• Title/Summary/Keyword: 조도

Search Result 29,629, Processing Time 0.058 seconds

Prediction of Reduction Rates of Daylight Illuminance for Blind Conditions in a Small Office (소규모 사무실의 블라인드 조건에 따른 주광조도 감소비율 예측)

  • Gu, Renyan
    • Land and Housing Review
    • /
    • v.12 no.2
    • /
    • pp.79-89
    • /
    • 2021
  • This simulation based study analyzed the horizontal daylight distribution on the floor and ceiling of a small office space based on window orientations and interior window blind positions. South and north facing windows were each tested without window blinds and with window blinds at 45° and 180° (horizontal). The study showed that the illuminance value was highest 1m from the window. On the floor and ceiling, the difference in illuminance value was the greatest and least in December and June, respectively. The indoor illuminance value was highest when there was no window blind and under south-facing conditions. The greatest illuminance difference occurred between window blinds positioned at 45° and 180°. Under north-facing conditions, windows without blinds or with blinds at 45° had the least impact on indoor illuminance with illuminance being more evenly distributed.

Efficient Record Filtering In-network Join Strategy using Bit-Vector in Sensor Networks (센서 네트워크에서 비트 벡터를 이용한 효율적인 레코드 필터링 인-네트워크 조인 전략)

  • Song, Im-Young;Kim, Kyung-Chang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.27-36
    • /
    • 2010
  • The paper proposes RFB(Record Filtering using Bit-vector) join algorithm, an in-network strategy that uses bit-vector to drastically reduce the size of data and hence the communication cost. In addition, by eliminating data not involved in join result prior to actual join, communication cost can be minimized since not all data need to be moved to the join nodes. The simulation result shows that the proposed RFB algorithm significantly reduces the number of bytes to be moved to join nodes compared to the popular synopsis join(SNJ) algorithm.

A Study on Variation Character of Roughness Coefficient by Discharge (유량에 따른 조도계수의 변동특성에 관한 연구)

  • Park, Sang-Woo;Lee, Sin-Jae;Jeong, Ha-Ok;Park, Yang-Rae;Kim, Myoung-Su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1651-1655
    • /
    • 2006
  • 일반적인 하천에서 이 치수를 위한 하천 구조물설계를 위해서는 흐름해석이 매우 중요한 작업 중 하나이다. 하천의 흐름해석은 주어진 유량에 대해 등류 또는 부등류, 부정류 계산을 통하여 해석을 하게 되는데, 이때 조도계수는 매우 중요한 매개변수이며, 조도계수에 의해 흐름해석의 결과가 크게 좌우된다. 이러한 조도계수는 어느 특정의 확정적인 요소에 의해 결정되어지지 않고, 복합적인 요소에 의해 결정되어지며, 특히, 유량에 대해 가변성을 갖는다. 본 연구에서는 조도계수의 유량에 대한 가변적인 특성을 분석하고자, 각각 다른 하상경사를 가지는 하천들에 대해 조도계수를 산정하였다. 그 결과, 조도계수는 유량에 대해 가변성을 갖는 것을 확인할 수 있었다. 그리고 하상경사가 완만한 하천일수록 유량에 대한 조도계수의 가변성이 크게 나타났으며, 하상경사가 급할수록 유량에 대한 조도계수의 가변성이 적게 나타나는 결과를 도출하여 유량에 대한 조도계수의 가변성이 하상경사에 민감하게 반응하는 것을 확인할 수 있었다.

  • PDF

Experimental Study on the Material Properties of Unreinforced Masonry Considering Earthquake Load (지진하중을 고려한 비보강 조적조의 재료특성 평가에 관한 실험연구)

  • 김희철;김관중;박진호;홍원기
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.93-101
    • /
    • 2001
  • 본 논문은 국내의 비보강 조적조에 대해 내진성능을 조사하기 위하여 재료측성 평가를 위한 실험연구를 수행하였다. 실험결과를 바탕으로 조적용 모르터의 압축강도식을 제안하였다. 또한 조적용 모르터의 배합비에 따른 조적조 프리즘의 압축강도 특성을 비교하였다. 조적조 프리즘의 압축강도로써 조적조의 탄성계수를 구할 수 있는 약산식을 제시하였으며, 약산식을 사인장 조적조 실험을 통하여 구한 전단탄성계수값과 비교하여 볼 때 타당성을 가지고 있다고 판단된다. 실험결과로써 나온 재료특성 값을 바탕으로 2층 조적조 다세대 주택에 대한 유사동적해석을 수행하였다. 해석결과로 얻은 전단응력과 전단파괴가 나타난 사인장 조적조의 허용전단응력은 유사한 것으로 확인되었다.

  • PDF

Evaluation of surface roughness using phase-measuring interferometer for a few ten ${\AA}$ and sub ${\AA}$-rough substrates (위상측정 간섭계를 이용한 수십 ${\AA}$급 및 sub ${\AA}$급 반사경 기판 조도 평가)

  • 조민식;정태호;오문수
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.4
    • /
    • pp.283-288
    • /
    • 1999
  • We investigated the characteristics of surface roughness evaluation using phase-measuring interferometer for a few ten $\AA$ and sub $\AA$-rough substrates. The influence of phase averaging and intensity averaging on the roughness measurement by phase measuring interferometer was investigated and the optimal number of phase and intensity averaging for the least measurement error was searched. For a few ten $\AA$-rough sample, roughness value did not depend so much on the data averaging. Whereas, measurement error for sub $\AA$-rough sample was significantly improved as the number of phase and intensity averaging increased. At the phase averaging of 30 and the intensity averaging of 20, roughness value that measurement error was minimized was obtained, and it was in good agreement with that by optical heterodyne interferometer. Roughness measurement at the optimal data averaging showed also good repeatability error less than 0.01$\AA$.

