• Title/Summary/Keyword: 조절근점

Search Result 25, Processing Time 0.019 seconds

The Change of Near Point of Convergence and Fusional Reserves after Computer Gaming with Different Direction of Eye Movement (안구의 운동방향이 다른 컴퓨터 게임 후 폭주근점과 융합여력의 변화)

  • Kim, Se Il;Kwon, Ki-Il;Lee, Jiye;Lee, Hyo Jin;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: The present study was conducted to investigate whether the directions of eye movement in playing computer games for certain period affected the change of near point of convergence (NPC) and fusional reserve (FR) or not. Methods: Total 40 subjects in 20s who have the visual acuity of 1.0 or higher without any ocular disease and accommodative dysfunction were asked to successively play computer games. After the subjects were moving eyes in horizontal and vertical directions for 40 and 90 minutes, their horizontal fusional reserves, vertical fusional vergence and near point of convergence were measured. Results: The near point of convergence showed a tendency to be receded after computer gaming in the horizontal and vertical directions, and both of horizontal and vertical fusional reserves were significantly reduced. The range of declined fusional reserves and receded near point of convergence after computer gaming for 90 minutes was smaller than those after computer gaming for 40 minutes. The change of binocular vision was affected by the horizontal eye movement rather than the vertical movement when analyzed by the direction of eye movement. Conclusions: This study revealed that the change in FR and NPC was different along with dominant direction of eye movement during visual display terminal (VDT) tasks. Therefore, the adjustment of VDT working time is required to prevent the dysfunction of binocular vision according to the dominant direction of eye movement during VDT task.

Comparison of Binocular Function in Normal Subjects and Convergence Insufficiency (정상안과 폭주부족안의 양안시기능 검사값 비교)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.287-291
    • /
    • 2010
  • Purpose: The aim of this study was to compare binocular functions such as near point of convergence (NPC), AC/A ratios, heterophoria, accommodation, accommodation lag, positive relative accommodation (PRA), negative relative accommodation (NRA), positive relative convergence (PRC), negative relative convergence (NRC) in normal subjects and convergence insufficiency. Methods: 86 subject (male n=45, female n=41, mean $age{\pm}SD=23.27{\pm}2.85$ years) without amblyopia, strabismus, and ocular pathology were studied. Forty three patients each group were classified as normal subjects and convergence insufficiency group based on AC/A ratio and far and near phoria. Binocular function of the two groups was measured using phoropter. r. Results: The values between normal subjects and convergence insufficiency were 5.71 cm and 7.07 cm for NPC, 5.28 and 2.81 for Heterophria AC/A, 0.92 exo/3.36 exo and 2.17 exo/10.84 exo for far and near phoria, 15.49/23.30/13.30 and 13.50/20.02/9.09 for PRC, respectively. However, there were no significant differences between normal subjects and convergence insufficiency for accommodative amplitude, accommodative lag, PRA, NRA, BI vergence test, BO vergence test, NRC. Conclusions: Both groups were a significant difference for cover test, NPC, Heterophria AC/A, far and near phoria, break point of PRC, and recovery point of PRC.

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.

Time-dependent Changes of Ocular Functions after Alcohol Ingestion (알코올 섭취 후 시간경과에 따른 시 기능의 변화)

  • Kim, Sang-Yoeb;Moon, Byeong-Yeon;Lee, Sun Haeng;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.133-138
    • /
    • 2009
  • Purpose: This study was designed to investigate the changes of vision and ocular functions induced by increase of blood alcohol level. Methods: Blood alcohol level, vision, refractive errors, near point convergence, heterophoria, and relative convergence were measured at 1 h, 4 h, and 24 h after acute alcohol ingestion of 0.7 g per kg body weight. Results: At 1 h after alcohol ingestion, myopization and ocular functions which measured near point convergence, positive and negative convergences, and degree of heterophoria remarkedly worked a changes accompanied with the maximum value of blood alcohol level. But at 24 h after that, all of ocular functions were recovered to degree of 90~99% compared with non-alcoholic normal conditions. Conclusions: As the increase of blood alcohol level is able to induce the significant changes of visual acuity and ocular functions, opticians have to understand thoroughly the patient's conditions by alcohol ingestion before refractive test and ocular examinations.

