• Title/Summary/Keyword: 정수비

Search Result 1,452, Processing Time 0.022 seconds

Mechanical Properties of Fiber-reinforced Cement Composites according to a Multi-walled Carbon Nanotube Dispersion Method (다중벽 탄소나노튜브의 분산방법에 따른 섬유보강 시멘트복합체의 역학적 특성)

  • Kim, Moon-Kyu;Kim, Gyu-Yong;Pyeon, Su-Jeong;Choi, Byung-Cheol;Lee, Yae-Chan;Nam, Jeong-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.2
    • /
    • pp.203-213
    • /
    • 2024
  • This study delves into the mechanical properties of fiber-reinforced cement composites(FRCC) concerning the dispersion method of multi-walled carbon nanotubes(MWCNTs). MWCNTs find utility in industrial applications, particularly in magnetic sensing and crack detection, owing to their diverse properties including heat resistance and chemical stability. However, current research endeavors are increasingly directed towards leveraging the electrical properties of MWCNTs for self-sensing and smart sensor development. Notably, achieving uniform dispersion of MWCNTs poses a challenge due to variations in researchers' skills and equipment, with excessive dispersion potentially leading to deterioration in mechanical performance. To address these challenges, this study employs ultrasonic dispersion for a defined duration along with PCE surfactant, known for its efficacy in dispersion. Test specimens of FRCC are prepared and subjected to strength, drawing, and direct tensile tests to evaluate their mechanical properties. Additionally, the influence of MWCNT dispersion efficiency on the enhancement of FRCC mechanical performance is scrutinized across different dispersion methods.

Characteristics of source localization with horizontal line array using frequency-difference autoproduct in the East Sea environment (동해 환경에서 차주파수 곱 및 수평선배열을 이용한 음원 위치추정 특성)

  • Joung-Soo Park;Jungyong Park;Su-Uk Son;Ho Seuk Bae;Keun-Wha Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.29-38
    • /
    • 2024
  • The Matched Field Processing (MFP) is an estimation method for a source range and depth based on the prediction of sound propagation. However, as the frequency increases, the prediction inaccuracy of sound propagation increases, making it difficult to estimate the source position. Recently proposed, the Frequency-Difference Matched Field Processing (FD-MFP) is known to be robust even if there is a mismatch by applying a frequency-difference autoproduct extracted from the auto-correlation of a high frequency signal. In this paper, in order to evaluate the performance of the FD-MFP using a horizontal line array, simulations were conducted in the environment of the East Sea of Korea. In the area of Bottom Bounce (BB) and Convergence Zone (CZ) where detection of a sound source is possible at a long range, and the results of localization were analyzed. According to the the FD-MFP simulations of horizontal line array, the accuracy of localization is similar or degraded compared to the conventional MFP due to diffracted field and mismatch of sound speed. There was no clear result from the simulations conforming that the FD-MFP was more robust to mismatch than the conventional MFP.

Utilizing deep learning algorithm and high-resolution precipitation product to predict water level variability (고해상도 강우자료와 딥러닝 알고리즘을 활용한 수위 변동성 예측)

  • Han, Heechan;Kang, Narae;Yoon, Jungsoo;Hwang, Seokhwan
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.7
    • /
    • pp.471-479
    • /
    • 2024
  • Flood damage is becoming more serious due to the heavy rainfall caused by climate change. Physically based hydrological models have been utilized to predict stream water level variability and provide flood forecasting. Recently, hydrological simulations using machine learning and deep learning algorithms based on nonlinear relationships between hydrological data have been getting attention. In this study, the Long Short-Term Memory (LSTM) algorithm is used to predict the water level of the Seomjin River watershed. In addition, Climate Prediction Center morphing method (CMORPH)-based gridded precipitation data is applied as input data for the algorithm to overcome for the limitations of ground data. The water level prediction results of the LSTM algorithm coupling with the CMORPH data showed that the mean CC was 0.98, RMSE was 0.07 m, and NSE was 0.97. It is expected that deep learning and remote data can be used together to overcome for the shortcomings of ground observation data and to obtain reliable prediction results.

