Search Result 74, Processing Time 0.028 seconds

Electrostatic discharge simulation of tunneling magnetoresistance devices (터널링 자기저항 소자의 정전기 방전 시뮬레이션)

  • Park, S.Y.;Choi, Y.B.;Jo, S.C.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.5
    • /
    • pp.168-173
    • /
    • 2002
  • Electrostatic discharge characteristics were studied by connecting human body model (HBM) with tunneling magnetoresistance (TMR) device in this research. TMR samples were converted into electrical equivalent circuit with HBM and it was simulated utilizing PSPICE. Discharge characteristics were observed by changing the component values of the junction model in this equivalent circuit. The results show that resistance and capacitance of the TMR junction were determinative components that dominate the sensitivity of the electrostatic discharge(ESD). Reducing the resistance oi the junction area and lead line is more profitable to increase the recording density rather than increasing the capacitance to improve the endurance for ESD events. Endurance at DC state was performed by checking breakdown and failure voltages for applied DC voltage. HBM voltage that a TMR device could endure was estimated when the DC failure voltage was regarded as the HBM failure voltage.

Flame Propagations of Gasoline-Air Mixtures by Electrostatic Discharge Energies (정전기 방전에너지에 따른 가솔린-공기 혼합물의 화염전파)

  • Park, Dal-Jae;Kim, Nam-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.6-10
    • /
    • 2011
  • Experimental studies were carried out to investigate the effects on flame propagation of gasoline-air mixtures by different electrostatic discharge energies in a cylindrical chamber. Three different ignition energies were used: 1 mJ, 50 mJ and 98 mJ. In this work, a high-speed particle image velocimetry technique was applied to visualize the flow-field around ignition electrodes. It was found that as the ignition energy increased, the ignition kernel was different. The different ignition kernel caused different flame initiation. During the flame initiation, the higher ignition energy was applied, the higher flame speed was observed. However, with increasing time, the flame speeds were independent of the ignition energies used. Theses observed flame behaviors were similar to computational simulations shown in the literature. It was also found that as the ignition energies increased, the velocities of unburnt mixtures ahead of propagating flame fronts increased.

정전기수력학 인쇄방법에 있어서 잉크 액적의 전하량 및 인가 전기장에 따른 거동 연구

  • Lee, Hyeon-Ju;Lee, Gyeong-Il;Lee, Cheol-Seung;Kim, Seon-Min;Kim, Seong-Hyeon;Byeon, Sang-Eon;Jo, Jin-U;Choe, Yeong-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.187-187
    • /
    • 2011
  • 최근 디스플레이 산업과 태양전지 등의 이차 전지 산업이 발달함에 따라 원가절감과 공정단계의 단순화를 위하여 다이렉트 패터닝 인쇄에 대한 연구가 관심을 받고 있으며, 나노전자부품 제작이 요구되는 전기/전자 소자들은 수백 nm에서부터 수십 ${\mu}$m 수준까지 다양한 해상도의 패턴으로 구성되므로 미세패턴이 가능한 정전수력학 잉크젯프린팅 방식은 기존의 인쇄 방식과 달리, 정전기력을 이용하여 인쇄를 하는 방식으로, 수KV의 고전압을 인가하여 잉크를 대전시키고, 대전된 잉크는 대부의 전기적 반발력에 의해 액적이나 액실로 분열하게 된다. 전하를 띤 액적 또는 액실은 정전기력을 받아 기판 쪽으로 이동을 하게 되는데, 이때 액적의 전하량에 의해 액적의 이동속도와 이동경로가 영향을 받게 된다. 본 연구에서는 잉크의 전기전도도에 따른 액적의 전하량을 계산하여 전기전도도와 액적의 전하량과의 관계를 ANASYS 시뮬레이션과 운동경로 분석을 통해 확인하였다. 전기전도도가 0.307s/m~5.6s/m인 잉크에 따른 액적의 전하량을 계산하였으며, 전기전도도가 변화에 따라. 전하량이 $0.5{\times}10^{-13}C{\sim}2.5{\times}10^{-13}C$ 으로 변화하는 것을 확인하였다.

  • PDF

Operating System Design of Multi Beam Control System with Miniaturized Electron Beam Columns (초소형 전자빔을 이용한 멀티 전자빔 운영 시스템 설계)

  • Lim, Sun Jong;Kim, Ho Seob
    • Laser Solutions
    • /
    • v.18 no.4
    • /
    • pp.12-16
    • /
    • 2015
  • The research on multi electron beam systems is being carried out by various methods. We are studying multi electron beam system using miniaturized electron beam columns. The column consists of electrostatic lenses, electrostatic deflector and tip emitter. Our operating system controls 4 column array, captures images of each column and maintains the instrument. We present the usefulness of our operating system for multi columns by capturing images of each column.

A study on the explosion proof by the electric discharge on voltage application type (전압인가식 제전기의 방폭화에 관한 연구)

  • Lee Chun Ha;Kim Jum Ho;Park Min Young
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.62-69
    • /
    • 2004
  • It is necessary to eliminate the electric static for the prevention of disasters by electric static discharge, the improvement of production efficiency, the protection of a sensitive electronic devices in the variable manufacturing processes. Then it is handled for elimination of electric static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the ideal condition of electric static elimination efficiency by changing of the length of voltage input type eliminator's bar, the length of copper pipe and the gap of electrode and the existence of explosion by inflammable gas with that conditions. As the result, the electric static elimination efficiency has the most ideal value at the 8-11(mm) gap of the earth electrode and needle type electrode each elimination bar and there is not explode at the explosive experiment of inflammable gas with the ideal elimination bar. We can consider that there are some data which are needed for elimination efficiency and it will be able to protect the occurrence of explosion accident inflammable nas in the industrial fields.