  • PDF

The Survey on the Design Standard for the Illumination Level (건물의 기준조도 설정에 관한 연구)

  • 지철근;강원구;김창섭
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.2 no.3
    • /
    • pp.59-66
    • /
    • 1988
  • 본 연구는 우리나라의 조도실태, 경제적 여건 그리고 문화적 여건을 고려하여 우리 나라 자체의 기준 조도의 설정을 목적으로 하고 있다. 이러한 기준 조도의 설정을 위하여 독서(실재) 작업 실험과 말소작업실험의 두가지 실험 방법을 이용하고자 한다. 실제 작업을 통하여 우리나라 국민들의 조도 수준에 대한 만족도를 구하고 말소 작업을 통하여 생산성 향상율과 조도와의 상관관계를 구하여 기준 조도를 설정한다. 이러한 방법에 의하여 구한 기준 조도는 우리나라 현행 관련법규의 개정을 위하여 활용되어야 한다.

  • PDF

Investigation Research on Illuminance/Luminance Ratio Appropriateness Applied in Road Lighting (도로조명에 적용되는 조도/휘도비의 적정성 조사 연구)

  • Lee, Sang-Jin;Kim, Ki-Hoon;Han, Jong-Sung;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.217-222
    • /
    • 2002
  • 노면 반사특성에 관한 연구와 함께 국내에서 도로조명 설계시 적용하는 조도 휘도 환산계수에 관한 연구는, 휘도가 기준이 되는 도로 조명을 설계하는 데에 있어서 매우 중요하다. 현재 조도 휘도 환산계수를 이용하여 설계한 도로조명이 적정하게 유지되고 있는지 알아내기 위하여 실제 도로에서의 조도 및 휘도 분포를 측정하고 조도휘도 환산계수를 계산하였다.

  • PDF

Influence of Light Intensity on Plug Establishment of Zoysia-82, Chewings fescue and Red fescue (Zoysia-82, Highlight Chewings fescue 및 Pennlawn Red fescue의 plugging에 대(對)한 조도(照度)의 영향(影響))

  • Kim, In Seob;Kim, Dal Ung
    • Current Research on Agriculture and Life Sciences
    • /
    • v.6
    • /
    • pp.19-24
    • /
    • 1988
  • The present experiment was undertaken to study the influence of light intensity on plug establishment of zoysia-82, chewings fescue and red fescue. The results obtained are summarized as follows : In chewings fescue and zoysia-82, plant height and leaf length were increased and leaf width was decreased by reducing light intensity. But in red fescue, plant height and leaf length measured at 90 and 120 days after plugging under 9% of incident light were shorter than those under 30% of incident light. Percent ground cover was decreased by reducing light intensity in chewings fescue, red fescue and zoysia-82. Each part of dry weight in three species was getting lighter by reducing light intensity. Decrease of light intensity in zoysia-82 causes increasing chlorophyll a, b, and total chlorophyll content. But red fescue and chewings fescue had the most plentiful chlorophyll under 30% of incident light. Chewings fescue and red fescue had the lowest concentration of chlorophyll a/b under natural light intensity. But zoysia-82 had the lowest concentration of chlorophyll a/b under 30% of incident light. Tillering number of chewings fescue and red fescue was decreased by reducing light intensity. Internode length of zoysia-82 was longer in the order of : 1) 30% of incident light, 2) natural light, 3) 9% of incident light. And internode diameter was decreased by reducing light intensity.

  • PDF

포장과 법률 - 유독물 등의 분류기준 및 표시방법에 관한 규정

  • (사)한국포장협회
    • The monthly packaging world
    • /
    • s.240
    • /
    • pp.109-119
    • /
    • 2013
  • 국립환경과학원은 유해화학물질 관리법 제11조부터 제13조까지 및 제29조, 동법 시행규칙 제6조 제8조 제9조 제28조에 따른 "유독물 등의 분류기준 및 표시방법에 관한 규정"(국립환경과학원고시 제2012-45호, 2012.12.11)을 개정 고시했다. 본 고에서는 주요 내용에 대해 살펴보도록 한다.

  • PDF

A Study on the emergency and repairing AC/DC combination lamp (AC/DC 겸용 비상 및 복구등에 관한 연구)

  • An, Youn-Ki;Choi, Hong-Kyoo;Choi, June-Young;Lee, Jung-Youl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.19-25
    • /
    • 2009
  • The Study is for improvement of power plant equipment environment. Emergency lamp already installed In transformer substations has weak Illuminance. Because emergency battery is limited and incandescent electric lamps installed has low intensity of illumination and bad efficiency. It is too dark to operate many types of equipment in work Therefore this paper proposes that we use fluorescent lamp instead of incandescent electric lamp and change the old illumination standard for evident standard from the can coup with accident rapidly.

  • PDF