• Title/Summary/Keyword: 정확한 차폐

Search Result 117, Processing Time 0.032 seconds

An Accurate Method to measure Shielding Effectiveness of EMI Spray Coating Film (EMI 스프레이 코팅막의 차폐효과를 측정하기 위한 정확한 방법)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.79-83
    • /
    • 2018
  • An accurate method to measure shielding effectiveness(SE) of EMI spray coating film is presented. After high frequency simulating, Circular coaxial standard test fixture is fabricated. A sample of EMI spray coating film was fabricated for insertion into a circular coaxial standard test fixture. The measuring instrument used an Agilent 8722ES vector network analyzer for the SE measurement. The exact SE of copper and silver mixed spray coating sample was measured by the composition of the measuring instrument and the measuring sample. The SE of copper sample was measured at 70 dB and the SE of copper and silver mixed spray coating sample was measured at 60 dB. As a result of the measurement, the reliability of the circular coaxial standard test fixture was confirmed.

Effect of hiding-exposure effect on concentration profile of suspended sediment (하상재료의 차폐효과가 부유사의 농도분포에 미치는 영향)

  • Byun, Jisun;Son, Minwoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.259-259
    • /
    • 2021
  • 하상을 구성하는 사립자들이 흐름에 의해 움직이기 시작하는 상태를 한계운동이라 하며, 한계운동이 시작될 때의 흐름조건을 한계조건이라 한다. 흐름에 부유되어 이동하는 부유사의 농도분포를 정확하게 산정하기 위해서는 하상재료의 침식율을 정확하게 산정하는 것이 필요하다. 특히 하상재료에 다양한 크기의 하상재료가 혼합되어 있을 때에는 차폐효과(Hiding-Exposure Effect)에 대한 고려가 필요하다. 여기서 차폐효과란, 동일한 크기의 사립자들로 구성된 균질 하상에 비해 비균질 하상에서 굵은 사립자가 흐름에 더 많이 노출되어 한계소류력이 감소하고, 잔 사립자의 한계소류력이 굵은 사립자로 인해 증가하는 현상을 의미한다. 하상토의 차폐효과는 Shields (1936)에서 제안된 무차원 한계소류력을 각 사립자의 크기별로 산정 한 후 보정계수를 곱해 고려해주는 것이 일반적이다. 이에 본 연구에서는 하상재료의 차폐효과가 부유사의 연직방향 농도분포에 미치는 영향을 살펴보았다. 연구를 수행하기 위해 하상토의 입도분포를 바탕으로 차폐효과를 고려하고 연직방향으로의 유사농도를 계산하는 유사이동모형을 개발하였다. 수치모형의 검증은 실험실 실험자료와의 비교를 통해 수행되었다. 수치모의 결과로부터 차폐효과를 고려하지 않는 경우에는 하상에서의 침식율이 과다하게 산정되는 것으로 나타났으며, 불균질한 하상재료로 구성된 하천에서 부유사의 연직방향 유사농도를 정확하게 계산하기 위해서는 차폐효과에 대한 고려가 필요하다는 결론이 도출되었다.

  • PDF

Improved water hazard warning system using small radar (최적관측을 위한 소형레이더 연계운영 기법 개발)

  • Han, Myoung-sun;Jang, Bong-joo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.184-184
    • /
    • 2018
  • 도시의 발달에 따라 도심유역 홍수 도달시간이 점점 짧아지고 있다. 이러한 돌발홍수를 효과적으로 관측하기 위해 소형레이더가 각광받고 있으며, 이에 따라 국내 수도권에 2개의 소형레이더를 운영하고 있다. 그러나 현재 이들 레이더의 경우 개별 차폐분석을 퉁해 운영하고 있어 관측효율이 낮다. 이를 극복하기 위한 통합 차폐분석이 필요하다. 이 결과 좀더 저고도 관측이 가능하고 이를 통해 정확한 강우관측이 가능함을 알 수 있다. 각각 레이더의 차폐 분석과 2대를 연계한 통합차폐 분석결과를 제시하고 통합운영을 위한 최적 관측고도를 제시하고자 한다.