  • PDF

Reaction Characteristics Study of Aluminum-Copper(II) Oxide Composites Initiated by the Electrostatic Discharge (Aluminum-Copper(II) Oxide Composite의 정전기에 의한 반응 특성 연구)

  • Kim, Minjun;Kim, Sung Ho;Kim, Jayoung;Im, Yeseul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.591-598
    • /
    • 2018
  • The reaction characteristics of aluminum-copper(II) oxide composites initiated by the electrostatic discharge were studied as changing the aluminum particle size. Three different sizes of aluminum particles with nano-size copper(II)-oxide particle were used in the study. These composites were manufactured by two methods i.e. a shock-gel method and a self-assembly method. The larger aluminum particle size was, the less sensitive and less violent these composites were based on the electrostatic test. On the analysis of high speed camera about ignition appearances and burning time, the burning speed was faster when aluminum particle size was smaller.

Electric Propulsion (전기 추진)

  • Moon, Hee-Jang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.3
    • /
    • pp.76-86
    • /
    • 2008
  • The EP(electric propulsion) is unique in that several energy sources can be utilized to produce the electric energy and that high exhaust velocity can be achieved compared to the conventional chemical propulsion. Though a lot of variety of non chemical propulsion are under study, the fact that the EP's specific impulse ranges widely from 200s to 5000s led most research to concentrate on the electric propulsion research. This paper, therefore, is aimed to introduce the up-todate existing EP family such as electrothermal, electrostatic and electromagnetic thrusters where its operating concepts, characteristics and possible variants are presented for future applications.

The Ion Generation Characteristics of Charge Neutralizer Applied a Pulse Voltage (펄스전압을 적용한 전하중화장치의 이온발생 특성)

  • Moon, Jae-Duk;Chung, Suk-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.140-146
    • /
    • 1998
  • Methods and systems to remove static electricity are requested necessarily because the static electricity causes a flammable gas explosion, a fire, reduction of production rate in manufacturing VLSI semiconductor device and so on. In this paper, abrasion and dust contaminant of needle electrode are studied experimentally. And, frequencies and pulse durations of a high frequency pulse source were controlled effectively to minimize the abrasion of needle electrode and control generated numbers of ions. As a result, it is verified experimentally that the ion generation of charge neutralizer increases by using a high frequency pulse source.

  • PDF

Cost Effective Fabrication of a Triboelectric Energy Harvester Using Soft Lithography (소프트 식각법을 이용한 효율적 제작방식의 마찰전기 에너지 수확소자 개발)

  • Lee, Jun-Young;Sung, Tae-Hoon;Yeo, Jong-Souk
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.4
    • /
    • pp.198-203
    • /
    • 2013
  • Energy harvesting refers to converting ambient energy from our surroundings, which would be otherwise wasted, into useful electrical energy. A triboelectric energy harvester is a self-charged device for harnessing mechanical energy based on a coupled process of contact charging and electrostatic induction. In this research, we demonstrate simple fabrication of prototype triboelectric energy harvester using soft lithography and its electrical characterization. Triboelectric generation occurs between the two micro patterned layers of Au and PDMS. A micro pattern is simply replicated directly from the bottom layer to the top layer using soft-lithography without an extra transfer process. This generator can produce an output voltage of 2 V and output current of 20 nA.

Studies on Electrostatic Propensity of Fabrics (직물대전성에 관한 연구)

  • 최병희;배도규
    • Journal of Sericultural and Entomological Science
    • /
    • v.27 no.2
    • /
    • pp.54-63
    • /
    • 1985
  • This studies has been carried out how to effect on electrostafic propensity of synthetic fabrics by coating with 0.5% acrylic polymer solution which was previously developed by the author to improve anticrease nature of silk. The work conditions are: (A) Applied synthetic polymer was acrylic polymer 525, developed by the author. (B) Electrostatic voltage for various fabrics were carried out by Korea standard abrasion partner with Korea standard (KS K 0905) cotton, nylon, polyester and the self sample fabric. (C) Applied fabrics for the investigations were carried out by using abrasion partner with Korea standard (KS K 0905) cotton, nylon, polyester and the self sample fabric. (D) Electrostatic propensity investigations were carried out by use of sample as silk, nylon, polyester and acrylic fabrics, seperating before finish or after finish. (E) Washing after the finish or the original fabric was carried out by Korea standard method, KS K 0465. Through the investigations, he happened to find many interesting matters and the obtained results are as followings. 1. Electrostatic voltage for the finished fabrics increased more than their original silk, nylon, acrylic fabrics except polyester fabric. (See Table 5) 2. Electrostatic voltage for the finished polyester against K.S. polyester decreased remarkably than the original fabric test. 3. In spite of no problem on electrostatic propensity of silk, it showed high electrostatic voltage between the same nature fabric abrasion, because silk is very weak against abrasion and because the test method had been developed to be useful for only synthetic fabrics. 4. Electrostatic voltage increased more in case of abrasion between different nature of fabrics than the same nature of fabrics. 5. Electrostatic voltage of each fabric increased by repeat of wash. 6. Many investigation data were followed with Contact Electrification Series Principle, another word, the farther each other located fabric on the series abrasion was, the higher electrostatic voltage. (See Fig. 6) 7. Such investigation gives warning of use on the mix fiber spinning service as far as concern with electrification. 8. It may also call attention for such increase of electrification in case any finishing of silk textile.

  • PDF