• 제목/요약/키워드: 제어부

Search Result 3,559, Processing Time 0.046 seconds

Remote Control Apparatus and Display Remote Control System Comprising the Same (원격 제어 장치 및 이를 포함하는 디스플레이 원격 제어 시스템)

  • Yoon, Yeo-Jun;Park, Dea-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.2 s.46
    • /
    • pp.161-170
    • /
    • 2007
  • This paper is a matter of remote control apparatus and display remote control system comprising the same. The remote controller is a wireless remote pointing device that is included a function of mouse and a function of remote controller for VOD etc. It is assembled a sending signal part to communicate with display device, a image sensor part to capture a scene of front view and a main body. Also, it includes a control part that analyzes the captured image, calculates a relative moving factor that main body is moved by user, and then controls the mouse cursor on the display device. The remote control apparatus is able to capture a seen of front view, to analyze the captured image, and to move a mouse cursor point on the display device as much as it calculated relative moving factor. Therefor it brings don the cost of production by a product desist that is increased user satisfaction. And it, using the patent and the new product desist, will make an epoch in development of the remote control system for Ubiquitous broadcasting industry.

  • PDF

Performance Analysis of BLDC Control Using Full-Order Observer (전차원 관측기를 적용한 BLDC 제어의 성능 분석)

  • Lee, Seunghoon;Lee, Jonghee;Jung, Chanyeong;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.408-409
    • /
    • 2018
  • 본 논문에서는 BLDC와 PI 제어기를 사용하여 전동기의 속도를 제어할 때 전차원 관측기를 적용하여 부하 토크를 추정 및 보상함으로써 속도 리플을 줄일 수 있는지를 검증하고자 하였다. 모터 구동 시에는 필연적으로 부하 토크가 외란으로 포함되며 그로 인해 제어대상인 속도에 리플을 야기하게 된다. 따라서 보다 안정적인 제어를 위해서는 이 외란을 보상해주는 것이 필요한데, 관측기를 이용하면 별도의 장비나 센서 없이 이 부하 토크를 효과적으로 보상해 줄 수 있다.

  • PDF

고속플라이휠 에너지저장기술의 개발현황 및 전망

  • Choe, Sang-Gyu
    • 기계와재료
    • /
    • v.10 no.4 s.38
    • /
    • pp.97-110
    • /
    • 1998
  • 플라이휠 에너지 저장시스템은 입력되는 잉여전기에너지를 플라이휠의 관성을 이용, 회전 운동에너지로 변환하여 저장하고 필요시 전기에너지로 순시에 출력하는 장치로 배터리와 같은 화학적 에너지 저장장치에 대비되는 기계적 에너지 저장방식 (Electro-mechanical Battery)이다. 플라이휠 시스템은 많은 에너지를 단시간에 저장하고 이를 순발적으로 활용할 수 있는 고효율, 장수명, 무공해의 청정 에너지저장/재생장치로 선진국에서는 무공해 교통수단(전기자동차 등)의 차세대 보조 동력원을 비롯한 각종 민수용, 국방용으로 응용연구가 활발히 진행되고 있다(전력저장용, 인공위성의 태양광 에너지 저장 및 자세제어용, 무소음 적진침투용 차세대 전차의 보조동력원 등). 고효율의 에너지 저장 및 재생을 위해 플라이휠 에너지 저장시스템은 크게 .고속화, 고에너지저장을 위한 복합재 플리이휠 로터.공기 마찰손실 저감용 자가 진공펌프(Self Vacuuming system).지지부 접촉마찰로 인한 에너지 손실 저감용 자기베어링/제어부.플라이휠 구동 및 발전을 위한 Motor/generator.고효율 에너지 입출력 제어부 등의 첨단기술부품으로 구성되어 있는 바, 본 논문에서는 이러한 플라이휠 에너지 저장기술의 국내외 개발현황을 소개하고 현재까지 파악된 기술적 문제점 및 향후 기술개발 전망에 대해 논하고자 한다.

  • PDF

Control Method of Bi-Directional ZVS Three-Phase Isolated Interleaved DC-DC Converter (전 영역 ZVS가 가능한 양방향 3상 절연형 인터리브드 DC-DC 컨버터의 제어방법)

  • Lee, Ilyong;Lee, Byungha;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.337-338
    • /
    • 2012
  • 본 논문에서는 전 영역 ZVS가 가능한 양방향 3상 절연형 인터리브드 DC-DC 컨버터의 제어방법에 대해 서술한다. 3상 절연형 인터리브드 DC-DC 컨버터는 모든 스위치가 ZVS동작을 하여 높은 효율을 갖고 3상 구조를 채택하여 전류경로의 분산을 통한 전력전달 능력의 증대 효과 및 입력전류 리플 크기를 줄여주는 인터리브드 효과를 갖는다. 승압/강압 능력이 있는 부스트/벅 컨버터의 구조는 낮은 권선비의 변압기로 높은 승압/강압 전력변환, 에너지원과 부하 사이에 절연이 가능한 구조이며, 인터리브 동작이 이루어짐에도 불구하고 3상을 각각 제어하지 않고 배터리의 전압전류와 출력전압만을 입력받아 벅모드와 부스트 모드 모두 전압, 전류제어를 수행함으로서 시스템의 간략화가 가능하였다. 따라서 본 논문에서는 제안된 DC-DC컨버터의 제어기를 구성하고 실험을 통해 확인하였다.

