• Title/Summary/Keyword: 제어기 교체

Search Result 65, Processing Time 0.027 seconds

Study on the Maintenance Interval Decisions for Life expectancy in Railway Turnout clearance Detector (철도 분기기 밀착검지기 Life expectancy의 유지보수 주기 결정에 관한 연구)

  • Jang, ByeongMok;Lee, Jongwoo
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.491-499
    • /
    • 2017
  • Railway turnout systems are one of the most important systems in a railway and abnormal turnout systems can cause serious accidents. To detect an abnormal state of a turnout, turnout clearance detectors are widely used. These devices consider a failure of a turnout clearance detectors to be a failure of the turnout system, that could hinder train operations. Analysis of turnout clearance detector failures is very important to ensure normal train operation. We categorized failures of detectors into four groups to identify failure characteristics of the 140 detectors, which are composed of main line detectors (A), side tracks (B), detectors that are in operation more than 80 times a day (C) and detectors that are in operation fewer than 10 times per day. Failures of detectors have mainly been caused in the control part, in the cables and sensors; failures are classified into four groups (A, B, C and D). We have tried to find failure density distributions for each type of failures, inferring the parameter distributions a priori. Finally, using the Bayesian inference we proposed a maintenance time for control parts through the mean time of the detector, life and the life expectancy.

Design interchangeable battery modules with spare cells for electrical propelled ship (전기추진선박에서 예비-셀을 이용한 자가 진단 기반의 배터리 관리 시스템 설계 및 구현)

  • Lee, Jong-Hak;Oh, Ji-Hyun;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.5
    • /
    • pp.709-718
    • /
    • 2021
  • As regulations on environmental pollution of ships have been strengthened, interest in smart ships such as electric propulsion ships equipped with hybrid power systems is increasing. Since batteries used in electric propulsion ships have a larger capacity than batteries used in vehicles, the price is high and maintenance is considered important. The ship's battery is manufactured as an integral type and is managed by the battery management system, and the maintenance and repair of the battery is performed through the replacement of the battery. we design and implement a battery module and a control algorithm using pre-cell for easy battery management. In addition, a controller is designed to transmit the data necessary for the electric propulsion ship power system control to the power control system. When a battery to which the corresponding spare-cell is applied is used, the stability of the ship and the battery system is increased, and it can have an advantage in terms of maintenance and repair.

A Study on Improvement of Parking Guidance System to Low-Power Operation for Green Building

  • Lee, Jeong-Jun;Oh, Young-Tae;Lee, Choul-Ki;Yun, Il-Soo;Chung, Sang-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.3
    • /
    • pp.1-8
    • /
    • 2011
  • The parking guidance system can increase driver's convenience with detailed parking information service, but it continuously consumes electrical energy with large amount of sensors, displays and control modules. With the increase of the demand for green and sustainable building design, it becomes a meaningful issue for parking guidance system to reduce operating power. This paper presents the preliminary design and estimated results of a parking guidance system which is optimized to reduce the power consumption mainly on detectors and displays. The system design is based on commercial wireless parking detectors, wireless-loop-detector and earth-magnetic-detector. We have performed system architecture design, communication network design, parking information service scenario planning, battery life regulation and at last operating power estimation. With the 7 years of battery replace cycle, the estimated result for power consumption of designed system was 0.33W/slot, which is 13% of the traditional system's estimation result. The estimated annual maintain cost was similar to the traditional ultrasonic sensor based system's. The low power operable designed system can be expected to reduce CO2 emission.

