• Title/Summary/Keyword: 정상 유동

Search Result 1,131, Processing Time 0.031 seconds

A study on establishing the aerodynamic database though the external flow method of a rotating vehicle (회전 운동하는 비행체의 외부 유동장 해석을 통한 공력데이터베이스 구축 연구)

  • Kang, Tae-Woo;Ahn, Jong-Moo;Lee, Hee-Rang;Choi, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.41-47
    • /
    • 2017
  • With the introduction of new technologies, ground weapons have led to the development of artificial intelligence and the attention of major developed countries. In this study, CFD was performed through the BLU-103 model to obtain aerodynamic data for aircraft that are subjected to rotational motion. To simulate the steady-state of a rotating body, the body was fixed and the principle of rotating the body by rotating the surrounding air was used. In order to examine the aerodynamic feasibility of the rotating aircraft, the analysis was carried out at intervals of $30^{\circ}$ angle from $0^{\circ}$ to $90^{\circ}$ for the simple shape and the side slip angle. It was confirmed that the drag coefficient for the simple model satisfies the quantitative results of 1.0 ~ 1.2 through CD presented in "Drag Book". The aerodynamic data was constructed by applying the valid input verified through the simple type analysis conditions to the actual shape, and the tendency was analyzed. The analysis confirmed that CX, CZ and CY increase not only in the simple model but also in the rotation of the actual model. Especially, the influence of CZ was judged to have contributed to the flight.

A Case of Disseminated Mycobacterium intracellulare Infection in an Immunocompromised Host (면역 저하 환자에서 발생한 파종성 Mycobacterium intracellulare 감염 1예)

  • Kim, Sun Young;Oh, Dong Wook;Yu, Ji Hee;Kim, Donghoi;Noh, Sehui;Roh, JaeHyung;Jung, Sang-Su;Yoo, Dong-Jun;Shim, Tae Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.32-36
    • /
    • 2009
  • We report a case of disseminated Mycobacterium intracellulare infection in a 31-year-old man who had been diagnosed as having dermatomyositis and systemic lupus erythematosus 3-years prior. The patient developed a left pleural effusion M. intracellulare was repeatedly isolated from the pleural fluid. After antimycobacterial treatment, the patient's pleural effusion resolved, but a left knee joint effusion developed newly and M. intracellulare was cultured from the joint fluid. At present, the patient has been taking antimycobacterial medication for 15 months but his left knee joint fluid remains positive for M. intracellulare. To our knowledge, this is the second reported case of disseminated NTM infection in a non-HIV infected patient in Korea.

Numerical Simulations of Nonlinear Behaviors of Pulsating Instabilities in Counterflow Diffusion Flames (대향류 확산화염에서 맥동 불안정성의 비선형 거동에 대한 수치해석)

  • Lee, Su-Ryong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.9
    • /
    • pp.859-866
    • /
    • 2010
  • Nonlinear dynamics of pulsating instability-diffusional-thermal instability with Lewis numbers sufficiently higher than unity-in counterflow diffusion flames, is numerically investigated by imposing a Damkohler number perturbation. The flame evolution exhibits three types of nonlinear behaviors, namely, decaying pulsating behavior, diverging behavior (which leads to extinction), and stable limit-cycle behavior. The stable limit-cycle behavior is observed in counterflow diffusion flames, but not in diffusion flames with a stagnant mixing layer. The critical value of the perturbed Damkohler number, which indicates the region where the three different flame behaviors can be observed, is obtained. A stable simple limit cycle, in which two supercritical Hopf bifurcations exist, is found in a narrow range of Damkohler numbers. As the flame temperature is increased, the stable simple limit cycle disappears and an unstable limit cycle corresponding to subcritical Hopf bifurcation appears. The period-doubling bifurcation is found to occur in a certain range of Damkohler numbers and temperatures, which leads to extend the lower boundary of supercritical Hopf bifurcation.

