• Title/Summary/Keyword: 제동에너지

Search Result 136, Processing Time 0.03 seconds

Sediment Characteristics of Waste Disposal Sites in the Southwestern UUeung Basin, the East Sea (동해 울릉분지 남서해역 해양투기장의 퇴적물 특성)

  • Chun, Jong-Hwa;Huh, Sik;Han, Sang-Joon;Shin, Dong-Hyeok;Cheong, Dae-Kyo;Hong, Ki-Hoon;Kim, Suk-Hyun
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.4
    • /
    • pp.312-322
    • /
    • 1999
  • We have studied both submarine morphology and sediment characteristics of waste disposal sites in the southwestern Ulleung Basin, East Sea, as part of a marine environmental preservation program. The Jung waste disposal site in the outer shelf is characterized by the thick accumulation of coarse-grained palimpsest sediments and fine-grained sediments from various sources. The Byung waste disposal site in the continental slope is generally characterized by hemipelagic muds with intermittent sandy sediments originated from the outer shelf and upper slope. The hemipelagic sediments, draping the seafloor, consist of fluidized muds. The core sediments show numerous bioturbation structures which cause vertical mixing of sediments. The surface sediments can be divided into four sand types (S-1, S-2, S-3, and S-4) and two mud types (M-1 and M-2) based on relative contents of reworked coarse-grained palimpsest sediments and fine-grained sediments. sorting and heavy mineral contents. The sands are probably relict sediments reworked during high-energy conditions such as typoon or storm. On the other hand, the muds were originated from various sources such as recent input from the Nakdong River, reworked fine-grained sediment from the shelf or suspended particulate matter from the East Sea Warm Current.

  • PDF

A Study of Copper Production Techniques at the Archaeological Site in Gwanbukri, Buyeo in the 6th and 7th Centuries (6~7C 부여 관북리 유적의 동 생산기법 연구)

  • Lee, Ga Young;Cho, Nam Chul
    • Journal of Conservation Science
    • /
    • v.36 no.3
    • /
    • pp.162-177
    • /
    • 2020
  • Research was conducted to characterize the copper production and smelting process with 11 copper smelting by-products (copper slag and copper crucible) excavated from the NA and LA areas at the Gwanbuk-ri archeological site in Buyeo. Scanning electron microscopy-energy dispersive spectroscopy, wavelength dispersive X-ray fluorescence, X-ray diffraction, and Raman microspectroscopy were employed in the analysis. The research results reveal that the copper slag from Gwanbuk-ri contained silicate oxide, magnetite, fayalite, and delafossite, which are typical characteristics of crucible slag and refined slag. The outward appearance and microstructure of the slag were grouped as follows: 1. glassy matrix + Cu prill, 2. glassy matrix + Cu prill + magnetite, 3. silicate mineral matrix + Cu prill, 4. crystalline (delafossite and magnetite) + amorphous (Cu prill), 5. magnetite + fayalite, and 6. slag from slag. The copper slags from Guanbuk-ri were found to contain residues of impurities such as SiO2, Al2O3, CaO, SO4, P2O5, Ag2O, and Sb2O3 in their microstructure, and, in some cases, it was confirmed that copper, tin and lead are alloys. These results indicate that refining of intermediate copper(including impurities) and refining of alloys of copper(including impurities) - tin and refining of copper(including impurities) - tin - lead took place during the copper production process at Gwanbuk-ri, Buyeo.

The Removal of Indoor Suspended Microorganisms of Eco-friendly Antimicrobial Copper Net Filter (친환경소재인 항균동망 필터의 실내 부유 미생물 제거 연구)

  • Kim, Dong-Woo;Je, Dong-Hyun;Ji, Keunho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.311-316
    • /
    • 2018
  • As the lives of people have improved, the demand for improved indoor air quality has increased. Various methods are used to remove biological air pollutants, such as UV/photocatalytic devices and ozone generators. However, these methods have disadvantages such as energy consumption, high corrosivity and toxicity. To overcome these disadvantages, an antibacterial copper filter was fabricated and its antimicrobial activity was then tested against two fungi (P. pinophilum, C. globosum) and one bacteria (S. aureus) Moreover, the ability to remove suspended microorganisms was tested step by step from the chamber stage to the air conditioning system. The results revealed 100% antimicrobial activity after 24 hours for the two fungi, while this value was 99.9% after 18 hours for the bacteria. Moreover, the antibacterial activity was higher when the chamber and air purifier were used than was obtained using a general antibacterial HEPA filter. Also, as a filter for system air conditioner, the antibacterial activity was lowered in offices and hospitals. In conclusion, the copper filter was found to have sufficient antibacterial activity for use as an antibacterial filter; however, further research on its preparation methods and materials is warranted.

An Analysis of Idling Stop Time Using Real On-road Driving Data (실도로 주행 데이터를 이용한 공회전 정지 시간의 분석)

  • Hong, Seong-Tae;Lee, Beom-Ho;Lee, Dae-Yeop;Sim, Mu-Gyeong;Im, Jae-Myeong
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.1
    • /
    • pp.25-38
    • /
    • 2010
  • In this study, the real on-road driving data were analyzed to draw the various characteristics related to idling of vehicles. The results revealed that the average idling time of a city bus corresponds to 30.9% of the total daily driving time. Among this, for about 21.6% of the total daily driving time, it is available that an engine can be halted while the vehicle stops. It is a daytime when the portion of time, for which idling stop is available, is peak. Due to idling stop, an increase of turnaround was not found throughout this analysis. When a city bus stops at a traffic right, idling periods were long enough to execute the idling stop, during which an engine halts. Whereas, during the idling time for bus stops, the idling periods were not so long enough to execute idling stop. Deceleration periods among the total turnarounds of a city bus occupies about 24.7%, during which, for about 30%, a deceleration maintains for more than four seconds. Thus, using the energy during deceleration period, which then can be recovered from braking energy, it was also found that a hybrid system can be effectively implemented to a city bus.

Comparison of Combustion, Emissions and Efficiency Characteristics as Varying Spark Timings and Excess air ratios in an Ammonia-fueled Direct Injection Spark Ignition Engine (직접분사식 암모니아 전소 엔진에서 점화 시기와 공기과잉률의 변경에 따른 연소 및 배기, 효율 특성 비교)

  • Yonghun Jang;Cheolwoong Park;Yongrae Kim;Young Choi;Chanki Min;Seungwoo Lee;Hongkil Baek;Jeongwoo Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.1-10
    • /
    • 2023
  • Due to the development of the industrial revolution, regulations on exhaust emissions have been continuously strengthened to reduce the rapidly increasing greenhouse gas emissions. The use of environmentally friendly fuels is essential to meet these regulations. Hydrogen has been attracting attention as a future environmentally friendly fuel, but due to its material properties, it faces significant challenges in handling and storage. As an alternative, ammonia has been proposed. Ammonia can be easily liquefied at room temperature compared to hydrogen and has a high energy density. In order to examine the applicability of ammonia as an engine fuel, experiments were conducted to investigate the effects of changes in combustion control parameters in a direct injection ammonia combustion engine. The experiments were conducted by varying two variables: spark timing and excessive air ratio. Observations were made on combustion stability and the trends of exhaust emissions such as nitrogen oxides and unburned ammonia under the conditions of an engine speed of 1,500 rpm and medium to high loads (brake torque of 200 Nm). By optimizing the combustion control parameters, conditions for stable combustion even when using ammonia as the sole fuel were identified, and plans are underway to apply strategies for future expansion of the operating range.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF