• Title/Summary/Keyword: 정밀 광학 정렬

Search Result 57, Processing Time 0.027 seconds

Fabrication of the Integrated Triplexer Using Micro Block Stacking Method (Micro-block Stacking 방법으로 제작한 집적형 Triplexer 제작 및 특성 측정)

  • Yoon, Hyun-Jae;Kim, Jin-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.5
    • /
    • pp.217-221
    • /
    • 2012
  • In this paper, we have fabricated by means of the "Micro-Block Stacking (MBS)" method the 8 pin mini DIL integrated Triplexer, which can transmit CATV and voice/data at the same time in a single fiber. Our MBS technique is a novel scheme of compact optical module packaging which secures precision positioning of the components on the optical beam path by prefixed stacks of ceramic blocks. The subassembly in which a laser diode, two receiver photodiodes, two WDM filters, and four micro lenses are integrated is only $5.40mm{\times}2.15mm{\times}1.05mm$ in size. As the Triplexer is aligned to the single mode fiber, the transmitter power of -14.5 dBm and the receiver sensitivities of 0.83 A/W, 0.73 A/W for 1550 nm, 1490 nm, respectively are obtained.

Systematic Error Correction in Dual-Rotating Quarter-Wave Plate Ellipsometry using Overestimated Optimization Method (최적화 기법을 이용한 두 개의 회전하는 사분파장판으로 구성된 타원편광분석기에서의 체계적인 오차 보정)

  • Kim, Dukhyeon;Cheong, Hai Du;Kim, Bongjin
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.1
    • /
    • pp.29-37
    • /
    • 2014
  • We have studied and demonstrated general, systematic error-correction methods for a dual rotating quarter-wave plate ellipsometer. To estimate and correct 5 systematic error sources (three offset angles and two unexpected retarder phase delays), we used 11 of the 25 Fourier components of the ellipsometry signal obtained in the absence of an optical sample. Using these 11 Fourier components, we can determine the errors from the 5 sources with nonlinear optimization methods. We found systematic errors ${\epsilon}_3$, ${\epsilon}_4$, ${\epsilon}_5$) are more sensitive to the inverted Mueller matrix than retarder phase delay errors (${\epsilon}_1$, ${\epsilon}_2$) because of their small condition numbers. To correct these systematic errors we have found that error of any variety must be less than 0.05 rad. Finally, we can use the magnitudes of these errors to correct the Mueller matrix of optical components. From our experimental ellipsometry signals, we can measure phase delay and the rotational angular position of its fast axis for a half-wave plate.

Fabrication and Packaging of Planar Waveguide Brags Grating (평판도파로 브래그격자 제조 및 접속)

  • 한준모;최준석;문형명;임기건;이형종;최두선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.141-144
    • /
    • 2002
  • Computer code was developed to design waveguide gratings based on coupled-mode equations and the transfer matrix formalism. The experimental set-up has been constructed for inscribing Bragg gratings in planar waveguides with a phase mask and uv laser beam, which enables alignment and packaging of grating devices as well as in-situ performance measurements. Bragg grating has been fabricated on silica planar waveguides with 0.75% Germanium concentration and its transmittance spectrum was measured to have 95% reflectance at the peak wavelength. Optical losses as the function of the misalignment were measured and their usage is described.

  • PDF

Development of TRT Kit for Optical Experiments with Reflective Telescopes (다양한 반사광학계 실험 실습을 위한 TRT Kit 개발)

  • Park, Woojin;Pak, Soojong;Chang, Seunghyuk;Kim, Geon Hee;Jeong, Byeongjoon;Kim, Sanghyuk;Lee, Hye-In;Ji, Tae-Geun;Gwak, Jeongha;Jo, Kwang;Kim, Hyoeun;Choi, Saepbyul;Park, Soonchang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.52.3-53
    • /
    • 2016
  • 일반적으로 사용되는 소구경 망원경은 경통에 의한 차폐로 인해 내부 구조를 보기 쉽지 않으므로, 망원경 광학계를 이해하기에는 적합하지 않다. 본 연구에서는 최소한의 배플 만을 사용하여 경통이 없는 구조의 개방형 망원경을 설계 및 제작하였다. 개발된 변환식 반사망원경 키트(TRT Kit, Transformable Reflecting Telescope Kit)는 부경 모듈을 교체하는 방식만으로 뉴턴식 망원경(Newtonian Telescope), 카세그레인식 망원경(Cassegrain Telescope), 그리고 그레고리식 망원경(Gregorian Telescope)으로 변형하는 것이 가능하다. 주경, 부경을 비롯한 망원경의 모든 부분은 사용자가 직접조립할 수 있도록 모듈화(Modularization) 하였다. 또한 부경에 부착된 슬라이딩 장치 및 리니어 스테이지(Linear Stage)는 망원경의 초점을 정밀하게 맞출 수 있도록 설계하였다. TRT Kit를 이용하여 학생들은 세 가지 형태의 망원경 광학계를 직접 조립하고 그 구조 및 성능을 비교해 볼 수 있으며, 광축 정렬, 정밀 초점 조절 과정을 통해 기본적인 광학계의 원리를 이해 할 수 있다.

