• Title/Summary/Keyword: 정밀태양센서

Search Result 39, Processing Time 0.029 seconds

Current Status of Hyperspectral Data Processing Techniques for Monitoring Coastal Waters (연안해역 모니터링을 위한 초분광영상 처리기법 현황)

  • Kim, Sun-Hwa;Yang, Chan-Su
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.1
    • /
    • pp.48-63
    • /
    • 2015
  • In this study, we introduce various hyperspectral data processing techniques for the monitoring of shallow and coastal waters to enlarge the application range and to improve the accuracy of the end results in Korea. Unlike land, more accurate atmospheric correction is needed in coastal region showing relatively low reflectance in visible wavelengths. Sun-glint which occurs due to a geometry of sun-sea surface-sensor is another issue for the data processing in the ocean application of hyperspectal imagery. After the preprocessing of the hyperspectral data, a semi-analytical algorithm based on a radiative transfer model and a spectral library can be used for bathymetry mapping in coastal area, type classification and status monitoring of benthos or substrate classification. In general, semi-analytical algorithms using spectral information obtained from hyperspectral imagey shows higher accuracy than an empirical method using multispectral data. The water depth and quality are constraint factors in the ocean application of optical data. Although a radiative transfer model suggests the theoretical limit of about 25m in depth for bathymetry and bottom classification, hyperspectral data have been used practically at depths of up to 10 m in shallow and coastal waters. It means we have to focus on the maximum depth of water and water quality conditions that affect the coastal applicability of hyperspectral data, and to define the spectral library of coastal waters to classify the types of benthos and substrates.

진공공정 실시간 측정 기술 개발 동향

  • Sin, Yong-Hyeon;Hong, Seung-Su;Im, In-Tae;Seong, Dae-Jin;Im, Jong-Yeon;Kim, Jin-Tae;Kim, Jeong-Hyeong;Gang, Sang-U;Yun, Ju-Yeong;Yu, Sin-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.28-28
    • /
    • 2011
  • 우리나라의 주력산업인 반도체 및 디스플레이의 경우 그 생산 설비의 1/3이상이 진공 장비이며 진공 공정을 통해 만들어진다. 이들 산업 분야에서는 우리나라가 세계 최고의 생산 기술을 가지고 있으므로 자체적인 기술 개발 확보가 중요하다. 최근에는 기존에 개발되어 있는 장비의 성능을 뛰어넘어야 하는 공정 기술력이 요구되면서, 진공 공정 기술 개발이 매우 중요한 이슈가 되었다. 반도체나 디스플레이 산업 등 기존 주력산업의 전후방 산업의 경쟁력 강화 측면에서뿐 아니라 태양전지, LED 등 진공기술을 이용한 신성장 동력 산업의 생산 시스템 경쟁력 확보 측면에서도 진공 공정 기술 개발 중요성은 매우 크다. 지금까지 양산에 적용되는 증착, 식각, 확산 등 진공 공정 운영은, 사전 시험을 통해 얻은 최적 공정의 입력 파라미터들을 정해 놓고 그대로 공정을 진행한 뒤, 생산되어 나오는 제품의 상태를 사후 측정하여 공정 이상 여부를 점검하고 미세 조정하는 형태로 진행되고 있다. 실질적으로 현재 진행 중인 진공 공정에 대한 직접적인 정보가 없으므로 공정 중 발생되는 문제들에 대한 대처는 그 공정이 끝난 후에 이루어지는 상황이다. 공정 미세화 및 대구경화에 따라 기존의 wafer to wafer 제어 개념 보다 발전된 개념으로 센서 기반 실시간 공정 진단 제어 기술의 필요성이 대두되었으며 이를 위한 오류 인식 및 예지기술 (Fault Detection & Classification, FDC) 그리고 이 정보를 이용한 첨단 제어 기술(Advanced Process Control, APC)을 개발하는 노력들이 시작되었다. 한국표준과학연구원에서는 수요기업인 대기업과 장비업체, 센서 개발 중소기업 및 학교 연구소와 공동으로 진공 공정 실시간 측정 진단 제어와 관련된 연구를 하고 있다. 진공 공정 환경측정 기술, 플라즈마 상태 측정 기술, 진공 공정 중 발생하는 오염입자 측정 원천 기술 개발과 이를 구현하기 위한 센서 개발, 화학 증착 소스 및 진공 공정 부품용 소재에 대한 평가 플랫폼 구축, 배기 시스템 진단기술 개발 등 현재 진행되고 있는 기술 개발 내용과 동향을 소개한다. 진공 공정 실시간 측정 기술이 확보되면 차세대 반도체 제작에 필요한 정밀 공정 제어가 가능해지고, 공정 이상에 바로 대응 혹은 예방 할 수 있으며, 여유분으로 필요 이상으로 투입되던 자원(대기시간, 투입 재료, 대체용 장비)을 절감하는 등 생산성을 향상을 기대할 수 있다. 또한 진공 환경에서 이루어지는 박막 증착, 식각 공정 과정에 대한 이해가 높아지고, 공정을 개발하고 최적화하는데 유용한 정보를 제공할 수 있으므로, 기존 장비와 차별화된 경쟁력을 가진 고품위 진공 장비 및 부품 개발에 기여할 수 있을 것으로 기대하고 있다.

