• Title/Summary/Keyword: 정위

Search Result 578, Processing Time 0.019 seconds

On the Physical and Perceptual Precision of the Multi-point Control Method in HRTF Simulation (다점제어를 이용한 머리전달함수의 모의에 있어서의 물리적 모의정도와 청감상의 모의정도)

  • 김해영
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.323-332
    • /
    • 2004
  • Sound localization can be controlled by simulating the transfer functions from sound source to listener's ears. Even by using this method. a good performance cannot be expected when a listener slightly moves from the position where the transfer functions were measured. We have already been proposed the multi-point control method to overcome the problem of the listener's small movement. In this method, the transfer functions are simulated at multiple points around the listner's ears so that the points forms an area which covers the small movement of the listener. In this paper. we investigated the effect of applying multi-point control method for the control of sound localization. Results show that multi-point control is effective to keep the perceptual error of the localized direction small when the listener moves up to 6 cm from the original position.

On the Physical and Perceptual Precision of the Multi-point Control Method in HRTF Simulation (다점제어를 이용한 머리전달함수의 모의에 있어서의 물리적 모의정도와 청감상의 모의정도)

  • 김해영
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.324-324
    • /
    • 2004
  • Sound localization can be controlled by simulating the transfer functions from sound source to listener's ears. Even by using this method. a good performance cannot be expected when a listener slightly moves from the position where the transfer functions were measured. We have already been proposed the multi-point control method to overcome the problem of the listener's small movement. In this method, the transfer functions are simulated at multiple points around the listner's ears so that the points forms an area which covers the small movement of the listener. In this paper. we investigated the effect of applying multi-point control method for the control of sound localization. Results show that multi-point control is effective to keep the perceptual error of the localized direction small when the listener moves up to 6 cm from the original position.

The effects of a temporal masking on the sound laterlization (시간 마스킹이 음상정위에 미치는 영향)

  • Lee, Chai-Bong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.4
    • /
    • pp.352-356
    • /
    • 2010
  • In this study, it is discussed how the directional property of the sound lateralization is influenced by proceeding or succeeding tone. The acoustic source applied here is a reference sound which has 0.5 msec interaural time difference(ITD). Based on this reference sound, interfering sounds with five levels of magnitude are applied to the subjects with four kinds of inter-stimuli time intervals(ISI). The interfering sounds are also added as two different types, proceeding tone and succeeding tone. Additionally, in order to investigate a frequency influence, the reference sound and the interfering sounds are generated by using 2kHz, 4 kHz and a white noise. As a result, the influence on lateralization by proceeding tone is lager than that by succeeding tone. It can consider this result as the effect of temporal masking on lateralization. Moreover, there are small differences of masking effect on lateralization by combinations of pure tone. This result shows that the dependency of frequency domain between reference sound and interfering sound is small on the sound lateralization.

A study on the simplification of HRTF within low frequency region (저역 주파수 영역에서 HRTF의 간략화에 관한 연구)

  • Lee, Chai-Bong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.581-587
    • /
    • 2010
  • In this study, we investigated the effect of the simplification for low frequency region in Head-Related Transfer Function(HRTF) on the sound localization. For this purpose, HRTF was measured and analyzed. The result in the standard deviation of HRTF showed that the directional dependence of low frequency was smaller than that of high frequency region, which means the possibility of simplification in the low frequency region. Simplification was performed by flattening of the low frequency amplitude characteristics with the insertion of the high-pass filter, whose cutoff frequency is given by boundary frequency. Auditory experiments were performed to evaluate the simplified HRTF. The result showed that direction perception was not influenced by the simplification of the frequency characteristics of HRTF for the error of sound localization. The rate of confusion for the front and back was not affected by the simplification of the frequency characteristics within 1kHz of HRTF. Finally, we made it clear that the sound localization was not affected by the simplification of frequency characteristics of HRTF within 1kHz. The result is expected to be utilized to reduce the size of speech information with no deterioration of the directional characteristics of the speech signal.

