• Title/Summary/Keyword: 조석간만

Search Result 184, Processing Time 0.03 seconds

Role of Intra-aortic Balloon Pump in High Risk Patients undergoing Off-Pump Coronary artery bypass graft (심폐바이패스 없이 시행하는 관상동맥 우회술시 고위험군 환자에서 대동맥내 풍선 펌프의 유용성)

  • Cho, Suk-Ki;Jang, Woo-Ik;Lim, Cheong;Lee, Cheul;Lee, Jae-Ik;Kim, Yong-Lak;Ham, Byung-Moon;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.34 no.12
    • /
    • pp.895-900
    • /
    • 2001
  • Background : This study aimed to evaluate the usefulness of preoperative placement of intraaortic balloon pump(IABP) in reducing operative risk and facilitating posterior vessel OPCAB in high risk patients with left main disease( 75% stenosis), intractable resting angina, postinfarction angina, or left ventricular dysfunction(ejection fraction 35%). Material and Method : One hundred eighty- nine consecutive patients who underwent multi-vessel OPCAB including posterior vessel revascularization were studied. The patients were divided into group I(n=74) that received preoperative or intraoperative IABP and group II(n=115) that did not receive IABP. In group I, there were 39 patients with left main disease, 40 patients with intractable resting angina, 14 patients with left ventricular dysfunction and 7 patients with postinfarction angina. Ten patients received intraoperative IABP support due to hemodynamic instability during OPCAB. Result : There was one operative mortality in group I and two mortalities in group II. The average number of distal anastomoses was not different between group I and group II(3.5$\pm$0.9 vs 3.4$\pm$0.9, p=ns). There were no significant differences in the number of posterior vessel anastomosis per patient between the two groups. There were no differences in ventilator support time, length of hospital stay, and morbidity between the two groups. There was one case of IABP-related complication in group I. Conclusion : IABP facilitates posterior vessel OPCAB in high risk patients, with comparable surgical results to low risk patients

  • PDF

The Study on the Seasonal Variation of Microbial Community in Kyeonggi Bay, Korea II. Nano-and Microzooplankton (경기만 수역에서 미세생물 군집의 계절적 변동 연구 II. 미소형 및 소형 동물플랑크톤)

  • 양은진;최중기
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.8 no.2
    • /
    • pp.78-93
    • /
    • 2003
  • To investigate seasonal variation and structure of the microbial community in Kyeonggi Bay, abundance and carbon biomass of nano-and micrzooplankton were evaluated in relation to size fractionated chlorophyll-a concentration, through the monthly interval sampling from December 1997 to November 1998. Communities of nano-and microzooplankton were classified into 4 groups such as heterotrophic nanoflagellate(HNF), ciliates, heterotrophic dinoflagellates(HDF) and zooplankton nauplii. Abundance and carbon biomass of HNF ranged from 380 to 4,370 cells ml-1(average 1,340$\pm$130 cells ml-1) and from 0.63 to 12.4 $\mu\textrm{g}$C 1-1(average 4.35$\pm$0.58 $\mu\textrm{g}$C 1-1), respectively. Abundance and carbon biomass of ciliates ranged from 331 to 44,571 cells ml-1(average 3,526$\pm$544 cells ml-1) and from 1.3 to 119.7 $\mu\textrm{g}$C 1-1(average 13.7$\pm$3.0 $\mu\textrm{g}$C 1-1), respectively. Abundance and carbon biomass of HDF ranged from 88 to 48,461 cells 1-1(average 9,034$\pm$2,347 cells 1-1) and from 0.05 to 54.05 $\mu\textrm{g}$C 1-1(average 6.9$\pm$2.4 $\mu\textrm{g}$C 1-1), respectively. Abundance and carbon biomass of zooplankton nauplii ranged from 5 to 546 indiv. 1-1(average 83$\pm$15 indiv. 1-1) and from 0.17 to 43.2 $\mu\textrm{g}$C 1-1(average 6.3$\pm$1.2 $\mu\textrm{g}$C 1-1), respectively. Eash component of microbial biomass was not different from tidal cycle except tintinnids group. Depth integrated nano-and microzooplankton biomass ranged from 124 to 1,635 mgC m-2(average 585$\pm$110 mgC m-2) and was highest in March and May. The relative contribution of each component to the nano-and microzooplankton showed difference according to seasons. Community structure of nano-and microzooplankton was dominated by planktonic ciliate group. During the study period, carbon biomass of nano-and microzooplankton was strongly positively correlated with size fractionated chlorophylla-a. It implied that prey-predator relationship between microzooplankton and phytoplankton was important in the pelagic ecosystem of Kyeonggi Bay.

The Consideration of the Region of Interest on $^{99m}Tc$-DMSA Renal Scan in Pediatric Hydronephrosis Patients (수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰)

  • NamKoong, Hyuk;Lee, Dong-Hyuk;Oh, Shin-Hyun;Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Purpose: Most of diagnosis in the pediatric hydronephrosis patients have been performed $^{99m}Tc$-DMSA renal scan. Then the region of interest (ROI) is set for comparative analysis of uptake ratio in left-right kidney after acquiring the image. But if the equipment set an automatic ROI, the ROI could include expanded renal pelvis due to hydronephrosis and the uptake ratio of left-right kidney will be incorrect result. Therefore this study compared both ROIs including expanded renal pelvis and excluding renal pelvis through experiment using normal kidney phantom and expanded renal pelvis phantom and suggested setting method of improved ROI. In addition, this study have been helped by readout doctor for investigate distinction radiopharmaceutical uptake between renal cortex and remained urine by expanded renal pelvis. Materials and Methods: The both of renal phantoms were filled with water and shacked with $^{99m}TcO_4$ 111 MBq. In order to describe the expanded renal pelvis, the five latex balloon were all filled with 10 mL water and each of balloon was mixed with $^{99m}TcO_4$ 18.5, 37, 55.5, 74, 92.5 MBq. And we made phantom with fixed $^{99m}TcO_4$activity of 37 MBq and mixed water 5, 10, 15, 20, 25 mL in each balloon. The left kidney was fixed its shape and the right kidney was modified like as hydronephrosis kidney by attached the latex balloons. And the acquiring counts were 2 million. After acquisition, we compared the image of ROI with Expanded renal pelvis and the image of ROI without renal pelvis for analyzing difference in the uptake ratio of left-right kidney and for reproducibility, set the ROI 5 times in the same images. Patients were injected $^{99m}Tc$-DMSA 1.5~1.9 MBq/kg and scanned 3 to 4 hours after injection. The each of 3 skillful radio technologists performed the comparing estimation by setting ROI. To determine statistical significance between two data, SPSS (ver. 17) Wilcoxon Signed Ranks Test was used. Results: As a result of renal phantom's experiment, we compared with average of counts Background (BKG) ratios in the setting of ROI including expanded renal pelvis and setting of excluding expanded renal pelvis. Therefore, they can obtain changed counts and changed ratios. Patient also can obtain same results. In addition, the radiopharmaceutical uptake in expanded renal pelvis was come out the remained urine that couldn't descend to ureter by the help of readout doctor. Conclusion: As above results, the case of setting ROI including expanded renal pelvis was more abnormally increasing uptake ratio than the case of setting ROI excluding expanded renal pelvis in analysis the uptake ratio in left-right kidney of hydronephrosis. Because of the work convenience and prompted analysis, the automatic ROI is generally used. But in case of the hydronephrosis study, we should set the manual ROI without expanded renal pelvis for an accurate observation of the uptake ratio of left-right kidney since the radiopharmaceutical uptake in expanded renal pelvis is the remained urine.

  • PDF

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF