• Title/Summary/Keyword: 제어 방안

Search Result 2,565, Processing Time 0.03 seconds

Effective Coastal Water Quality Management and Marine Environmental Impact Assessment (연안의 효율적 수질관리 방향과 해양환경영향평가)

  • Lee, Dae-In;Eom, Ki-Hyuk;Kim, Gui-Young;Hong, Sok-Jin;Lee, Won-Chan;Jang, Ju-Hyoung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.1
    • /
    • pp.29-37
    • /
    • 2008
  • This study examined principles and techniques of efficient water quality management as well as total coastal pollutant loads and the relevant examples in the advanced countries from the viewpoints of water quality improvement and pollution control in coastal areas. The problems and improvements in an estimation of the current total pollutant loads were also pointed out. In addition, discussion was made on the relationship between total pollutant loads and environmental capacity as well as particulars requiring extensive examination on access to and study on water quality model used as prediction tool for marine environment. Furthermore, this study proposed details of and improvement plans for water quality control to be reflected and absorbed into systems and policies related to coastal water quality. In coastal areas, which are subject to total coastal pollutant loads, it is necessary to calculate pollutant loads reduction and allocation, to propose them in detail in statement in relations to new pollution sources for the corresponding projects or plans in environmental impact assessment and prior environmental review system. Also, in relations to regional plans for coastal management, the local government concerned must focus more on environmental management plan to implement data on pollution sources and pollutant loads flown into sea areas under basic jurisdiction, therefore it is required to actively respond to expansion and introduction of total coastal pollutant loads system in the future. Total coastal pollutant loads system must be expanded and executed by considering characteristics of sea area and changes in the environment of land. For pollution sources in land, the competent authorities in charge of coastal environment will need to initiatively administer supervision, monitoring activities and achieve integration and operation of the related laws by preparing legal bases for management system or adjusting the related laws.

  • PDF

Eco-friendly Control of Whiteflies by Two-Fluid Fogging System with Natural Substances in Greenhouses (이류체 포그시스템 및 천연물을 이용한 친환경적 가루이 방제)

  • Kim, Sung-Eun;Lee, Sang-Don;Lee, Moon-Haeng;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.114-119
    • /
    • 2012
  • We have conducted 4 experiments to develop the most environmental and effective use of the two-fluid fog system to prevent and exterminate whiteflies in tomato cultivation. In particular, these experiments used Vitamini tomatoes grown in stand-alone greenhouses at Buyeo Tomato Experiment Station as subjects. Each experiment utilized the fog system in a different way. The first experiment provided the control group, which was subject to the two-fluid fog system without additional humidity control. In the second experiment, the two-fluid fog system controlled the humidity level to be above 70%. The third and the fourth experiment utilized natural substances, which were 1.5 mg/L of Neem Oil and 2 mg/L of Oleic acid respectively, without additional humidity control. From the first experiment, we could observe that a simple use of the two-fluid fog system decreased the density of whiteflies in the greenhouses. This impact of the fog system on whiteflies was greater in the second experiment. By comparing the first and the second experiment, we concluded that whiteflies are more effectively prevented by maintaining a higher humidity level via the fog system's smaller water droplets that float in the air for longer time than the standard fog system in rather dry condition. In the third and the fourth experiments, the extermination level was 78% and 76.4% respectively, comparing only 53% in the first experiment without the humidity control. Therefore, using the natural substances in addition to the humidity control increases the extermination effectiveness. Considering the similar results from the 3rd and the 4th experiments, Oleic acid has a greater appeal for its lower price. Using the two-fluid fog system to both control the humidity on a daily basis and spray the substances for occasional extermination would reduce labor cost and increase production in an environmental way.

A Study on the Installation of Groyne using Critical Movement Velocity and Limiting Tractive Force (이동한계유속과 한계소류력을 활용한 수제 설치에 관한 연구)

