• Title/Summary/Keyword: 정량한계

Search Result 1,449, Processing Time 0.034 seconds

Multiresidue Analysis Method for Determination of Unregistered Organophosphorus Pesticides in Korea for Imported Agri-Food (국내 미등록 유기인계 농약의 수입 농식품에 대한 다성분 잔류분석법)

  • Jeon, Young-Hwan;Hwang, Jeong-In;Ahn, Ji-Woon;Kim, Hyo-Young;Do, Jung-Ah;Oh, Jae-Ho;Hwang, In-Gyun;Im, Moo-Hyeog;Lee, Joong-Keun;Lee, Young-Deuk;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.3
    • /
    • pp.277-285
    • /
    • 2012
  • BACKGROUND: For safety evaluation of imported agri-food in Korea, the multiresidue analysis method was establised for unregistered organophosphorus pesticides, aspon, chlorthion, chlorthiophos, crotoxyphos, demeton-O, demeton-S, demeton-S-methyl, dioxathion, heptenophos, iodofenphos, leptophos, methyl-trithion, propetamphos and sulfotep. METHODS AND RESULTS: The used method for multiresidue analysis in brown rice and orange used as representative samples of imported agri-food was the official method of Korean Food and Drug Administration. The results of validation test of 13 organophosphorus pesticides except crotoxyphos for multiresidue analysis method are compared to the criteria such as specificity, linearity, accuracy, precision and limit of quantification. CONCLUSION: The used method for multiresidue analysis of unregistered 13 organophosphorus pesticides except crotoxyphos in Korea can surely be used as an official method for routine analysis of imported agri-food.

Preconcentration and Extraction of Copper on Activated Carbon Using 4-Amino-2, 3-dimethyl-1-phenyl-3-pyrazoline or 4-(4-methoxybenzylidenimin) thiophenole (4-Amino-2,3-dimethyl-1-phenyl-3-pyrazoline 또는 4-(4-Methoxybenzylidenimin)thiophenole을 이용한 활성탄에서의 구리의 예비 농축 및 추출)

  • Ghaedi, Mehrorang;Ahmadi, Farshid;Karimi, Hajir;Gharaghani, Shiva
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.1
    • /
    • pp.23-31
    • /
    • 2006
  • carbon modified methods were used for the preconcentration and determination of copper in some real samples using the flame atomic absorption spectrometry. The copper ions was adsorbed quantitatively on the activated carbon due to their complexation with 4- amino-2, 3-dimethyl-1-phenyl-3-pyrazoline (ADMPP) or 4-(4- methoxybenzylidenimin) thiophenole (MBITP). The adsorbed copper on solid phase was eluted quantitatively using small amount of nitric acid. The influence of important parameters including pH, amount of carrier, flow rate, amount of activated carbon and type and concentration of eluting agent for obtaining maximum recovery were investigated. The methods based on ADMPP and MBITP at optimum conditions is linear over concentration range of 0.05-1.5 g mL-1 and 0.05-1.2 g mL-1 of copper with correlation coefficient of 0.9997 and 0.9994 and both detection limit of 1.4 ng mL-1, respectively. The preconcentration leads to enrichment factor of 310 and break through volume of 1550 mL for both ligands. The method has a good tolerance limit of interfering ion and a selectivity that has been successfully applied for the determination of copper content in real sample such as tap, spring, river and waste water.

Application of Multiresidue Analysis Method of Unregistered Pesticides in Korea for Imported Food (수입식품 중 국내 미등록 농약의 다성분 잔류분석법 적용)

  • Jeon, Young-Hwan;Kim, Hyo-Young;Hwang, Jeong-In;Kim, Ji-Hwan;Do, Jung-Ah;Im, Moo-Hyeog;Oh, Jae-Ho;Kwon, Ki-Sung;Lee, Joong-Keun;Lee, Young-Deuk;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.339-345
    • /
    • 2011
  • BACKGROUND: Recently in Korea, the import of agricultural products is rising due to the increasing amount of trade. Unregistered pesticides, allidochlor, propachlor, propham, cycloate, diallate and pebulate are widely used as pesticides for rice cultivation in foreign countries, while they are not registered in Korea. Therefore, the residue amount of imported agri-foods should be verified using the proper official analytical method for each of them that has not registered in Korea. METHODS AND RESULTS: This work was conducted to apply the official method of Korea Food & Drug Administration (KFDA) for determining multi class pesticide multiresidues in agricultural commodities. Brown rice and orange which have different characteristics as a matrix were selected as representative samples for residue analysis. The recoveries of cycloate, diallate and pebulate by GC/MS in fortified brown rice and orange with levels of 0.04~0.4 mg/kg were ranged from 82.8% to 110.3%. The quantification limits of three pesticides in brown rice and orange were 0.04 mg/kg. CONCLUSION: As a result, this method can surely be used as an official method for routine analysis of unregistered pesticides in Korea for imported agri-food.