Design and Implementation of Transformerless 40W LED Light Driver Circuit for Ships (선박용 변압기 없는 40W LED 조명 구동회로의 설계 및 구현)

  • Song, Jong-Kwan;Park, Jang-Sik;Yoon, Byung-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.485-490
    • /
    • 2012
  • In this paper, driver circuit of LED lights for ships is designed and implemented to replace conventional lights with filament which have short life time due to vibration of ships. The driver of LED module is switching circuit without transformer to reduce volume and cost. As switch circuit controls input 220 VAC with PWM, LED module is reliably driven. Power factor is improved by using valley-fill PFC compensation circuit which is handled to pulse current of switching circuit. Serial-parallel LED circuit is applied to reduce change period of lights of long-term navigation ships. Array of serial-parallel can operate even if some of LEDs is damaged. It is suitable for ships that power consumption and power factor of lights including developed drive circuit have 39Watt and 0.925 respectively.

Remote Monitoring Panel and Control System for Chemical, Biological and Radiological Facilities (화생방 방호시설을 위한 원격감시 패널 및 제어시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.464-469
    • /
    • 2019
  • A remote monitoring panel and control system was developed to control various valves and access control chambers, including gas shutoff valves used in CBR(Chemical, Biological and Radiological) facilities. The remote monitoring panel consisted of a main panel installed in the NBC (Nuclear, Biological and Chemical) control room and auxiliary panel installed in the clean room, and the size was divided into pure control and control including CCTV. This system can be monitored and controlled remotely according to the situation where an explosion door and gas barrier door can occur during war and during normal times. This system is divided into normal mode and war mode. In particular, it periodically senses the operation status of various valves, sensors, and filters in the CBR facilities to determine if each apparatus and equipment is in normal operation, and remotely alerts situation workers when repair or replacement is necessary. Damage due to the abnormal operation of each device in the situation can be prevented. This enables control of the blower, supply and exhaust damper, emergency generator, and coolant pump according to the state of shutoff valve and positive pressure valve in the occurrence of NBC, and prevents damage caused by abrupt inflow of conventional weapons and nuclear explosions.

HIPSS : A RAID System for SPAX (HIPSS : SPAX(주전산기 IV) RAID시스템)

  • 이상민;안대영;김중배;김진표;이해동
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.6
    • /
    • pp.9-19
    • /
    • 1998
  • RAID technology that provides the disk I/O system with high performance and high availability is essential for OLTP server. This paper describes the design and implementation of the HIPSS RAID system that has been developed for the SPAX OLTP server. HIPSS has the following design objectives: high performance, high availability, standardization and modularization of external interface, and ease of maintenance. It guarantees high performance by providing 10 independent I/O channels, large data cache, and parity calculation engine. Hardware modularization of the host interface makes it easy to replace host interface hardware module. By providing dual power supply, dual array controller, and disk hot swapping, it provides the system with high availability Implementation of HIPSS and integration test on SPAX has been completed and performance measurement on HIPSS is now going on. In this paper, we provide the detail description for HIPSS system architecture and the implementation results.

  • PDF

A Study on the Interference of Harmonic Frequency during the Change of Urban Transit's Signalling Systems (도시철도 신호시스템의 절체에 따른 주파수 간섭 연구)

  • Jeong, Rag-Gyo;Kim, Beak-Hyun;Joung, Eui-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.469-475
    • /
    • 2010
  • The railway signalling system plays an essential role in the safe and efficient train operation as serving control functions of train operation intervals and train routes. The reliability and safety of the system are very important because the failure of the railway signalling system can lead to train collision or derailment as well as train operation stop. Until now, in railway signalling system the conventional wayside signal mode has been used generally. There are, however, the risk of accidents such as human mistakes caused by that the driver identifies the signal lamp status and controls train speed with the naked eye. It is also necessary to refurbish the obsolete system. Thereby, It is being effective that the onboard signal mode has been recently introduced and applied in order to transmit the speed control information to train by using the computer and communication equipment. It is necessary to switch over the system in a way while providing passengers with an operation service to replace the obsolete signal system. In this paper, we verify the cases through trial assessment which are solved by the way of adding specific functionalities in the problems of interference among the procedure of switch-over processes and a serial of processes for system verification while a train is operated in the new system in parallel to the existing system.

