• Title/Summary/Keyword: 정화조

Search Result 101, Processing Time 0.024 seconds

Occurrence of Culex pipiens (Diptera, Culicidae) and Effect of Vent Net Sets for Mosquito Control at Septic Tanks in South-eastern Area of the Korean Peninsula (한반도 동남부 지역 정화조 내의 빨간집모기군(群)(Culex pipiens complex) 발생과 정화조 환기통의 방충망 설치에 의한 방제효과)

  • Lee Dong-Kyu
    • Korean journal of applied entomology
    • /
    • v.45 no.1 s.142
    • /
    • pp.51-57
    • /
    • 2006
  • Culex pipiens complex larvae were found at the septic tanks in Busan and Ulsan cities located in South-eastern area of Korean peninsula. The larvae were collected in 25, 35 and 75 septic tanks out of 3,527, 622 and 1,111 septic tanks which the breeding rates were averages of 0.7%, 5.6% and 6.8% in Busan from January to May, 2003; Busan from February to March, 2004; and Ulsan from January to April, 2005, respectively. The average numbers of the mosquitoes in the tanks were 38.8, 14.9 and 13.7 larvae/dip with a 355-ml dipper. The larval densities were from 25.4 larvae/dip in January to 43.7 larvae/dip in April. 2003 which were not significantly different between them. It was the first report to find mosquito breeding at septic tink in Republic of Korea. Culex pipiens larvae were found in 6 out of 379 septic tanks at complex buildings (over $2,000m^2$ in size) in Ulsan from June to September, 2005, having an average of 1.6% for mosquito breeding rate. The mosquito larvae were collected in 8 and 530 septic tanks out of 210 and 3,729 septic tanks at large (over 300 homes) and small apartments (below 300 homes) with 3.8% and 14.2% of the average breeding rates, respectively At the septic tanks of private houses for below 50 persons, 708 out of 7,178 septic tan had Cx. pipiens larvae and pupae with 9.9% of the average breeding rate. Total average of the mosquito breeding rate was 10.9% of the investigated septic tanks of residential buildings in Ulsan. The number of mosquito larvae in the septic tanks were 15 to 75 larvae/dip. The bent net sets of septic tanks prevented from mosquito breeding to the rate of 93.1%.

On decrease program of Radioactive Wastewater and Sewages in High Dose Radioiodine Therapy Ward (고용량 방사성옥소 치료병실의 오.폐수 저감화를 위한 연구)

  • Ryu, Jae-Kwang;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.19-26
    • /
    • 2008
  • Purpose: In general, We discharged radioactive wastewater and sewages less than $8.1{\times}10^{-13}$ Ci/ml in a exclusive water-purifier tank. Our hospital operating three exclusive water-purifier tank for radioactive wastewater and sewages of 60 tons capacity respectively. In order to meet the criteria it need a enough decay more than 125 days per each exclusive tank. However, recently we fell into the serious situation that decay period was decreased remarkably, owing to the wastewater amount increased rapidly by enlarge the therapy ward. For that reason, in this article, I'd like to say the way that reducing of radioactive wastewater and sewages rationally. Materials and Methods: From January, 2006 to October, four hundred and two cases were analyzed. They were all hospitalized during 3 days and 2 nights. We calculated the average amount of water used (include toilet water used, shower water used, washstand water used, $\cdots$), each exclusive water-purifier tank's decay period, as well as try to search the increased factors about water-purifier tank inflow flux by re-analysis of the procedure of radioisotope therapy step by step. Results: We could increase each exclusive water-purifier tank's decay period from 84 days to 130 days through the improvement about following cause: (1) Improvement of conventional toilet stool for excessive water waste $\rightarrow$ Replacement of water saving style toilet stool (2) Prevention of unnecessary shower and wash (3) Stop the diuretics taking during hospitalization (4) Analysis of relationship between water intakes and residual dose of body (5) Education about outside toilet utilization before the administration (6) Changed each water-purifier tank's maximum level from85% to 90% Conclusion: The originality of our efforts are not only software but hardware performance improvements. Incidentally the side of software's are change of therapy procedures and protocols, the side of hardware's are replacement of water saving style toilet stool and change of each water-purifier tank's maximum level. Thus even if a long lapse of time, problem such as return to the former conditions may not happen. Besides, We expect that our trials become a new reasonable model in similar situation.