Determination of Sildenafil and Its Related Substances Using High Performance Thin Layer Chromatography (고성능 박층 크로마토그래프를 이용한 실데나필과 그 유사 물질의 정량에 관한 연구)

  • Choi, Hyun-Cheol;Kang, Sin-Jung;Yun, Mi-Ok;Park, Sang-Aeh;Kim, Ho-Jeong;We, Sae-Seung;Kim, Ja-Yeon;Cha, Ki-Won
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.32-38
    • /
    • 2003
  • The rapid and sensitive determination method of sildenafil and its related compounds (Vardenafil, Homosildenafil, Tadanafil.) has been investigated using high performance thin layer choromatography (HPTLC). Optimizing separation conditions and simultaneous determination method of these compounds were studied. The calibration curves of those compounds at 254 nm was found to be linear in the range of $1.0{\sim}56.5{\mu}g/mL$, respectively. The detection limts (LOD) and quantification limits (LOQ) of these were found to be $0.8{\sim}1.8{\mu}g/mL$ and $1.0{\sim}2.3{\mu}g/mL$. The coefficient of variation (C.V.) were less than 2.5%. Finally, the present method was applied to determine sildenafil and its related substances in dietary supplement.

Determination of Sodium Alginate in Processed Food Products Distributed in Korea

  • Yang, Hyo-Jin;Seo, Eunbin;Yun, Choong-In;Kim, Young-Jun
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.6
    • /
    • pp.474-480
    • /
    • 2021
  • Sodium alginate is the sodium salt of alginic acid, commonly used as a food additive for stabilizing, thickening, and emulsifying properties. A relatively simple and universal analysis method is used to study sodium alginate due to the complex pretreatment process and extended analysis time required during the quantitative method. As for the equipment, HPLC-UVD and Unison US-Phenyl column were used for analysis. For the pretreatment condition, a shaking apparatus was used for extraction at 150 rpm for 180 minutes at room temperature. The calibration curve made from the standard sodium alginate solution in 5 concentration ranges showed that the linearity (R2) is 0.9999 on average. LOD and LOQ showed 3.96 mg/kg and 12.0 mg/kg, respectively. Furthermore, the average intraday and inter-day accuracy (%) and precision (RSD%) were 98.47-103.74% and 1.69-3.08% for seaweed jelly noodle samples and 99.95-105.76% and 0.59-3.63% for sherbet samples, respectively. The relative uncertainty value was appropriate for the CODEX standard with 1.5-7.9%. To evaluate the applicability of the method developed in this study, the sodium alginate concentrations of 103 products were quantified. The result showed that the detection rate is highest from starch vermicelli and instant fried noodles to sugar processed products.

Trace level analysis of Pb in plasma by inductively coupled plasma/mass spectrometry (유도결합플라즈마 질량분석법을 이용한 혈장 중 극미량 납 분석)

  • Lee, Sung-Bae;Yang, Jeong-Sun;Choi, Sung-Bong;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.190-196
    • /
    • 2012
  • The human exposure of lead has usually detected the amount of lead in the whole blood, however, this method has a shortcoming to give the information on the short-term exposure to lead. In that sense, it is desirable to estimates the level of lead in plasma to draw the chronic bio-marker of lead exposure even though it is difficult to measure lead of several ng/L. An inductively coupled plasma-mass spectrometry (ICP-MS) method was developed for determining lead in plasma as the chronic bio-marker of lead of workers. To minimize the contamination of lead from the environment, we constructed class 1,000 clean room and compared the amount of floating dust before and after the operation of the clean room. The limit of detection (LOD) and the limit of quantification (LOQ) of lead in fetal bovine serum were 4.3 ng/L and 12.2 ng/L by NIOSH method (statistical calculation method) and 7.0 ng/L and 22.1 ng/L by signal/noise ratio, respectively. The accuracy was in a range of 92.3-101.3%, and the precision of the assay was less than 4% in the samples spiked in the concentration of 20 ng/L and 2,000 ng/L. The method was simple, reproducible and sensitive enough to permit reliable analysis of lead to the ng/L level in plasma and/or serum. The method was also useful for the biological monitoring of chronic exposure to lead.

