• Title/Summary/Keyword: 조도측정

Search Result 490, Processing Time 0.033 seconds

Survey on the Current Lighting Level at the Gas Stations and its Analysis on the Illuminance Pattern (주유소 조명 실태와 조도패턴 분석)

  • 주윤석;임종국;여인선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.1-6
    • /
    • 1999
  • This paper investigates the illuminance level at the existing gas statioos and compares the results with the KS and IESNA standards. The IreaSured illuminance level in the pump island area is found to be high up to 3 tirres the recorrnrended value in KS and sorrewhat lower than one in IESNA standard. From this result we coodude that significant degree of energy saving can be possible from prwer maintenance program, and careful coosideration must be paid in the design process. And the KS standard need to be examined more thoroughly against other nation's standards.

  • PDF

Object Position Measuring System using Trilateration Method based on Illuminance of LED (LED의 조도를 기반으로 삼각측량법을 사용한 물체 위치 계측 시스템)

  • Sagong, Byung-Il;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.3
    • /
    • pp.449-455
    • /
    • 2022
  • In this paper, we propose a position measuring system using trilateration based on the illuminance of a light-emitting diode (LED). Three LEDs are located on the ceiling of the virtual space, and each fixed coordinate is inputted to the monitoring program, and Length to the illuminance sensor is drawn through the relational expression of the length and illuminance value from the respective LED. Based on the derived length, the trilateration method is used to find object location information in virtual space. By using the least square equation to minimize the error of the length drawn to trilateration, the error is reduced to the utmost. Unlike the existing indoor positioning system using visible light communication (VLC), the proposed system does not require synchronization between the transmitter and the receiver, so the system can be configured simply.

Evaluation of daylighting performance of bar-type mirror reflector system in tunnel (터널 적용 바형식 반사거울시스템의 채광성능 평가)

  • Lee, Beom-Seok;Joo, Jae-Sung;Jeong, In-Young;Kim, Min-Sung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.93-105
    • /
    • 2012
  • The basic study was preceded for reducing maintenance and power cost of lighting fixture applying daylighting because most of the tunnel lighting depend on the artificial lighting. This study aims to evaluate the daylighting performance of daylighting performance of bar-type mirror reflector system in tunnel. Illuminance and luminance was measured. As a result of horizontal illuminance measurements, it was satisfied in tunnel recommended illuminance (KSA 3703) that total average was 1,170 lx increased 6.5 times more than this system was not used. Also, as a result of evaluating driver's glare on the opposite lane, glare did not occur and the luminance ratio was 3.01 which satisfies the luminance ratio standard 10.

Relationship between Environmental Conditions and the Growth of Ginseng Plant in Field II. Light Intensity under Shading Material and Photosynthesis (인삼포의 환경조건과 인삼생육과의 관계 제2보 일복내 조도의 변화와 포장에서의 광합성)

  • 이성식;김종만;천성기;김요태
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.2
    • /
    • pp.169-174
    • /
    • 1982
  • Light intensities under and above shading material were measured at different layers (upper, middle and lower layers) and lines (lst, 3rd and 5th lines) on clear and cloudy days in S-year-old ginseng plant populations. Rates of photosynthesis and respiration were also measured in field. Light intensities of the 1st lines at upper and lower layers were relatively high as compared with the 3rd and the 5th lines, and there were no remarkable difference between the 3rd and the 5th line. But in middle layer, the light intensity of each line differed considerably. As compared with fair and clear day, the day of clear but much diffuse light showed high light intensity under shading. Relative light intensity was higher on cloudy day than on clear day. There were notable differences of photosynthetic rates among the lines and the rearest lines exhibited the lowest rates. But it was not considered that even the front plants demonstrated the maximum photosynthetic capacity.