The Usefulness of Mammography and Scintimammography in Differential Diagnosis of Breast Tumor (유방 종괴에서 악성 감별을 위한 유방촬영술과 유방스캔의 유용성 연구)

  • Kang, Bong-Joo;Chung, Young-An;Jung, Hyun-Seok;Jung, Jung-Im;Yoo, Ie-Ryung;Kim, Sung-Hoon;Sohn, Hyung-Sun;Chung, Soo-Kyo;Hahn, Seong-Tai;Lee, Jae-Mun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.492-497
    • /
    • 2004
  • Purpose: it is very important to differentiate breast cancer from benign mass. There are many reports to evaluate the differential diagnosis under the several diagnostic tools. We evaluated the usefulness of mammography and Tc-99m MIBI scintimammography in the differential diagnosis of breast mass and correlated with pathologic findings. Materials and Methods: This study included 80 patients (a8e: 24-72, mean: 48.4) who underwent mammography and Tc-99m MIBI scintimammography for breast masses. Scintimammographies (anterior-posterior and lateral projections) were acquired in 10 minutes and 2 hours after intravenous injection of Tc-99m MIBI. four specialists in diagnostic radioloay and nuclear medicine evaluated the findings of breast masses under the mammography and Tc-99m MIBI scintimammography, and calculated the tumor to background (T/B) ratio. The pathologic results were obtained and we statistically analyzed the correlations between pathologic results and imaging findings under the mammography and Tc-99m MIBI scintimammography by chi-square and correlation test. Results: The sensitivity, specificity, positive predictive value, and negative predictive value of mammography for detection of breast cancer were 87.5%, 56.3%, 75.0%), and 75.0% respectively. 45 cases of 80 patients were suspicious for breast cancer under the Tc-99m MIBI scintimammography. 41 cases of 45 patients were confirmed as breast cancer and the remaining 4 cases were confirmed as benign masses. The sensitivity, specificity, positive predictive value and negative predictive value of Tc-99m MIBI scintimammography for detection of breast cancer were 85.4%, 87.5%, 91.1%, and 80.8% respectively. The sensitivity of scintimammography was lower than that of mammography for detection of breast cancer, however the specificity, positive predictive value, and negative predictive value were higher. In the benign mass, the mean T/B ratio in 10 minutes was $1.409{\pm}0.30$, and that in 2 hours was $1.267{\pm}0.42$. The maximal T/B ratio of benign mass in 10 minutes was $1.604{\pm}0.42$, and that in 2 hours was $1.476{\pm}0.50$. In the malignant mass, the mean T/B ratio in 10 minutes was $2.220{\pm}1.07$, and that in 2 hours was $1.842{\pm}0.75$. The maximal T/B ratio of malignant mass was $2.993{\pm}1.94$, and that in 2 hours was $2.480{\pm}1.34$. And the T/B ratio under the early and delayed images were meaningful. Conclusion: The scintimammography is useful diagnostic tool to differentiate breast cancer from benign mass, although the sensitivity of mammography for detection of breast mass is high. Especially, the use of the T/B ratio is helpful to diagnose breast cancer.

Radioprotective Effects of Granulocyte-Colony Stimulating Factor in the Jejunal Mucosa of Mouse (생쥐에서 과립구 집락형성인자(Granulocyte-Colony Stimulating Factor)의 공장점막에 대한 방사선 보호효과)

  • Ryu, Mi-Ryeong;Chung, Su-Mi;Kay, Chul-Seung;Kim, Yeon-Shil;Yoon, Sei-Chul
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • Purpose : Granulocyle-colony stimulating factor (G-CSF) has been widely used to treat neutropenia caused by chemotherapy or radiotherapy. The efficacy of recombinant human hematopoietic growth factors in improving oral mucositis after chemotherapy or radiotherapy has been recently demonstrated in some clinical studies. This study was designed to determine whether G-CSF can modify the radiation injury of the intestinal mucosa in mice. Materials and Methods : One hundred and five BALB/c mice weighing 20 grams were divided into nine subgroups including G-CSF alone group $(I:10\;{\mu}g/kg\;or\;II:100\;{\mu}g/kg)$, radiation alone group (7.5 or 12 Gy on the whole body), combination group with G-CSF and radiation (G-CSF I or II plus 7.5 Gy, G-CSF I or II plus 12 Gy), and control group. Radiation was administered with a 6 MV linear accelerator (Mevatron Siemens) with a dose rate of 3 Gy/min on day 0. G-CSF was injected subcutaneously for 3 days, once a day, from day -2 to day 0. Each group was sacrificed on the day 1, day 3, and day 7. The mucosal changes of jejunum were evaluated microscopically by crypt count per circumference, villi length, and histologic damage grading. Results : In both G-CSF I and II groups, crypt counts, villi length, and histologic damage scores were not significantly different from those of the control one (p>0.05). The 7.5 Gy and 12 Gy radiation alone groups showed significantly lower crypt counts and higher histologic damage scores compared with those of control one (p<0.05). The groups exposed to 7.5 Gy radiation plus G-CSF I or II showed significantly higher crypt counts and lower histologic damage scores on the day 3, and lower histologic damage scores on the day 7 compared with those of the 7.5 Gy radiation alone one (p<0.05). The 12 Gy radiation plus G-CSF I or II group did not show significant difference in crypt counts and histologic damage scores compared with those of the 12 Gy radiation alone one (p>0,05). Most of the mice in 12 Gy radiation with or without G-CSF group showed intestinal death within 5 days. Conclusion : These results suggest that G-CSF may protect the jejunal mucosa from the acute radiation damage following within the tolerable ranges of whole body irradiation in mice.

