• Title/Summary/Keyword: 조명 에너지

Search Result 873, Processing Time 0.034 seconds

Analysis on Fault Current limiting and Recovery Characteristics of Flux-Lock Type Superconducting Fault Current Limiter According to Increase of Applied Voltage (전압증가에 따른 자속구속형 초전도 한류기의 전류제한 및 회복특성 분석)

  • Oh, Kum-Gon;Han, Tae-Hee;Cho, Yong-Sun;Cho, Hyo-Sang;Choi, Myoung-Ho;Han, Young-Hee;Sung, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.107-112
    • /
    • 2007
  • The flux-lock type SFCL consists of transformer with primary and secondary windings connected to a superconducting element in serial. It can be divided into the subtractive and the additive polarity windings according to the winding direction. It could change the fault current limiting characteristics according to the inductance ratio between the coil 1 and coil 2. We investigated the voltage-current characteristics of the flux-lock type SFCL according to the increment of applied voltage. When the applied voltage of the SFCL with the subtractive and the additive polarity windings was increased a initial limiting current ($I_{ini}$) and the quench time of the superconducting element were increased. The recovery time of the superconducting element was increased by increment of applied voltage. Therefore, it was confirmed that recovery characteristics in the flux-lock type SFCL were largely dependent on the consumed energy of a superconducting element because of increment of the consumption power into the superconducting element.

Breakdown Characteristics Assess of Imitation-Air for Distribution Power Facilities (배전급 전력설비를 위한 제조공기의 절연성 평가)

  • Lee, Kwang-Sik;Do, Yeong-Hoei;Choi, Eun-Hyeok;Lee, Chang-Uk;Park, Kwong-Seoo;Kim, Lee-Kook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.114-119
    • /
    • 2008
  • With the improvement of industrial society, the high quality electrical energy, simplification of operation and maintenance, ensuring reliability are being required. We request urgently change a $SF_6$ for an environment friendly gas insulation material. In this paper the experiments of breakdown characteristics by pressure and gap change of Imitation-Air in model GIS(Gas Insulated Switchgear) were described. Also assess of breakdown characteristics about Imitation-Air and $SF_6$. It is considered in this paper that the results are fundamental data for electric insulation design of Distribution Power Facilities which will be studied and developed in the future. The pressure to be confronted to $SF_6$ gas 1[atm] for Distribution Power Facilities is Imitation-Air 3[atm]. And we could make an environment friendly gas insulation material with maintaining dielectric strength by Imitation-Air which generates a lower level of the global warming effect.

Histogram Analysis in Separated Region for Face Contour Extraction under Various Environmental Condition (다양한 환경 조건에서의 얼굴 윤곽선 영역 검출을 위한 분할 영역 히스토그램 분석)

  • Do, Jun-Hyeong;Kim, Keun-Ho;Kim, Jong-Yeol
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Some methods employing the Active Contour Model have been widely used to extract face contour. Their performance, however, depends on the initial position of the model and the coefficients of the energy function which should be reconsidered whenever illumination and environmental condition of an input image is changed. Additionally, the number of points in the contour model should increase drastically in order to extract a fine contour. In this paper, we thus propose a novel approach which extracts face contour by segmenting the face region with threshold values obtained by a histogram analysis technique in the separated region of input image. The proposed method shows good performance under various illumination and environmental condition since it extracts face contour by considering the characteristics of the input image.

Development of bicycle device to strengthen safety (안전 강화를 위한 자전거 장치 개발)

  • Oh, Byung-Wuk
    • Journal of Industrial Convergence
    • /
    • v.17 no.4
    • /
    • pp.125-129
    • /
    • 2019
  • With the growing number of people using bicycle, the number of bicycle accidents also has been increasing. It is said that bicycle accident can be reduced up to 11%~44% when riding a bicycle if LED light is used. The headlight of the bicycle makes exposure effect to the opposite side of bike rider while taillight makes exposure effect to the rear bike rider for improving safety. Bicycle safety device capable of displaying a change of direction by LED is implemented in this study in response to control button signal. This signal makes LED light which is installed in pedal and wheel of bicycle as a module type emitting or flickering during the fixed hour. Bicycle auxiliary device in pedal which is able to improve safety using LED when bikers are riding a bike at night is developed in this study. Bicycle safety device applying wireless communication technology will be expected alternative technology in the future to solve a social problem such as energy, environment, and safety.

