• Title/Summary/Keyword: 정적재하실험

Search Result 118, Processing Time 0.033 seconds

Seismic Performance of Concrete-Filled Steel Piers Part I : Quasi-Static Cyclic Loading Test (강합성교각의 내진성능평가 Part I : 준정적 반복재하실험)

  • 조창빈;서진환;장승필
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.9-19
    • /
    • 2002
  • Steel piers and concrete-filled steel(CFS) piers, in spite of reasonable strength, high ductility, small section, and fast construction, have not been considered as one of alternatives to RC piers even in the highly populated urban area where aseismic safety, limited space and fast construction are indispensably required. This paper, the first of two companion papers for the seismic performance of steel and CFS piers, tests steel and CFS piers under quasi-static cyclic loading to estimate their ductility and strength. Additional details such as rebars and base ribs are added to increase the ductility of a concrete-filled steel pier with minimum additional cost. Also, simplified numerical analyses using nonlinear spring and shell elements are examined for the estimation of the ductility and strength of concrete-filled steel piers and a steel pier. The result shows that concrete-filled steel peirs have higher energy absorption, i.e., ductility and strength than those of steel pier and increasing bonding between in-filled concrete and lower diaphragm, and the improved details of stress concentrated region would be important for the ductility and strength of a pier. Numerical results show that simplified modeling with nonlinear springs and shells has potential to be effective modeling technique to estimate the seismic performance of a concrete-filled steel pier.

Analytical Study on the Pullout Resistance Characteristics of Bored Pile (매입말뚝의 인발저항특성에 관한 연구)

  • Park, Jong-Bae;Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.281-289
    • /
    • 2016
  • Structural experiment result showed that PHC(d=600mm) Pile used as a common compression member could resist 83.6 ~ 91.6 tonf of ultimate tension force, if the adhesion of P.C. bar of PHC pile to the concrete foundation is strengthened. Considering a proper safety factor to ultimate tension strength, PHC pile can substitute the anti-floating anchor, or reduce the number of anchors. For this purpose, pullout resistance behavior of a Bored pile embedded in real ground as well as structural tension strength of PHC pile must be evaluated. This study performed the static pullout tests to evaluate the pullout behavior of bored pile, and compared the test results with design value of side resistance. To evaluate the pullout resistance easily, static pullout test results were compared with dynamic loading test results using PDA. As a result, cement paste of the bored pile was hardened which is after 15 days, LH side resistance design value corresponded well to the Static pullout test results, also to the side resistance evaluated by dynamic loading test.

Experimental Study on Behaviors of Prestressed Concrete Beam Reinforced by Prestressed External Tendon (단면 보강용 외부 긴장 강선을 사용한 프리스트레스트 콘크리트 보의 거동에 관한 실험적 연구)

  • Park, Chan-Sol;Kim, Kee-Dong;Han, Taek-Hee;Latif, Abdul;Kim, Doo-Kie
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.222-229
    • /
    • 2022
  • The extensive use of external prestressing system with PSC-I beam to strengthen reinforced and prestressed concrete members requires the full understanding of the behavior of the strengthened members. The main approach of this research was to experimentally investigate the flexural performance of the PSC-I beam considering external tendon and an equation was developed which indicated the produced incremental stress in the tendon due to applied load. Further, this equation was verified through performing static loading tests on two experimental specimens considering the presence or absence of external tendon. The test results revealed that, the flexural performance enhanced due to the use of external tendon. Moreover, the magnitude of the estimated flexural strength using proposed stress increasing equation almost coincides with the experimental test results. However, it was the evident of the improvement of the flexural performance of the system by reinforcing with the external tendon and also proved that the proposed equation was valid and effective.

Experimental Study on the Inelastic Behavior of Single-layer Latticed Dome (단층 래티스 돔의 비탄성 거동에 대한 실험연구)

  • Kim, Jong-Soo;Kim, Sang-Dae;Kim, Myeong-Han;Oh, Myoung-Ho;Shin, Chang-Hoon
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.165-170
    • /
    • 2008
  • This study discusses the inelastic behavior of single-layer latticed dome, composed of tubular truss member and newly proposed joint sections, through loading test on the scale-down structure. The loading test was performed under displacement control conditions, using loading transfer system for the same value of point loads on all joints. Maximum applied load was nearly 1.6 times of the design load, and inelastic buckling occured beyond compressive yeilding in some members. The displacement of structure was maimtained upto the limit of oil jack. The behavior of latticed dome from the loading test was analyzed on the view of structural design practice.

  • PDF

Experimental Evaluation for Ultimate Flexural Behaviors of PSC beams with A Corroded Tendon (PS강연선이 부식된 PSC보의 극한휨거동 평가실험)

  • Youn, Seok-Goo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.843-854
    • /
    • 2013
  • This paper presents experimental research work for the evaluation of ultimate flexural behaviors of prestressed concrete beams with a corroded tendon. In order to evaluate the effects of loss of prestress or loss of tendon area on the ultimate flexural strength of prestressed concrete beams, static load tests are conducted using five prestressed concrete beams. After exposing prestressing tendons in two test beams using 25mm drill bit, the exposed tendons were corroded using an accelerating corrosion equipment to simulate loss of tendon area. During the tests, steel strains, concrete strains and displacements at the center of test beams were measured, and acoustic emission measurements were conducted to detect wire fractures. Based on the test results, evaluation method for predicting flexural strength of prestressed concrete beams with corroded tendons is investigated. In addition, evaluation methods for predicting the existence of corroded tendons in post-tensioned prestressed concrete beams at service loads are discussed.