  • PDF

Changes of Refractive Errors Caused by Corneal Shape and Pupil Size (각막지형과 동공크기에 의한 굴절교정값의 변화)

  • Noh, Yeon Soo;Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.383-387
    • /
    • 2014
  • Purpose: To investigate the effect of corneal unique shape to changes of refractive full corrections when pupil size changes. Methods: Subjective refraction for monocular full correction was performed to 30 subjects ($23.33{\pm}1.78$ of age, 60 eyes) in two room conditions, 760 lx and 2 lx, respectively. Pupillary diameter was measured in two conditions and the change pattern was analyzed using a peak data of corneal topography. Results: Pupillary diameter was 3.74~4.00 mm in 760 lx and 5.52~5.90 mm in 2 lx. By comparison with refractive data in 760 lx, those data in 2 lx was changed as follows: more (-) spherical power of 17 eyes (28.3%), more (+) spherical power of 10 eyes (17.7%), more (-) cylinderical power of 17 eyes (28.8%), less (-) cylinderical power of 9 eyes (15.3%), and astigmatic axis rotation of 36 eyes (62.1%). From peak data of corneal topography, the changing pattern of two principal meridians was classified into 4 types. Conclusions: Expansion of the corneal refractive surface accompanied with pupillary dilation may be a main factor that effects the changing a values of subjective refraction because of unique corneal shape. Therefore, subjective refraction should be performed under the nearest lighting condition to a main living environment.

Lighting Design of Lecture Room by using Relux (Relux를 이용한 강의실 조명설계)

  • Shin, Yeon-Soo;Eo, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2241_2242
    • /
    • 2009
  • 본 논문은 강의실 조명설계로 2/40W FL${\times}$9와 2/25W LED FL${\times}$12를 Relux 2007를 이용하여 모델링을 통한 시뮬레이션을 측정 하였으며, 두 램프를 비교 분석하여 가장 이상적인 조명기구 및 조도 값을 알아본다. 이 시뮬레이션 결과 2/40W FL${\times}$9의 경우가 2/25W LED FL${\times}$12를 사용했을 때 보다 조도와 균제도가 높게 측정되었고, 소비전력은 2/25W LED FL${\times}$12 매입했을 때가 낮게 나왔다. 금후 LED 형광등 조명설계에 있어서 도움을 줄 수 있을 것으로 기대된다.

  • PDF

Effect of Reynolds Number on the Flow Characteristics of a Control Valve (제어밸브 유량특성에 레이놀즈 수가 미치는 영향)

  • Jung, Taekyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.995-999
    • /
    • 2017
  • The factors affecting the flow coefficient of a control valve were identified and analyzed. The flow coefficient of a control valve are affected by not only Reynolds Number but also the figure and the roughness of the inlet/outlet pipes. Therefore, the flow coefficient is not a constant value. For the purpose of use in the system such as LRE, requiring the exact flow-coefficient of a control valve, the flow-coefficient should be measured under similar Reynolds Number using the inlet and outlet pipes which have the same figure and roughness with a real system.

  • PDF

Prediction of River Discharge by Using Mean Velocity Equation (평균유속공식을 활용한 하천 유량예측)

