• Title/Summary/Keyword: 정적재하 실험

Search Result 149, Processing Time 0.031 seconds

Detection of Manufacturing Defects in Stiffness of CFTA Girder using Static Loading (정적 시험을 사용한 CFTA거더의 제조시 강성 결함 탐색)

  • Kim, Doo-Kie;Alfahdawi, Nathem;Cui, Jintao;Park, Kyung-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.1
    • /
    • pp.109-116
    • /
    • 2012
  • This paper presents a study on the nonlinear behavior of an innovative bridge girder made from concrete-filled and tied tubular steel arch (CFTA) under static loading. Manufacturing of the CFTA girder may have defects which may highly affect the symmetry and performance of the structure. A simple method is proposed by using stiffness extracted from static test data to detect manufacturing defects of the CFTA girder. A three-dimensional finite element model was used in the numerical analysis in order to verify the method. The proposed method was experimentally validated through static tests of the CFTA girder. The application of the proposed method showed that it is effective in identifying invisible manufacturing defects of the CFTA girder, especially for mass production of a standard type in the factory.

On Quasi-Static Crushing of a Stiffened Square Tube (보강된 정사각형 단면 강관의 정적 압괴거동에 관한 연구)

  • Paik, Jeom Kee;Chung, Jang Young;Chun, Min Sung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.109-123
    • /
    • 1996
  • A series of quasi-static crushing tests were carried out on thin-walled square tube specimens with axial and/or circumferential stiffeners including unstiffened specimens. The effective crushing length and mean crushing strength of the test specimens were investigated. Using the equivalent plate thickness approach, a simplified analytical model for predicting the mean crushing strength of stiffened square tubes has been developed.

  • PDF

Fatigue Capacity of Concrete Beams Prestressed with Partially Bonded CFRP Tendons (CFRP 긴장재로 긴장된 부분비부착 콘크리트 보의 피로 성능)

  • Jeong, Sang-Mo;Lee, Cha-Don;Park, Sang-Yeol;Jeong, Yo-Sok;Park, Dong-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.333-336
    • /
    • 2008
  • CFRP tendons have been attempted in concrete structures as a substitute for steel tendons considering their many advantages such as the corrosion-resistance, light weight etc. However, the elastic behavior up to failure is likely to result in ductility problems. To overcome such problems, prestress concrete beams with partially bonded tendons have been developed and suggested. In this new system, the un-bonded part near the mid-span contributes to the improvement of ductility. And the bonded parts at both ends play a role as a safe anchorage. According to the previous research on the static behavior, the suggested method has demonstrated enough ductility and strength. However it is essential to verify the long-term safety for repetitive fatigue loads under service states. For this purpose, flexural fatigue loading tests were carried out in this research. This paper includes an experimental investigation on the static load-carrying capacities of the beams with or without fatigue tests. The results showed that the beams prestressed with partially bonded CFRP tendons possessed good fatigue capacity under the constant cyclic loads.

  • PDF

Initial Imperfection Sencitivity in Stiffened Plates (보강판의 초기결함 민감성 연구)

  • 김천욱;원종진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.3
    • /
    • pp.264-273
    • /
    • 1984
  • 초기경향이 있는 보강평판의 비선형 운동 방정식을 Galerkin method에 의하여 유도하였다. Runge Kutta method를 사용하여 step-load를 받고 있는 보강평판의 동적 좌굴문제의 수치해를 구하였다. 정적 좌굴실험에 의하여 좌굴하중을 결정함에 있어 동적 해석법을 응용할 수 있음을 입증하였으며, step-load를 받는 보강평판의 동적 좌굴해석으로 정적좌굴의 초기결함 민감성을 해 석하였다. 보강평판의 초기결함민강성은 평판보다 훨씬 낮으며 보강재의 편심비가 높을수록 민감 성은 둔화된다.

Static Behavior of Concrete-Filled and Tied Steel Tubular Arch(CFTA) Girder (CFTA거더의 정적 거동연구)

  • Kim, Jong-In;Kim, Doo-kie;Lee, Jang-hyeong;Kim, Jeong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.225-231
    • /
    • 2009
  • This study introduces the CFTA girder(Concrete-Filled and Tied Steel Tubular Arch Girder) which is a combined structural system of traditional CFT, arch, and prestress structures. Static load tests and structural behavior analyses were carried out for a 25m long CFTA girder. In the analysis, each load of 58kN, 88kN, 148kN, 207kN,and 298kN was applied incrementally at the positions of 1.0 m distances in both directions from the center of the girder. On each test, strain and displacement were measured. Linear static FEM analyses using Strand7 code were also performed to check the structural stability and to investigate the effects of prestressing(${\pm}$20%) and material property(Young's modulus) on the displacement and strain. The results of this study are summarized as follows: the initial strain & displacement under selfweight and prestressing were influenced with the variation of prestressing, but they were mainly effected only by Young's modulus when additional loads were applied.