  • Kim, Yeong Sik;Park, Shang Ho;An, Ik Tae;Choo, Yeon Moon
    • Journal of Wetlands Research
    • /
    • v.22 no.3
    • /
    • pp.194-199
    • /
    • 2020
  • Unlike in the past, the world is facing water shortages due to climate change and difficulties in simultaneously managing the risks of flooding. The Four Major Rivers project was carried out with the aim of realizing a powerful nation of water by managing water resources and fostering the water industry, and the construction period was relatively short compared to the unprecedented scale. Therefore, the prediction and analysis of how the river environment changes after the Four Major Rivers Project is insufficient. Currently, part of the construction section of the Four Major Rivers Project is caused by repeated erosion and sedimentation due to the effects of sandification caused by large dredging and flood-time reservoirs, and the head erosion of the tributaries occurs. In order to solve these problems, the riverbed maintenance work was installed, but it resulted in erosion of both sides of the river and the development of new approaches and techniques to keep the river bed stable, such as erosion and excessive sedimentation, is required. The water agent plays a role of securing a certain depth of water for the main stream by concentrating the flow so much in the center and preventing levee erosion by controlling the flow direction and flow velocity. In addition, Groyne products provide various ecological environments by forming a natural form of riverbeds by inducing local erosion and deposition in addition to the protection functions of the river bank and embankment. Therefore, after reviewing the method of determining the shape of the Groyne structure currently in use by utilizing the mobile limit flow rate and marginal reflux force, a new Critical Movement Velocity(${\bar{U}}_d$) and a new resistance coefficient formula considering the mathematical factors applicable to the actual domestic stream were developed and the measures applicable to Groyne installation were proposed.

Monitoring Bacillus cereus and Aerobic Bacteria in Raw Infant Formula and Microbial Quality Control during Manufacturing (영.유아용 식품원료의 Bacillus cereus와 일반세균 모니터링 및 제조공정 중 미생물 품질제어)

  • Jung, Woo-Young;Eom, Joon-Ho;Kim, Byeong-Jo;Ju, In-Sun;Kim, Chang-Soo;Kim, Mi-Ra;Byun, Jung-A;Park, You-Gyoung;Son, Sang-Hyuck;Lee, Eun-Mi;Jung, Rae-Seok;Na, Mi-Ae;Yuk, Dong-Yeon;Gang, Ji-Yeon;Heo, Ok-Sun;Yoon, Min-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.494-501
    • /
    • 2010
  • The purpose of this study was to examine the presence of Bacillus cereus, aerobic bacteria and coliforms in the raw material of infant formulas and investigate the manufacturing process in terms of microbial safety. Among ten kinds of raw infant formula material samples (n=20), Bacillus cereus appeared in two (n=4). Aerobic bacteria were not detected in raw infant formula material or maximum 4.15 log CFU/g. Eleven species of aerobic bacteria were isolated and 76% of them were Sphingomonas paucimobilis, Pseudomonas fluorescens, Rhizobium radiobactor, or Stenotrophomonas maltophilia. A Pearson's correlation analysis revealed that the most influential factors for detecting Bacillus cereus were aerobic bacteria and coliforms. In other words, when the measured values of aerobic bacteria and coliforms were higher, the possibility that Bacillus cereus would appear increased. In a regression model to predict Bacillus cereus, the rate of appearance was correlated with aerobic bacteria and coliforms, and its contribution rate for effectiveness was 86%. Improving microbial quality control by pasteurization, spray dry, popping and extrusion resulted in a decrease in the numbers of Bacillus cereus, aerobic bacteria and coliforms in the raw materials. The results suggest that a hazard analysis and critical control point system might be effective for reducing microbiological contamination.

Survey for contamination and study for reduction of ochratoxin A and aflatoxin in red pepper (고추 중 오크라톡신 A와 아플라톡신의 오염도 조사 및 저감화방안 연구)

  • Kim, Dong-Ho;Jang, Han-Sub;Kim, Yeong-Min;Ahn, Jong-Sung
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.4
    • /
    • pp.299-306
    • /
    • 2009
  • Aflatoxin (AF) and Ochratoxin A (OTA) are carcinogenic and possible carcinogenic mycotoxins respectively produced by Aspergillus spp or Penicillium spp. The study for contamination survey and proposal for reduction of mycotoxin in red pepper were carried out. 192 samples were collected at such various stages and markets as pre/post-harvest stages, internet shopping mall /super-market and small stakeholder mill/geographically indicated company. As only 2 samples were positive for aflatoxin, so contamination rate was 1.04%. In the meanwhile, contamination rate for ochratoxin A was 21.88% and a various amount of OTA was detected in 42 positive samples. 6 samples were found to be contaminated at higher level than $5\;{\mu}gkg^{-1}$ for ochratoxin A, which was established recently as a maximum permissible limit in korea. There was no difference in degree of contamination with regard to cultivation type because any mycotoxin was not found at all in both organically and conventionally grown red pepper. But, there was statistically significant difference in the process of manufacturing. Finished products were OTA-contaminated at a level of $2.32\;{\pm}\;6.54\;{\mu}gkg^{-1}$(mean ${\pm}$ SD), even though OTA was not detected in deep frozen red peppers right after long term storage. And contamination for OTA was a level of $0.33\;{\pm}\;0.91\;{\mu}gkg^{-1}$(mean ${\pm}$ SD) in red paprika powder after uv sterilization, while the contamination for OTA was $2.78\;{\pm}\;4.49\;{\mu}kg^{-1}$(mean ${\pm}$ SD) in non-uv sterilized powder. In addition, our investigation shows that higher OTA contamination occurred in some of famous brand products sold in super-market and domestic products than products collected through on-line shopping or from small stakeholder mills and imported products respectively, however, difference was not statistically significant.

