeneration. Normal range of Tei index with tissue Doppler obtained at septum and left ventricular free wall was $0.58{\pm}0.07$ and $0.60{\pm}0.07$, respectively. The values between septum and left ventricular free wall did not show significant difference. Tissue Doppler derived tei index showed better reproducibility and significantly lower values than the results obtained by pulsed wave Doppler. Tei index obtained in either method increased with the progression of clinical signs. Therefore, the increase of Tei index in dogs with mitral regurgitation is thought to be an useful factor reflecting left ventricular dysfunction.

Diagnosis of Micro-Calcified Lesions of Breast Tissue Phantoms Using Acoustic Resonance Coupled with Power Doppler (공명현상과 파워도플러를 이용한 유방조직 팬텀의 미세 석회화 병변 진단)

  • Kim, Jeong-Koo;Ha, Myeung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Breast ultrasound has many advantages over mammography but suffers from a shortcoming of being not suitable in detecting microcalcification. We studied on a method based on acoustic resonance and power Doppler to detect calcification of breast tissue using a typical 7.5 MHz linear probe used in breast ultrasound examination. We first constructed a breast tissue phantom made of gelatin and then observed calcified legions as external vibrations varied. Calcification injected to the breast tissue phantom being resonated different from the surrounding medium, and its acoustic resonance driven by external vibrations was visualized by differences for color brightness and area in ROI of power doppler. In low frequency regions, the acoustic resonance almost not appeared and showed a plateau in $300{\sim}600\;Hz$ and the color vanished as the frequency further increased.

A Study on the Measurement of Tissue Blood Flow by the Self-Mixing Effect of Laser Diode (레이저 다이오드의 자기혼합 효과를 이용한 조직혈류 측정에 관한 연구)

  • Ko, Ran-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.57-64
    • /
    • 1994
  • This paper describes the measurement of tissue blood flow by the the self-mixing effect of laser diode. A Laser doppler signals due to the moving object and the tissue blood flow were detected by the self-mixing effect of laser diode. The Doppler shifted frequency was changed linearly with the driving frequency of moving object and was increase after the exercise. The results of in-vivo experiment were consistent with the result of exercise physiology.

  • PDF

Observation with Calcifications of Breast Tissue Phantoms Using Acoustic Resonance (공명현상을 이용한 유방조직 팬텀의 석회화 관찰)

  • Ha, Myeung-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Diagnosis of breast ultrasound is better than mammography in the early detection of breast cancer, but, it is difficult to detect microcalcification. We studied on detection for calcification of breast tissue using acoustic resonance and power doppler with 7.5 MHz linear probe in breast ultrasound. We first constructed breast tissue phantom made of gelatin and saw breast, and then observed calcification by the change of external vibration. Calcification injected breast tissue phantom visualized the difference for brightness and region of color in ROI regions of power doppler. Acoustic resonance almost never visualized in low frequency regions, plateau constituted in about 300-400 Hz and colors vanished according to the increase of frequency.

  • PDF

Evaluation of cardiac function by tissue Doppler imaging in children with cancer (Tissue Doppler imaging을 이용한 소아 종양 환자에서의 심기능 평가)

  • Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.417-423
    • /
    • 2006
  • Purpose : The objectives of this study were to assess ventricular function by tissue Doppler imaging in children who were receiving chemotherapy or who had received chemotherapy, and to apply repeated tissue Doppler imaging to make an early assessment in cardiac toxicity studies. Methods : This study was conducted on 23 oncology patients on-treatment or off-treatment from April 2005 to July 2005 at Dongsan Medical Center, Keimyung University. All patients(group 1) were divided into two groups, fractional shortening(FS) over 29 percent(group 2) and FS under 28 percent (group 3) in the first category. These same patients were also divided into the following groups : group treated with anthracyclin(group 4) and group treated without anthracyclin(group 5). Deceleration time(DT), isovolumic relaxation time(IVRT), FS, peak early diastolic(E), and peak late diastolic (A) velocity of transmitral flow were measured by M-mode and pulsed wave Doppler. Systolic(Sm), peak early diastolic(Em), and peak late diastolic(Am) velocity in apical 4-chamber and 2-chamber views were measured by tissue Doppler imaging. The author calculated a modified Tei index, E/A, E/Em ratio by using measured values. Results : Twenty three patients were enrolled : 12 boys and 11 girls. The average age of patients was 8 years and 4 months. Thirteen out of 23 patients were in the group treated with anthracyclin (group 4) and 6 had FS under 28 percent(group 3). E/Em ratio showed a significant difference between group 1 and control group($6.46{\pm}1.85$ vs $7.06{\pm}1.64$, P<0.05). Other parameters had no difference statistically. Conclusion : This study showed that the change of cardiac function developed earlier in diastolic function than in systolic function, as E/Em ratio reflecting the mean LV diastolic pressure showed a significant difference between the control group and chemotherapy groups. Echocardiography using tissue Doppler imaging is a non-invasive, comfortable and reliable method for post-chemotherapy follow up.

Evaluation of short-term cardiac function by tissue Doppler imaging in pre and postoperative period of congenital heart disease (조직 도플러 영상을 이용한 선천성 심장병 수술 전후의 단기 심기능 평가)

  • Lee, Jun-Hwa;Kim, Yeo-Hyang;Hyun, Myung-Chul;Lee, Sang-Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.476-483
    • /
    • 2007
  • Purpose : The objective of this study was to assess ventricular function by tissue Doppler imaging (TDI) in children with congenital heart disease (CHD) who have been undergoing open heart surgery (OHS) using cardiopulmonary bypass. We tried to compare the parameters of tissue Doppler imaging before and after OHS in patients with congenital heart disease. Methods : This study was conducted on 32 patients with CHD after OHS from January 2005 to December 2005 at Kyungpook National University hospital. Patients who underwent 2-D echocardiography before and after their OHS. All patients were divided into three groups, left ventricular volume overloading group (group 1), and right ventricular volume overloading group (group 2), and right ventricular pressure overloading group (group 3). The TDIs were examined before and 1 to 3 months after OHS. Peak early diastolic (E), and peak late diastolic (A) velocity of transmitral flow were measured by pulsed wave Doppler examination. Peak systolic (Sm), peak early diastolic (Em), and peak late diastolic (Am) velocity in apical 4-chamber and 2-chamber views were measured by TDI. The author calculated E/Em ratio. Results : The patients were 14 boys and 18 girls and the average age of patients was 2 years and 3 months. The congenital heart diseases which have to get OHS were ventricular septal defect (13 cases), atrial septal defect (7), atrioventricular septal defect (3), isolated pulmonary stenosis (2) and tetralogy of Fallot (7). There were significant decrease of Sm, Em, Am measured on tricuspid annulus and E/Em measured on mitral annulus in apical 4 chamber view (P<0.05). Conclusion : This study showed significant decrease of Sm, Em, Am measured on tricuspid annulus and E/Em measured on mitral annulus in apical 4 chamber view after OHS. These changes might be due to the effects of cardiopulmonary bypass in OHS and/or hemodynamic changes after correction of congenital heart disease. To clarify these changes, further study on more patients is needed.

Variation of parameters according to cardiac cycle length, evaluated by TDI in children (소아에서 심장 주기 시간 변화에 따른 조직 도플러 지표들의 변화양상)