  • PDF

Change of Binocular Vision Induced by Longitudinal Chromatic Aberration during Near Work (근거리 작업 시 종색수차에 따른 양안시의 변화)

  • Kim, Se-il;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.219-228
    • /
    • 2015
  • Purpose: The current study was performed to compare the difference in binocular visual function depending on variable background colors at near work. Method: Fifty four adults (18 males, 34 females) who consented to the present study and had no ocular disease, ocular surgery history, strabismus and amblyopia with normal binocular vision were participated into this study. The subjects were asked to read the novels with black letter printed on white, red, green and blue background for 15 min. Then, their heterophoria, AC/A ratio, near point of convergence, accommodation facility, relative accommodation and vergence were measured before and after reading. The difference of measurements were compared. Result: Overall heterophoria was tended to decrease with regardless of background color. AC/A ratio showed a tendency of increase after reading the novels with all backgrounds except white background. Near point of convergence was significantly increased compared to before reading at all background color. Accommodative facility of dominant and non-dominant eyes were also significantly increased after reading however, binocular accommodative facility showed a tendency of decrease. Negative relative accommodation also decreased at all background colors however, the change of positive relative accommodation was not significantly different. In case of vergence, there was significant difference in break point of far BO and recovery point of far BI by the wavelength of background color. Conclusions: From the results, it was known there is convergence change depending on the wavelength of light even though same amount of accommodation and convergence is required when doing near work for certain period. Thus, it can be suggested that the adjustment of the near working environment which perception of various color was required, should be conducted according to the main wavelength.

Effects of Variation of Illumination on Visual Function Factors (조도변화가 시기능 성분에 미치는 영향)

  • Kim, Da-Young;Kim, Sang-Yeob;Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.195-200
    • /
    • 2015
  • Purpose: This study was performed in order to figure out the influence of illumination on visual function. Methods: 40 adults (male 21, female 19) of average age $23.93{\pm}1.59$ years were participated in this study. The test chart surface illumination was adjusted to 5, 50, 200, 500 and 800 lx, and then amplitude of accommodation, near point of convergence, far and near distance phoria, far and near distance fusional vergence, relative accommodation, and accommodation lag were measured at each illumination condition. Results: As illumination intensity of test chart was reduced, amplitude of accommodation was significantly decreased (p<0.05), accommodation lag was also decreased, near point of convergence was receded, and horizontal phoria showed a tendency of esodeviation. In the case of negative fusional vergence, with reduction of illumination intensity, the break point and the recovery point were decreased but in the case of positive fusional vergence, the break point was increased. The negative and positive relative accommodation were significantly decreased (p<0.05) with reduction of illumination intensity. Conclusions: In clinical practice, visual functional test should be performed under condition of adequate illumination level through patient's living environment and job.

Influence of Different Diagnostic Criteria on Frequency of Convergence Insufficiency (진단기준 차이가 폭주부족의 빈도에 미치는 영향)

  • Yu, Dong-Sik;Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.235-242
    • /
    • 2016
  • Purpose: This study was to investigate whether the application of different diagnostic criteria affected the frequency of convergence insufficiency (CI). Methods: Eighty one subjects with mean age of 22.54 years (20 to 27 years) were evaluated. Binocularity tests after refraction were performed as the following tests: near point of convergence (NPC) with an accommodative target, phoria using von Graefe method, positive fusional vergence (PFV) with a phoropter. Subjects with CI were diagnosed when exophoria (exo) was greater at near than at distance ($exo{\geq}4{\Delta}$, or >$6{\Delta}$), fusional vergence was $PFV{\leq}11{\Delta}$ for blur, $PFV{\leq}15{\Delta}$ for break, Sheard's or Percival's criterion, and NPC was $NPC{\geq}6cm$, ${\geq}7.5cm$ or >10 cm. Results: Frequency of CI with one diagnostic criterion was ranged from 6.2% to 77.8%, and was overestimated or underestimated according to criteria. It was reduced to the range of 6.2% to 43.2% with diagnostic criteria more than two, especially to the range of 24.7% to 28.4% with lower variability in diagnostic criteria including phoria and Sheard's criterion. There were high relationship between total score of signs and phoria score (r = 0.772, p<0.001), and measured phoria and Sheard's criterion (r = -0.654, p<0.001), but NPC had a high variability and a weak or no significant relationship with other diagnostic criteria. Results suggested $exo{\geq}4{\Delta}$, Sheard's criterion and $NPC{\geq}7.5cm$ for diagnostic criteria of signs and sequence for CI. Conclusions: Frequency of CI is likely to be over- and underestimated with diagnostic criteria. Cutoff values and procedures for phoria, Sheard's criterion and NPC as clinical signs should be suggested definitely in diagnosis associated with CI.

