Kim, Doo Kie;Kim, Dong Hyawn;Seo, Hyeong Yeol;Lee, Chang Ju
Journal of the Korea institute for structural maintenance and inspection
/
v.11
no.5
/
pp.107-113
/
2007
This study presents fragility curves for the wind fragility analysis of a six-span extradosed bridge. The loads and corresponding load combinations are calculated using domestic design codes. Random variables are utilized to considering the uncertainties of the input variables for wind loads. The fragility curve is represented as a log-normal distribution function, in which two parameters are estimated by the maximum likelihood method. The results show that the extradosed bridge is safe to suffer static wind forces.
Journal of Korean Association for Spatial Structures
/
v.6
no.1
s.19
/
pp.83-90
/
2006
The GF(Gust Factor) method is usually used as a method to evaluate equivalent static wind loads for general structures. The GF method is performed on the assumption that the shape of the equivalent static wind load profile is typically similar to that of mean wind loads. The shape of fluctuating wind loads could be quite different with that of the mean wind loads in case of large-span structures. So, the effect of higher modes as well as first mode must be considered to evaluate the wind loads. In this study, the ACS (Advanced Conditional Sampling) method is suggested to evaluate of equivalent static wind loads after investigating about GF and LRC method. The An method ran derive effective static wind loads by combining wind pressures and inertia forces of a structure chosen at a maximum load effect. The maximum load effect is assessed with the time history analysis using pressure data measured in wind tunnel tests. Equivalent static wind loads evaluated using ACS, GF, and LRC methods are compared to verify the effectiveness of ACS method.
Journal of the Computational Structural Engineering Institute of Korea
/
v.19
no.4
s.74
/
pp.369-374
/
2006
This paper describes dynamic characteristics of a power transmission tower consisting of lots of power lines and insulators. A numerical 3D modeling for the static, dynamic and buckling analyses of the power transmission tower is presented considering the case when the power lines are cut. Eigenvalue analysis indicates that the transmission tower shows different behavior comparing to usual structures governed by several low modes. The transmission tower is governed by lots of modes. It is verified that the transmission tower is structurally safe against the static wind and buckling loads. But the structural and buckling safety is not guaranteed when all power lines are cut, which comes to collapse the transmission tower. Further study is in need to overcome such case. Wind dynamic analysis shows that fluctuating wind loads increase the response of the tower.
Proceedings of the Computational Structural Engineering Institute Conference
/
2011.04a
/
pp.218-221
/
2011
본 연구에서는 추계학적 해석을 통하여 구한 교량의 동적 변위와 동일한 변위를 발생시키는 등가 정적 버페팅 하중을 구하는 방법을 제시하고, 단순 양단 캔틸레버에 적용하여 타당성을 검증하였다. 모드 형상이 복잡한 사장교의 경우에 2개 이상의 모드를 포함해야 정확도를 높일 수 있는 것으로 나타났다.
KSCE Journal of Civil and Environmental Engineering Research
/
v.4
no.4
/
pp.59-66
/
1984
The dynamic behavior of a cable-stayed bridge due to random wind forces is investigated. The effects of the steady wind, the self-excited and the buffeting forces are studied. The dynamic analysis of the structure is carried out by the frequency domain method utilizing the mode superposition. Example analysis are performed for Dolsan Bridge, which is under construction at Yeosu, Jeonnam. Aerodynamic stability of the bridge is investigated and the vertical motion of the girder as well as the tension variations of the cables is obtained.
Proceedings of the Computational Structural Engineering Institute Conference
/
2011.04a
/
pp.84-87
/
2011
본 연구에서는 버페팅 해석을 통해 현수교 캣워크에 작용하는 풍하중에 대한 정적 및 동적 응답을 알아 보고 진동 억제 대책을 제시하였다. 캣워크는 영구구조물이 아닌 임시구조물이기 때문에 그동안 절적한 평가가 수행되지 못하였다. 따라서 본 연구는 풍하중에 의한 캣워크의 동적 응답을 해석적인 방법을 통해 알아보았으며, 동적 변위를 산정하기 위해 시간이력 해석 방법을 통해 버페팅 해석을 수행하였다. 그 결과로 부터 캣워크의 수평변위를 억제하기 위해 주케이블을 시공중에 연결하는 방법과 스테이 로프를 설치하는 방법을 제시하였다.
Journal of the Korea institute for structural maintenance and inspection
/
v.26
no.5
/
pp.10-19
/
2022
Irregularity in structural shape is a ubiquitous phenomenon. Structural hazards evoked from irregularity need to be checked against extreme lateral loadings. Structures containing four distinct types of irregularities in terms of continuity and discontinuity in upper half-length and all story levels along with O-shape are investigated. The structures were analyzed numerically and different seismic responses such as displacements, bending moment, axial forces, torsions, story drift, etc. were scrutinized. The seismic and wind load analysis was conducted for ACI 318-11 conditions. Results show that buildings having discontinuous beams on the upper half exhibit better resilience. It is also concluded that O-shaped building structures provide better resistance to overturning, making this shape relatively safe.