  • PDF

경사코팅 기술과 이를 이용한 완전화 박막의 제조

  • Jeong, Jae-In;Yang, Ji-Hun;Jang, Seung-Hyeon;Park, Hye-Seon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.506-507
    • /
    • 2011
  • 경사코팅 기술(Oblique Angle Deposition; OAD)은 입사 증기가 기판에 수직으로 입사하지 않고 90도 보다 작은 각도로 비스듬히 입사하도록 조절하여 코팅하는 물리증착 기술의 하나로 피막의 조직을 다양하게 제어할 수 있는 방법으로 알려져 있다. 초기의 경사 코팅 기술은 경사각을 가진 정지된 기판 상에 코팅하였으나 최근에는 기판의 각도와 회전을 동시에 조절하여 이루어지는 소위 스침각 증착(Glancing Angle Deposition; GLAD) 기술이 개발되어 다양한 형태의 구조를 제어하는 연구가 활발히 진행되고 있다. 특히, 컴퓨터를 이용하여 입사각과 방위각을 정밀 제어함에 의해 나노 스케일의 Zigzag 및 나선형, 기둥형 조직 등 복잡한 형태의 박막을 제조하는 것이 가능하게 되었다. 현재, GLAD 기술과 다양한 형태의 나노 조직을 이용하여 각종 센서는 물론 태양전지와 같은 에너지 소자, 필터와 같은 광학코팅 등에 응용하기 위한 연구가 세계적으로 폭넓게 진행되고 있다. 본 연구에서는 조직의 치밀도 향상을 통한 특성 향상을 위해 Al 및 TiN 박막을 제조함에 있어서 경사코팅 기술을 응용하여 단층 및 다층 피막(각도를 반대로 하여 여러 층을 제조)을 제조하고 그 특성을 비교하였다. Al 박막은 UBM (Un-Balanced Magnetron) 스퍼터링 소스를 이용하여 타겟 표면과 기판 표면이 이루는 각도 즉, 입사빔과 기판이 이루는 각도를 각각 0, 30, 45, 60 및 90도의 각도에서 강판 및 실리콘 웨이퍼 상에 시편을 제조하되 단층 및 다층으로 시편을 제조하고 치밀도 및 내식성과 반사율 및 조도 등의 특성을 비교하였다. 그 결과 경사각으로 코팅한 시편에서 조도 및 반사율이 향상됨은 물론 치밀도 및 내식성이 향상됨을 확인하였다. 특히, 염수분무에 의한 내식성 시험에서 경사 코팅된 시편의 경우 내식성이 현저히 향상되었는데, 이는 경사 코팅 방법이 박막의 치밀도를 향상시켜 나타난 현상으로 판단된다. TiN 박막은 Cathodic Arc 방식을 이용하되 Al 박막과 동일한 방법으로 코팅을 하고 내식성 및 경도 등의 특성을 비교하였다. TiN 박막은 경사각이 커지면서 경도가 낮아지며 특히 다층막의 경우 경도 감소가 현저함을 알 수 있었다. 다만, 45도에서는 다른 경사각에 비해 약간의 경도 상승이 측정되었다. 경사각 코팅에서의 경도 감소는 피막의 경사에 의해 탐침이 미끄러지거나 또는 우선 방위에 의한 경도 증가 효과가 나타나지 않아 생기는 현상으로 판단되었다. Ferroxyl 시험을 이용한 기공도 시험에서는 경사각 코팅의 경우가 기공이 다소 감소함을 확인하였다.

