• Title/Summary/Keyword: 제웅

Search Result 28, Processing Time 0.028 seconds

Comparison of Image Quality of the Amorphous Silicon DR System and the Film-screen Systems (비정질 실리콘 디지털 방사선 촬영기와 X-ray film과의 영상질 비교 평가)

  • Youn, Je-Woong;Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Shin, Kyung-Sub;Mun, In-K.;Kim, Hong-Kwon;Han, Yong-Woo;Nam, Seung-Bae
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.161-170
    • /
    • 1999
  • System performances in terms of image quality between an amorphous silicon DR system and a conventional film-screen system were evaluated. Various aspects of image quality MTF (modulation transfer function), NPS (noise power spectrum), SNR(signal-to-noise ratio) and contrast were measured and calculated. The MTF of the DR system was comparable to the film-screen systems. The noise was mainly dominated by the quantum mottle in both systems and the electronic noise was found in the DR system. The contrast of the DR system was better than the film-screen systems by virtue of high sensitivity and image processing. Compared to the film-screen systems in general radiography, the DR system had similar resolution and showed better contrast with the same exposure condition after contrast manipulation. The results of this study provide some useful information about the performance of the DR system in connection with medical applications.

  • PDF

Evaluation of Parthenocarpic Fruit Set in Lycopersicon esculentum Mill (토마토의 단위결과성 재료 탐색)

  • Kim, Ji-Kwang;Kim, Jin-Han;Yoon, Wha-Mo;Park, Kwon-Seo;Park, In-Hee;Im, Um-Ryang
    • The Journal of Natural Sciences
    • /
    • v.11 no.1
    • /
    • pp.99-103
    • /
    • 1999
  • This study was carried out to use as the basic data for breeding by evaluating parthenocarpy with 12 tomato lines and 17 allied species. Fruit set of open pollination plots was over 90% in 11 lines(CLN430-85-13-5 etc), 9.1-50% in 10 lines(LA1306 etc.), and the rest no fruit set. Fruit set after emasculation resulted highly 51.4% in CLN431-85-13-12, 53.9% in CLN425-130-8-1, 66.7% in CLN435-185-4-9, and 72.2% in Ventura, respectively. But fruit set in other tomato lines resulted under 50% and 17 allied species(LA1306 etc) resulted no effect of fruit set. Fruits other emasculation had no seeds and fruits after open pollination had 10-70 seeds per fruit. This result of this work showed that 3 lines, CLN435-185-4-9, CLN425-130-8-1, and CLN431-85-13-12, resulted in good effectiveness on the evaluation of parthenocarpy in tomatoes.

  • PDF

Development of Respiratory Signal Analysis Program for Accurate Phase Reassignment in 4D CT Reconstruction (4D CT 영상 재구성 시 정확한 위상 변환을 위한 호흡 신호 분석 프로그램 개발)

  • Park, Hae-Jin;Jung, Won-Gyun;Yoon, Jai-Woong;Song, Ju-Young;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.241-246
    • /
    • 2008
  • Patient's respiration can have an effect on movement of tumor range and peripheral organs. Therefore, the respiratory signal was acquired by relation between external markers and movement of patient's abdomen during radiational therapy in order to minimize the effect of respiration. Based on this technique, many studies of rational therapy to irradiate at particular part of stable respiratory signals have executed and they have been clinically applied. Nevertheless, the phase-based method is preferred to the amplitude-based method for the rational therapy related to respiration. Because stabilization of the respiratory signal are limited. In this study, a in-house respiratory signal analysis program was developed for the phase reassignment and the analysis of the irregular respiratory signals. Various irregular respiratory patterns was obtained from clinical experimental volunteers. After then, the in-house program analyzed the factors affecting to phase assignment which is directly related to irradiated sector. Subsequently, accuracy of phase assignment was improved with removement of irregular signals by self-developed algorithm. This study is considered to be useful for not only image reconstruction and elevation of irradiating accuracy through phase assignment of RPM system but also analysis of respiratory signals. Moreover, development of 4D CT image is planed with phantom researches or clinical experiments based on this program.

  • PDF

Development of Respiratory Training System Using Individual Characteristic Guiding Waveform (환자고유의 호흡 패턴을 적용한 호흡 연습장치 개발 및 유용성 평가)

  • Kang, Seong-Hee;Yoon, Jai-Woong;Kim, Tae-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • The purpose of this study was to develop the respiratory training system using individual characteristic guiding waveform to reduce the impact of respiratory motion that causes artifact in radiotherapy. In order to evaluate the improvement of respiratory regularity, 5 volunteers were included and their respiratory signals were acquired using the in-house developed belt-type sensor. Respiratory training system needs 10 free breathing cycles of each volunteer to make individual characteristic guiding waveform based on Fourier series and it guides patient's next breathing. For each volunteer, free breathing and guided breathing which uses individual characteristic guiding waveform were performed to acquire the respiratory cycles for 3 min. The root mean square error (RMSE) was computed to analyze improvement of respiratory regularity in period and displacement. It was found that respiratory regularity was improved by using respiratory training system. RMSE of guided breathing decreased up to 40% in displacement and 76% in period compared with free breathing. In conclusion, since the guiding waveform was easy to follow for the volunteers, the respiratory regularity was significantly improved by using in-house developed respiratory training system. So it would be helpful to improve accuracy and efficiency during 4D-RT, 4D-CT.