An Experimental Study on High Angle of Attack Static Stability Analysis For the Aerodynamic Design of Canard Type High Maneuver Aircraft (카나드 형상 고시동 항공기 공력설계를 우한 높은 받음각 정적 안정성 분석 실험 연구)

  • Chung, In-Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.7
    • /
    • pp.575-580
    • /
    • 2007
  • During the conceptual design phase of a canard type high maneuverable aircraft, the low speed small scale wind tunnel test was conducted to investigate the high angle-of-attack static stability of the aircraft. In this study, 1/50th scale generic canard-body-wing model was used for the small scale wind tunnel test. For the analysis of static stability including high angle-of-attack nonlinear characteristics, the vertical tail effects were studied due to canard deflections. In addition, the nose chine effects were studied at high angle-of-attack. Based on the results obtained from the experimental study, the configuration change effects for canard type aircraft on high angle-of-attack static stability have been able to analyze.

An Experimental study on Shear Resisting Effect of Reinforced Concrete Beams Filling-up Carbon Fiber Rod Plastic (CFRP-Rod로 전단 보강된 철근콘크리트 보의 전단거동에 관한 실험적 연구)

  • Kim, Young-Sik;Park, Sung-Moo
    • Proceeding of KASS Symposium
    • /
    • 2005.05a
    • /
    • pp.183-190
    • /
    • 2005
  • The purpose of this study is to investigate experimentally the shear resisting behavior of the reinforced concrete beams strengthened with reinforcement materials(CFRP). Five specimens were manufactured and tested under, static monotonic loading. The main variables In the test were a space and volume of reinforcement. The test result indicated that the method of CFRP increase significantly the shear strength of a reinforced concrete beam

  • PDF

Centrifugal Test on Behavior of the Dolphin Structure under Ship Collision (선박충돌 시 돌핀 구조물의 거동에 대한 원심모형실험)

  • Oh, SeungTak;Bae, WooSeok;Cho, SungMin;Heo, Yol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.1
    • /
    • pp.61-70
    • /
    • 2011
  • The impact protection system consists of an arrangement of circular sheet pile cofferdams-denoted dolphin structuredeeply embedded in the seabed, filled with crushed rock and closed at the top with a robust concrete cap. Centrifuge model tests were performed to investigation the behaviors of dolphins in this study. Total 7 quasi-model tests and 11 dynamic model tests were performed. The main experimental results can be summarized as follows. Firstly, The experimental force-displacement results for quasi-static tests show a limited influence on the initial stiffness of the structure from the change in fill density and the related change in the stiffness of the fill. And by comparing the dissipation at the same dolphin displacement it was found that the denser fill increase the dissipation by 16% for the 20m dolphin and by 23% for the 30m dolphin. The larger sensitivity for the large dolphin is explained by a larger contribution to the dissipation from strain in the fill. In low level impacts the dynamic force-response is up to 26~58% larger than the quasi-static and the dissipation response is showed larger in small displacement. Hence, it is concluded conservative to use the quasi-static response characteristics in the approximation of the response, and it is further concluded that the dolphin resistance to low level impacts is demonstrated to be equivalent and even superior to the high level impacts.

Structural Performance Verification of RDT Girder Bridge Feasible to Fill with Planting Ground (식재기반을 담는 RDT 거더교의 구조성능 검증)

  • Ha, Tae-Yul;Han, Jong-Wook;Yang, In-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2219-2228
    • /
    • 2015
  • The proposed RDT(Reversed Double T) girder bridge is suitable to eco corridor, because of its cross section which resembles Korean alphabet vowel "ㅛ". The total height and cost of bridge would be reduced for its inner space containing some of plant soil. In this study, the performance of the RDT girder was assessed by comparing results of static test with those of nonlinear analysis. The cracking load of the RDT girder was evaluated more than two times of design load.

Experimental study on Static Behavior of H-beam prestressed with Multi-Stepwise TPSM (다단계 온도프리스트레싱 도입 강재보의 정적거동평가를 위한 실험적 연구)

  • An, Jin Hee;Jung, Chi Young;Kim, Jun Hwan;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.247-258
    • /
    • 2008
  • In this study, static loading tests were performed on H-beam specimens to assess the static behavior of H-beam prestressed with multi-stepwise thermal prestressing method (TPSM). The amount of induced thermal prestress and connection type were differentiated among the 400-mm-high and 6,000-mm-long H-beam specimens to evaluate their effect on the behavior of the beams. From the experimental results, it between the H-beam and the cover-plate increased in yielding load by 13~18%, whereas stiffness increased by 27~34%. In case of specimens with both bolting and welding connection, yie lding load increased by 18~29% and stiffness increased by 43~51%. Multi-stepwise initial stress distribution was also observed from the prestressed specimens, verifying the effectiveness of the multi-stepwise TPSM. By application of the multi-stepwise TPSM, a significant increase in yielding load and stiffness can be achieved, hence increasing sectional and prestressing efficiencies.