High Speed PLC-based Automatic Control System for a Smart LED Streetlight (스마트 LED 가로등을 위한 고속 전력선 통신 기반 자동제어 시스템)

  • Kim, Young-Suk;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.95-102
    • /
    • 2014
  • In this paper, we propose the high speed PLC-based automatic control system for a smart LED streetlight. The proposed the automatic control system were constructed of a power line modem part and monitoring part, streetlight controller part for the high speed communication frequency band and streetlight ballasts characterization and real-time remote control using a high-speed PLC network, and it was designed to meet to lighting grades conditions of KS road lighting standards. The proposed automatic control system were easy monitoring of the power consumption using PC through to the comparison result of the existing streetlight system. As a result, it was confirmed to the possibility of efficient operation for the real-time monitoring and maintenance by induction of reasonable power consumption through to the LED streetlight state checking and remote-control. In addition, we proved to improvement of expected effects for the power cost savings, the energy efficiency, and streetlight differentiation and advanced.

Dimming Control of A Automotive HID Lamp Ballast Using Digital Control Method (디지털제어방식을 이용한 자동차용 고압방전등 안정기의 조광제어)

  • Lee, Jae-Hak;Kim, Yoon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.24-33
    • /
    • 2005
  • This paper presents dimming control system for automotive 35[W] metal halide discharge(MHD) lamp electronic ballast using digital control method. HID system has been becoming increasingly popular due to its superior performance(high luminous efficacy, good color rendering and long life etc.)over the conventional halogen system. However, this lamp demands a highly efficient ballast and very complex control circuitry that can control complex transient state in applying to automotive. Therefore, in this paper, digital control method for the HID lamp ballast is presented for optimal control that can adapt complex transient state, steady state and various environments. In developed dimming system, the system is designed to control the lamp output voltage step by step using microcontroller according to cds sensor. Therefore the designed dimming control system give good driving condition to diver and realize the power control effectively. The results of the proposed system is verified through various simulation results and the experiment results.

The Analysis of Fire Dispersion Characteristics of Vinyl and Rubber Cords Used Indoors (옥내용 비닐코드 및 고무코드의 화재확산특성 분석)

  • Choi, Chung-Seog;Shong, Kil-Mok;Kim, Dong-Ook;Kim, Dong-Woo;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.130-135
    • /
    • 2005
  • The electrical fire frequently happens through careless use such as poor contact, mechanical stress on power cord sets. In this paper, we simulated a wall-model in order to investigate the patterns of fire dispersion on power cord sets which consists of vinyl cord and rubber cord, etc. The fire progress and dispersive patterns were measured by a high speed imaging system(HG-100K, REDLAKE, USA). From the results, the fire pattern of power cord sets was progressed in order of flashover, scattering and disconnection. The short-circuit of the vinyl cords happened easier than the rubber cords by the external flame. In case vinyl cord is disconnected. the fire progress is not observed because the ignition energy decreases. Whereas, the fire progressed continuously in case of the rubber cord.

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

Recommended Practice for o Reasonable Design Demand Factor and Analysis of Power Consumption Characteristics by Loads in Office Buildings (사무소용 빌딩의 부하종별 전력소비특성 분석 및 수용률 기준 정립에 관한 연구)

  • Kim, Se-Dong;Lee, Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.111-118
    • /
    • 2005
  • It is increased electrical energy consumption with the development of intelligence society in the once buildings and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 54 office buildings and 34 electrical design offices. In this dissertation it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimum and thus it was carried the linear and nonlinear regression analysis.

Effect of Filler and Additive on Performance of Cycloalipatic Epoxy Used for Outdoor Insulators (Cycloaliphatic계 에폭시 절연재료의 옥외성능에 미치는 충전재 및 첨가물의 영향)

  • 연복희;박충렬;허창수;심대섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.30-37
    • /
    • 2002
  • This paper reports on the results of weathering test, tracking test and salt-fog test of various kinds of cycloaliphatic epoxy systems. UV irradiation dramatically induced the loss of surface hydrophobicity due to the chain scission attack at the surface under UV irradiation. It could be seen that samples containing an UV absorbent/antioxidant and a silicone oil additive have a good performance in weathering test, while ATH(alumina tri-hydrate) filled ones have high resistance against tracking failure than others. Under salt fog chamber test, specimens mixed with silicone oil are able to suppress leakage current development. It was thought that silicone oil mixed into cycloaliphatic epoxy system could lead to lower the surface energy and to retain hydrophobic properties for a long time, which are desirable for outdoor use.