The Method of Multi-screen Service using Scene Composition Technology based on HTML5 (HTML5 기반 장면구성 기술을 통한 멀티스크린 서비스 제공 방법)

  • Jo, Minwoo;Kim, Kyuheon
    • Journal of Broadcast Engineering
    • /
    • v.18 no.6
    • /
    • pp.895-910
    • /
    • 2013
  • Multi-screen service is a service that consumes more than one media in a number of terminals simultaneously or discriminately. This multi-screen service has become useful due to distribute of smart TV and terminals. Also, in case of hybrid broadcasting environment that is convergence of broadcasting and communication environment, it is able to provide various user experience through contents consumed by multiple screens. In hybrid broadcasting environment, scene composition technology can be used as an element technology for multi-screen service. Using scene composition technology, multiple media can be consumed complexly through the specified presentation time and space. Thus, multi-screen service based on the scene composition technology can provide spatial and temporal control and consumption of multiple media by linkage between the terminals. However, existing scene composition technologies are not able to use easily in hybrid broadcasting because of applicable environmental constraints, the difficulty in applying the various terminal and complexity. For this problems, HTML5 can be considered. HTML5 is expected to be applied in various smart terminals commonly, and provides consumption of diverse media. So, in this paper, it proposes the scene composition and multi-screen service technology based on HTML5 that is expected be used in various smart terminals providing hybrid broadcasting environment. For this, it includes the introduction in terms of HTML5 and multi-screen service, the method of providing information related with scene composition and multi-screen service through the extention of elements and attributes in HTML5, media signaling between terminals and the method of synchronization. In addition, the proposed scene composition and multi-screen service technology based on HTML5 was verified through the implementation and experiment.

Analysis of Prognostic Factors in Glioblastoma Multiforme (다형성 교모세포증 환자의 예후인자 분석)

  • Chang Sei Kyung;Suh Chang Ok;Lee Sang Wook;Keum Ki Chang;Kim Gwi Eon;Kim Woo Cheol
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.181-189
    • /
    • 1996
  • Purpose : To find the more effective treatment methods that improving the survival of patients with glioblastoma multiforme(GBM), we analyze the prognostic factors and the outcome of therapy in patients with GBM. Materials and Methods : One hundred twently-one patients with a diagnosis of GBM treated at Severance Hospital between 1973 and 1993 were analyzed for survival with respect to patients characteristics, that is, duration of symptom, age, and Karnofsky performance status, as well as treatment related variables such as extent of surgery and radiotherapy. Results : The median survival time(MST) and 2-year overall survival rate (OSR) of the patients with GBM were 13 months and $20.8\%$, respectively. Duration of symptom, age, Karnofsky performance status(KPS), radiotherapy, and extent of surgical resection were associated with improved survial in a univariate analysis. Patients whose duration of symptom was longer than 3 months, had the 2-year OSR of $47.2\%$(p=0.0082), who were younger than age 50, $32.9\%$(p=0.0003) In patients with a KPS of 80 or higher, the 2-rear OSR was $36.9\%$(p=0.0422). Patients undergoing radiotherapy had the 2-year OSR of $22.9\%$(p=0.0030), and surgical resection of $23.3\%$ (p<0.000). A Cox regression model confirmed a significant correlation of duration of symptom, age, radiotherapy, and extent of surgical resection with survival, excluding KPS(P=0.8823). The 2-year OSR were $22.3\%$ and $19.4\%$, combined with chemotherapy or without, respectively(p=0.6028). The duration of symptom of 3 months or shorter, 50 years of age or older, and undergoing stereotactic biopsy only were considered as risk factors, then patients without any risk factors had the MST of 29 months and 2-year OSR of $53.9\%$ compared to 4 months and $0\%$ for Patients who had all 3 risk factors. Most of all treatment failures occurred in the primary tumor site($80.4\%$). Conclusion : The duration of symptom, age, radiotherapy, and extent of surgical resection were a prognostically significant indeuendent variables. To get a better survival, it seems to be reasonable that the study design which improves the local control rates is warranted.