Lee, Han Kyu;Kim, Jong Hwa;Lee, Seung-Ho;Kwon, Soon-Duck
한국방재학회:학술대회논문집
/
2011.02a
/
pp.71-71
/
2011
캣워크는 현수교의 주케이블을 가설을 위해 일시적으로 설치하는 공중작업발판으로 주케이블 가설장비와 작업원 등의 하중을 지지한다. 캣워크는 유연한 구조물로서 풍하중에 상당한 변형이 발생한다. 하지만, 국내외를 막론하고 캣워크의 내풍안정성에 대한 연구는 별로 이루어지지 않았다. 거기에 더하여 캣워크에 작용하는 정적 공기력에 대한 정보도 부족하며, 현재 캣워크 단면에 대한 적절한 풍하중을 산정하지 못하고 경험적인 설계가 이루어지고 있다. 따라서 캣워크의 효율적인 내풍설계를 위하여 풍동실험을 통한 충실률과 공기력계수와의 관계를 알아보는 것이 필요하다. 이를 위하여 축척 1/4인 모형을 사용한 풍동실험을 통하여 메쉬망의 크기를 변화시키면서 충실률에 따른 공기력계수를 측정하고 설계식을 제안하고자 한다. 캣워크는 로프와 아울러 가는 철망으로 아래와 양 옆이 막혀 있다. 즉 바람을 직접 받는 부분인 철망은 가는 원형단면으로 구성되어 있다. 원형 단면의 경우에 레이놀즈 수에 따라 항력계수가 크게 변하는 것으로 알려져 있다. 그러나 가는 원형 단면으로 둘러싸인 캣워크의 항력계수에 레이놀즈 수가 미치는 영향에 대해서는 연구된 바가 없다. 본 연구에서는 캣워크의 공기력계수에 미치는 레이놀즈 수에 대한 영향을 파악하고자 1/4모형과 1/14모형을 제작하여 최대풍속 30m/s까지 변화시켜가면서 공기력계수를 측정하였다. 이때 레이놀즈 수는 최대 20배까지 차이가 나므로 만약 공기력계수가 레이놀즈 수의 영향을 받는다면 확실히 그 영향을 파악할 수 있다. 본 연구에서는 풍동실험을 통해 충실률과 공기력계수와의 관계과 레이놀즈 수의 영향을 살펴보았으며, 정적공기력 계수의 설계식을 제안하였다. 본 연구를 통하여 얻은 결과를 정리하면 다음과 같다. 1. 축척 1/14 및 1/4 모형을 사용하여 다양한 풍속에서 공기력계수를 측정한 결과, 캣워크에 작용하는 정적 공기력계수는 레이놀즈 수의 영향을 받지 않는 것으로 나타났다. 따라서 향후 새로운 형식의 캣워크에 대한 풍동실험을 수행할 경우에 축척에 상관없이 풍동실험 결과를 사용할 수 있을 것으로 판단된다. 2. 풍동실험 결과, 캣워크에 작용하는 정적 공기력계수 중 항력계수와 피칭모멘트계수는 측면 충실률에 따라 달라지고, 영각에 대한 양력계수의 기울기는 하부 충실률의 영향을 받는 것으로 나타났다. 그리고 주케이블이 캣워크 내부에 위치하고 있어도 캣워크의 정적 공기력계수에는 큰 영향을 미치지 않은 것으로 측정되었다. 이를 정리하여 캣워크 충실률에 따른 정적 공기력계수의 추정식을 제안하였다.
As a link composition of a double link type level luffing jib crane was determinated through the link composition design, the design to be considered will be computations of the luffing trajectory deviation at the fly jib tip and the required luffing device capacity. This paper is a study regarding the static and dynamic analysis for a mechanism of the crane. The objective of the static analysis is to determinate the capacity and the dimension of luffing device when the crane selfload, rated hoisting load, wind load and inertia force are applied on the crane. The objective of dynamic analysis is to compute the luffing trajectory deviation, velocity and inertia force due to luffing acceleration for each link. All analyses are performed by computer programs. The reliability of the program was checked by results from analyses of the related commercial package. It is expected that the productivity and reliability of the design can be improved by this program which can rapidly and exactly deal with static and dynamic analysis for a given link composition of the crane.
Journal of Korean Society of Coastal and Ocean Engineers
/
v.26
no.1
/
pp.33-40
/
2014
Reliability analysis of jacket type offshore wind turbine (OWT) support structure under extreme ocean environmental loads was performed. Limit state function (LSF) of OWF support structure is defined by using structural dynamic response at mud-line. Then, the dynamic response is expressed as the static response multiplied by dynamic response factor (DRF). Probabilistic distribution of DRF is found from response time history under design significant wave load. Band limited beta distribution is used for internal friction angle of ground soil. Wind load is obtained in the form of thrust force from commercial code called GH_Bladed and then, applied to tower hub as random load. In a numerical example, the response surface method (RSM) is used to express LSF of jacket type support structure for 5MW OWF. Reliability index is found using first order reliability method (FORM).
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.