  • PDF

Retrieval of Damaged Weather Radar Data using Image Morphology Technique (영상 모폴로지 기법을 활용한 손상된 기상레이더자료 보정 기법)

  • Jang, Kong-Joo;Kim, Hyunjung;Lim, Sanghun;Lee, Keon-Haeng;Hyun, Myung-Suk;Lee, Dong-Ryul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.19-19
    • /
    • 2016
  • 오늘날, 보다 정밀한 대기기상 분석과 정확한 기상 예측을 위해 보편적으로 기상레이더를 활용하고 있다. 지표면과 가까운 저층에서 주로 발생하는 국지성 호우 및 돌발기상에 대한 대응을 위해서는 기상레이더 역시 저층 관측이 수반되어야 한다. 하지만, 국토 대부분이 산악지형으로 이루어진 우리나라에서는 산악지형에 의한 지형클러터와 빔 차폐의 영향을 피하여 원만한 기상관측을 위해 대부분의 기상레이더가 고지대에 설치, 운영되고 있다. 그럼에도 불구하고 낮은 고도각의 레이더 관측 자료에서는 여전히 지형 클러터 및 차폐에 따른 영향으로 인해 자료 품질의 신뢰성이 떨어질 수 밖에 없다. 현재 클러터나 차폐가 발생한 영역에 대해 상위 고도각의 자료를 이용하는 등의 방법으로 보정을 수행하고 있지만 각 고도각 관측 자료들의 시간적 차이가 발생함에 따라 부정확성이 발생할 수 있다는 단점이 있다. 따라서 본 논문에서는 차폐 영역 보정에 대한 처리를 위해 단일 관측자료 만을 이용하는 방법을 적용함으로서 시간적 불일치성에 대한 문제를 해결하고, 초단기 강수예측을 위한 강수에코의 정확한 추적을 위해 레이더 영상에 적응적인 차폐, 클러터 보정 기법을 제안한다. 제안 기법은 강수에코의 형태학적 구조에 기반한 차폐보정을 위해 영상 처리 기법의 한 종류인 모폴로지 기법을 적용함으로써 강수에코의 모양, 크기, 및 구조에 따라 침식 및 팽창 과정을 수행하여 클러터나 차폐로 인해 소실된 강수에코 영역을 보정한다. 실험결과 레이더 강수추정의 정확성 향상을 꾀할 수 있었으며, 강수 추적을 위한 강수에코의 형태학적 복원이 가능함을 확인하였다. 이로부터, 향후 저층관측 레이더 자료의 활용성 증대와 에코 형태에 기반한 강수 추적 알고리즘 개발 및 성능 향상에 활용될 수 있을 것으로 기대한다.

  • PDF

Analysis of integrated GPS and GLONASS double difference relative positioning accuracy in the simulation environment with lots of signal blockage (신호차폐 시뮬레이션 환경에서의 통합 GPS/GLONASS 이중차분 상대측위 정확도 분석)

  • Lee, Ho-Seok;Park, Kwan-Dong;Kim, Du-Sik;Sohn, Dong-Hyo
    • Journal of Navigation and Port Research
    • /
    • v.36 no.6
    • /
    • pp.429-435
    • /
    • 2012
  • Although GNSS hardware and software technologies have been steadily advanced, it is still difficult to obtain reliable positioning results in the area with lots of signal blockage. In this study, algorithms for integrated GPS and GLONASS double difference relative positioning were developed and its performance was validated via simulations of signal blockages. We assumed that signal blockages are caused by high-rise buildings to the east, west, and south directions. And then, GPS-only and integrated GPS/GLONASS positioning accuracy was analysed in terms of 2-dimensional positioning accuracies. Compared with GPS-only positioning, the positioning accuracy of integrated GPS/GLONASS improved by 0.3-13.5 meters.

Prediction of Shielding Effectiveness in Honeycomb Structure Using the Modified Design Equation (수정된 설계 방정식을 이용한 허니컴 구조의 차폐 효과 예측)

  • Lee Kyung-Won;Cheong Yeong-Chul;Hong Ic-Pyo;Yook Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.9 s.100
    • /
    • pp.862-871
    • /
    • 2005
  • In this paper, the modified design equation of shielding effectiveness was presented to predict more accurately the shielding effectiveness of honeycomb structure with hexagonal waveguide. The design equation of shielding effectiveness in honeycomb was represented from adding shielding effectiveness of single lattice to shielding effectiveness of infinite array of single lattice. This paper proposed the generalized design equation of shielding effectiveness by analyzing basis lattice of hexagonal waveguide which composes honeycomb structure and infinite array structure of basis lattice. To provide the validity of the modified design equation of shielding effectiveness in this paper, comparison with other available date using 3D EM commercial software is made.

