A Study on the Radiation Dose in Computed Tomographic Examinations (전산화단층촬영 검사의 방사선 선량에 관한 연구)

  • Lim, Chung-Hwang;Cho, Jung-Keun;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.381-389
    • /
    • 2007
  • The purpose of this study is investigation of radiation dose in CT scan. Data were collected from various references and organizations. Doses measured by CT scanners of each medical organization were analyzed and they were calculated through the examination protocol. The results are as follows : 1. $CTDI_W$ value per 100mAs measured by Head Phantom was the highest in <4-slice MDCT scanner> of 24.20 mGy. $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 2. $CTDI_W$ value per 100 mAs measured using body phantom was the highest in <4-slice MDCT scanner> of 13.58 mGy and the $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 3. When contrast medium was not used, the highest scanner was <16 slice MDCT> of $818.83\;mGy{\codt}cm$ in exposure dose in brain scan(p < 0.05). When the contrast medium was used, the highest scanner was <4 slice MDCT> and its average was $1,460.77\;mGy{\cdot}cm$(p < 0.1). 4. When the contrast medium was not used, the highest scanner was <16-slice MDCT> of $521.63\;mGy{\cdot}cm$ on average in terms of the exposure dose in chest inspection(p<0.05). when the contrast medium was used, the highest scanner was found in 8 slice MDCT scanner and its average was $1,174.70\;mGy{\cdot}cm$. There was no statistically significant difference among scanners. 5. When the contrast medium was not used, the highest scanner was <16-slice MDCT> and its average was $856.27\;mGy{\cdot}cm$ in exposure dose on the abdomen-pelvis(p<0.05). when the contrast medium was used, the highest scanner was <16-slice MDCT> and its average was $1,720.64\;mGy{\cdot}cm$ on average (p < 0.05). 6. When the contrast medium was not used, the highest scanner was <8-slice MDCT> and its average was $612.07\;mGy{\cdot}cm$ in exposure dose in liver inspection(p < 0.05). when the contrast medium was used, the highest scanner was <8-slice MDCT scanner> and its average was $2,197.93\;mGy{\cdot}cm$ in exposure dose(p < 0.1). seventy six point two percent of medical facilities were in risk of radiation exposure while the number of phase was three to four times in their dose inspection of contrast medium.

  • PDF

Effects of Gadolinium Contrast agent on Bone Mineral Density Measurement using Dual Energy X-ray Absorptiometry (가돌리늄조영제가 이중에너지 X-선 흡수법을 이용한 골밀도검사에 미치는 영향)

  • Lee, Keun-Ohk;Lee, Min-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Radiographic contrast agents are used for diagnostic purposes and are one of the factors affecting measured values in bone density tests. They are absorbed into tissues and have an effect of increasing the measured values of bone density, so they are avoided as much as possible before performing a bone density test. MRI contrast agents, which have different physical properties and mechanisms of action than radiographic contrast agents, are based on gadolinium, a metal element. They have radiopacity characteristics, so MRI are generally performed prior to examination using radiation. The purpose of this study was to investigate the effects of MRI contrast agents on bone mineral density examination using dual energy X-ray absorption. Two types of gadolinium based MRI contrast agents were injected into an acrylic water tank for each volume, and the humanoid spine phantom was inserted and the BMD and T-score from (L1-L4) were analyzed by scanning a total of 30 times, 5 times for each injection type. The average value of the measured total (L1-L4) bone density for each of the two contrast agents was 0.952±0.052, 0.957±0.050, and 0.956±0.05g/㎠, respectively, for the Gadoterate Meglumine component 0mL, 7.5mL and 15mL, when the gadobutrol components were 0mL, 5mL, and 10mL, there was no statistically significant difference at all sites at 0.953±0.001, 0.954±0.001, and 0.945±0.001g/㎠, respectively(p>0.05). The average value of total T-score was -0.46±0.05, -0.4±0, -0.42±0.04 when the Gadoterate Meglumine component was 0mL, 7.5mL and 15mL, respectively. When the Gadobutrol ingredients were 0mL, 5mL and 10mL, there was no statistically significant difference in all areas, with -0.46±0.05, -0.46±0.05, and 0.5±0.00, respectively. In this experiment, the MRI contrast agent was found to have no effect on bone density tests, using the dual-energy X-ray absorption method. There is a limitation in that physical conditions such as kidney and health conditions etc. were not taken into consideration, so further clinical research is expected to be conducted in the future.