Application for Fire Protection Regulation based on Risk-Informed and Performance-Based Analysis (위험도 및 성능기반 분석방법에 의한 원전 화재방호규정 적용 방안)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.65-70
    • /
    • 2006
  • From the beginning of the construction stage, the fire protection regulation for the nuclear power plants conforms to the design requirements for the acquisition of the license permit. This regulation is based on the plant status of the normal operation, but it is not enough to be used as an application standard for fire protection at the transient mode of the plant and the outage time for refueling as well as for the plant decommissioning. While the advanced fire protection requirement that has been developed in America recently suggests the performance-based requirement and management rule applicable to the overall life time of the plant, it simply represents the conceptual application. It means that it can not be treated as appropriate standards because it does not deal with the qualitative and quantitative approach in specific ways. By the way, with the use of the performance-based fire risk analysis, the dynamic behavior of the heat and smoke at the fire compartment of the nuclear power plants can be analyzed and the thermal effect to the safety-related equipment and cables can be evaluated as well. At this paper, it suggests the ways to change the applicable fire protection regulations and the required evaluation items for the fire risk resulted from the plant configuration change with an intent to introduce the state-of-the-art quantitative fire risk analysis technology at the domestic nuclear power plants.

Provenance of Recent Clay Minerals of the Chinju Bay, Southern Coast of Korea (진주만 현생퇴적물중 점토광물의 기원에 관한 연구)

  • KIM Dae-Choul;KIM Hee-Joon;SONG Yong-Sun;PAIK In-Sung;PARK Maeng-Eon;CHUNG Sang-Yong;SONG Shi-Tae;HWANG Jin-Yeon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.4
    • /
    • pp.246-258
    • /
    • 1988
  • Semi-quantitative analysis of $less-than-2{\mu}m$ clay minerals in thirty-nine superficial sediments from the Chinju Bay, southern coast of Korea, was made to reveal the distribution, provenance and dispersal pattern of fine-grained sediments. Additional nine samples were also taken from the Choryang Cheon (a river draining the kaolin-rich Hadong area) to investigate the influence of river a discharge. Grain size analysis for the Chinju Bay sediment samples was performed simultaneously as an aid to understand the sediment types and depositional environments. Except for the northeastern part, clayey mud predominates the entire bay. Average relative abundance of the four major clay minerals, I. I., illite, kaolinite, chlorite and smectite, is $55.1\%,\;23\%,\;21.5\%\;and\;0.4\%$, respectively. Although illite dominant clay mineral, the average content is about $10\~20\%$ tourer than that of the nearby continental shelf area. On the contrary, kaolinite content in the bay is about $10\%$ higher than that of the shelf area. Recent clay minerals of the Chinju Bay are mainly derived from the nearby inland area through numerous rivers and streams. Transport from shelf area, however. also seems to be important.

  • PDF

Experimental Study of SBLOCA Simulation of Safety-Injection Line Break with Single Train Passive Safety System of SMART-ITL (SMART-ITL 1 계열 피동안전계통을 이용한 안전주입배관 파단 소형냉각재상실사고 모의에 대한 실험적 연구)

  • Ryu, Sung Uk;Bae, Hwang;Ryu, Hyo Bong;Byun, Sun Joon;Kim, Woo Shik;Shin, Yong-Cheol;Yi, Sung-Jae;Park, Hyun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.165-172
    • /
    • 2016
  • An experimental study of the thermal-hydraulic characteristics of passive safety systems (PSSs) was conducted using a system-integrated modular advanced reactor-integral test loop (SMART-ITL). The present passive safety injection system for the SMART-ITL consists of one train with the core makeup tank (CMT), the safety injection tank, and the automatic depressurization system. The objective of this study is to investigate the injection effect of the PSS on the small-break loss-of-coolant accident (SBLOCA) scenario for a 0.4 inch line break in the safety-injection system (SIS). The steady-state condition was maintained for 746 seconds before the break. When the major parameters of the target value and test results were compared, most of the thermal-hydraulic parameters agreed closely with each other. The water level of the reactor pressure vessel (RPV) was maintained higher than that of the fuel assembly plate during the transient, for the present CMT and safety injection tank (SIT) flow rate conditions. It can be seen that the capability of an emergency core cooling system is sufficient during the transient with SMART passive SISs.