  • PDF

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

Evaluation of the rehabilitation system with active load control by using EMG biofeedback (재활운동을 위한 능동형 근전도 바이오피드백 시스템 평가)

  • Jung, H.D.;Kim, J.Y.;Lee, Y.H.;Mun, C.W.;Mun, C.S.;Choi, H.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.1
    • /
    • pp.51-58
    • /
    • 2012
  • In this study, the active exercise load control system was developed that monitors patient's muscular condition based on EMG signals and controls the load by biofeedback in real-time. In order to select appropriate muscular parameter for the system, the pre-exercise test was performed to obtain EMG signals from healthy 12 males. Subsequently, the main exercise test was performed to evaluate the active exercise load control system based on IEMG: a selected muscular parameter, on healthy 10 males without musculoskeletal disorder. The accuracy and availability of developed system were confirmed through observing changes between exercise load and IEMG. A correlation was analyzed between the fatigue of muscles and RPE indicating the individual subjective fatigue. As a result, the active exercise load control system that was suggested in this study could be useful to control the initial load-balancing and the amount of exercise appropriate for individual in rehabilitation exercise therapy.

  • PDF

A Study on PFC Buck-Boost AC-DC Converter of Soft Switching (소프트 스위칭형 PFC 벅-부스트 AC-DC 컨버터에 관한 연구)

  • Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.465-471
    • /
    • 2007
  • The system efficiency of the proposed Buck-Boost AC-DC converter is increased by soft switching method. The converter includes to merit of power factor correction (PFC) from sinusoidal control of input current. The switching behavior of control switches operates with soft switching by partial resonance, and then the proposed converter has high system efficiency with decrement of switching power loss. The input current waveform in proposed converter is got to be a sinusoidal form of discontinuous quasi-pulse row in proportion to magnitude of AC input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity. The output voltage of the converter is regulated by PWM control technique. The discontinuous mode action of current flowing into inductor makes to simplify control method and control components. The proposed PFC Buck-Boost converter is analyzed to compare with the conventional PFC Buck-Boost converter. Some computer simulative results and experimental results confirm to the validity of the analytical results.

Reactive Power Control of Single-Phase Reactive Power Compensator for Distribution Line (배전선로용 단상 무효전력 보상기의 무효전력제어)

  • Sim, Woosik;Jo, Jongmin;Kim, Jichan;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.35-37
    • /
    • 2019
  • 본 논문은 배전선로 안정화 구현을 위한 무효전력 보상기의 새로운 무효전력 제어기법을 제안하였으며, 시뮬레이션 및 실험을 통해 무효전력제어 알고리즘의 성능을 검증하였다. 무효전력 제어는 동기좌표계 d축 전류성분 제어를 통해 수행되고, DC 링크 전압을 일정하게 유지하기 위한 전압 제어와 이에 필요한 유효전력은 q축 전류성분 제어를 통해 구현된다. 제안된 무효전력 제어기법에 포함된 DC 리플 보상방식은 추출된 DC 전압의 오프셋 성분을 제거하는 HPF(high pass filter)부와 HPF 위상 특성으로 인해 발생한 위상변화 특성을 보상하기 위한 지연함수부로 구성되며, 리플성분이 보상된 전압을 전압제어기 피드백 성분으로 적용하였다. 시뮬레이션 및 실험을 통해 DC 전압 리플 보상방식이 적용된 무효전력 제어 기법이 적용된 경우 전류 THD가 크게 향상된 결과로부터 제안된 알고리즘의 성능을 검증하였다.

  • PDF

Control and Experiment of Railway Power Compensator System (전기철도용 전력보상장치 제어 및 실험)

  • Woo, Jehun;Jo, Jongmin;Park, Sanghae;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.334-335
    • /
    • 2019
  • 본 논문은 전기철도용 전력보상장치로 사용되는 단상 3레벨 인버터를 제작하였으며, 단상 3레벨 인버터의 유 무효 전력제어기를 설계하였다. 단상 3레벨 인버터는 유 무효전력을 제어하기 위해 가상 동기좌표계 축 상에서 PI 제어기를 통해 전류제어를 수행한다. DC 링크 제어는 3레벨 인버터를 고려할 때 DC 링크 전압의 상단부와 하단부 전압의 평형상태를 유지하기 위해 제어하는 밸런싱 제어기를 포함한다. 10kVA 단상 3레벨 인버터 프로토타입을 설계하였으며, 안정한 유 무효전력제어 특성 실험 결과를 통해 단상 3레벨 인버터의 설계 및 제어 동작의 타당성을 검증하였다.

  • PDF

Operation Characteristics of 5kW Class PEMFC System Using NG as a Fuel (도시가스 사용 5㎾급 고분자 연료전지 운전 특성)

  • 박구곤;이원용;양태현;윤영기;김창수
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.109-113
    • /
    • 2002
  • 도시가스(NG)를 연료로 사용하는 주택용 고분자연료전지 시스템을 국내 최초로 개발하였다. 이 장치는 연료전지부, 개질부, 전력변환부 및 제어부가 통할된 패키지화된 시스템으로 1,000시간 이상 운전 데이터를 확보할 수 있었다.(중략)

  • PDF