Subcutaneous Injection Contrast Media Extravasation: 3D CT Appearance (전산화단층검사에서 조영제의 피하 정맥 혈관외유출 환자의 3D영상)

  • Kweon Dae Cheol;Kim Tae Hyung;Yang Sung Hwan;Yoo Beong Gyu;Kim Myeong Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.47-51
    • /
    • 2005
  • We report a case of an accidental extravasation of contrast material. A large-volume extravasation occurred in an adult during spiral contrast-enhanced CT. The amount of contrast material extravasated was 47 ml. The patient had a swelling of the dorsum right hand. The extravasation injury site was determined by CT scanning. The extavasation case was examined using five separate display techniques: axial, multi planar reformation (MPR), maximum intensity projection (MIP), volume rendering, and shaded-surfaced display (SSD). This paper introduces extravasation with the CT and the three-dimensional appearance.

  • PDF

Evaluation of the Usefulness of a Wireless Signal Device for the Use of Contrast Agent in Computed Tomography (전산화단층촬영에서 조영제 주입에 따른 무선신호기 사용의 유용성평가)

  • Hong, Ki-Man;Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.417-425
    • /
    • 2018
  • The psychological anxiety of radiologists, as well as the patients, is growing with the increasing use of CT contrast agent side effects and the process of extravasation. In this study, a satisfaction survey was conducted regarding the wireless signal device after CT examination in patients and radiologists by employing a wireless signal device during a contrast-enhanced CT examination in order to determine its usefulness to the relieve psychological anxiety, such as anxiety and fear, of patients and radiologists when using contrast agents. The use of a wireless signal device was also intended to help radiologists in dealing with the side effects of contrast agents that may occur during a CT examination and preventing extravasation. Patients aged 20 years or older, who visited the C university hospital in Jeonnam province for 4 months from August to November in 2017, were surveyed. A total number of 90 patients (57 males and 33 females),who agreed to the study after CT examination, were included in the questionnaire survey. Meanwhile, 15 radiologists, who were working at a CT room and had an experience in using a wireless signal device, were surveyed. Patient satisfaction was $6.01{\pm}0.88$ before the use of a wireless signal device and $8.20{\pm}1.06$ after use, thereby showing an increased satisfaction after its use. Radiologist satisfaction was $8.46{\pm}1.06$ after use, thereby not showing a big difference from the mean patient satisfaction. The satisfaction was high at over 8 points in both groups. The contribution to psychological stability with the use of a wireless signal device was $8.98{\pm}0.65$ in patients with prior experience of side effects and $8.00{\pm}1.21$ in patients without prior experience of side effects. In conclusion, it is considered to improve satisfaction with the examination by helping the radiologists in taking immediate action with calling via the wireless signal device and providing the patients and radiologists with psychological stability by reducing their anxiety.

The methods of distinguishing between HCC and HH in Liver CT scan (Liver CT 영상에서 간세포암과 간혈관종 구별에 대한 연구)

  • Hwang, In-gil;Ko, Seong-Jin;Choi, Seok-Yoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.173-174
    • /
    • 2015
  • 간에서 발생하는 악성종양과 양성종양의 대표적 질환 으로는 간세포암(Hepatocelluar carci- noma, HCC)과 간혈관종(Hepatic hemangioma, HH)이다. CT검사를 이용한 진단에 있어서 두 질환은 시간변화에 따른 조영증강양상 차이가 나타난다. Liver 3-phase computed tomography검사를 시행하여 시간별 조영증강 양상을 알아보았다. 본 연구는 조영제 주입전, 동맥기(35sec), 문맥기(70sec), 지연기(180sec)에 대한 Enhan -cement Pattern 변화와 HU(Hounsfield unit)값 변화, pixel값 변화의 관찰로서 검증하였다. 실험결과 HU를 사용한 방법에서 의미있게 구분되었고 임상적용 시 판독에 도움을 줄 것으로 생각한다.