  • PDF

Development of Amalgamated Septic Tank using Mineral Sintered Body (광물 소결체를 이용한 합병정화조 개발에 관한 연구)

  • 김광수;김영훈;강헌찬
    • Resources Recycling
    • /
    • v.9 no.4
    • /
    • pp.56-62
    • /
    • 2000
  • This study was introduced an amalgamated septic tank system using mineral sintered body was made from non-metallic minerals with a ability being attached or accelerating a vitality of soil microorganism for the effective wastewater treatment. Experimentally, we made an amalgamated septic tank appling anaerobic-aerobic process experimental facilities to two personal houses for handling a residental sewage directly on a small scale from the place of origin. The results are shown as follows; The COD\ulcorner and BOD of effluent were about 10 mg/l after the treatments and T-N removal efficiency was 60-70%. Moreover these results suggested the possibility of denitrification without adding organics and more than 80% of T-P removal also showed the possibility of wastewater treatment biologically.

  • PDF

A Study on the Treatment of Ammonia-Nitrogen in the Septic Tank Effluent Using Biological Fluidized Bed (생물학적(生物學的) 유동층(流動層)을 이용(利用)한 정화조유출수(淨化槽流出水)의 암모니아성(性) 질소제거(窒素除去)에 관한 연구(研究))

  • Kim, Hwan Gi;Kwon, Moon Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.35-44
    • /
    • 1986
  • This paper is a basic study of the experimental results for the treatment of ammonia-nitrogen in the septic tank effluent. The substrates in this experiment are actual septic tank effluent and synthetic waste-water which is similar to septic tank effluent containing a considerable amount of nitrogenous component. Experiments were conducted for organic removal and nitrification using various recycle ratio and hydraulic retention time at each stage. The results obtained show that organic removal rate was above 80% in the 1st and 2nd stage, but as nitrification process was proceeded, above 90% of ammonia-nitrogen was removed in the 3rd and 4th stage. In these cases, the recycle ratio and HRT were found 30 and 7 hrs respectively. In the relation of $NH_4{^+}-N$ removal to $NO_3{^-}-N$ formation in the synthetic waste-water and septic tank effluent, when $1mg/{\ell}$ of $NH_4{^+}-N$ was removed, $NO_3{^-}-N$ formations were $0.95mg/{\ell}$ and $0.82mg/{\ell}$ respectively. And kinetics of nitrification using Biological Fluidized Bed was discussed also.

  • PDF

A Case Study on Cost-Benefit Analysis of the Septic Tank and Exclusive Sewage Pipe Line in Designing the large Building at Combined Sewer District (합류식 하수도 지역에 대형 건축물 설계시 정화조 및 전용오수관로의 비용편익분석 사례연구)

  • Oh, Hyun-Taek;Kim, Sung-Tai;Lim, Byung-In;Kang, Byong-Jun;Park, Kyoo-Hong
    • Journal of Digital Convergence
    • /
    • v.17 no.6
    • /
    • pp.169-175
    • /
    • 2019
  • The aim of this study is to examine the relative economic benefits between the septic tank and exclusive sewage pipe line in designing the large building at combined sewer districts. With the case study of Lotte World Tower Building, we analyze a cost-benefit between two alternatives. The research results showed 2 years of payback period, about ₩6.17 billion of NPV, and 1.93 of B/C ratio for installing the exclusive sewage pipe line in comparison with septic tank. This results provide useful guidelines for policy establishment of the septic tank closure and for plausibility of installing exclusive sewage pipe line when constructing a large building. In the future, it will be necessary to consider additional cost-benefit analysis including burden charge borne by causers, the burden of management responsibility with a exclusive sewage pipe line, and the economic benefits of reducing odor.