Usefulness of Radiation Treatment Planning Applied Respiration Factor for Stereotactic Body Radiation Therapy in the Lung Cancer (폐암 환자의 정위체부방사선치료 시 호흡인자를 적용한 방사선 치료계획의 유용성)

  • Shin, Sung Pil;Kim, Tae-Hyung;So, Woon Young;Back, Geum Mun
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.587-593
    • /
    • 2016
  • We are evaluated the usefulness of radiation treatment planning applied respiration factor for stereotactic body radiation therapy in the lung cancer. Four dimensional computed tomography images were obtained in 10 patients with lung cancer. The radiation treatment plans were established total lung volume according to respiration images (new method) and conventional method. We was analyzed in the lung volume, radiation absorbed dose of lung and main organs (ribs, tracheobronchus, esophagus, spinal cord) around the tumor, respectively. We were confirmed that lung volume and radiation absorbed dose of lung and main organs around the tumor deference according to applied respiration. In conclusion, radiation treatment planning applied respiration factor seems to be useful for stereotactic body radiation therapy in the lung cancer.

Assessment of the Optic-guided Patient Positioning for Spinal Stereotactic Radiosurgery Using Novalis ExacTrac System (노발리스 ExacTrac system을 이용한 척추 정위 방사선수술 방법 평가)

  • 이동준;손문준;최광영;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.218-223
    • /
    • 2002
  • Stereotactic radiosurgery for intracranial lesion is well established since the Lars Leksell first introduced radiosurgery concept in 1951 Its use in the treatment of spinal lesion has been limited by the availability of effective immobilization devices. The first clinical experience of the spinal stereotactic radiosurgery technique was reported by Hamilton AJ. in 1995. Recently, Optic-guided patient positioning technique for extracranial stereotactic radiosurgery was developed and reported. This study is for assess the target positioning accuracy of the optic guided patient positioning system Exactrac (BrainLab., Inc, Germany). We have designed phantom for assess the accuracy of spinal stereotactic radiosurgery The infrared reflective body markers attached to the relatively immobile part of the body and a series of 2 mm CT images was taken. The image sets were transferred to the planning computer. During the radiosurgery treatment, we measure the real-time display showing the positioning values from Exactrac computer. And we compare the isocenter deviation from irradiated center point of the film which was mounted on the lesion site of the phantom and pin hole site of that film. The accuracy of the ExacTrac system in positioning a target point shows enough for the clinical applications.

  • PDF

Isocenter Reproducibility with Mask Fixation System in Stereotactic Radiosurgery (정위 마스크 시스템을 사용한 방사선수술시 회전중심점의 재현성)

  • 이동준;손문준;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.135-138
    • /
    • 2002
  • Fractionated stereotactic radiosurguy (FSRS) requires precise and reproducible patient set up. For these reasons non-invasive mask fixation methods have been used in Linac based FSRS. In this study, we measured and assessed the isocenter reproducibility using a commercial head mask fixation system based on thermoplastic materials. For the verification and the measurement of isocenter deviation a special acrylic brain phantom was designed. The designed phantom has 22 vertical rods and each rod has different lengths. At the end of the 8 rods, the monochromic film is attached and irradiated due to planned target position. Deviations of isocenter were measured separately for each direction. The mean deviation showed 0.4 mm in longitudinal direction, 0.1 mm in the lateral direction, 0.1 mm in the anterior-posterior direction of the treatment couch. The data demonstrates the high accuracy and reproducibility. This study reinforces previous literature published.

