• Title/Summary/Keyword: 제진장치

Search Result 94, Processing Time 0.026 seconds

Characteristic of Damping Curve for the Directional System of Magnetic Compass (자기컴퍼스 방위지시부의 제진특성)

  • An, Yeong-Hwa;Jeong, Gong-Heun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.1
    • /
    • pp.28-34
    • /
    • 1985
  • This paper describes that the characteristic of movement and the performance of the directional system of the liquid magnetic compass analyze and investigate in the kinds of compass and the coefficient of viscosity of the liquid of compass, which the horizontal magnetic field of the geo-magnetic is varied from the equator to the polar region (0.39 gauss-0.03 gauss) by use of apparatus generating artificial magnetic fields. The results are as follows; 1. It is confirmed that the measured values and the calculated values on the characteristic of damping curve by the type of compass and coefficient of viscosity has almost agree with one another. 2. As the horizontal magnetic force geo-magnetic field approaches around the equator (0.39 gauss), the horizontal magnetic field get near the polar region (0.03 gauss), its period is to be longer and the compass card prove not to be more stabilized. 3. The coefficient of viscosity of the liquid in the A, B, C, D and E compasses used in the experiment is estimated 0.03 poises, 0.02 poises, 0.02 poises, 0.015 poises and 0.048 poises respectively by computer simulation.

  • PDF

Seismic Performance Improvement of Base Isolated Buildings using Smart Passive Control System (스마트 수동 제어 시스템을 이용한 면진 건물의 내진 성능 개선)

  • Jung, Hyung-Jo;Jung, Chan-Kuk;Choi, Kang-Min;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.37-46
    • /
    • 2006
  • In this study, the efficacy of the newly developed smart passive control system to improve seismic performance of base isolated building structures is numerically verified. The smart passive control system consists of a magnetorheological (MR) damper and an electromagnetic induction (EMI) part. The damping characteristics of an MR damper can be controlled by the current generated in an EMI part according to the Faraday's law of electromagnetic induction. An EMI part consisting of a permanent magnet and a solenoid coil could substitute a control system including sensors, a controller and an external power supply in a conventional smart control system. The benchmark control problem for a base isolated building presented by the american society of civil engineers is considered for numerical simulation. The control performance of the smart passive control system is compared to that of the conventional smart control system using MR dampers. It is demonstrated from the numerical simulation results that the smart passive control system is useful to improve the seismic performance of base isolated buildings.

Experimental Evaluation on the Vibration Control Effect of Tuned Liquid Damper with Embossment (벽면 요철형 동조액체댐퍼의 진동제어성능에 관한 실험적 평가)

  • Ju, Young Kyu;Kim, Dae Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.765-772
    • /
    • 2002
  • Many researchers have studied several vibration control devices such as TMD, TLD, and VED to reduce the acceleration level for tall buildings. Advantages of TLD (tuned liquid damper) include easy installation, low cost, and less maintenance. However, the dynamic characteristics of TLD must be verified by experiment and analysis due to the difficulties in evaluating the characteristics of water sloshing. In this study, free vibration and dynamic excitation experiments of structure with TLD were conducted to verify vibration control force of the proposed TLD for high-rise building. The parameters were mass ratio of water to structure, number of damping nets, and aspect ratio. From the test results, the responses of structure with water tank were observed to be smaller than those of structure alone. Furthermore, better damping effect could be achieved with larger mass ratio, more damping nets, and larger aspect ratio. However, in the case of water tank with no damping net, little damping effect was obtained.

Performance and Manufacture of the Apparatus Generating Artificial Magnetic Field of 3-axis Type (3축형 인공자장발생장치의 제작과 성능에 관한 연구)

  • 이유원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.181-188
    • /
    • 2003
  • The objects of this study were to discuss the performance of its using magnetic compass and to do a trial manufacture of the apparatus generating artificial magnetic field of 3-axis type to assess the performance of compass using terrestrial magnetism in the various magnetic field. The results obtained were summarized as follows: The magnetic field of each axis showed the linearly increase in accordance with the increase of electrical current. Average range difference between measured and calculated values was 0.33∼1.93μT and there were no big difference. The magnitude and direction of magnetic field showed some change in the edge of Helmholtz coil, but it appeared to stabilize in the center. In the horizontal magnetic force of 0.30gauss and 0.40gauss, the measured and calculated values of the damping characteristic of magnetic compass showed a good agreement. However, the confidence level was low at the horizontal magnetic force of 0.50gauss.