A Evaluation of Shielding Deficiency by Means of Gamma Scanning Test (Gamma Scanning Test에 의한 대단위 차폐체의 결함 평가 연구)

  • Lee, B.J.;Seo, K.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.228-236
    • /
    • 1995
  • In this paper the method to evaluate shielding deficiency by gamma scanning test was presented and verified theoretically by Monte Carlo code which is one of the best effective method for radiation shielding calculation. The cylindrical shielding model was selected to evaluate shielding deficiency by gamma scanning test. First, the reference shielding according to the design requirement of cask was fabricated specially and reference values were measured with Co-60 source and scintillation detector. As a result with which calculated the reference values, it is shown that maximum deficiency thickness for lead of true cylindrical shielding model was 12mm. To verify this, thickness of lead was calculated by MCNP code and maximum deficiency thickness was 11.6mm. The experimental result obtained by the use of reference shielding was in good agreement with the theoretical result within 4.1%. So, this method can be applied to inspect the shielding ability for great shielding or cask which the radioactive material is used. To perform measurement more exactly, the further work on the development of measuring equipment to display the results on the screen will be required.

  • PDF

Quality Control for Improvement of Accuracy of Radar data in ImJin (임진강 레이더 관측자료 정확도 향상을 위한 QC)

  • Hyun, Myung-Suk;Kim, Yang-Su;Kim, Kyung-Eak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1963-1966
    • /
    • 2007
  • 본 연구에서는 기존의 IIR 필터가 아닌 장기간의 누적 반사도자료를 활용하여 실제 레이더 반사도의 감쇄정도를 정량적으로 파악하고 차폐지역 후면의 반사도를 보정하여 강우산정시 기초자료인 반사도 자료처리에서 개선된 품질관리기법을 적용하여 그 결과를 분석해보고자 하였다. 개발된 품질관리기법을 적용한 사례분석 결과, 기 IIR필터에 의한 지형에코제거에 비해 강수에코의 제거현상 등의 오차발생이 줄어들고 차폐보정으로 반사도 강도도 향상되었다. 실제 C밴드에 비해 감쇄의 영향이 적은 광덕산 S밴드 레이더와 비교한 결과에서도 차폐보정을 통하여 완전차폐를 제외한 부분차폐지역의 경우 상당히 개선된 결과를 보여주었다.

  • PDF

Dose Distributions in a Shielded Vaginal Cylinder using a HDR Co-60 Source (고선량 Co-60 선원이용시 차폐된 질 원주기구의 영향)

  • 김진기;김정수;김형진;권형철;강정구
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 1997
  • The present work is determine to the dose distribution reduced by the insertion of a shielded into a vaginal cylinder around a $\^$60/CO source in brachytherapy, and to the source calibration. It was investigated by measuring the relative dose around a 2.5cm diameter shielded vaginal cylinder in a polystyrene phantom by use of a ionization chamber. Measurements were made with the cylinder unshielded and 0.55cm thick 90$^{\circ}C$ lead shields inserted. Also, the dose distribution compared measurement value with calculation value according to the device manufacturer and the multiple-divided dose tables. A reduction in dose was observed on the unshielded side of the cylinder which increased with distance from the source and it does 4.4% within 1cm from the surface of the cylinder. On the shielded side of the cylinder, the dose at the surface is reduced to about 20.4% of its value without the shield. The effective attenuation factor entered for the 90$^{\circ}C$ lead shielded cylinder was average 0.2 in a $\^$60/CO moving source. In comparision with the dose calculation mathods, the multiple-divided dose tables are difference less than ${\pm}$4.1% with measured data in a $\^$60/Co source.

  • PDF

Study on the application methods of the power induction screening factor in urban and rural areas using the building density distribution (건물 밀집도 분포를 이용한 도시와 시골의 전력유도 차폐 계수 적용 방안 연구)

  • Choi, Mun-hwan;Lee, Snag-mu;Cho, Pyung-dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.500-502
    • /
    • 2013
  • The metallic underground pipes like as metropolitan water supply pipes and gas pipes have a screening effects for power induction phenomenon. Generally, urban area has more metallic underground facilities than rural areas because of its buildings or population density. So we can expect high screening effects for the power induction in urban areas, and we call it the city screening factor. We had carried out the measuring test in urban and rural area respectively 30 sites to prove the actual effects of city screening factor and we derived the numerical value of city screening effects. But we faced with a difficult question that how we can classify the real urban areas or rural areas correctly. In this paper, we introduce the classification method using density of building in test area to apply the city screening factor reasonably.

  • PDF