  • PDF

Clinical course and prognosis of hemodynamically significant congenital heart defects in very low birth weight infants (혈역학적으로 의미있는 선천성 심기형을 가진 극소 저체중 출생아의 임상경과 및 예후)

  • Yoo, Hye Soo;Kim, Ji Eun;Park, Soo Kyoung;Seo, Hyun Ju;Jeong, Yoo Jin;Chio, Seo Heui;Jeong, Soo In;Kim, Sung Hoon;Yang, Ji Hyuk;Huh, June;Chang, Yun Sil;Jun, Tae Gook;Kang, I Seok;Park, Won Soon;Park, Pyo Won;Lee, Heung Jae
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.481-487
    • /
    • 2009
  • Purpose : This study investigated the clinical course and prognostic factor of very low birth weight infants (VLBWI) with hemodynamically significant congenital heart defects (CHDs). Methods : Medical records of 1,098 VLBWI with birth weight <1,500 g who had been admitted to the neonatal intensive care unit of Samsung Medical Center from October 1994 to December 2007 were reviewed retrospectively. The data for these patients with hemodynamically significant CHD (n=33) were compared with those without CHD (n=1,065). Results : The incidence of CHD was 3.0% (33 patients) 7 patients (21%) had CHD combined with the congenital abnormalities or chromosomal disorders. The most common CHD was a ventricular septal defect. The incidence of intrauterine growth retardation was higher in patients with CHD than in patients without CHD (34% vs. 20%), but there were no significant differences in gestational age, birth weight, respiratory distress syndrome, bronchopulmonary dysplasia, necrotizing enterocolitis, severe intraventricular hemorrhage (${\geq}$Gr III), and periventricular leukomalacia. Cardiac surgery was performed on 13 patients (39%). Nine patients received staged operations, and 10 patients received early intervention. The overall mortality in patients who had CHD was higher than in the patients who did not have CHD (27% vs. 16%). In patients with CHD, congenital abnormalities or chromosomal disorders were more important factors for increased mortality (86% vs. 11%) than the degree of complexity of CHD (19% vs. 42%). Conclusion : The most important prognostic factors of VLBWI with CHD are the associated congenital abnormalities or chromosomal disorders.

Changes of Radiation Dose and Image Quality Due to Additional Filtration Material in Computed Radiography (Computed Radiography에서 Additional Filtration Material에 따른 Radiation Dose와 Image Quality의 변화)

  • Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Filter absorbs low-energy X-ray to increase the average energy and reduces patient exposure dose. This study investigates if the materials of Mo and W could be used for the digital imaging device CR by conducting image assessment and dose measurement of SNR, FOM and histogram. In addition, measurement of beam quality was conducted depending on the material of the filter, and at the same time, a proper combination of filters was examined depending on the change in tube voltage (kVp). In regard to entrance skin dose, Mo filter showed the dose reduction by 42~56%, compared to Cu filter. Moreover, Mo filter showed higher transmission dose by around 1.5 times than that of Cu filter. In image assessment, it was found that W was unsuitable to be used as a filter, whereas Mo could be used as a filter to reduce dose without decline in image quality at the tube voltage of 80 kVp or higher. As tube voltage increased, 2.0 mm Al+0.1 mm Mo almost had a similar histogram width to that of 2.0 mm Al+0.2 mm Cu. Therefore, Mo filter can be used at relatively high tube voltage of 80 kVp, 100 kVp and 120 kVp. The SNR of 2.0 mm Al+0.1 mm Mo did not show any significant difference from those of 2.0 mm Al+0.2 mm Cu and 2.0 mm Al+0.1 mm Cu. As a result, if Mo filter is used to replace Cu filter in general radiography, where 80 kVp or higher is used for digital radiation image, patient exposure dose can be reduced significantly without decline in image quality, compared to Cu filter. Therefore, it is believed that Mo filter can be applied to chest X-ray and high tube voltage X-ray in actual clinical practice.

Responsiveness of Muscarinic and Alpha Adrenergic Activation on Endothelial Cell in Isolated Canine Renal Arteries (개 신동맥 내피세포의 무스카린성 및 알파 아드레날린성 수용체에 대한 작용)