  • PDF

Expert Opinion Questionnaire About Chest CT Scan Using A Negative Pressure Isolation Strecher in COVID-19 Patients: Image Quality and Infection Risk (COVID-19 환자에서 음압격리들것을 이용한 흉부 CT 검사에 대한 전문가 의견 설문: 영상품질과 감염위험)

  • Kwang Nam Jin;Bo Da Nam;Jaemin Shin;Sung Ho Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.891-899
    • /
    • 2023
  • Purpose To survey perceptions of certified physicians on the protocol of chest CT in patients with coronavirus (COVID-19) using a negative pressure isolation stretcher (NPIS). Materials and Methods This study collected questionnaire responses from a total of 27 certified physicians who had previously performed chest CT with NPIS in COVID-19 isolation hospitals. Results The nine surveyed hospitals performed an average of 116 chest CT examinations with NPIS each year. Of these, an average of 24 cases (21%) were contrast chest CT. Of the 9 pulmonologists we surveyed, 5 (56%) agreed that patients who showed abnormalities in serum D-dimer required contrast chest CT. All 9 surveyed radiologists agreed that the image quality of the chest CT with NPIS was sufficient for CT image interpretation regarding pneumonia or pulmonary embolism. Furthermore, in our 9 surveyed infectionologists, 5 (56%) agreed that a risk of secondary infection in the CT room after temporary opening of NPIS could be prevented through a process of disinfection. Conclusion Experienced physicians considered that the effects of NIPS on chest CT image quality was minimal in patients with COVID-19, and the risk of CT room contamination was easily controlled.

A Convergence Study on effectiveness of contrast agent reduction by normal saline solution dilution in the computed tomography of arteries of lower limb (하지동맥 전산화단층촬영 검사 시 생리식염수 희석을 통한 조영제 사용량 감소의 융복합 효용성 연구)

  • Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.431-437
    • /
    • 2015
  • This convergence study analyzed the effectiveness of contrast agent reduction by normal saline solution dilution in the computed tomography of arteries of lower limb. 48 patients of 125 cc contrast agent and 30 patients of the same amount divided at a ratio of 7:3 for the contrast agent and normal saline solution were studied. The average attenuation coefficient(HU) and signal to noise ratio(SNR) of abdominal aorta, femoral artery, popliteal artery and posterior tibial artery at each image were evaluated quantitatively and the four criteria in the five point scale was conducted qualitatively by two radiologists and four radiological technologists. In the quantitative evaluation, both HU and SNR had high average score before dilation but there were no statistical significance by independent t-test(p>0.05). In the qualitative evaluation, there were a little differences in the average scores between 4.86~4.77 of original contrast agent and 4.83~4.67 of dilated contrast agent but there were no statistical significance(p>0.05). In the computed tomography of arteries of lower limb, the dilated contrast agent doesn't influence image quality and reduces overall contrast agent and lowers iodine content per unit of molecular therefore will contribute to decrease side effect of contrast agent.

Evaluation of the Low Tube Voltage in the Computed Tomography Scan Technique using a Low Concentration Contrast Agent (저농도 조영제를 사용한 CT검사에서 저관전압 기법에 따른 유용성 평가)

  • Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.71-79
    • /
    • 2016
  • The purpose of this study is computed tomography contrast agent at low concentrations and low tube voltage technique to evaluate the usefulness on the phantom image. By varying the degree of mixture by the contrast medium concentration it was inserted in phantom. It was taken by changing the tube voltage and tube current step by step, and to evaluate the dose and the CT value obtained from the phantom image. As a result, low-contrast, low tube voltage(300 mgI/ml, 100 kV) was reduced by an average 21%(CTDIvol; computed tomography dose indexvol) more standard condition(350 mgI/ml, 120 kV). SNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 12.2(26%) 6.2(17%). CNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 11.5(32%), 6.3(26%). Research work on the CT scan is necessary in a variety of studies on the low contrast concentration and low tube voltage techniques for dose reduction and reducing of side effects the contrast agent.

The Development of Extravasation Detection Accessory System for the Preventive Contrast Media Extravasation in the Computed Tomography: A Preliminary Report (CT 검사에서 조영제의 혈관외유출 예방을 위한 EDA 시스템 개발의 예비 보고)

  • Kweon Dae-Cheol;Jeong Seok-Hee;Kim Tae-Hyung;Kim Jeong-Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.32-39
    • /
    • 2006
  • To assess the ability of an extravasation detection accessory (EDA) system to detect clinically important extravascular injection of iodinated contrast material delivered with an automated power injector. Fifty patients referred for contrast material enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically Important extravasation. The presence or absence of extravasation was definitively established with multi-detector CT at the injection site (injection rate, $2.0{\sim}2.5$ mL/sec). There were two true positive, extravasation volumes $22{\sim}25$ mL. The EDA system had sensitivity in the detection of clinically important extravasation. The EDA system is easy to use, safe, and accurate In the monitoring of intravenous injections for extravasation, which may prove especially useful in CT applications.