• Title/Summary/Keyword: 제습공조기

Search Result 13, Processing Time 0.025 seconds

A Study on the Dehumidification effect of Adsorbent at low Temperature (저온에서 흡착제의 제습효과에 대한 연구)

  • Lee, Min-Seok;Jeong, Yun-Ho;Lim, So-Min;Heo, Jae-Woo;Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.177-182
    • /
    • 2020
  • Interest in heat pumps is increasing as an eco-friendly and energy-saving heating method. In particular, in order to develop a heat pump capable of heating in a low-temperature area, research to prevent frost on the surface of the outdoor unit is increasing. In other words, when heating through a heat pump in a low-temperature area, a frost layer is formed on the surface of the outdoor unit, which lowers the heat transfer performance, thereby reducing the heating capacity. Therefore, in this study, an adsorption-type dehumidification system is attached to remove the moisture vapor of the air into the outdoor unit of the heat pump. It is believed that this study can suggest the most effective dehumidification method in low temperature regions. In addition, it is expected that a heat pump with high energy efficiency can be developed by attaching an adsorption dehumidifying system to the front of the outdoor unit of the heat pump.

A Study on Analysis of Air Conditioning System in Ice Rinks (빙상경기장의 공조시스템 분석에 관한 연구)

  • Chae, Mun-Byoung;Yun, Hae-Dong;Lee, Jong-Sin;Byun, Woon-Seob
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.441-446
    • /
    • 2009
  • A modern industrial society is presently considering not only cultural life but also health promotion to enhance the quality of life. There are many ways to enjoy the wellbeing life. Especially, ice-skating has been focused on as leisure sports with many remarkable advantages. Even though ice-skating was recognized as winter sport, nowadays people enjoyed skating are increased more and more because of indoor ice link. So, construction of indoor ice link has been boomed up. However, The techniques of ice link freezing system are insufficient because the ice link freezing system on the local construction was designed by advanced country techniques. So, this study has been conducted to analyze the air conditioning and refrigeration system in existing local ice link to suggest the design method of ice link.

  • PDF

Dynamic Simulation of a Dedicated Outdoor Air-conditioning System (외기 전용 공조기의 동특성 시뮬레이션)

  • Kim, Jung-Min;Kim, Young-Il;Chung, Kwang-Seop;Park, Seung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

Research on Heat and Mass Transfer Coefficient in the Packing Layer With a Solar Desiccant Heating/Cooling System (태양열 데시컨트 냉난방시스템 중 충진층에 있어서의 열 물질전달에 관한 연구)

  • Yohana, Eflita;Choi, Kwang-Hwan;Kim, Bu-Ahn;Kim, Dong-Gyu;Paek, Ki-Dong;Kim, Ji-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.17-24
    • /
    • 2006
  • 최근에 에너지절약 차원에서 종래의 공조방식을 대신할 새로운 냉난방시스템 개발이 요구되고 있는데, 본 논문에서는 태양열 집열기를 이용하는 데시컨트 시스템 중 제습역할을 실질적으로 담당하는 제습기의 충진층 부분에서의 열 및 물질전달에 관한 일련의 해석 결과를 발표하고 있다. 제습과정에서 액체흡수제는 충진층에서 열 뿐만 아니라 물질전달을 수반하게 되는데, 이 결과 건물에 냉방 및 난방효과를 가져다 준다. 따라서 이 충진층의 최적 설계가시스템의 효율을 극대화하기 위해서는 무엇보다도 중요한데, 이를 위해서는 충진층에서의 열 및 물질전달 양상을 규명하여야 한다. 따라서 금번 실험에서는 공기와 액체흡수제와의 접촉면적을 넓히기 위해서 충진재로써 3cm(직경) ${\times}$ 3cm(높이)인 시판중인 플라스틱 재질을 사용하고, 실질적으로 40cm(너비)${\sim}$40cm(깊이)${\times}$40cm(높이)의 충진층을 직접 제작하여 실험을 행하였다. 그 결과, 공기측 열 및 물질전달 계수는 공기 온도와 밀접한 관계를 갖고 있으며, 또한 물질전달계수는 열전달계수와 같은 경향을 보이고 있음을 알 수 있었다.

A Study on Cooling Performance and Exergy Analysis of Desiccant Cooling System in Various Regeneration Temperature and Outdoor Air Conditions (재생온도와 외기조건 변화에 따른 제습 냉방시스템의 냉방 성능 및 엑서지 해석에 관한 연구)

  • Lee, Jang Il;Hong, Seok Min;Byun, Jae Ki;Choi, Young Don;Lee, Dae Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.413-421
    • /
    • 2014
  • Desiccant cooling system is an air conditioning system that uses evaporative cooler to cool air and it can perform cooling by using heat energy only without electrically charged cooler. Thus, it can solve many problems of present cooling system including the destruction of ozone layer due to the use of CFC[chloro fluoro carbon] affiliated refrigerants and increase of peak power during summer season. In this study, cooling performance and exergy analysis was conducted in order to increase efficiency of desiccant cooling system. Especially, using exergy analysis based on the second law of thermodynamics can resolve the issue related to system efficiency in a more fundamental way by analyzing the cause of exergy destruction both in whole system and each component. The purpose of this study is to evaluate COP[coefficient of performance], cooling capacity and exergy performance of desiccant cooling system incorporating a regenerative evaporative cooler in various regeneration temperature and outdoor air conditions.