Simultaneous determination of aromatic material causing allergic in children's products by Gas Chromatography (어린이 제품 중 가스 크로마토그래피를 이용한 알러지 유발 방향성 물질의 동시분석법)

  • Ko, Kyeong Mok;Rhu, Chan Joo;Kim, Jong Won;Lee, Seok Ki
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.23-30
    • /
    • 2018
  • Twenty-two allergy-induced aromatics in children were analyzed using a gas chromatography flame ionization detector (GC-FID) and gas chromatography mass spectrometer (GC-MSD). Analytes were extracted using an automatic Soxhlet extractor and centrifuged for 10 min in a fast freezing centrifuge, and the supernatant was transferred into a 2 mL vial and injected in split mode. Under the established conditions, the calibration curve showed linearity with a correlation coefficient of 0.996 or more. A wide range of sensitivity of 6.7 to 1,859,839 depending on the device characteristics and detector used was shown. The detection limit of the device was 0.0032 to $0.0335{\mu}g/mL$, and the maximum detection limit was less than $0.1{\mu}g/mL$. The detection limit of the method ranged from 0.0033 to $0.1161{\mu}g/mL$. In addition, the limit of quantification ranged from 0.0100 to $0.5422{\mu}g/mL$, with a level of precision ranging from 0.21 % to 4.89 % and a degree of accuracy ranging from 89 % to 111 %. The analytical method developed in this study was applied to commercial products.

Bioanalytical method validation for determination of arsenic speciation in dog plasma using HPLC-ICP/MS (Dog 혈장 중 HPLC-ICP/MS를 이용한 비소 화학종 분석법 검증)

  • Kim, Jong-Hwan;Kwon, Young Sang;Shin, Min-Chul;Kim, Su Jong;Seo, Jong-Su
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.234-241
    • /
    • 2016
  • The approach presented in this article refers to the bioanalytical method validation for the detection and quantitative determination of arsenic species including arsenite (As(III)), arsenate (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) in dog plasma by high-performance liquid chromatography inductively coupled plasma mass spectrometry (HPLC-ICP/MS). The arsenic species were separated using an agilent As speciation column by a mobile phase of 2 mM sodium phosphate monobasic, 0.2 mM ethylenediaminetetraacetic acid disodium salt dehydrate, 10 mM sodium acetate, 3 mM sodium nitrate and 1 % ethyl alcohol at pH 11 (adjusted with 1M NaOH). The method validation experiment was obtained selectivity, linearity, accuracy, precision, matrix effect, recovery, system suitability, dilution integrity and various stabilities. All calibration curves showed good linearity (R2>0.999) within test ranges. The lower limit of quantitation (LLOQ) was 5 ng/mL for As(III), As(V) and DMA, and 20 ng/mL for MMA. The system suitability and dilution values were within 6.5 % and 7.7 %. Subsequently, the developed and validated HPLC-ICP/MS method was also successfully applied to determine the arsenic speciation in dog plasma samples, and the recoveries for the spiked samples were in the range of 91.5–102.2 %. Therefore, this method could be applied to the evaluation of arsenic exposure, health effect assessment and other bio-monitoring studies in biological samples.

Plastic Limit Loads for Slanted Circumferential Through-Wall Cracked Pipes Using 3D Finite-Element Limit Analyses (3차원 유한요소 한계해석을 이용한 원주방향 경사관통균열 배관의 소성한계하중)

  • Jang, Hyun-Min;Cho, Doo-Ho;Kim, Young-Jin;Huh, Nam-Su;Shim, Do-Jun;Choi, Young-Hwan;Park, Jung-Soon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1329-1335
    • /
    • 2011
  • On the basis of detailed 3D finite-element (FE) limit analyses, the plastic limit load solutions for pipes with slanted circumferential through-wall cracks (TWCs) subjected to axial tension, global bending, and internal pressure are reported. The FE model and analysis procedure employed in the present numerical study were validated by comparing the present FE results with existing solutions for plastic limit loads of pipes with idealized TWCs. For the quantification of the effect of slanted crack on plastic limit load, slant correction factors for calculating the plastic limit loads of pipes with slanted TWCs from pipes with idealized TWCs are newly proposed from extensive 3D FE calculations. These slant-correction factors are presented in tabulated form for practical ranges of geometry and for each set of loading conditions.

Improvement of the detection limit of rapid detection kit for Salmonella Typhimurium using image analysis system (이미지 분석을 이용한 살모넬라 신속 진단키트의 측정감도 향상)

  • Lee, Sangdae;Kim, Giyoung;Park, Saet-Byeol;Moon, Ji-Hea
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.3
    • /
    • pp.421-425
    • /
    • 2012
  • The objective of this study was to improve the detection limit of rapid detection kit for Salmonella Typhimurium by image analysis system. The rapid detection kit was comprised of four elements: sample pad, conjugate pad, nitrocellulose pad and absorbent pad. Gold nanoparticle and Salmonella antibody were used as a tag and a receptor. Salmonella antibody and goat rabbit IgG antibody were used as test and control lines on nitrocellulose membrane. The color intensity of test line began to increase from $10^5CFU/mL$ of Salmonella sample. A multiple linear regression analysis was employed to explain the relationship between predicted and measured number of Salmonella cells. The developed model could successfully predict the cell number of Salmonella with validation against extra-experimental result.