Experiments on Flexural Performance of Composite Members Strengthened by External Steel Plates (외부 강재 보강으로 구성한 합성 부재의 휨 성능에 대한 실험)

  • Hwang, Byung-Hun;Shin, Jin-Won;Jeon, Jae-Ho;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.143-150
    • /
    • 2022
  • This paper presents an experimental study on the flexural performance of concrete members strengthened with external steel plates for the purpose of improving seismic performance. In order to strengthen the structure, a strengthening method was applied that wraps the walls and columns with steel members. The partial section of the wall with the longest span in the structure was manufactured in real size and the strengthening effect was confirmed by performing a static load test. As a result of the experiment, it was confirmed that the strengthened section exhibited sufficient flexural performance satisfied to the seismic requirements, but the behavior until failure was not obtained because of actuator capacity. It was confirmed that the strengthened member resists the out-of-plane moment with a composite behavior. It was verified that the stiffness and load carrying capacity of the strengthened member were improved compared to the non-strengthened member by displacement and strain measurements.

Comparison of Lateral Pile Behavior under Static and Dynamic Loading by Centrifuge Tests (원심모형 실험을 이용한 지반-말뚝 상호작용의 정적 및 동적 거동 평가)

  • Yoo, Min-Taek;Kwon, Sun-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.7
    • /
    • pp.51-58
    • /
    • 2018
  • In this study a series of centrifuge tests were carried out in dry sand to analyze the comparison of lateral pile behavior for static loading and dynamic loading condition. In case of static loading condition, the lateral displacement was applied up to 50% of pile diameter by deflection control method. And the input sine wave of 0.1 g~0.4 g amplitude and 1 Hz frequency was applied at the base of the soil box using shaking table for dynamic loading condition. From comparison of experimental static p-y curve obtained from static loading tests with API p-y curves, API p-y curves can predict well within 20% error the ultimate subgrade reaction force of static loading condition. The ultimate subgrade reaction force of experimental dynamic p-y curve is 5 times larger than that of API p-y curves and experimental static p-y curves. Therefore, pseudo-static analysis applied to existing p-y curve for seismic design could greatly underestimate the soil resistance at non-linear domain and cause overly conservative design.

Mechanical Performance Evaluation of RC Beams with FRP Hybrid Bars under Cyclic Loads (FRP 하이브리드 보강근을 가지는 RC보의 반복하중에 대한 역학적 성능 평가)

  • Hwang, Chul-Sung;Park, Jae-Sung;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.9-14
    • /
    • 2017
  • In the present work, a mechanical performances under cyclic loading in RC (Reinforced Concrete) beams with normal steel and FRPH (Fiber Reinforced Plastic Hybrid) bar are investigated. For the work, RC beam members with $200{\times}200{\times}2175mm$ of geometry and 24 Mpa of design strength are prepared, and 4-point-bending tests are performed for evaluation of cracking, yielding, and ultimate loads. Through static loading test, 48.9kN and 36.0 kN of yielding loads are measured for normal RC and FRPH beam, respectively. They have almost same ultimate load of 50.0 kN. Typical tension hardening behavior is observed in FRPH beam, which is caused by the behavior of FRPH bar with tension hardening. In cyclic loading conditions, FRPH beam has more smaller crack width and scattered crack pattern, and it shows more elastic recovery than normal RC beam. The energy dissipation ratio in FRPH beam is 0.83, which is greater than 0.62 in normal RC beam and it shows more effective resistance to cyclic loadings.

Evaluation of Fatigue Strength in Scallop at Field Bolted Joints of Longitudinal Rib and Deck Plate in Orthotropic Steel Decks (강바닥판 데크플레이트와 종리브 현장연결 스캘럽부의 피로강도 평가)

  • Choi, Dong Ho;Choi, Hang Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.683-690
    • /
    • 2002
  • Static and fatigue tests were performed to evaluate fatigue strength in scallop at field bolted joints of longitudinal rib and deck plate in orthotropic steel decks. Numerical parametric studies using finite elemtn analysis were also conducted to show the influence of parameters such as length and radius of scallop, and thickness of deckplate on the stress concentration at the scallop. In the low stress level, fatigue tests yielded cracks at the scallop while in the high stress level, catastrophic failure of longitudinal rib occurred following the failure of handhole cover plate. Fatigue strength was compared with JSSC specification and the predicted S-N curves using Shigley and Juvinall methods, and a satisfactory result was obtatined.

Cumulative Damage Characteristics of Concrete Subjected to Variable Amplitude Loadings (반복하중을 받는 콘크리트의 누가손상 특성)

  • Byun, Keun Joo;Kim, Moon Kyum;Han, Sang Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.43-54
    • /
    • 1987
  • Cumulative damage characteristics of concrete, on which rapetitive loads are applied, are investigated. Preliminarily, a series of uniaxial compression tests on cylindrical specimens of plain concrete is carried out to find out that, among various factors, stress levels of repetitive loadings and loading order are the most governing factors of cumulative damage of concrete. Based on this preliminary study, fatigue tests are carried out applying two levels of stresses, stepwisely. As a result, it is found that characteristics of cumulative damage of concrete are governed by nonlinear relationships and do not follow Miner's linear theory. It is also observed that cumulative damage characteristics and static strengths of concrete vary with loading history of stresses. Empirical equations which may be useful in predicting fatigue characteristics and remaining life of concrete stuctures are proposed for concrete subjected two stress levels.

  • PDF