An Evaluation of the Dampers for the Drift Control in Resident Tall Building (초고층 주거형 건축물의 횡변위 제어를 위한 제진장치의 적용성 평가)

  • Park, Ji-Hyeong;Kim, Tae-Ho;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.499-504
    • /
    • 2008
  • Recently, the problem controlling lateral drift is important in tall buildings for improvement in economic efficiency and habitability. But, the Outrigger System, general used for tall building in Korea, has weak points with the occupancy of special space and the long duration of works. The dampers are applied to actively control building's response by earthquake and wind load in these days. Accordingly, we analyze the effect of the drift control using various dampers to substitute for the Outrigger System as the efficient system in tall buildings.

  • PDF

An Experimental Study and the Design of the Rubber Laminated Lead Damper (탄성체 적층 납삽입 제진장치의 설계 및 특성시험)

  • Lee, Wan-Ha;Park, Jin-Young;Park, Jung-Woo;Kim, Ki-Man;Park, Kun-Nok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.165-170
    • /
    • 2011
  • A large number of seismic isolation systems have been developed since the early 1970s. They are basically a combination of elastomeric bearing and energy dissipators. The investigation described in this paper analyzes shear property and the frequency dependence of Lead Rubber Damper(LRD). Lead Rubber Damper is similar in shape and performance property to Lead Rubber Bearing. Experimental condition ranges from 20 to 200% in share strain and from 0.1 to 1.0Hz in frequency. When the shear strain is increased, effective stiffness and damping ratio are decreased. When the frequency is increased, change of the behavior characteristic is subtle.

  • PDF

Application of Fe-Mn Damping Alloy for Divided Spherical Bearing in Bridge (Fe-Mn 제진금속을 적용한 교량용 교좌장치)

  • Han, Dong-Woon;Kim, Tai-Hoon;Back, Jin-Hyun;Kim, Jung-Chul;Baik, Seung-Han;Yoo, Mun-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1024-1028
    • /
    • 2006
  • The Fe-Mn damping Alloys which combine a high damping capacity with good mechanical properties can provide attractive technical and economic solutions to problems involving fatigue, noise and vibration. This study is aimed at finding its applicability to divided spherical bearing in bridge. The results obtained are summarized as follows : 1) The specific damping capacity of the Fe-Mn damping alloy is superior to that of SM490B. 2) The divided spherical bearing manufactured Fe-Mn damping alloy passes the load test to confirm applicability of that in bridge.

  • PDF

Closed Form Formulas for Equivalent Damping Ratios of a Linear Structure Equipped with Damping Devices (제진장치가 설치된 구조물의 등가감쇠비)

  • Hwang, Jae-Seung;Lee, Sang-Hyun;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.370-377
    • /
    • 2002
  • Hwang et al (2001) proposed a new method for an evaluation of equivalent damping ratios of a linear structure with linear or nonlinear damping devices. This procedure has a disadvantage that it requires time history analysis for the whole system including damping devices, which may be troublesome for practical application. To tackle this problem closed form formulas for equivalent damping ratios are proposed in this study. It is assumed that the responses of MDOF system can be reproduced by an equivalent SDOF system which vibrates in a fundamental mode. The numerical analyses of a ten-story building equipped with linear viscous damper or active mass damper or friction damper show the effectiveness of equivalent SDOF model and closed form formulas.

  • PDF

Application of TMD to Reduce Seismic Response of Arch Structure (아치구조물의 지진응답 저감을 위한 TMD의 적용)

  • Kim, Gee-Cheol;Kang, Joo-Won;Kim, Hyun-Su
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.27-30
    • /
    • 2010
  • TMD(Tuned Mass Damper)는 대표적인 제진장치로서 주로 고층건물, 교량 및 스타디움의 객석 등의 진동제어에 이용되고 있다. 그러나 대공간구조물과 같이 면외 방향의 강성이 매우 작은 구조물에 대한 TMD 적용에 대한 연구는 거의 전무한 실정이다. 본 연구에서는 아치구조물의 진동에 대한 TMD의 제어 성능을 TMD의 설치위치 및 거동방향에 따라서 비교분석하였다. 아치구조물은 수평지진동에 대해서는 역대칭모드인 1차 모드가 지배적이며, 연직지진동에 대해서는 대칭모드인 2차 모드가 지배적인 진동응답을 보이고 있다. 따라서 아치구조물의 효율적인 진동응답제어를 위해서는 진동모드가 탁월한 위치에 TMD를 설치하는 것이 합리적이다. 그리고 수평지진동 및 수직지진동에 대하여 TMD가 수평방향으로 거동하도록 하는 것보다 연직방향으로 움직이도록 설치하는 것이 아치구조물의 진동제어에 있어서 매우 효과적인 것으로 나타났다.

  • PDF