  • PDF

Backward Testing Method of MTF measurement for optical engine of CRT of rear projection HDTV (후면투사식 CRT 고화질 텔레비전용 광학엔진의 변조전달함수 측정을 위한 후방검사 변조전달함수 측정법)

  • Song, Jong-Sup;Jo, Jae-Heung;Hong, Sung-Mok;Lee, Yun-Woo;Song, Jae-Bong;Lee, Hoe-Yun;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.56-62
    • /
    • 2005
  • Because of the wide plane and the curved field of CRT rear projection high definition television, its MTF(modulation transfer function) can't be easily measured by the usual forward testing method. Then we propose a backward testing method for the MTF so that the object plane and the image analyzer of forward testing are located at positions opposite each other. We prefer to use the backward testing method because the forward testing method has poor accuracy caused by very small numerical aperture, low spatial resolutions, and long depth of focus. We found that the backward testing method was very easy to align and had high repeatability. We confirmed the confidence of results obtained by the backward testing method in comparison with designed results.

Evaluation of a Aluminum Hyperbolic Mirror with the Diameter of 300 mm(f/1.98) by Using the Autostigmatic Null Lens System Assembled in a Fixed Tube Mount (경통고정식 자동무수차점 널 렌즈 테스트법을 이용한 직경 300 mm(f/1.98) 알루미늄 쌍곡면 거울의 형상측정)

  • Lee, Young-Hun;Jo, Jae-Heung;Rim, Cheon-Seog;Yang, Sun-Choel;Kim, Geon-Hee;Won, Jong-Ho;Jeong, Youn-Hong
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.412-419
    • /
    • 2006
  • We design and fabricate an autostigmatic null lens system assembled in a fixed tube mount in order to evaluate the shape of an aluminum hyperbolic mirror with the diameter of 300 mm and the f-number of 1.98, which is fabricated by a high precision aspherical DTM (diamond turning machine). Also, we evaluate the degree of shape of the aspherical mirror by this autostigmatic null lens testing method. The autostigmatic null lens system assembling in a fixed tube mount has several advantages of light weight, good mechanical stability, etc. The permissible fabricating limits of null lenses and a mount are determined by considering various tolerances to assure the measurement reliability.

Moir'e fringes generated by the superposition of elongated circular grating and Talbot image and their applications (Elongated Circular Grating의 Talbot 결상을 이용한 무아레 무늬 발생과 응용)

  • Lee, Sang-Il;Jo, jae-Heung;Chang, Soo;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.1
    • /
    • pp.25-31
    • /
    • 2001
  • The Talbot effect of an elongated circular (EC) grating composed of a line grating and two semicircular gratings with well matched pitches is experimentally presented. As the relative positions between the fixed EC grating and the moving Talbot image of another EC grating or a self Talbot image are one-dimensionally deformed, we can visually observe moire fringes generated by their superposition. Two examples of their applications, that is, the measurement of the wedged angle of a wedged prism and of the fine rotational angle of a mirror are described.cribed.

  • PDF

A Multi-Degree of Freedom Measurement System for Determining Geometric Errors in Miniaturized Machine Tool (소형공작기계의 기하학적 오차 평가를 위한 다자유도 측정시스템)