A Field test of an Integrated Electronic Block System for verification of the suitability (통합형 전자폐색제어장치의 적합성 확인을 위한 현장시험)

  • Kim, Young-June;Baek, Jong-Hyen
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6427-6433
    • /
    • 2013
  • For trains to run safely and quickly, the train should always follow the preceding train at a proper spacing. For this purpose, a certain distance between the stations is set for each block section. For the safe operation of trains in one block section, only one train service for an automatic block system is needed. The existing block system is composed an ABS, which is a linked track circuit and line sideway system through the interlocking system. The interlocking system is being replaced with a domestic electronic interlocking system. On the other hand, the block system still uses the relay format of an analog system, and is independently installed of the line sideway systems. Therefore, the existing block system has many problems in terms of construction and maintenance. In addition, the existing domestic line is used for ABS and LEU , which is installed separately, despite the train being controlled by the information of the same signal at the same location. This is not efficient in terms of each product price and the maintenance costs. This paper introduces an integrated electronic block system and the field test results. The field test was carried out through a periodic inspection performed eight times from January to late August.

Development of Multi-functional Tele-operative Modular Robotic System For Watermelon Cultivation in Greenhouse

  • H. Hwang;Kim, C. S.;Park, D. Y.
    • Journal of Biosystems Engineering
    • /
    • v.28 no.6
    • /
    • pp.517-524
    • /
    • 2003
  • There have been worldwide research and development efforts to automate various processes of bio-production and those efforts will be expanded with priority given to tasks which require high intensive labor or produce high value-added product and tasks under hostile environment. In the field of bio-production capabilities of the versatility and robustness of automated system have been major bottlenecks along with economical efficiency. This paper introduces a new concept of automation based on tole-operation, which can provide solutions to overcome inherent difficulties in automating bio-production processes. Operator(farmer), computer, and automatic machinery share their roles utilizing their maximum merits to accomplish given tasks successfully. Among processes of greenhouse watermelon cultivation tasks such as pruning, watering, pesticide application, and harvest with loading were chosen based on the required labor intensiveness and functional similarities to realize the proposed concept. The developed system was composed of 5 major hardware modules such as wireless remote monitoring and task control module, wireless remote image acquisition and data transmission module, gantry system equipped with 4 d.o.f. Cartesian type robotic manipulator, exchangeable modular type end-effectors, and guided watermelon loading and storage module. The system was operated through the graphic user interface using touch screen monitor and wireless data communication among operator, computer, and machine. The proposed system showed practical and feasible way of automation in the field of volatile bio-production process.

VOC/HAPs Emission Characteristics & Adsorption Evaluation for Paint Products in Busan Area (부산지역 페인트제조시설의 VOC/HAPs 배출특성 및 흡착능 평가)

  • Song, Bok-Joo;Lee, Seung-Min;Cho, Gab-Je;Cho, Jeong-Gu;You, Pyung-Jong;Kim, Gi-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2012
  • In this study, we suggested adequate control technology by analyzing emission process and main chemical of VOC/HAPs generated from four paint factories in Busan area. And we estimated whether Kapok fiber, which is a natural material, can be commercially used for an absorbent by testing adsorption ability. As a result of this sturdy, above 60% of VOC/HAPs was volatilized and dispersed inside the working place without conducting control system of facilities during manufacturing paints. Concentration profile of VOC/HAPs, which is volatile naturally outside the factories, is surveyed above 70% at Toluene, Ethylbenzene, and Xylene. And a result of evaluation of odor attribution level about the component whose Odor Threshold is known, it is estimated that major cause material of A, B, C factories is Toluene and that of D factory is m/p-Xylene. And that result presented design arguments such as facilities specifications, activated carbon filling volume, and replace cycle of activated carbon as control technology. Also, that result presented emission process improvement such as adsorption of central-controlled ventilation device, installation of inlet flenge, and potable cleaning process. The rate of pollutant adsorption of Kapok fiber, which is natural material, is indicated about 91.9%, 66.7%. That result validated the possibility as replacement of activated carbon.