• Title/Summary/Keyword: 정량적 초음파

Search Result 230, Processing Time 0.024 seconds

A High efficient realization for quantity of ultrasonic motor (초음파 모터의 정량적 최대효율 구현)

  • Lee, Young-Dae;Lee, Eul-Jae;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2151-2155
    • /
    • 1998
  • The traveling wave type ultrasonic motor(USM) has no electro-magnetic circuits( coil or core). The driving principle of the USM is based on high-frequency mechanical vibrations and frictional force. The USM, thus, is fed by two-phase high - frequency sinusoidal inverter using its series resonant parasitic components. For the using of series resonant type inverter, it should be needed to a USM parasitic capacitance and a proper inductor chosen. In this paper, the values of optimal inductance are designed and the efficiency of USM drives is achieved. The effectiveness of the proposed design is demonstrated by experiments.

  • PDF

A Study on a Quantitative Measurement of Contact Pressure Between two Rough Flat SurFaces by Means of Ultrasonic Waves. (초음파를 이용한 이체 평면접촉부의 정량적인 접촉압력 측정에 관한 연구)

  • 김경모;정인성
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.8-26
    • /
    • 1990
  • It is important to have exact information about the contact pressure distribution in the design of connected parts of machines and structures. In previous works, stress analyses on a two body contact problem have been carried out in large numbers. Besides, the measurement of contact stress is important to confirm the adequateness of the theoretical analysis, to verify appropriateness of Hertzian contact theory and to know the practical pressure distribution, but an excellent measuring method con't be found at present. Therefore, a quantitative measurement of contact pressure by means of ultrasonic waves using a normal probe and an angle has been proposed to measure the contact pressure distribution between two rough flat surfaces. At first, in a new proposed calibration method, the relation between mean contact pressure and sound pressure of reflected waves is obtained by using calibration blocks with various surface roughnesses made of the same material as the rectangular section beams And then, this experimental results are compared with the analytical ones, and the utility of this method is discussed.

  • PDF

New Approaches to Flaw Classification and Sizing for Quantitative Ultrasonic Testing (정량적 초음파 시험을 위한 결함분류와 크기산정의 새로운 기법)

  • 송성진
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.3-16
    • /
    • 1997
  • In modern high performance engineering applications, the structural integrity of materials and structures are quite often evaluated using fracture mechanics. This evaluation in turn requires information on the flaw geometry (location, type, shape, size, and orientation). The ultrasonic nondestructive evaluation (NDE) method is one technique that is commonly used to provide such information. Flaw classification (determination of the flaw type ) and flaw sizing (prediction of the flaw shape, orientation and sizing parameters) are very important issues for quantitative ultrasonic NDE. In this paper new approaches to both classification and sizing of flaws are described together with extensive review of previous works on both topics. In the area of flaw classification, a methodology is developed which can solve classification problems using probabilistic neural networks, and in the area of flaw sizing, a time-of-flight equivalent (TOFE) sizing method is presented. The techniques proposed here are in a form that can be used directly in many practical applications to quantitative estimates of the flaw's significance.

  • PDF

Quantitative Nondestructive Evaluation of Bonded Joints utilizing Pulse-Echo Ultrasonic Test (펄스-에코법을 이용한 접착접합 시험편의 정량적 비파괴 평가)

  • Oh, Seung-Kyu;Hwang, Young-Taek;Lee, Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.157-164
    • /
    • 2003
  • The pulse-echo method is one of the most widely used ultrasonic techniques for application of nondestructive evaluation. Particularly, quantitative nondestructive evaluation of defects has been considered more important to assure the reliability and the safety of structure. Frequency energy in adhesive joints is based on the ultrasonic wave analysis. The attenuation coefficient upon wave amplitude and the frequency energy that is expressed in the term of wave pressure amplitude were utilized for the primary wave experiment. By means of a control experiment, it was confirmed that the variation of the frequency energy in adhesive joints depends on transition by stress variation. In this paper, the ultrasonic characteristics were measured for single lap joint and Double Cantilever Beam specimen with different fracture modes that was subjected to stress. Consequently, the data that was obtained from the adhesive specimen was analytically compared to the fracture mechanics parameter

Precise Estimation of Nonlinear Parameter in Pulse-Like Ultrasonic Signal (펄스형 초음파 신호에서 비선형 파라미터의 정밀 추정)

  • Ha, Job;Jhang, Kyung-Young;Sasaki, Kimio;Tanaka, Hiroaki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.77-83
    • /
    • 2006
  • Ultrasonic nonlinearity has been considered as a solution for the detection of microcracks or interfacial delamination in a layered structure. The distinguished phenomenon in nonlinear ultrasonics is the generation of higher-order harmonic waves during the propagation. Therefore, in order to quantify the nonlinearity, the conventional method measures a parameter defined as the amplitude ratio of a second-order harmonic component and a fundamental frequency component included in the propagated ultrasonic wave signal. However, its application In field inspection is not easy at the present stage because no standard methodology has yet been made to accurately estimate this parameter. Thus, the aim of this paper is to propose an advanced signal processing technique for the precise estimation of a nonlinear ultrasonic parameter, which is based on power spectral and bispectral analysis. The method of estimating power spectrum and bispectrum of the pulse-like ultrasonic wave signal used in the commercial SAM (scanning acoustic microscopy) equipment is especially considered in this study The usefulness of the proposed method Is confirmed by experiments for a Newton ring with a continuous air gap between two glasses and a real semiconductor sample with local delaminations. The results show that the nonlinear parameter obtained tv the proposed method had a good correlation with the delamination.

Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images (초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과)

  • Yang, Jeong-Hwa;Kang, Gwan-Suk;Lee, Kyung-Sung;Paeng, Dong-Guk;Choi, Min-Joo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.277-283
    • /
    • 2009
  • It is important to get clinical ultrasonic images of good quality for accurate diagnosis. In this study, it observed the change of ultrasonic images against setting frequency, dynamic range(DR) and type of probes on ultrasonic scanner. In the experiment it evaluated image of LCS (Low Contrast Sensitivity) targets(-15, -6, -3, +3, +6, +15 dB) of a standard ultrasonic test phantoms(539,551, ATS, USA) similar to solid and cystic lesions. Its imaged from convex (C3-7IM) and linear probe (L5-12IM) on SA-9900 (Medison Ltd, Korea) scanner. The images obtained altering the setting parameters which are frequency(gen, pen, res, harmonic) mode and DR($40{\sim}100\;dB$). The quality of images evaluated compare with the nominal LCS value of target and measured LCS value. The results show that there was no significant changing of quality images altering DR 40, 60, 80, 100 dB against frequency in Convex probe but the image being the highest in LCS target at DR 60 dB, harmonic of frequency mode in the -15 dB target close to cystic lesion. In Linear probe, DR 40 dB, harmonic mode at -15 dB LCS target close to nominal value. It discussed necessity of evaluation about ROC(Receiver Operating Characteristic) from the psychological viewpoint and limit of evaluation from quantified images.

  • PDF

Material Characteristics, Deterioration Evaluation and Crack Depth Estimation for Mulgyeseowon Stele in Changnyeong, Korea (창녕 물계서원 원정비의 재질특성 및 손상도 평가와 균열심도 측정)

  • Yoo, Ji Hyun;Lee, Chan Hee;Chun, Yu Gun
    • Journal of Conservation Science
    • /
    • v.30 no.4
    • /
    • pp.427-438
    • /
    • 2014
  • To measure the depth and extension on the surface cracks of the stone monument, ultrasonic pulse velocity targeted at the Mulgyeseowon Stele in Changnyeong was used in this research. Additionally, to establish a long-term countermeasure of management and conservation for this stele, we have investigated the material properties and damage on it and have conducted a precise diagnosis by a variety of non-destructive techniques. Our research has revealed that stones of the stele are composed mainly of three rock types according to the parts of it, alkali-feldspar granite, gabbro and diorite. The result of the deterioration evaluation has occurred that cracks, which are observed from every direction in the body of the stele, are the significant factors to reduce structural stability. The ultrasonic velocity for an evaluation on the properties of the stele has revealed that the speed was high in the order of body, pedestal and crown. Furthermore, to understand the present condition and occurrences of the cracks which have measured in many different forms on the stele quantitatively, we have estimated from 0.6 to 24.1cm deep of the cracks by To-Tc method using ultrasonic velocity.

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

Quantitative Defects Detection in Wind Turbine Blade Using Optical Infrared Thermography (광 적외선열화상을 이용한 풍력 블레이드의 결함 크기 정량화 연구)

  • Kwon, Koo-Ahn;Choi, Man-Yong;Park, Hee-Sang;Park, Jeong-Hak;Huh, Yong-Hak;Choi, Won Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.25-30
    • /
    • 2015
  • A wind turbine blade is an important component in wind-power generation, and is generally exposed to harsh environmental conditions. Ultrasonic inspection is mainly used to inspect such blades, but it has been difficult to quantify defect sizes in complicated composite structures. Recently, active infrared thermography has been widely studied for inspecting composite structures, in which thermal energy is applied to an object, and an infrared camera detects the energy emitted from it. In this paper, a calibration method for active optical lock-in thermography is proposed to quantify the size. Inclusion, debonding and wrinkle defects, created in a wind blade for 100 kW wind power generation, were all successfully detected using this method. In particular, a ${\phi}50.0mm$ debonding defect was sized with 98.0% accuracy.

Measurement on the Natural Frequency of a Laminated Cantilever Microbeam using a Laser Interferometer (레이저 간섭계를 이용한 적층 마이크로 외팔보의 고유진동수 측정)

  • Kim, Yun-Young;Han, Bong-Koo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.1
    • /
    • pp.17-21
    • /
    • 2018
  • The natural frequency of a laminated cantilever microbeam was studied in the present investigation. The microbeam was made of quartz on a silicon chip, and its top and bottom surfaces were coated with thin(~30nm) gold films. An ultrasonic testing platform was employed to resonate the microbeam, and its time domain signal was optically measured. The natural frequency was quantified through the fast Fourier transform of the waveform, and the result showed good agreement with a theoretical estimation from the classical beam theory. This study is expected to provide a dynamic evaluation technique for micro/nanoscale materials and micromechanical structures.