  • S. H., Kweon;Y., Liu;S. H., Yang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.638-643
    • /
    • 2004
  • 소형화된 기계가공시스템은 사용재료의 다양화와 에너지 및 공간의 감소와 같은 장점을 가지고 작고 정밀한 부품을 가공할 수 있는 시스템으로 주목받고 있다. 이러한 시스템이 비록 그 크기가 일반적인 가공시스템에 비해 작지만 정렬 및 조립공정, 기계요소의 불완정성에 의한 기하학적 오차는 여전히 존재한다. 기하학적 오차 평가는 기계시스템의 정밀도를 효과적으로 적은 비용으로 향상시킬 수 있는 오차보정기술을 적용할 수 있는 토대가 된다. 일반적으로, 3 축의 직선축으로 이루어진 공작기계는 21 개의 오차요소를 가진다. 레이져간섭계는 이러한 오차요소를 평가하는데 널리 사용되고 있지만 광학계를 정렬하고 설치하는 데 많은 어려움이 있으며 한번의 설치로 한 개의 오차요소만이 측정 가능하다. 또한, 소형공작기계의 경우, 그 크기로 인해 기존의 레이져 간섭계를 직접적으로 적용할 수 없다. 따라서, 본 연구에서는 소형공작기계를 포함한 소형가공시스템의 기하학적 오차 평가를 위한 새로운 다자유도 측정시스템을 제안하였다. 5 개의 정전용량변위센서를 사용하는 이 시스템을 통해 한 축의 움직임에 따른 5 개의 오차요소를 동시에 측정 가능하다. 균질 변환행렬을 이용한 측정알고리듬을 구성하고 이를 모의시험을 통해 평가하였다. 수학적 모델링을 통해 각 센서의 출력값을 유도하고 이를 이용하여 각 오차요소를 계산하기 위한 식을 유도하였다. 여기서, 단순화된 식을 적용한 경우, 임의의 오차에 대한 측정 알고리듬의 정확도를 평가하였다. 또한, 측정 시스템의 설치시 발생하는 셋업오차에 대한 측정 알고리듬의 민감도 분석을 행하였다. 제안하는 측정 시스템은 구조가 간단하고 고가의 부가장비가 필요치 않다. 또한, 적은 비용으로 구성할 수 있으며 높은 측정 정밀도를 가지고 소형가공시스템에 필요한 오차 평가를 행할 수 있다.가 함유된 계란을 생산하고 섭취하였을 때 특정항체들의 결합을 통해 병원성 미생물의 성장이나 군체를 형성하는 것을 무력화시켜 결과적으로 병원균을 감소시키거나 억제시킨다는 점이다. 오늘날 약물에 내성을 지닌 박테리아의 출현으로 질병감염을 막는데 항생제의 사용효과가 점차 감소하고 있기 때문에 이러한 항생제를 대체할 수 있는 방안으로 계란항체를 이용할 수 있다.한 중공 플랜지 형상의 단조 방법 중 보다 적절한 단조방법인 압조 단조에 있어서 일반적으로 사용되고 있는 SM10C에 대한 유한요소 해석을 수행하였으며, 제품의 형상비에 따라 폴딩 결함의 발생 유무를 검토하고, 폴딩 결함 없이 단조하기 위한 중공 플랜지의 형상한계 비를 제시하였다.도 경미하게 나타났으나, 경련이 나타난 쥐에서는 KA만을 투여한 흰쥐와 구별되지 않았다. 이상의 APT의 항산화 효과는 KA로 인한 뇌세포 변성 개선에 중요한 인자로 작용할 것으로 사료되나, 보다 명확한 APT의 기전을 검색하고 직접 임상에 응응하기 위하여는 보다 다양한 실험 조건이 보완되어야 찰 것으로 생각된다. 항우울약들의 항혈소판작용은 PKC-기질인 41-43 kD와 20 kD의 인산화를 억제함에 기인되는 것으로 사료된다.다. 것으로 사료된다.다.바와 같이 MCl에서 작은 Dv 값을 갖는데, 이것은 CdCl$_{4}$$^{2-}$ 착이온을 형성하거나 ZnCl$_{4}$$^{2-}$ , ZnCl$_{3}$$^{-}$같은 이온과 MgCl$^{+}$, MgCl$_{2}$같은 이온종을 형성하기 때문인것 같다. 한편 어떠한 용리액에서던지 NH$_{4}$$^{+}$의 경

  • PDF

Autofocus of Infinity-Corrected Optical Microscopes by Confocal Principle and Fiber Source Modulation Technique (공초점 원리와 광섬유 광원 변조를 이용한 무한보정 현미경 자동초점)

  • Park, Jung-Jae;Kim, Seung-Woo;Lee, Ho-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.583-590
    • /
    • 2004
  • The autofocus is one of the important processes in the automated vision inspection or measurements using optical microscopes, because it influences the measuring accuracy. In this paper, we used the confocal microscope configuration based on not a pinhole but a single-mode optical fiber. A single mode fiber has the functions of source and detector by applying the reciprocal scheme. As a result, we acquired a simple system configuration and easy alignment of the optical axis. Also, we embodied a fast autofocus system by acquiring the focus error signal through a source modulation technique. The source modulation technique can effectively reduce physical disturbances compared with objective lens modulation, and it is easily applicable to general optical microscopes. The focus error signal was measured with respect to the modulation amplitude, reflectance of the specimen and inclination angle of the measuring surface. The performance of the proposed autofocus system was verified through autofocusing flat mirror surface. In addition, we confirmed that source modulation rarely degrades the depth resolution by the comparison between the FWHMs of axial response curves.

Analysis of Laser-beam Thermal Effects In an Infrared Camera and Laser Common-path Optical System (적외선 카메라-레이저 공통광학계의 레이저빔 열 영향성 분석)

  • Kim, Sung-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.4
    • /
    • pp.153-157
    • /
    • 2017
  • An infrared camera and laser common-path optical system is applied to DIRCM (directional infrared countermeasures), to increase boresighting accuracy and decrease weight. Thermal effects of a laser beam in a common-path optical system are analyzed and evaluated, to predict any degradation in image quality. A laser beam with high energy density is absorbed by and heats the optical components, and then the surface temperature of the optical components increases. The heated optical components of the common-path optical system decrease system transmittance, which can degrade image quality. For analysis, the assumed simulation condition is that the laser is incident for 10 seconds on the mirror (aluminum, silica glass, silicon) and lens (sapphire, zinc selenide, silicon, germanium) materials, and the surface temperature distribution of each material is calculated. The wavelength of the laser beam is $4{\mu}m$ and its output power is 3 W. According to the results of the calculations, the surface temperature of silica glass for the mirror material and sapphire for the lens material is higher than for other materials; the main reason for the temperature increase is the absorption coefficient and thermal conductivity of the material. Consequently, materials for the optical components with high thermal conductivity and low absorption coefficient can reduce the image-quality degradation due to laser-beam thermal effects in an infrared camera and laser common-path optical system.