  • PDF

A study on the simplification of HRTF within high frequency region (고역 주파수 영역에서 HRTF의 간략화에 관한 연구)

  • Lee, Chai-Bong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • In this study, we investigated the effect of the simplification for high frequency region in Head-Related Transfer Function(HRTF) on the sound localization. For this purpose, HRTF was measured and analyzed. The result in the HRTF frequency characteristic of the back sound source showed that the decrease revel of high frequency was smaller than that of low frequency region, which means the possibility of simplification in the high frequency region. Simplification was performed by flattening of the high frequency amplitude characteristics with the insertion of the low-pass filter, whose cutoff frequency is given by boundary frequency. Auditory experiments were performed to evaluate the simplified HRTF. The result showed that direction perception was not influenced by the simplification of the frequency characteristics of HRTF for the error of sound localization. The rate of confusion for the front and back was not affected by the simplification of the frequency characteristics over 8kHz of HRTF. Finally, we made it clear that the sound localization was not affected by the simplification of frequency characteristics of HRTF over 8kHz.

Analysis of Induced Heterophoria Variations by Repeated Binocular Vision Examinations (반복된 양안시 검사로 유발된 사위도 변화 분석)

  • Leem, Hyun-Sung;Lee, Eun-Hee;Song, Yun-Young;Jung, Mi-A
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.281-286
    • /
    • 2018
  • The purpose of this study was to evaluate the degree of heterophoria variations according to visual fatigue induced by increasing number of examinations while repeating binocular vision examinations. Twenty - one adults in their twenties who had no heterotropia other eye disease or systemic disease underwent binocular vision examinations. As the examinations progressed, the degree of heterophoria increased in both orthophoria and heterophoria. When the distance examinations was repeated 5 times, orthophoria increased degree of $1.56{\Delta}$ heterophoria. and heterophoria increased degree of $1.63{\Delta}$ heterophoria. When the near examinations was repeated 5 times, orthophoria increased degree of $1.78{\Delta}$ heterophoria. and heterophoria increased degree of $2{\Delta}$ heterophoria.. As the number of examinations increased, the result gradually deviated from the normal range as visual fatigue increased. The degree of the variation is judged to be enough to make the wrong prescription in the clinic. In conclusion, it was found that the binocular vision examinations should be conducted more accurately and promptly.

Excellent Local Tumor Response after Fractionated Stereotactic Radiation Therapy for Locally Recurrent Nasopharynx Cancer (국소 재발 비인강암에 대한 정위적 방사선 분할 치료의 적용)

  • Lim Do Hoon;Chio Dong Rak;Kim Moon Kyung;Kim Dae Yong;Huh Seung Jae;Baek Chung-Hwan;Chu Kwang Chol;Yoon Sung Soo;Park Keunchil;Ahn Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.19-26
    • /
    • 1997
  • Purpose : This study is to report experience with Fractionated Stereotactic Radiation Therapy (FSRT) for locally recurrent nasopharynx cancer after curative conventional radiation therapy. Materials and Methods : Three Patients with locally recurrent and symptomatic nasopharynx cancer were given FSRT as reirradiation method between the Period of September of 1995 and August of 1996 For two Patients, application of FSRT is their third radiation therapy directed to the nasopharynx. Two patients were given low dose chemotherapy as radiation sensitizer concurrently with FSRT Authors used 3-dimensional coordinate system by individually made, relocatable Gill-Thomas-Cosman (GTC) stereotactic frame and multiple non-coplanar arc therapy dose Planning was done using Xknife-3. Total of 45 Gy/18 fractions or 50 Gy/20 fractions were given. Results : Authors observed satisfactory symptomatic improvement and remarkable objective tumor size decrease by follow-up MR images taken 1 month Post-FSRT in ali three patients, while no neurologic side effect attributable to reirradiation was noticed. Two died at 7 and 9 months with loco-regional and distant seeding outside FSRT field, while one patient is living for 4 month. Conclusion Authors experienced satisfactory therapeutic effectiveness and safety of FSRT as reirradiatlon method for locally recurrent nasopharynx cancer Development of more effective systemic chemotherapeutic regimen is desired for distant metastasis

  • PDF