Identification of True Full Sib Progenies of Japanese Red Pine via cpSSR Haplotyping (cpSSR haplotype에 근거한 소나무 전형매차대목(全兄妹次代木) 검정(檢定))

  • Hong, Yong-Pyo;Kwon, Hae-Yun;Han, Sang-Urk;Choi, Wan-Yong;Kim, Yong-Yul
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.3 s.160
    • /
    • pp.178-182
    • /
    • 2005
  • To identify the seedlings from controlled pollination between one paternal tree and three maternal trees of Japanese red pine, cpSSR markers of the paternally inherited haploid genome were analyzed in two year old 114 seedlings of full sib families. Individual specific DNA fingerprint like haplotypes of the parental trees were determined by PCR with three cpSSR primers. Haplotypes of the 114 seedlings were also identified by PCR with the same primers. On the basis of the comparison of cpDNA haplotypes of the 114 seedlings with those of the parental trees, 14 seedlings revealed to have distinguished haplotypes from those of the paternal tree. It was tentatively concluded that they were generated via pollination with the non-paternal trees. A seedling of Gangwon30 revealing non-paternal haplotype might have been generated via self pollination with the pollens of maternal tree through improper emasculation or contamination during artificial pollination. DNA fingerprint like cpSSR profiles observed in this study could be successfully applied to the various plant forensic analyses, such as identification of siblings of individual trees, asexually reproduced ramets of a specific clone, vegetatively propagated individuals via tissue culture, and pure full sib progenies.

Effects of Plant Growth Regulators on Haploid Production of Wheat (밀 반수체 생산에서 식물생장조절제의 영향)

  • Kim, Young Jin;Lee, Kwang Won;Kim, Hag Sin;Cheong, Young Keun;Park, Kwang Geun;Kim, Kee Jong
    • Korean Journal of Breeding Science
    • /
    • v.43 no.1
    • /
    • pp.50-55
    • /
    • 2011
  • The introduction of doubled haploid (DH) approach into breeding programs has reduced the times and population sizes required for the production of pure lines. We carried out the experiment for development on effective method of producing haploid in wheat. Emasculated spikelets of wheat were pollinated with maize pollen and cultured in the solution containing 40 g/L sucrose and 2,4-D, NAA, 2,4,5-T and dicamba 24 h after pollination, and then incubated until embryo rescue. Fourteen to sixteen days after pollination, the embryos are excised and cultured in half-strength MS basal medium supplemented with 20 g/L sucrose and 1 mg/L NAA. The type of plant growth regulators was found to be most significant in production of haploid plants. The application of synthetic auxins to pollinated florets, stimulates haploid embryo development to a stage where the embryos can be rescued onto nutrient media. The percentage of seeded florets was significantly affected by 100 mg/L 2,4-D, 150 mg/L 2,4,5-T and 50 mg/L dicamba. The percentage of embryos formed was significantly increased by treatment with 2,4-D and 2,4,5-T at 100 mg/L, and dicamba at 50 mg/L, but the treatments with 150 mg/L 2,4-D inhibited embryo development and plant regeneration. The optimum application time of plant growth regulators was 24 hrs after pollination.

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

Convolution-Superposition Based IMRT Plan Study for the PTV Containing the Air Region: A Prostate Cancer Case (Convolution-Superposition 알고리즘을 이용한 치료계획시스템에서 공기가 포함된 표적체적에 대한 IMRT 플랜: 전립선 케이스)

  • Kang, Sei-Kwon;Yoon, Jai-Woong;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.271-277
    • /
    • 2013
  • In prostate IMRT planning, the planning target volume (PTV), extended from a clinical target volume (CTV), often contains an overlap air volume from the rectum, which poses a problem inoptimization and prescription. This study was aimed to establish a planning method for such a case. There can be three options in which volume should be considered the target during optimization process; PTV including the air volume of air density ('airOpt'), PTV including the air volume of density value one, mimicking the tissue material ('density1Opt'), and PTV excluding the air volume ('noAirOpt'). Using 10 MV photon beams, seven field IMRT plans for each target were created with the same parameter condition. For these three cases, DVHs for the PTV, bladder and the rectum were compared. Also, the dose coverage for the CTV and the shifted CTV were evaluated in which the shifted CTV was a copied and translated virtual CTV toward the rectum inside the PTV, thus occupying the initial position of the overlap air volume, simulating the worst condition for the dose coverage in the target. Among the three options, only density1Opt plan gave clinically acceptable result in terms of target coverage and maximum dose. The airOpt plan gave exceedingly higher dose and excessive dose coverage for the target volume whereas noAirOpt plan gave underdose for the shifted CTV. Therefore, for prostate IMRT plan, having an air region in the PTV, density modification of the included air to the value of one, is suggested, prior to optimization and prescription for the PTV. This idea can be equally applied to any cases including the head and neck cancer with the PTV having the overlapped air region. Further study is being under process.