Effect of Nozzle Shape and Injection Pressure on Performance of Hybrid Nozzle (노즐 형상 및 분사 압력이 하이브리드 노즐 성능에 미치는 영향 연구)

  • Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.74-79
    • /
    • 2017
  • The fire extinguishing performance of hybrid nozzle systems is improved by injecting an extinguishing agent concentrically into the target site and, in this study, water mist is used as a water curtain to confine the droplets of the agent. In this study, we numerically investigated the effect of the foundation angle and injection pressure on the performance of a hybrid nozzle by evaluating the mean radius of the volume fractions of the agent and water mists. An experiment involving a water mist nozzle was carried out to validate the numerical method and then the droplet behaviors, e.g., stochastic collision, coalescence and breakup, were calculated with 2-way interaction Discrete Particle Modeling (DPM) in the steady state for the hybrid nozzle system. The mean radius of the water mists increased by about 40 %, whereas that of the agent decreased by about 21 %, when the injection pressure was increased from 30 bar to 60 bar. In addition, the mean radius of the agent increased by about 24 % as the foundation angle of the hybrid nozzle head increased from $30^{\circ}$ to $60^{\circ}$. As a result, it can be inferred that the injection angle and pressure are important factors for hybrid water mist designs.

Parametric Numerical Study on the Performance of Helical Tidal Stream Turbines (헬리컬 터빈의 설계인자에 따른 성능 연구)

  • Han, Jun-Sun;Choi, Da-Hye;Hyun, Beom-Soo;Kim, Moon-Chan;Rhee, Shin-Hyung;Song, Mu-Seok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.2
    • /
    • pp.114-120
    • /
    • 2011
  • The characteristics of a helical turbine to be used for tidal stream energy conversion have been numerically studied with varying a few design parameters. The helical turbines were proposed aiming at mitgating the well known poor cut-in characteristics and the structural vibration caused by the fluctuating torque, and the basic concept is introducing some twisting angle of the vertical blade along the rotation axis of the turbine. Among many potential controling parameters, we focused, in this paper, on the twisting angle and the height to diameter ratio of the turbine, and, based on the numerical experiment, We tried to propose a configuration of such turbine for which better performance can be expected. The three-dimensional unsteady RANS equations were solved by using the commercial CFD software, FLUENT with k-${\omega}$ SST turbulence model, and the grid was generated by GAMBIT. It is shown that there are a range of the twisting angle producing better efficiency with less vibration and the minimum height to diameter ratio above which the efficiency does not improve considerably.

The Effects of Warm and Cold Stimulations on the Temperature Distribution in the Prostate (냉.온열의 반복 자극이 전립선 내부의 온도 분포에 미치는 영향)

  • 문우석;백병준;박복춘;김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.467-475
    • /
    • 2002
  • Hyperthermia using transrectal thermal probes has been used for a noninvasive treatment of prostate diseases. However it is known that heating the rectal wall at excessively high temperature can lead to destruction of the rectal mucous membrane. and it is difficult to maintain an optimum temperature over the entire prostate. Thus, a more accurate understanding of the heat transfer mechanism between prostate and hyperthermia system is needed Numerical analysis was performed to investigate how the cold/warm stimulations on the prostate surface affect the temperature distribution in the prostate model. The general purpose software "FLUENT" was used for obtaining a finite volume solution to the unsteady conduction equation and to calculate the time-varying temperature in the prostate. Effects of the warm/cold stimulations and the stimulation frequency on the temperature distribution were simulated. and we visualized how hyperthermia affected the inside of the prostate. It was found that the effect of hyperthermia by using a typical heating method is limited due to the low thermal conductivity of the prostate. Consecutive repetitions of warm and cold stimulations were considered to provide the thermal irritations inside a prostate. The effects of temperature difference and duration of warm/cold stimulations were investigated, and basic data for the optimum period and effective patterns of stimulations were obtained. A simplified bioheat equation was also solved to describe effects of the blood flow on the blood-tissue heat transfer. The effect of blood flow was not dominant compared to that of warm/cold stimulations. These results might be used as data for design of prostate treating probe, prostatic therapy and thermal stimulation effects on the prostate.

Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites (맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구)

  • Nguyen, Vanduc;Kim, Dooyoung;Hur, Wonho;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.38-58
    • /
    • 2018
  • The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.