  • Chung, Soo-Youn;Chang, Ki-Churl;Lim, Jung-Kyoo
    • The Korean Journal of Pharmacology
    • /
    • v.25 no.1
    • /
    • pp.43-51
    • /
    • 1989
  • Responsiveness of muscarinic and alpha adrenoceptor activation on endothelial cells was studied in isolated canine renal artery rings. Ach (10-100 nM), dose dependently, relaxes endothelial intact rings precontracted with phenylephrine ($IC_{50}$ of Ach was 34.5 nM). Selective mechanical destruction of the endothelium transformed the activity of this substance from vasodilatation to vasoconstriction. Acetylcholine induced relaxations could be selectively inhibited competitively by atropine, but could not be inhibited by cyclooxygenase inhibitor. Methylene blue, however, an inhibitor of soluble guanylate cyclase activity, inhibited Ach as well as sodium nitroprusside (SNP) induced relaxation. Relaxation produced by prostacyclin was not modified by methylene blue. On the other hand, alpha adrenoceptor agonist did not relax but contract canine renal artery rings possessing an intact intima precontracted with U-46619. Clonidine, however, selective alpha-2 adrenergic agonist, is more susceptible than phenylepherine, selective alpha-1 adrenergic agonist, to the inhibitory effect of contraction. These results suggest that in canine renal artery rings, 1) muscarinic receptor is responsible for releasing endothelium dependent relaxation factor (EDRF). 2) alpha-1 and alpha-2 adrenergic receptors are present in canine renal artery. 3) relaxation via EDRF is antagonized by methylene blue, providing further evidence that EDRF acts through a cGMP mechanism.

  • PDF

Biomass and Nutrient Stocks of Tree Components by Stand Density in a Quercus glauca Plantation (종가시나무 조림지의 임분밀도에 따른 임목 바이오매스 및 양분축적량)

  • Choi, Bong-Jun;Baek, Gyeongwon;Jo, Chang-Gyu;Park, Seong-Wan;Yoo, Byung Oh;Jeong, Su-Young;Lee, Kwang Soo;Kim, Choonsig
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.3
    • /
    • pp.294-302
    • /
    • 2016
  • This study was conducted to evaluate aboveground tree biomass and nutrient (C, N, P, K, Ca, and Mg) response of tree components by high (1,933 trees $ha^{-1}$) and low (1,200 tree $ha^{-1}$) stand densities in a 27-year-old Quercus glauca plantation. The study site was located in Goseong county, Gyeongsangnam-do, southern Korea. Total 12 trees (6 high and 6 low stand densities) were cut to develop allometric equations and to measure nutrient concentration of tree components. Stand density-specific allometric equations in the high and low stand densities were significant (P < 0.05) in tree components with diameter at breast height (DBH). Also, generalized allometric equations could be applied to estimate tree biomass regardless of the difference of stand density because of no significant effect on slope of stand density-specific allometric equations. Aboveground tree biomass estimated by the allometric equations was significantly higher in the high stand density (177 Mg $ha^{-1}$) than in the low stand density (114 Mg $ha^{-1}$). However, nutrient concentration of tree components was not significantly affected by the difference of stand density. Nutrient stocks in tree components were not significantly between the high stand density and the low stand density, except for the N and P stocks of stem wood. These results indicate that aboveground tree biomass could be significantly affected by stand density, but nutrient concentration among the tree components was not affected by the difference of stand density in a Quercus glauca plantation.

Fertilization Effects on Allometric Equations and Biomass in a Moso Bamboo (Phllostachys pubescens) Stand (맹종죽 임분에 시비가 상대생장식 및 바이오매스에 미치는 영향)

  • Jo, Chang-Gyu;Baek, Gyeongwon;Park, Seong-Wan;Yoo, Byung Oh;Jung, Su Young;Lee, Kwang Soo;Kim, Choonsig
    • Journal of Korean Society of Forest Science
    • /
    • v.106 no.4
    • /
    • pp.380-387
    • /
    • 2017
  • This study was carried out to determine fertilization effects on allometric equations and biomass production in a Moso bamboo (Phllostachys pubescens) stand of the Gajwa National Experimental Forests, Jinju, Korea. The study site was fertilized for approximately 30 years to produce edible bamboo shoots. Total 20 bamboos (10 fertilized and 10 unfertilized) were cut to develop allometric equations and to estimate biomass accumulation of each bamboo component. Allometric equations of each bamboo component in the fertilized and unfertilized plots were significant (P < 0.05) with diameter at 20 cm from ground ($D_{20}$), diameter at breast height (DBH), culm height (H), and $DBH^2{\cdot}H$. Aboveground biomass estimated by the allometric equations (DBH) was significantly higher in the unfertilized plots ($106.38Mg\;ha^{-1}$) in culm density of $6,833culm\;ha^{-1}$ than in the fertilized ($57.68Mg\;ha^{-1}$) plots in culm density of $4,633culm\;ha^{-1}$. The proportion of each biomass component was culm (79%), followed by branches (14%) and leaf (7%) in the fertilized plots, whereas it was culm (81%), followed by branches (13%), and leaf (6%) in the unfertilized plots. The results indicate that aboveground biomass accumulation in a Phllostachys pubescens stand was little affected by fertilizer application because of the difference of culm density.