  • PDF

Epipolar Image Resampling from Kompsat-3 In-track Stereo Images (아리랑3호 스테레오 영상의 에피폴라 기하 분석 및 영상 리샘플링)

  • Oh, Jae Hong;Seo, Doo Chun;Lee, Chang No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.6_1
    • /
    • pp.455-461
    • /
    • 2013
  • Kompsat-3 is an optical high-resolution earth observation satellite launched in May 2012. The AEISS sensor of the Korean satellite provides 0.7m panchromatic and 2.8m multi-spectral images with 16.8km swath width from the sun-synchronous near-circular orbit of 685km altitude. Kompsat-3 is more advanced than Kompsat-2 and the improvements include better agility such as in-track stereo acquisition capability. This study investigated the characteristic of the epipolar curves of in-track Kompsat-3 stereo images. To this end we used the RPCs(Rational Polynomial Coefficients) to derive the epipolar curves over the entire image area and found out that the third order polynomial equation is required to model the curves. In addition, we could observe two different groups of curve patterns due to the dual CCDs of AEISS sensor. From the experiment we concluded that the third order polynomial-based RPCs update is required to minimize the sample direction image distortion. Finally we carried out the experiment on the epipolar resampling and the result showed the third order polynomial image transformation produced less than 0.7 pixels level of y-parallax.

Airborne Hyperspectral Imagery availability to estimate inland water quality parameter (수질 매개변수 추정에 있어서 항공 초분광영상의 가용성 고찰)

  • Kim, Tae-Woo;Shin, Han-Sup;Suh, Yong-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.61-73
    • /
    • 2014
  • This study reviewed an application of water quality estimation using an Airborne Hyperspectral Imagery (A-HSI) and tested a part of Han River water quality (especially suspended solid) estimation with available in-situ data. The estimation of water quality was processed two methods. One is using observation data as downwelling radiance to water surface and as scattering and reflectance into water body. Other is linear regression analysis with water quality in-situ measurement and upwelling data as at-sensor radiance (or reflectance). Both methods drive meaningful results of RS estimation. However it has more effects on the auxiliary dataset as water quality in-situ measurement and water body scattering measurement. The test processed a part of Han River located Paldang-dam downstream. We applied linear regression analysis with AISA eagle hyperspectral sensor data and water quality measurement in-situ data. The result of linear regression for a meaningful band combination shows $-24.847+0.013L_{560}$ as 560 nm in radiance (L) with 0.985 R-square. To comparison with Multispectral Imagery (MSI) case, we make simulated Landsat TM by spectral resampling. The regression using MSI shows -55.932 + 33.881 (TM1/TM3) as radiance with 0.968 R-square. Suspended Solid (SS) concentration was about 3.75 mg/l at in-situ data and estimated SS concentration by A-HIS was about 3.65 mg/l, and about 5.85mg/l with MSI with same location. It shows overestimation trends case of estimating using MSI. In order to upgrade value for practical use and to estimate more precisely, it needs that minimizing sun glint effect into whole image, constructing elaborate flight plan considering solar altitude angle, and making good pre-processing and calibration system. We found some limitations and restrictions such as precise atmospheric correction, sample count of water quality measurement, retrieve spectral bands into A-HSI, adequate linear regression model selection, and quantitative calibration/validation method through the literature review and test adopted general methods.

Retrieval of Atmospheric Optical Thickness from Digital Images of the Moon (월면 디지털 영상 분석을 이용한 대기 광학두께 산출)

  • Jeong, Myeong-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.5
    • /
    • pp.555-568
    • /
    • 2013
  • Atmospheric optical thickness during nighttime was estimated in this study using analysis on the images of the moon taken from commercial digital camera. Basically the Langely Regression method was applied to the observations of the moon for the cloudless and optically stable sky conditions. The spectral response functions for the red(R), green(G), and blue(B) channels were employed to derive effective wavelength centers of each channel for the observations of the moon, and the correspondent Rayleigh optical thickness were also calculated. Aerosol optical thickness (AOT) was calculated by subtracting Rayleigh optical thickness from the atmospheric optical thickness derived from the Langley regression method. As there are only handful of nighttime AOT observations, the AOT from the moon observations was compared with the AOT from sun-photometers and the MODIS satellite sensor, which was taken several hours before the moon observations of this study. As a result, the values of AOT from moon observations agree with those from sun-photometers and MODIS within 0.1 for the R, G, B channels of the digital camera. On the other hand, ${\AA}$ngstr$\ddot{o}$m Exponent seems to be subject to larger errors due to its sensitiveness to the spectral errors of AOT. Nevertheless, the results of this study indicate that the method reported in this study is promising as it can provide nighttime AOT relatively easily with a low cost instrument like digital camera. More observations and analyses are warranted to attain improved nighttime AOT observations in the future.