The Investigation of the Changes of Visual Problems in VDT Workers (VDT 작업 전·후 시기능 변화)

  • Gang, Myoung Jin;Choe, Oh Mok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.33-39
    • /
    • 2002
  • The purpose of this study is to evaluate the effects of continuing work on VDT(video display terminal). Therefore, we examined visual fatigue by a questionnaire and measured frequency of blinking, tear film break-up time(BUT), height of palpebral fissure, visual acuity, refraction with retinoscopy and accommodation before and after two hour long VDT work. For the ocular symptoms, the greatest number was tired eyes accounting for 34%. In the visual symptoms, blurred vision was the highest rate of 83% and in case of systemic symptoms, shoulder pain was 38% marked top ranking but other symptoms were also distributed similar rate. The frequency of blinking during VDT work decreased significantly comparing with the one at rest. The average frequency of blinking is 8/min during VDT work and 22/min at rest. The BUT measured immediately after VDT work decreased much more than in the resting state. The average BUT was 7sec immediately after VDT work and 12sec at rest. The height of palpebral fissure during VDT work increased significantly comparing with the value at rest. The average height of palpebral fissure was 7.69mm at rest and 9.04mm during VDT work. The average visual acuity decreased almost 9.5% from 0.63 to 0.57, but refraction with retinoscopy increased about 0.28D to the direction of myopic shift. The amplitude of accommodation decreased approximately 1.49D from 7.98D to 6.49D and this resulted from the prolongation of near point of accommodation. Near point of convergence also was prolongated from 9.45cm to 10.30cm after VDT work.

  • PDF

Relationships between Reading Ability and Binocular Vision (읽기능력과 양안시기능의 관계성)

  • Kim, Young Ji;Lee, Min-A;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.171-177
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the relationships between reading ability and binocular functions, based on self tests through surveys. The possibility of the reading ability tests used in this study as a tool on the determination about vision efficiency was also evaluated. Methods: Through reading ability tests about 138 university students, 72 students (52.2%) of them were first selected. Through self tests about dyslexia and light sensitivity, 38 students (52.7%) of the first selected students were secondly selected, whose extents are more than 3. Binocular tests were carried out about three groups (high, middle, low) of these secondly selected students. Tests about NPCs, distance and near phoria, amplitude of accommodation, fusional vergence, AC/A ratio, accommodative facility, and vergence facility were performed as binocular tests. Results: NPCs were closest to eyes at high groups. Fusional vergence, AC/A ratio, accommodative facility, and vergence facility of high group showed higher than other groups. The phoria at middle group showed higher than other groups. Conclusions: We found that reading ability and some of binocular functions were closely related. Therefore, vision training, associated with insufficiencies of binocular functions, is expected to improve reading ability.

Analysis of Binocular Abnormality by Eyeball Motion in Ametropia (비정시의 안구운동에 의한 양안시 이상 분석)

  • Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.205-213
    • /
    • 2005
  • To evaluate the reliability of binocular vision measurements by phorometry. 90 students volunteered to participate in this study. 25 subjects were males, and 65 were females, they ranged in ages from 21 to 30 years. All subjects had normal ocular and systematic health, and all of them had at least 1.0 visual acuity with their best correction. At negative relative convergence(NRC) measurement in distance, the percentage of subjects is included in expected value(blur point/break point/recovery point) was 78%/61%/67%, divergence excess(DE) was 9%/31%/33%, and divergence insufficience(DI) was 13%/8%/9%, respectively. And positive relative convergence(PRC) measurement, includes expected value was 20%/46%/39%, convergence excess(CE) was 22%/14%/16%, and convergence insufficience(CI) was 35%/40%/45%. AC/A ratios of 42 subjects were normal. 38 were low, and the rest of them high. A low AC/A ratio is usually the result of a small vergence response in relation to accommodation. Negative relative convergence(NRC) at near, includes expected value was 26%/29%/44%, divergence excess(DE) was 61%/33%/24%, and divergence insufficience(DI) was 3%/38%/32%. And PRC at near, includes expected value was 33%/40%/31%, convergence excess(CE) was 61%/23%/42%, and convergence insufficience(CI) was 6%/37%/27%. For the near point of convergence(NPC) test, 58% of their subjects had a break of ${\leq}8cm$ with the accommodative target. In case of NRA(PRA) measurement, the expected value was 41%(33%). Accommodative insufficiency (AI) was 33%(43%), and accommodative excess(AE) was 26%(24%), respectively. AE was related to respectively low values of NRA. AI and CE are associated with high value of NRA, and the dysfunction of convergence excess combined with AE was related to a normal-high values of NRA. PRA in AI was related to a low value, wheres the dysfunction are associated with high values of PRA.

  • PDF