  • Choo, Tai-Ho;Chae, Soo-Kwon;Yoon, Hyeon-Cheol;Song, Jung-Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.135-139
    • /
    • 2012
  • 하천에서의 정확한 유량 산정은 하천의 설계 및 운영 유지에 매우 중요한 요소이다. 현재 하천의 유량 생산은 수위-유량관계곡선을 통하여 이루어지고 있다. 수위-유량관계곡선법은 측정된 수위와 유량자료의 관계를 바탕으로 홍수기 때의 유량을 회귀 추정법으로 예측하여 사용하는 방법이다. 비교적 간편하게, 특히 측정이 어려운 홍수기 때의 유량을 예측하여 사용할 수 있다는 장점을 가지고 있지만 수위와 유량만의 관계를 사용하므로 하천의 수리학적 특성을 반영하기 곤란하기 때문에 기본적으로 개선되어야 할 사항이 있다. 따라서, 본 연구에서는 하천유량을 예측하는 새로운 방법론의 하나로 KSCE에 기 게재된 Choo 등(2011)의 방법에 따라, 개수로에서 널리 사용되어 오고 있는 Manning식과 Chezy식을 활용하여 하천의 전체적인 특성을 잘 반영하는 특성조도계수 n과 특성Chezy계수 C를 사용하여 하천의 유량을 예측하였다. 실험실 직선수로에서 측정된 정류 자료와 객관성 있는 해외 하천 유량측정 자료를 사용하여 증명하였고 결정계수 0.8 정도 수준의 높은 정확성을 보여주는 성과를 나타내었다. 따라서 본 연구결과를 통해 하천의 수리학적 특성을 반영하면서도 간단하게 유량을 예측할 수 있는 방법으로 실무에서 간편하게 활용될 수 있을 것으로 기대한다.

  • PDF

The Changes of VEP Values According to the Luminance Conditions and Refractive Errors in Normal Persons (정상인에서 조도와 굴절이상도에 따른 시유발전위 검사 값의 변화)

  • Leem, Hyun Sung;Lee, Koon Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.111-117
    • /
    • 2007
  • The visual evoke potential(VEP) is the effective method to diagnose and treat the amblyopia or to check the infants visual ability. In order to evaluate the changes of P100 latencies and amplitudes of VEP by intensity of illumination and refractive errors, we measured latencies and amplitudes of 41 normal adults (20/20 VA) who have no ocular diseases and neurologic diseases. The results were as follows: In the scotopic condition, the latencies were N75$75.83{\pm}3.69$ msec, P100$103.48{\pm}5.34$ msec, the P100 amplitude was $14.86{\pm}2.43$ msec, and in the photopic condition, the latencies were N75$76.71{\pm}3.11$ msec, P100$107.26{\pm}5.54$ msec and the P100 amplitude was $10.35{\pm}1.75$ msec. The latencies and amplitudes of P100 in the photopic condition had higher values than those in the scotopic condition and the measures were significantly different between the scotopic and photopic condition (p<0.01). The P100 latencies were delayed both in the scotopic and photopic condition with the refractive errors and those measures were delayed more than in the photopic condition. The P100 amplitudes in the induced myopic and hyperopic conditionsreduced than in the emmetopes in both illumination conditions. The P100 latencies and amplitudes in emmetropes showed a correlation with the induced myopic conditions in the scotopic condition. Those results showed that P100 latencies and amplitudes are dependent on the illumination conditions and refractive errors. And we suggest that those results would be useful to determine and evaluate the normal range for the person considering patients' refractive errors and illumination of the test room.

  • PDF

Effects of Variation of Illumination on Visual Function Factors (조도변화가 시기능 성분에 미치는 영향)

  • Kim, Da-Young;Kim, Sang-Yeob;Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.195-200
    • /
    • 2015
  • Purpose: This study was performed in order to figure out the influence of illumination on visual function. Methods: 40 adults (male 21, female 19) of average age $23.93{\pm}1.59$ years were participated in this study. The test chart surface illumination was adjusted to 5, 50, 200, 500 and 800 lx, and then amplitude of accommodation, near point of convergence, far and near distance phoria, far and near distance fusional vergence, relative accommodation, and accommodation lag were measured at each illumination condition. Results: As illumination intensity of test chart was reduced, amplitude of accommodation was significantly decreased (p<0.05), accommodation lag was also decreased, near point of convergence was receded, and horizontal phoria showed a tendency of esodeviation. In the case of negative fusional vergence, with reduction of illumination intensity, the break point and the recovery point were decreased but in the case of positive fusional vergence, the break point was increased. The negative and positive relative accommodation were significantly decreased (p<0.05) with reduction of illumination intensity. Conclusions: In clinical practice, visual functional test should be performed under condition of adequate illumination level through patient's living environment and job.