  • Lee, Chang-Hyun;Kim, Jae-Kwang;Jin, Hyun-Seung;Park, Kie-Young;Kim, Bong-Seong;Han, Myung-Ki
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.3
    • /
    • pp.339-345
    • /
    • 2009
  • Purpose : This study aimed to determine the variation in parameters according to cardiac cycle length (CL; time interval between the QRS peaks on ECG) in children by using the conventional pulsed Doppler and tissue Doppler imaging echocardiography. Methods : Eighteen children with an anatomically normal heart were enrolled for the study. All children were examined by conventional and pulsed Doppler echocardiography at Gangneung Asan hospital between July 2006 and June 2007. We measured the CLs, mitral inflow velocities (E,A) and tissue Doppler imaging (TDI) parameters (s', e', a') from apical 4-chamber view. The TDI parameters were measured at the lateral (Lat) and septal (Sep) part of the mitral valve. All parameters were measured at 6 to 18 consecutive beats from each child. We then evaluated the linear correlation between CL and each parameter. Results : The mean age was $3.6{\pm}0.5$ years (M:F=8:10). There were significantly negative linear correlations between CL and A, Lat s', Lat a', Sep s', Sep e', Sep a' (P<0.01). There were significantly positive linear correlations between CL and E/A, Lat e'/a', Sep e'/a' (P<0.01). However, the E and Lat e' were not correlated with CL (P=0.229 and 0.221, respectively). Conclusion : This study showed that the values of the left ventricular functional parameters were changed according to CL. From our results, it is imperative to carefully examine beat-to-beat variations in children.

Laser Doppler blood flowmeter using self-mixing effect for the measurement of tissue blood flow. (조직혈류측정을 위한 자기혼합형 레이저 도플러 혈류계의 검토.)

  • Ko, Han-Woo;Choi, Duck-Hee
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.67-70
    • /
    • 1993
  • This preliminary study describes the self-mixing effect of laser diode for the measurement of tissue blood flow. A self-mixing effect of laser diode was detected by the single-mode laser diode and the moving target, and the Doppler shifted frequency was thanked linearly with the driving frequency of speaker. The measured Doppler shifted frequency was compared with the simulated data.

  • PDF

Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler (혈관협착팬텀의 제작 및 파워도플러의 영상 평가)

  • Park, Hee-Young;Bae, Jong-Rim;Kim, Jeong-Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.732-739
    • /
    • 2009
  • Flow phantom with stenosis was manufactured using an auto-injector to obtain angiostenotic flow information and quality assurance (QA) for ultrasound diagnostic instrumentation. Effectiveness of manufactured flow phantom with stenosis was investigated with power Doppler that was known to have diagnostic efficiency for angiostenosis. The flow phantom with stenosis was manufactured to 70% stenosis with 8 mm and 2.4 mm silicon tube, and silicone tube was covered with gelatin that has acoustic characteristics similar to soft tissue. When the linear transducer was used for measurement, the estimated diameter of normal vessel was measured lower than that of normal value, and the estimated diameter of stenosed vessel was measured higher than that of normal value. The measured parameters were not affected except for the radical conditions such as gain of 60%, PRF of 3000 Hz, use of maximal filter or angle. In addition, when the convex transducer was used for measurement, measurement parameters were affected by gain, PRF, filter, and angle. Therefore it is expected that flow phantom with stenosis manufactured with an auto-injector will be utilized effectively for QA of angiostenotic diagnosis.

Diagnostic Imaging of Isolated Splenic Torsion in a German Shepherd Dog (독일셰퍼드 견에서 단독으로 발생한 비장 염전의 영상진단)

  • Lee, Ki-Ja;Jeong, Seong-Mok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.613-616
    • /
    • 2011
  • A 5-year-old male German shepherd dog was presented with a 4 day-history of anorexia and depression. Abdominal radiographs showed a large soft tissue mass and loss of serosal detail. Ultrasonographs revealed splenomegaly with the lacy pattern parenchyma, perivenous hyperechoic region at the splenic hilum, and loss of splenic venous flow. Computed tomographic findings included the enlarged non-enhanced spleen except perivenous region at the splenic hilum and a whirled soft tissue mass at the splenic hilum. Exploratory laparotomy confirmed the diagnosis of splenic torsion. Ultrasonographic findings including lacy appearance, hyperechoic perivenous echogenicity and absence of splenic blood flow and CT findings including no or minimal enhancement of the spleen and a whirled appearance of splenic pedicle could be useful for diagnosing isolated splenic torsion in the dog.