Research on the Performance of Total Heat Exchanger in a Solar Air-Conditioning System (태양열 이용 냉난방 공조시스템 중 전열교환기 성능에 관한 연구)

  • Kim, K.H.;Choi, K.H.;Kum, J.S.;Kim, B.C.;Kim, J.R.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.45-53
    • /
    • 1999
  • This report Introduces a total heat exchanger in a solar air-conditioning system using Lithium Chloride(LiCl) solution. The hot and humid outside air is cooled and dehumidified by LiCl solution that is sprayed on the packed layer of the total heat exchanger. LiCl solution once diluted is concentrated again in a regenerator using solar energy. Three types as the packed materials were used in this experiment and the dehumidification performance was evaluated by the value of $k_xa(kg/h{\cdot}m^3{\cdot}{\Delta}x)$, overall mass transfer coefficient based on a humidity ratio potential difference, the influence of inlet LiCl solution flow rate, air flow rate, packed layer height on $k_xa$ was investigated. It was found that air flow rate, LiCl solution flow rate, packed layer height for all types had a great influnce on the value of $k_xa$.

  • PDF

Data Reduction on the Air-side Heat Transfer Coefficients of Heat Exchangers under Dehumidifying Conditions (제습이 수반된 공조용 증발기 습표면의 열전달계수 데이터 리덕션)

  • Kim, Nae-Hyun;Oh, Wang-Kyu;Cho, Jin-Pyo;Park, Hwan-Young;Yoon, Baek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.73-85
    • /
    • 2003
  • Four different methods of reducing the heat transfer coefficients from experimental data under dehumidifying conditions are compared. The four methods consist of two different heat and mass transfer models and two different fin efficiency models. Data are obtained from two heat exchanger samples having plain fins or wave fins. Comparison of the data with the reduction methods revealed that the single potential heat and mass transfer model yielded the humidity independent heat transfer coefficients. Two different fin efficiency models - enthalpy model and humidity model - yielded approximately the same fin efficiencies and accordingly approximately the same heat transfer coefficients. The heat transfer coefficients under wet conditions were approximately the same as those of the dry conditions for the plain fin configuration. For the wave fin configuration, however, wet surface heat transfer coefficients were approximately 12% higher. The pressure drops of the wet surface were 10% to 45% larger than those of the dry surface.

Thermodynamic Modeling of Finned Tube Evaporator for Dehumidification and Air Conditioning (제조공조용 핀-관형 증발기의 열성능 모델링)

  • 박병규;이태환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1020-1030
    • /
    • 2000
  • A crossflow finned tube evaporator has been investigated using tube-by-tube method. The refrigerant flows inside tubes while the air passes outside the finned tue. R134a for a refrigerant and wet air were used in this analysis. Three refrigerant circuitries, complex or simple, were compared. The effects of refrigerant circuitry and airside condensation on thermal performance such as heat transfer rate, enthalpy of refrigerant, temperature of refrigerant and air, pressure of refrigerant and average condensate layer thickness were investigated. It was found that this method could be applied to the analysis of finned tube evaporator for dehumidification and air conditioning.

  • PDF

Analysis of the Top Loss Coefficient for Flat Plate Collector in a Solar Air-Conditioning System during Winter (태양열 이용 냉난방 공조시스템중 평판형 집열기의 동계 상부 열손실 해석)

  • Kim, B.C.;Choi, K.H.;Kum, J.S.;Kim, J.R.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.15-24
    • /
    • 1998
  • There are mainly 3 heat losses from solar collector; top, bottom, and edge heat loss. Usually edge heat loss is small so that could be neglected. Of the total thermal losses occurring in a flat plate solar collector, top loss heat losses are dominant. Therefore it is necessary to calculate the top loss coefficient accurately in order to find out performance of solar collector. The flat plate solar collector(regenerator in summer) used in this study was made for year-round all conditioning. In order to find out collector efficiency for heating in winter without a system change, outdoor experiment was done. The top loss coefficient of this collector was about 3 to $4.5W/m^2^{\circ}C$. Futhermore use of selective coating in trickling surface can improve a performance of flat plate solar collector.

  • PDF

Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer (액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구)

  • Choi, K.H.;Yoon, J.I.;Kim, B.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.