  • PDF

A Case study and Analysis on the Up-Lift Pressure Treatment Evaluation of Underground Installations for their Efficient Adoption (사례분석을 통한 효율적 상향수압(Up-Lift Pressure) 처리공법 적용방안에 관한연구 - ◯◯ 상업지역 현장사례 중심으로 -)

  • Ko, Ok-Yeol;Kwon, Oh-Chul;Shim, Jae-Kwang;Park, Tae-Eun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.119-129
    • /
    • 2009
  • Building construction trends have been changed dramatically in terms of size and mass. With the need to maximize land usage, there has been an increase in the construction of high-rise buildings. This affects not only the entire construction duration and cost, but also subsequent construction activities, such as work to increase underground facilities and in reclamation land area construction. These types of site conditions require soft ground reinforcement and the proper uplift water pressure treatment. In general, two kinds of methods have been used for uplift water pressure treatment systems. However, there have been some problems arising as the result of a lack of research and analysis on underground construction techniques, and a reliance on experiments over actual survey and analysis of site conditions. This paper focused on the problems of conventional selection procedure, by analyzing drawings and proposing a kind of modeling for a reasonable procedure. The results were applied to OO project as a sample construction case to be verified in this research. The initial plan in the case project was the Rock Anchor System. However, as there were terrible miscalculations of basic site conditions that had an extraordinary influence on the underground water level, such as the site's proximity to the Han-river, it was necessary to change the plan to include apermanent drainage system. This achieved a direct construction cost reduction \ 406,702,000 and a maximum sayings of 4% of operational cost, based on the 50-year building Life Cycle Cost.

Time-Lapse Crosswell Seismic Study to Evaluate the Underground Cavity Filling (지하공동 충전효과 평가를 위한 시차 공대공 탄성파 토모그래피 연구)

  • Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.1
    • /
    • pp.25-30
    • /
    • 1998
  • Time-lapse crosswell seismic data, recorded before and after the cavity filling, showed that the filling increased the velocity at a known cavity zone in an old mine site in Inchon area. The seismic response depicted on the tomogram and in conjunction with the geologic data from drillings imply that the size of the cavity may be either small or filled by debris. In this study, I attempted to evaluate the filling effect by analyzing velocity measured from the time-lapse tomograms. The data acquired by a downhole airgun and 24-channel hydrophone system revealed that there exists measurable amounts of source statics. I presented a methodology to estimate the source statics. The procedure for this method is: 1) examine the source firing-time for each source, and remove the effect of irregular firing time, and 2) estimate the residual statics caused by inaccurate source positioning. This proposed multi-step inversion may reduce high frequency numerical noise and enhance the resolution at the zone of interest. The multi-step inversion with different starting models successfully shows the subtle velocity changes at the small cavity zone. The inversion procedure is: 1) conduct an inversion using regular sized cells, and generate an image of gross velocity structure by applying a 2-D median filter on the resulting tomogram, and 2) construct the starting velocity model by modifying the final velocity model from the first phase. The model was modified so that the zone of interest consists of small-sized grids. The final velocity model developed from the baseline survey was as a starting velocity model on the monitor inversion. Since we expected a velocity change only in the cavity zone, in the monitor inversion, we can significantly reduce the number of model parameters by fixing the model out-side the cavity zone equal to the baseline model.

  • PDF

Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel (복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong;Park, Sangheon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.167-175
    • /
    • 2019
  • To effectively deal with the fire in tunnel which is mostly the vehicle fire, it's more important to suppress the fire at early stage. In urban tunnel, however, accessibility to the scene of fire by the fire fighter is very limited due to severe traffic congestion which causes the difficulty with firefighting activity in timely manner and such a problem would be further worsened in underground road (double-deck tunnel) which has been increasingly extended and deepened. In preparation for the disaster in Korea, the range of life safety facilities for installation is defined based on category of the extension and fire protection referring to risk hazard index which is determined depending on tunnel length and conditions, and particularly to directly deal with the tunnel fire, fire extinguisher, indoor hydrant and sprinkler are designated as the mandatory facilities depending on category. But such fire extinguishing installations are found inappropriate functionally and technically and thus the measure to improve the system needs to be taken. Particularly in a double-deck tunnel which accommodates the traffic in both directions within a single tunnel of which section is divided by intermediate slab, the facility or the system which functions more rapidly and effectively is more than important. This study, thus, is intended to supplement the problems with existing tunnel life safety system (fire extinguishing) and develop the remote-controlled automatic fire extinguishing system which is optimized for a double-deck tunnel. Consequently, the system considering low floor height and extended length as well as indoor hydrant for a wide range of use have been developed together with the performance verification and the process for commercialization before applying to the tunnel is underway now.