The Effect of Equatorial Spread F on Relative Orbit Determination of GRACE Using Differenced GPS Observations (DGPS기반 GRACE의 상대궤도결정과 Equatorial Spread F의 영향)

  • Roh, Kyoung-Min;Luehr, Hermann;Park, Sang-Young;Cho, Jung-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.499-510
    • /
    • 2009
  • In this paper, relative orbit of Low Earth Orbit satellites is determined using only GPS measurements and the effects of Equatorial Spread-F (ESF), that is one of biggest ionospheric irregularities, are investigated. First, relative orbit determiation process is constructed based on doubly differenced GPS observations. In order to see orbit determination performance, relative orbit of two GRACE satellites is estimated for one month in 2004 when no ESF is observed. The root mean square of the achieved baselines compared with that from K-Band Ranger sensor is about 2~3 mm and average of 95% of ambiguities are resolved. Based on this performance, the relative orbit is estimated for two weeks of two difference years, 2003 when there are lots of ESF occurred, and 2004 when only few ESF occurred. For 2003, the averaged baseline error over two weeks is about 15 mm. That is about 4 times larger than the case of 2004 (3.6 mm). Ionospheric status achieved from K-Band Ranging sensor also shows that more Equatorial Spread-F occurred at 2003 than 2004. Investigation on raw observations and screening process revealed that the ionospheric irregualarities caused by Equatorial Spread-F gave significant effects on GPS signal like signal loss or enhancement ionospheric error, From this study, relative orbit determination using GPS observations should consider the effect of Equatorial Spread-F and adjust orbit determination strategy, especially at the time of solar maximum.

Improvement of PWM Driving Control Characteristics for Low Power LED Security Light (저전력형 LED 보안등의 PWM형 구동제어 특성 개선)

  • Park, Hyung-Jun;Kim, Nag-Cheol;Kim, In-Su
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.368-374
    • /
    • 2017
  • In this Paper, we developed a low power type LED security light using LED lighting that substitutes a 220[V] commercial power source for a solar cell module instead of a halogen or a sodium lamp. in addition, a PWM type drive control circuit is designed to minimize the heat generation problem and the drive current of the LED drive controller. in developed system, The light efficiency measurement value is 93.6[lm/W], and a high precision temperature sensor is used inside the controller to control the heat generation of the LED lamp. In order to eliminate the high heat generated from the LED lamp, it is designed to disperse quickly into the atmosphere through the metal insertion type heat sink. The heat control range of LED lighting was $50-55[^{\circ}C]$. The luminous flux and the lighting speed of the LED security lamp were 0.5[s], and the beam diffusion angle of the LED lamp was about $110[^{\circ}C]$ by the light distribution curve based on the height of 6[m].

Development of New Ocean Radiation Automatic Monitoring System (새로운 해양 방사선 자동 감시 시스템의 개발)

  • Kim, Jae-Heong;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.743-746
    • /
    • 2019
  • In this paper we proposed a new ocean radiation automatic monitoring system. The proposed system has the following characteristics: First, using NaI + PVT mixed detectors, the response speed is fast and precision analysis is possible. Second, the application of temperature compensation algorithm to scintillator-type sensors does not require additional cooling devices and enables stable operation in the changing ocean environment. Third, since cooling system is not needed, electricity consumption is low, and electricity can be supplied reliably by utilizing solar energy, which can be installed at the observation deck of ocean environment. Fourth, using GPS and wireless communications, accurate location information and real-time data transmission function for measurement areas enables immediate warning response in the event of nuclear accidents such as those involving neighboring countries. The results tested by the authorized testing agency to assess the performance of the proposed system were measured in the range of $5{\mu}Sv/h$ to 15mSv/h, which is the highest level in the world, and the accuracy was determined to be ${\pm}8.1%$, making normal operation below the international standard ${\pm}15%$. The internal environmental grade (waterproof) was achieved, and the rate of variation was measured within 5% at operating temperature of $-20^{\circ}C$ to $50^{\circ}C$ and stability was verified. Since the measured value change rate was measured within 10% after the vibration test, it was confirmed that there will be no change in the measured value due to vibration in the ocean environment caused by waves.